HomeMy WebLinkAboutStaff Report(*t1""
CITY Or COLLEGE STATION
Horne of TexasAP�M University®
REZONING REQUEST
FOR
THE PLAZA AT COLLEGE STATION
12-00500010
REQUEST: R-2 Duplex Residential, R-4 Multi -Family, C-1 General
Commercial and C-2 Commercial -Industrial to PDD Planned
Development District
SCALE: Approximately 11 acres
LOCATION: 410 Texas Ave, generally located at the northwest corner
APPLICANT: Mitchell & Morgan, LLP, agent for owner
PROJECT MANAGER: Jason Schubert, AICP, Principal Planner
jchubert@cstx.gov
RECOMMENDATION: Staff recommends approval of the request with the following
conditions:
1) Remove the modification for a block length waiver and provide
two public way projections along Public Way Section C-C to
the Texas A&M System property to the southwest;
2) Remove the modification to Public Ways allowing head -in
parking around the traffic circle (parallel parking is permitted);
3) Remove the modification to reduce the minimum utility line
separation distance from structures to 10 feet. Appropriate
design considerations can be made as the site infrastructure is
designed and reviewed;
a) Require the back of curb sidewalks along Public Way Section
C-C be expanded to a minimum of eight feet;
5) Provide the dual right turn lanes on southbound Texas Avenue
to westbound University Drive as a mitigation measure for the
intersection; and
6) Provide a bus stop with shelter, as approved by the City, in a
location approved by TAMU Transit Services for A&M bus
service.
Planning & Zoning Commission Page 1 of 12
March 1, 2012
Planning & Zoning Commission Page 2 of 12
March 1,2012
S
�.
/ i sy $
o
Z O O
p p m
N
m��° z z° OLLI
�NCt
�,
zzZ 0 pt9Ow
%M1'Y
.�� Q- %
♦ t 5� / -%d.A d / A A
N
l
'
i
O
u ? 7
��2U �Sa
i
\W
O
Ea m
m"o=
sWioolN
\\ yp E
i
�� v AvwOiivNs3iavHO w i 7 w
¢¢rc¢a u
e
Q
of
Q
Z
i
Ab 38p0W
W
W
NIAlbp
O
m
D
Q
_
v-
75
v
W
U o°'
-
b
� 12
�rcmv�o
L7�-
op
4
0Py
_H
�
m
x�
-
N
QQdK¢
Planning & Zoning Commission Page 3 of 12
March 1, 2012
NOTIFICATIONS
Advertised Commission Hearing Date: March 1, 2012
Advertised Council Hearing Dates: March 8, 2012
The following neighborhood organizations that are registered with the City of College Station's
Neighborhood Services have received a courtesy letter of notification of this public hearing:
None
Property owner notices mailed: 16
Contacts in support: None
Contacts in opposition: One
Inquiry contacts: One
ADJACENT LAND USES
Direction
Comprehensive Plan
Zoning
Land Use
Urban &
C-1 General
Hotel
Northwest
Redevelopment
Commercial
Texas A&M University
C-U College and
Universit
Vacant, wooded
Urban &
Redevelopment
C-1 General
Hotels, Restaurant,
Northeast
(across Texas
Commercial
Gas Station, Office
Avenue, major
arterial
Texas A&M University
C-U College and
Southeast
(across University
University
Texas A&M polo field
Drive, ma or arterial
Southwest
Texas A&M University
C-U College and
Texas A&M Student
University
housing
DEVELOPMENT HISTORY
Annexation:
1939
Zoning:
C-1 General Commercial, C-2 Commercial -Industrial, R-4 Multi -
Family, and R-2 Duplex
Final Plat:
Gorzycki Meadowlands (1936), North Park 1 (1980), remaining
portions have not been final platted.
Site development:
Multiple abandoned developments are located in this area
including the former Plaza Hotel, Kettle restaurant, Daylight
Donuts, and gas station as well as several abandoned residential
structures along the former Meadowland Street.
Planning & Zoning Commission Page 4 of 12
March 1. 2012
REVIEW CRITERIA
1. Consistency with the Comprehensive Plan: The subject property is designated as Urban
and part of Redevelopment Area II on the Comprehensive Plan Future Land Use and
Character Map. The intersection of Texas Avenue and University Drive has also been
identified as a Primary Arrival Gateway into the City. The Comprehensive Plan describes
Urban as:
This land use designation is generally for areas that should have a very intense
level of development activities. These areas will tend to consist of townhomes,
duplexes, and high -density apartments. General commercial and office uses,
business parks, and vertical mixed -use may also be permitted within growth and
redevelopment areas.
Redevelopment Area II: Texas Avenue, University Drive, and Harvey Road is described by
the Comprehensive Plan as:
This area includes a number of underperforming land uses that, due to their
proximity to two of the busiest corridors in the City, are poised for redevelopment.
Much of the area is currently subdivided into small lots, making it difficult to
assemble land for redevelopment .... The proximity of existing neighborhoods and
the Texas A&M University campus requires careful site planning and appropriate
building design. These efforts should be complimentary to the Area V: Hospitality
corridor plan, the neighborhood plan for the Eastgate area, and the Texas A&M
University Campus Master Plan and should focus on bringing vertical mixed use
and other aspects of urban character to this portion of the City.
The proposed PDD zoning with associated Concept Plan is consistent with the objectives of
the Comprehensive Plan to redevelop and consolidate underperforming properties in this
area of the City. The requested rezoning proposes to provide vertical mixed use, high
density multi -family, and pedestrian oriented development at the corner of Texas Avenue
and University Drive in proximity to the Texas A&M University campus.
2. Compatibility with the present zoning and conforming uses of nearby property and
with the character of the neighborhood: The existing zoning and conforming uses of
nearby property are consistent with the proposed uses. The scale of the proposed uses,
however are intended to be developed at a high density and more intensity than the nearby
existing fourplex, hotel and restaurant uses. The neighboring developments are developed
on more of a suburban scale with surface parking lots and open space while the proposed
development utilizes structured parking and has requested reduced setbacks and increased
density allowances.
One of the adjacent fourplex owners along Hensel Street to the northwest has expressed
concern regarding the building mass of proposed development (see attached email) and has
also expressed a desire to be included in the request. The concern relates to the potential of
a 50-foot tall building approximately 50 feet from the existing fourplex. While there is a large
differential in scale, the standard zoning ordinance does not impose restrictions between the
same types of use. The adjacent R-4 Multi -Family district does not have height limitations
either and could redevelop in a similar scale if it were able to meet place all site
requirements on the property.
Planning & Zoning Commission Page 5 of 12
March 1, 2012
Representatives of the Texas A&M University System to the southwest have verbally
expressed concerns regarding the nature and scale of the proposed development. It is our
understanding that the A&M System intends to develop their property with private
commercial, retail, residential, and other uses and is concerned about the compatibility
between their future development and the proposed development. Thus far, they have
expressed an unwillingness to accommodate vehicular, bicycle, or pedestrian connections
between the two properties, something that is commonly required between similar types of
developments throughout the City.
3. Suitability of the property affected by the amendment for uses permitted by the
district that would be made applicable by the proposed amendment: The proposed
PDD Planned Development District proposes a vertical mixed use development with a
mixture of commercial and multi -family uses. These uses are suitable for the property based
on its location within the core of the City and proximity to the Texas A&M University campus.
The scale and density of the development factor into the availability of transportation and
utility capacity in the area. As described later, the proposed development proposes some
transportation improvements and mitigation efforts and acknowledges that utility upgrades
will be necessary to provide adequate services to the development.
4. Suitability of the property affected by the amendment for uses permitted by the
district applicable to the property at the time of the proposed amendment: The C-1
General Commercial district at the corner of Texas Avenue and University Drive and R-4
Multi -Family district along the former Meadowland Street should be considered suitable,
separate uses for the property. The smaller areas of R-2 Duplex Residential and C-2
Commercial -Industrial; however, are not suitable for this area of the City that is designated
for redevelopment and intended for high intensity uses.
5. Marketability of the property affected by the amendment for uses permitted by the
district applicable to the property at the time of the proposed amendment: Most of the
properties should be considered marketable with their current zoning, though the presence
of four different zoning classifications on the property constrains the potential for large-scale
redevelopment opportunities.
6. Availability of water, wastewater, stormwater, and transportation facilities generally
suitable and adequate for the proposed use: The existing Plaza site is served by 12-inch
waterlines along Texas Avenue and University Drive. Per discussions with the applicant,
additional information will be needed through fire demand modeling on existing available
capacity. Once this has been analyzed by the applicant, the City can better understand the
proposed locations, potential required up -sizing, and the potential required re -alignment of
existing waterlines within/near the proposed development.
The existing Plaza site is served by an 8-inch gravity sanitary sewer collection line that
spans from University Drive to the existing Hensel Park Lift Station. This respective lift
station then pumps sanitary sewer flow to the 'Northeast Trunkline' via a 12-inch force main.
The 'Northeast Trunkline' conveys this flow to the Carters Creek Wastewater Treatment
Plant. Using the City of College Station's sanitary sewer modeling software and the
proposed build -out sanitary sewer demands submitted by the applicant, the City has
determined that there is not adequate capacity in the existing 8-inch sanitary sewer line that
spans from this respective development to the existing Hensel Park Lift Station. The City
has, however, concluded that there is existing available capacity in the Hensel Park Lift
Station/force main as well as the 'Northeast Trunkline'. Because of this, this development
Planning & Zoning Commission Page 6 of 12
March 1, 2012
would need to include off -site sanitary sewer improvements to provide additional collection
system capacity.
Drainage is generally to the south and west within the Wolf Pen Creek and Burton Creek
Drainage Basins, respectively. Stormwater and other public infrastructure improvements
required with site development shall be designed and constructed in accordance with the
BCS Unified Design Guidelines.
As part of the rezoning application, a Traffic Impact Analysis (TIA) was submitted. Because
of the expediency with the approval process and in order to accommodate the applicant's
timeline, up to date traffic counts were not conducted instead the applicant utilized a
previous analysis conducted in 2011 by HDR the applicant's traffic consultant, of the
intersection at Texas Avenue and University Drive. This analysis was presented to the
Bryan/College Station MPO. Based on that analysis, the TIA utilized the traffic counts and
the intersection operation analysis. The TIA indicated that the intersection of Texas Avenue
and University Drive is operating at a Level of Service (LOS) E. Utilizing a scale of LOS "A"
thru LOS "F" with "A" being the best LOS "free flow traffic" and LOS F being the worst LOS
"bumper to bumper traffic" and LOS "D" being the acceptable LOS the intersection is
operating at unacceptable LOS. With that in mind the goal was to provide mitigation
strategies that would not prevent the intersection of University Drive and Texas Avenue
operate at a worse LOS. The following mitigation strategies have been identified:
• An additional left turn bay will be added to University Drive eastbound to northbound
Texas Avenue, creating a dual left configuration by modifying the existing raised median.
• On University Drive, a right turn deceleration lane will be built to meet TxDOT design
criteria. The raised median will also be extended north beyond the proposed driveway
location. These mitigation items are at the request of TxDOT and concurred by City
staff.
• Both the Brazos Valley Transit District and TAMU Transit have indicated that they would
not alter their routes to provide service within the proposed site. However, both transit
providers have routes along University Drive and Texas Avenue. In order to mitigate
traffic at the intersection of University Drive and Texas Avenue, staff has recommended
the applicant work with both transit providers regarding bus stops along University Drive
and Texas Avenue in close proximity to the proposed site. Furthermore, pedestrian and
bicycle accommodations within the site be provided and directed toward the transit
areas.
• The former Meadowland Street intersection at University Drive will be closed and the
existing median break in University Drive closed as well. This is at the direction of
TxDOT and concurred by City staff.
• To meet the block length requirements for the site, two stub outs westbound to TAMU
property west of the proposed site are required. Ultimately this would also serve as an
alternative route to University Drive and Texas Avenue, somewhat relieving traffic at that
intersection. It is anticipated that TAMU property will be redeveloped to include
commercial, retail, and residential uses. These connections also provide important
bicycle and pedestrian route alternatives.
Planning & Zoning Commission Page 7 of 12
March 1, 2012
Through the TIA, the applicant has evaluated the effect of an additional right turn lane on
southbound Texas Avenue to westbound University Drive. Room for the construction of
the second right turn lane would be available with the proposed right-of-way of 7.5 feet
along Texas Avenue. Based on the analysis, the additional right turn lane does not
change the LOS from "E," it does decrease the AM Peak delay by 2.4% and the PM
Peak delay by 2.0%. Though the applicant has not proposed this improvement as a form
of mitigation, staff recommends it be included in the required mitigation measures to help
reduce the impact of this development on the intersection.
SUMMARY OF CONCEPT PLAN
The requested rezoning and associated Concept Plan propose a vertical mixed use and multi-
family redevelopment at the intersection of Texas Avenue and University Drive. The vertical
mixed use area consists of more than 60,000 gross square feet of ground floor general
commercial uses with multi -family units above. The multi -family area consists of multi -story
buildings oriented along the side and rear of the development along the former Meadowland
Street. The applicant proposes building heights ranging up to 70 to 80 feet or eight stories. The
development is proposed in two phases with the vertical mixed use and some of the multi -family
buildings developed in the first phase with the remainder of multi -family areas along the former
Meadowland Street and Hensel Street in the second phase. For the most part, parking will be
provided in three proposed parking garages located in different areas of the development. All
existing buildings, including the former Plaza Hotel tower, will be demolished before a building
permits will be issued for new construction.
The development will use the dimensional standards of the C-1 General Commercial zoning
district for the commercial uses and R-6 High Density Multi -Family zoning district for the
residential uses. Additional description, standards and improvements by the development will be
provided later.
Meritorious Modifications
This area is designated as a Redevelopment area in the Comprehensive Plan which
acknowledges some role for the City may be necessary to encourage redevelopment. Some
modifications result from the intended urban nature of the proposed development and some are
due to the suburban style of some of the applicable development regulations. The applicant is
requesting the following meritorious modifications or alternatives to standard ordinance
requirements:
1. Zoning District Standards — UDO Section 5.2 "Residential Dimensional Standards"
and Section 5.4 "Non -Residential Dimensional Standards": An increase to the maximum
residential unit density from 30 units per acre to 60 units per acre is proposed by the
applicant. While this increase in density can be supported, it is necessary to ensure that
adequate infrastructure and transportation facilities including vehicular, bicycle, and
pedestrian are provided for the development and surrounding area. As will be described,
staff is recommending against some of the proposed modifications that may be detrimental
to these facilities.
The applicant requests to reduce minimum building setbacks for the C-1 General
Commercial and R-6 High Density Multi -Family based zoning districts to 5 feet along all
property lines with the understanding that sufficient easements for utilities will be provided.
The standard building setbacks are 25-foot front setback, 7.5-foot side setback, 15-foot side
street setback, and 15-foot rear setback for the C-1 district and 20-foot rear setback for R-6.
Planning & Zoning Commission Page 8 of 12
March 1. 2012
2. Use — UDO Section 6.2.0 "Use Table": The P-MUD Planned Mixed Use District is the
base zoning district for uses for the development with Health Care, Medical Clinic being
added as a permitted use and Country Club, Duplex, Fuel Sales, Fraternal Lodge, Golf
Course/Driving Range, Parking as a Primary Use, Single -Family Detached, Sexual Oriented
Businesses, and Shooting Range (Indoor) uses removed from the permitted list.
3. Parking — UDO Section 7.2 "Off -Street Parking Standards": The applicant proposes the
standard shopping center ratio of 1 parking space per every 250 gross square feet of
commercial use (1:250), though not required to provide additional parking if more than 25%
of these areas are utilized as intense commercial uses. The applicant also proposes the
minimum residential parking requirement be reduced to one parking space per bedroom.
The current ordinance requires one space per bedroom for three and four bedroom units
though some additional parking is provided with one and two bedroom units (1.5 spaces/
bedroom). Also, up to 5% of the parking spaces in the garage may be compact parking
spaces. This parking reduction can be supported if sufficient transit, bicycle, and pedestrian
facilities are provided.
4. Transportation — UDO Section 7.3 "Access Management and Circulation", Section
8.2.G "Blocks", and Section 11.2 "Defined Terms"- Public Way: The applicant proposes
some modifications to transportation related requirements:
• Three driveways exist along Texas Avenue and six driveways along University Drive,
including the former Meadowland Street. Though the proposed Concept Plan
consolidates these to one driveway on Texas Avenue and one driveway on University
Drive, the proposed driveways do not meet minimum spacing standards. The applicant
requests the proposed spacing be acceptable and the concept has been agreed by
TxDOT.
• The maximum block length in Urban designated areas is 660 feet with a maximum block
perimeter of 2,000 feet. Based on these dimensions, two street/public way projections
are required along the Public Way Section C-C toward the Texas A&M System property
to the southwest. The applicant has requested a waiver to not require these connections.
Staff is not supportive of this modification as these alternative routes will help reduce the
concentration of traffic movements at the intersection of Texas Avenue and University
Drive. Though the Texas A&M System has not been supportive of any type of
connection between the two developments, they are in the process of developing a
master plan for a private development of commercial, retail, residential, and other uses
which will be subject to similar requirements.
• Public Ways are defined with certain dimensional and design criteria. The applicant
requests to reduce the maximum curve radius from a 200-foot radius to a 45-foot radius,
allow sidewalks to be back of curb instead of three feet off, allow road -side zone of less
than eight feet in Public Way Section C-C with minimum six-foot sidewalk back of curb
(see attached cross sections), and allow head -in parking around the traffic circle. Staff is
supportive of the radius and sidewalk location requests, though does not support the
head -in parking around the traffic circle or the six-foot sidewalk at the back of curb along
Public Way Section C-C. Based on the current layout the traffic circle will be critical for
vehicular circulation and allowing head -in parking movement in this area would not be
appropriate. As provided elsewhere on the Public Way, parallel parking spaces are
permitted. The six-foot back of curb sidewalk is narrower than any other minimum back
of curb sidewalk and does not provide adequate room for the required landscape
plantings.
Planning & Zoning Commission Page 9 of 12
March 1, 2012
5. Signs — UDO Section 7.4 "Signs": Instead of using this Section as the basis for signage,
the applicant proposes to utilize the signage permitted in Wolf Pen Creek (UDO Section
5.6.A.11 Signs) with the following modifications:
• Signs may be approved administratively by staff with appeals to staff's interpretations
being able to considered by the Design Review Board;
• Wayfinding signage (LIDO Section 7.4.AA Campus Wayfinding Signs) is permitted for
this development; and
• Projections signs may be used for identification signage for the general area and not
count against the attached signage square feet unless they contain copy of the individual
business. Projection signs may be oriented toward the public rights -of -way or public
ways and one permitted per tenant per public way frontage.
6. Landscaping — LIDO Section 7.5 "Landscaping and Tree Protection": Instead of using
this Section as the basis for landscaping, the applicant proposes to utilize the Northgate
standards contained in LIDO Section 5.6.B.9 "Landscape and Streetscape Standards" with
the following modifications:
• The street trees along Texas Avenue and University Drive may be placed outside of
TxDOT right-of-way. Street trees along Public Way Sections A -A and B-B shall be 50
feet on center with alternating planting areas spaced at 50 feet on center consisting of
non -canopy trees, hedges or seasonal plantings. The Public Way Section C-C will have
planting areas of 25 feet on center consisting of non -canopy trees, hedges, or seasonal
plantings;
® Building and Site Lighting shall still comply with LIDO Section 7.10 Outdoor Lighting
Standards; and
• The Street Lights section is not applicable as lights are owned and maintained by
property owner.
7. Architecture — UDO Section 7.9 "Non -Residential Architecture Standards": Instead of
using this Section as the basis for architecture standards, the applicant proposes to utilize
the Northgate standards contained in LIDO Section 5.6.B.4 "Building Design Standards'
except that residential dwelling units in a building with less than 12 units may have access
through a parking area or garage. All subsections (Building Orientation and Access, Building
Transparency, Architectural Relief, Roof Type, Exterior Building Material, Exterior Building
Colors, and Canopies/Awnings) shall apply to all non-residential and residential buildings.
8. Infrastructure — Section 3.3.A "Applicability," and BCS Unified Design Guidelines: The
applicant proposes some modifications to infrastructure related requirements:
• Most of the property is platted though a couple areas are still tracts of land. The
applicant has requested that building permits may be issued on these tracts prior to the
platting of these areas with the provision that a temporary blanket easement be placed
on the property and the property platted/repatted once all utilities are constructed and
relocated and before Certificates of Occupancy are issued for the buildings; and
• The applicant has requested to reduce the utility line separation distances from
structures to a minimum of 10 feet. Staff is not supportive of this modification at this point
as additional design details are necessary to make this determination. Staff could
consider this type of modification when the site infrastructure is being designed.
Planning & Zoning Commission Page 10 of 12
March 1, 2012
Community Benefits and Additional Enhancements
The applicant has identified the following community benefits, additional enhancements or
improvements:
1. Implementation of the Comprehensive Plan through redevelopment of an underperforming,
blighted area that is designated as a Primary Arrival Gateway and described by the
Comprehensive Plan as an area that should "focus on bringing vertical mixed -use and other
aspects of urban development to this portion of the City." All existing buildings will be
demolished before building permits will be issued for any new construction.
2. The Northgate Building Design Standards (UDO Section 5.6.B.4) apply to all buildings,
residential and non-residential. Currently there are no architectural requirements for
residential buildings outside of the Northgate District.
3. The Northgate Bicycle Parking Standards (UDO Section 5.6.B.7) apply to the development
except that the design of the bicycle rack design is determined by the owner and approved
by the City and bicycle parking may be located within the parking garage areas. Currently
there are no bicycle parking (bike rack) requirements for residential developments outside of
the Northgate District.
4. Installation of a bus stop shelter as approved by the City internal to the site to promote
transit usage and another along University Drive to utilize District bus service. Bus stops or
bus shelters are not required by standard ordinance.
5. The Northgate Dumpster and Mechanical Equipment Standards (UDO Section 5.6.B.10)
shall apply with the exception that vegetation may also be used as a screening tool.
6. The Northgate Outside Storage and Display Standards (UDO Section 5.6.B.13) shall apply
to the development.
7. The parking garage on Texas Avenue is wrapped with general commercial use on ground
floor and residential above and the other parking garages along the former Meadowland
Street are wrapped with multi -family uses.
8. An eight -foot bicycle and pedestrian route is proposed along the majority of the southwest
property line to connect multi -family buildings and two parking garages to University Drive to
allow easier bicycle and pedestrian movements from the development toward the Texas
A&M University campus.
9. Mitigation for the Texas Avenue and University Drive intersection is proposed through a
variety of transportation improvements including a dual left turn lane will be added University
Drive eastbound to Texas Avenue northbound, the median break for the former
Meadowland Street will be closed, multiple driveways will be consolidated into one driveway
on Texas Avenue and one driveway on University Drive, the median on Texas Avenue will
be extended north past the proposed Public Way driveway, and a deceleration lane will be
added to the proposed Public Way driveway on University Drive.
STAFF RECOMMENDATION
Staff recommends approval of the request with the following conditions:
1) Remove the modification for a block length waiver and provide two public way
projections along Public Way Section C-C to the Texas A&M System property to the
southwest;
2) Remove the modification to Public Ways allowing head -in parking around the traffic
circle (parallel parking is permitted);
Planning & Zoning Commission Page 11 of 12
March 1, 2012
3) Remove the modification to reduce the minimum utility line separation distance from
structures to 10 feet. Appropriate design considerations can be made as the site
infrastructure is designed and reviewed;
4) Require the back of curb sidewalks along Public Way Section C-C be expanded to a
minimum of eight feet;
5) Provide dual right turn lanes on southbound Texas Avenue to westbound University
Drive as a mitigation measure for the intersection; and
6) Provide a bus stop with shelter, as approved by the City, in a location approved by
TAMU Transit Services for A&M bus service.
SUPPORTING MATERIALS
1. Application
2. Rezoning Map
3. Concept Plan
4. Public Way Cross Sections
5. Email from Kevin Burgess,
6. Traffic Impact Analysis (will
adjacent land owner
be provided prior to meeting)
Planning & Zoning Commission
March 1, 2012
Page 12 of 12