Loading...
HomeMy WebLinkAboutStaff ReportCITY OF COLLEGE STATION PRELIMINARY PLAT for Castlegate II Subdivision 12-00500004 SCALE: 639 lots on 202.655 acres LOCATION: 4298 W S Phillips Pkwy ZONING: R-1 Single -Family Residential R-11B Single -Family Residential A-O Agricultural Open APPLICANT: Wallace Phillips IV, 3-D Development, LLC PROJECT MANAGER: Matt Robinson, AICP, Senior Planner mrobinson@cstx.gov RECOMMENDATION: The revised Preliminary Plat alters the phase boundariesfrom what was originally approved. Section 201 has been altered to remove the loop street and create an additional cul-de-sac. Additionally, the common area in this phase has been reduced and the overall changes result in the addition of two lots to the development. Staff recommends approval of the Preliminary Plat. Planning & Zoning Commission Page 1 of 4 March 1, 2012 DEVELOPMENT HISTORY Annexation: 1995 Zoning: A-O Agricultural Open (upon annexation) to A-0 Agricultural Open and R-1 Single Family Residential (2007); A-O Agricultural Open to A-O Agricultural Open, R-1 Single Family Residential and R-1 B Single Family Residential for 6.86 acres (2011) Site development: Section 200 has been Final Platted and has homes currently under construction. COMMENTS Water: The subject tract is located adjacent to an 8-inch water line extending from the existing Castlegate Development. Per the City's Master Utility Plan there is a series of water mains that will need to be extended with the development of this tract. Sewer: The subject tract is located adjacent to a 12-inch sanitary sewer line extending from the existing Castlegate Development. Per the City's Master Utility Plan there is a series of sanitary sewer mains that will need to be extended with the development of this tract. Off -site Easements: None known atthis time. Drainage: The subject tract is located in the Spring Creek Drainage Basin. Development of the subject tract will be required to meet the City's Storm Water Design Guidelines. The subject development is proposing two storm water detention facilities, which are to be located in the 5.13 and 6.14 acre common areas. These Common Areas are to be owned and maintained by the Home Owners Association for the subdivision. The 5.13 acre detention facility was constructed with the initial phase of the development, Section 200. Flood Plain: The subject tract is encroached by a FEMA Regulated Special Flood Hazard Area, Zone AE per FEMA FIRM Panel 205D. The subject area is to be contained within a common area. The subject area will also be adjacent to a 1.84 acre city park. These areas were final platted with Section 200 of the development. Greenways: The stream corridor, Spring Creek Tributary 7.1, begins on the subject tract and is identified in the Bicycle, Pedestrian, and Greenways Master Plan as a greenway. Pedestrian Connectivity: Sidewalks are required and will be provided on all thoroughfares and local streets except along cul-de-sacs. In addition, sidewalks are proposed to be provided in designated common areas throughout the development. Bicycle Connectivity: Bike lanes are required and will be provided along Victoria Avenue, Etonbury Avenue and W.S. Phillips Parkway. Planning & Zoning Commission Page 3 of 4 March 1, 2012 Streets: The subject tract will take access to Victoria Avenue (Major Collector) and Greens Prairie Road (Minor Arterial). Per the City's Thoroughfare Plan there will be thoroughfares required to be extended with the development of this tract. Per the Preliminary Plat these include W.S. Phillips Parkway (4 Lane Major Collector), Victoria Avenue (2 Lane Major Collector), and Etonbury Avenue (2 Lane Major Collector). Oversize Request: Oversized participation has been discussed informally with the applicant. Specific details will be discussed with future Final Plat submittals. Parkland Dedication: Land dedication of 5.6 acres and neighborhood park development fees and community park dedication and development fees were provided with the first Final Plat of the subdivision. Neighborhood park development fees and community park dedication and development fees of $1,707 per dwelling unit for the 582 lots will be required at the time of final platting. Neighborhood and community park land dedication and development fees of $2,021 per dwelling unit will be required for the 2 additional lots created. Impact Fees: The subject tract is located in the Spring Creek Sanitary Sewer Impact Fee Area and will be assessed $98.39 per LUE. REVIEW CRITERIA 1. Compliance with Comprehensive Plan and Unified Development Ordinance: The revised Preliminary Plat alters the phase boundaries from what was originally approved. Section 201 has been altered to remove the loop street and create an additional cufde-sac. Additionally, the common area in this phase has been reduced and the overall changes result in the addition of two lots to the development. Section 200 has been final platted and is shown for reference only. The proposed revised Preliminary Plat is in compliance with the Unified Development Ordinance and the requirements under the R-1 and R-1 B zoning designations. 2. Compliance with Subdivision Regulations: The Preliminary Plat is in compliance with the Subdivision Requirements of the Unified Development Ordinance. STAFF RECOMMENDATION Staff recommends approval of the Preliminary Plat. SUPPORTING MATERIALS 1. Application 2. Copy of Preliminary Plat (provided in packet) Planning & Zoning Commission Page 4 of 4 March 1, 2012