HomeMy WebLinkAboutStaff Report(*Orq"
CITY OF COLLL;GF. STATION
Horne of Texas Ad-M Universit!'
REZONING REQUEST
FOR
THE PLAZA AT COLLEGE STATION
12-00500063
REQUEST: C-1 General Commercial to PDD Planned Development District
SCALE: Approximately 0.2 acres
LOCATION: 1405 University Drive, generally located at the northwest corner of
the intersection of the former Meadowland Street
APPLICANT: Mitchell & Morgan, LLP, agent for owner
PROJECT MANAGER: Jason Schubert, AICP, Principal Planner
jchubert@cstx.gov
PROJECT OVERVIEW: This request incorporates this small property into the adjacent 11-
acre PDD Planned Development District rezoning that was
approved by City Council on March 8, 2012. It is proposed to
continue the same project and incorporate the same design
considerations and modifications as the approved PDD.
RECOMMENDATION
Staff recommends approval of the request.
Planning & Zoning Commission
May 3, 2012
Page 1 of 10
Planning & Zoning Commission Page 2 of 10
May 3,2012
00
Planning 8Zoning Commission
May 3'2012
Page 3 of 10
NOTIFICATIONS
Advertised Commission Hearing Date: May 3, 2012
Advertised Council Hearing Dates: May 24, 2012
The following neighborhood organizations that are registered with the City of College Station's
Neighborhood Services have received a courtesy letter of notification of this public hearing:
Property owner notices mailed:
Contacts in support:
Contacts in opposition:
Inquiry contacts:
ADJACENT LAND USES
I=
2
None
None at the time of staff report.
None at the time of staff report.
Direction
Comprehensive Plan
Zoning
Land Use
Northwest
Urban &
PDD Planned
Former Plaza Hotel
Redevelopment
Development
site to be demolished
Northeast
Urban &
PDD Planned
Former Plaza Hotel
Redevelopment
Development
site to be demolished
Texas A&M University
C-U College and
Southeast
(across University
University
Texas A&M polo field
Drive, major arterial
Urban &
PDD Planned
Former Kettle site,
Southwest
Redevelopment
Development
building has been
demolished
DEVELOPMENT HISTORY
Annexation: 1939
Existing Zoning: C-1 General Commercial
Final Plat: Gorzycki Meadowlands (1936) and portion of former Meadowland
Street that has been abandoned.
Site development: Developed as smoke shop that is to be demolished.
RELATION TO ADJACENT PDD PLANNED DEVELOPMENT DISTRICT
This request incorporates this small property into the adjacent 11-acre PDD Planned
Development District rezoning that was approved by City Council on March 8, 2012. It is
proposed to continue the same project and incorporate the same design considerations and
modifications. As proposed by the applicant, this report considers this property part of the larger
PDD so the description and evaluation provided below is similar to the previous request.
Planning & Zoning Commission Page 4 of 10
May 3, 2012
REVIEW CRITERIA
1. Consistency with the Comprehensive Plan: The subject property is designated as Urban
and part of Redevelopment Area II on the Comprehensive Plan Future Land Use and
Character Map. The intersection of Texas Avenue and University Drive has also been
identified as a Primary Arrival Gateway into the City. The Comprehensive Plan describes
Urban as:
This land use designation is generally for areas that should have a very intense
level of development activities. These areas will tend to consist of townhomes,
duplexes, and high -density apartments. General commercial and office uses,
business parks, and vertical mixed -use may also be permitted within growth and
redevelopment areas.
Redevelopment Area II: Texas Avenue, University Drive, and Harvey Road is described by
the Comprehensive Plan as:
This area includes a number of underperforming land uses that, due to their
proximity to two of the busiest corridors in the City, are poised for redevelopment.
Much of the area is currently subdivided into small lots, making it difficult to
assemble land for redevelopment .... The proximity of existing neighborhoods and
the Texas A&M University campus requires careful site planning and appropriate
building design. These efforts should be complimentary to the Area V: Hospitality
corridor plan, the neighborhood plan for the Eastgate area, and the Texas A&M
University Campus Master Plan and should focus on bringing vertical mixed use
and other aspects of urban character to this portion of the City.
The proposed PDD zoning with associated Concept Plan incorporates this small property
into a larger mixed use development that is consistent with the objectives of the
Comprehensive Plan to redevelop and consolidate underperforming properties in this area
of the City. The requested rezoning proposes to provide vertical mixed use, high density
multi -family, and pedestrian oriented development at the corner of Texas Avenue and
University Drive in proximity to the Texas A&M University campus.
2. Compatibility with the present zoning and conforming uses of nearby property and
with the character of the neighborhood: The existing zoning and conforming uses of
nearby property are consistent with the proposed uses. The scale of the proposed uses,
however are intended to be developed at a high density and more intensity than the nearby
residential, hotel and restaurant uses. The neighboring developments are developed on
more of a suburban scale with surface parking lots and open space while the proposed
development utilizes structured parking and has requested reduced setbacks and increased
density allowances.
3. Suitability of the property affected by the amendment for uses permitted by the
district that would be made applicable by the proposed amendment: The proposed
PDD Planned Development District proposes to incorporate this small property into a vertical
mixed use development with a mixture of commercial and multi -family uses. These uses are
suitable for the property based on its location within the core of the City and proximity to the
Texas A&M University campus. The scale and density of the development factor into the
availability of transportation and utility capacity in the area. As described later, the proposed
development proposes some transportation improvements and mitigation efforts and
Planning & Zoning Commission Page 5 of 10
May 3, 2012
acknowledges that utility upgrades will be necessary to provide adequate services to the
development.
4. Suitability of the property affected by the amendment for uses permitted by the
district applicable to the property at the time of the proposed amendment: The C-1
General Commercial district should be considered a suitable district for the property though
due to its size limits large-scale redevelopment.
5. Marketability of the property affected by the amendment for uses permitted by the
district applicable to the property at the time of the proposed amendment: Most of the
properties should be considered marketable with their current zoning, though the presence
of this small property constrains the potential for large-scale redevelopment opportunities.
6. Availability of water, wastewater, stormwater, and transportation facilities generally
suitable and adequate for the proposed use: The existing site is served by 8-inch water
line along the former Meadowland Street and 12-inch along University Drive. Per
discussions with the applicant, additional information will be needed through fire
demand modeling on existing available capacity. Once this has been analyzed by the
applicant, the City can better understand the proposed locations, potential required up -
sizing, and the potential required re -alignment of existing waterlines within/near the
proposed development.
The existing site is served by an 8-inch gravity sanitary sewer collection line along the
former Meadowland Street that flows to the existing Hensel Park Lift Station. This
respective lift station then pumps sanitary sewer flow to the 'Northeast Trunkline' via a 12-
inch force main. The 'Northeast Trunkline' conveys this flow to the Carters Creek
Wastewater Treatment Plant. Using the City of College Station's sanitary sewer modeling
software and the proposed build -out sanitary sewer demands submitted by the applicant,
the City has determined that there is not adequate capacity in the existing 8-inch sanitary
sewer line that spans from this respective development to the existing Hensel Park Lift
Station. The City has, however, concluded that there is existing available capacity in the
Hensel Park Lift Station/force main as well as the 'Northeast Trunkline'. Because of this, the
development would need to include off -site sanitary sewer improvements to provide
additional collection system capacity.
Drainage is generally to the south and west within the Wolf Pen Creek and Burton Creek
Drainage Basins, respectively. Stormwater and other public infrastructure improvements
required with site development shall be designed and constructed in accordance with the
BCS Unified Design Guidelines.
As part of the rezoning application for the adjacent PDD Planned Development District, a
Traffic Impact Analysis (TIA) was submitted. The TIA indicated that the intersection of
Texas Avenue and University Drive is operating at a Level of Service (LOS) E. Utilizing a
scale of LOS "A" thru LOS "F" with "A" being the best LOS "free flow traffic" and LOS F
being the worst LOS "bumper to bumper traffic" and LOS "D" being the acceptable LOS the
intersection is operating at unacceptable LOS. With that in mind the goal was to provide
mitigation strategies that would not prevent the intersection of University Drive and Texas
Avenue operate at a worse LOS. The following mitigation strategies were identified:
An additional left turn bay will be added to University Drive eastbound to northbound
Texas Avenue, creating a dual left configuration by modifying the existing raised median.
Planning & Zoning Commission Page 6 of 10
May 3, 2012
• On University Drive, a right turn deceleration lane for the proposed driveway will be built
to meet TxDOT design criteria. The raised median on Texas Avenue will also be
extended north beyond the proposed driveway location. These mitigation items are at
the request of TxDOT and concurred by City staff.
• Both the Brazos Valley Transit District and TAMU Transit have indicated that they would
not alter their routes to provide service within the proposed site. However, both transit
providers have routes along University Drive and Texas Avenue. In order to mitigate
traffic at the intersection of University Drive and Texas Avenue, staff has recommended
the applicant work with both transit providers regarding bus stops along University Drive
and Texas Avenue in close proximity to the proposed site. Furthermore, pedestrian and
bicycle accommodations within the site be provided and directed toward the transit
areas.
• The former Meadowland Street intersection at University Drive and the existing median
break in University Drive closed. This is at the direction of TxDOT and concurred by City
staff.
• To meet block length requirements, one projection westbound to TAMU property west of
the proposed site has been provided. Ultimately this would also serve as an alternative
route to University Drive and Texas Avenue, somewhat relieving traffic at that
intersection. It is anticipated that TAMU property will be redeveloped to include
commercial, retail, and residential uses.
• An additional right turn lane will be provided on southbound Texas Avenue to westbound
University Drive. Room for the construction of the second right turn lane is available with
the proposed 7.5-foot right-of-way dedication along Texas Avenue.
SUMMARY OF CONCEPT PLAN
The requested rezoning and associated Concept Plan incorporates this small property into the
adjacent vertical mixed use and multi -family redevelopment at the intersection of Texas Avenue
and University Drive. The vertical mixed use area consists of more than 60,000 gross square
feet of ground floor general commercial uses with multi -family units above. The multi -family area
consists of multi -story buildings oriented along the side and rear of the development along the
former Meadowland Street. The applicant proposes building heights ranging up to 70 to 80 feet
or eight stories. The development is proposed in two phases with the vertical mixed use and
some of the multi -family buildings, including this property, developed in the first phase with the
remainder of multi -family areas along the former Meadowland Street and Hensel Street in the
second phase. For the most part, parking will be provided in three proposed parking garages
located in different areas of the development. All existing buildings in both phases, including the
former Plaza Hotel tower, will be demolished before a building permits will be issued for new
construction.
The development will use the dimensional standards of the C-1 General Commercial zoning
district for the commercial uses and R-6 High Density Multi -Family zoning district for the
residential uses. Additional description, standards and improvements by the development are
provided below.
Meritorious Modifications
This area is designated as a Redevelopment area in the Comprehensive Plan which
acknowledges some role for the City may be necessary to encourage redevelopment. Some
Planning & Zoning Commission Page 7 of 10
May 3, 2012
modifications result from the intended urban nature of the proposed development and some are
due to the suburban style of some of the applicable development regulations. The applicant is
requesting the following meritorious modifications or alternatives to standard ordinance
requirements:
1. Zoning District Standards — UDO Section 5.2 "Residential Dimensional Standards"
and Section 5.4 "Non -Residential Dimensional Standards": An increase to the maximum
residential unit density from 30 units per acre to 60 units per acre is proposed by the
applicant. While this increase in density can be supported, it is necessary to ensure that
adequate infrastructure and transportation facilities including vehicular, bicycle, and
pedestrian are provided for the development and surrounding area.
The applicant requests to reduce minimum building setbacks for the C-1 General
Commercial and R-6 High Density Multi -Family based zoning districts to 5 feet along all
property lines with the understanding that sufficient easements for utilities will be provided.
The standard building setbacks for these districts are 25-foot front setback, 7.5-foot side
setback, 15-foot side street setback, and 15-foot rear setback for the C-1 district and 20-foot
rear setback for R-6.
2. Use — UDO Section 6.2.0 "Use Table": The P-MUD Planned Mixed Use District is the
base zoning district for uses for the development with Health Care, Medical Clinic added as
a permitted use and Country Club, Duplex, Fuel Sales, Fraternal Lodge, Golf Course/
Driving Range, Parking as a Primary Use, Single -Family Detached, Sexual Oriented
Businesses, and Shooting Range (Indoor) uses removed from the permitted list.
3. Parking — UDO Section 7.2 "Off -Street Parking Standards": The applicant proposes the
standard shopping center ratio of 1 parking space per every 250 gross square feet of
commercial use (1:250), though not required to provide additional parking if more than 25%
of these areas are utilized as intense commercial uses. The applicant also proposes the
minimum residential parking requirement be reduced to one parking space per bedroom.
The current ordinance requires one space per bedroom for three and four bedroom units
though some additional parking is provided with one and two bedroom units (1.5 spaces/
bedroom). Also, up to 5% of the parking spaces in the garage may be compact parking
spaces. This parking reduction can be supported if sufficient transit, bicycle, and pedestrian
facilities are provided.
4. Transportation — UDO Section 7.3 "Access Management and Circulation", Section
8.2.G "Blocks", and Section 11.2 "Defined Terms"- Public Way: The applicant proposes
some modifications to transportation related requirements:
• Three driveways exist along Texas Avenue and six driveways along University Drive,
including the former Meadowland Street. Though the proposed Concept Plan
consolidates these to one driveway on Texas Avenue and one driveway on University
Drive, the proposed driveways do not meet minimum spacing standards. Also, driveways
along the proposed Public Ways do not meet spacing standards based on existing
conditions. The applicant requests the proposed spacing be acceptable.
• The maximum block length in Urban designated areas is 660 feet with a maximum block
perimeter of 2,000 feet. Based on the dimensions of this area, two public way projections
would be required along the Public Way Section C-C toward the Texas A&M System
property to the southwest. The applicant has proposed one Public Way projection near
the center of this length. Though the Texas A&M System has not been supportive of any
type of connection between the two developments, they are in the process of developing
a master plan for a private development of commercial, retail, residential, and other uses
which will be subject to similar requirements.
Planning & Zoning Commission Page 8 of 10
May 3, 2012
• Public Ways are defined with certain dimensional and design criteria. The applicant
requests to reduce the maximum curve radius from a 200-foot radius to a 45-foot radius,
allow sidewalks to be back of curb instead of three feet off and have sidewalk widths as
shown in the attached cross sections. Also, the pedestrian facilities for the Public Way
projection to the Texas A&M University System property may be located through the
nearby amenity area.
5. Signs — LIDO Section 7.4 "Signs": Instead of using this Section as the basis for signage,
the applicant proposes to utilize the signage permitted in Wolf Pen Creek (UDO Section
5.6.A.11 Signs) with the following modifications:
• Signs may be approved administratively by staff with appeals to staff's interpretations
being able to considered by the Design Review Board;
• Wayfinding signage (UDO Section 7.4.AA Campus Wayfinding Signs) is permitted for
this development; and
• Projections signs may be used for identification signage for the general area and not
count against the attached signage square feet unless they contain copy of the individual
business. Projection signs may be oriented toward the public rights -of -way or public
ways and one permitted per tenant per public way frontage.
6. Landscaping — UDO Section 7.5 "Landscaping and Tree Protection": Instead of using
this Section as the basis for landscaping, the applicant proposes to utilize the Northgate
standards contained in LIDO Section 5.6.B.9 "Landscape and Streetscape Standards' with
the following modifications:
• The street trees along Texas Avenue and University Drive may be placed outside of
TxDOT right-of-way. Street trees along Public Way Sections A -A and B-B shall be 50
feet on center with alternating planting areas spaced at 50 feet on center consisting of
non -canopy trees, hedges or seasonal plantings. The Public Way Section C-C will have
planting areas of 25 feet on center consisting of non -canopy trees, hedges, or seasonal
plantings;
• Building and Site Lighting shall still comply with LIDO Section 7.10 Outdoor Lighting
Standards; and
• The Street Lights section is not applicable as lights are owned and maintained by
property owner.
7. Architecture — UDO Section 7.9 "Non -Residential Architecture Standards": Instead of
using this Section as the basis for architecture standards, the applicant proposes to utilize
the Northgate standards contained in UDO Section 5.6.B.4 "Building Design Standards"
except that residential dwelling units in a building with less than 12 units may have access
through a parking area or garage. All subsections (Building Orientation and Access, Building
Transparency, Architectural Relief, Roof Type, Exterior Building Material, Exterior Building
Colors, and Canopies/Awnings) shall apply to all non-residential and residential buildings.
8. Infrastructure — Section 3.3.A "Applicability": The applicant proposes a modification to
the platting requirement. Most of the property is platted though a couple areas are still tracts
of land. The applicant has requested that building permits may be issued on these tracts
prior to platting with the provision that a temporary blanket easement be placed on the
property and the property platted/replatted once all utilities are constructed and relocated
and before Certificates of Occupancy are issued for the buildings.
Planning & Zoning Commission Page 9 of 10
May 3, 2012
Community Benefits and Additional Enhancements
The applicant has identified the following community benefits, additional enhancements or
improvements:
1. Implementation of the Comprehensive Plan through redevelopment of an underperforming,
blighted area that is designated as a Primary Arrival Gateway and described by the
Comprehensive Plan as an area that should "focus on bringing vertical mixed -use and other
aspects of urban development to this portion of the City." All existing buildings will be
demolished before building permits will be issued for any new construction.
2. The Northgate Building Design Standards (UDO Section 5.6.B.4) apply to all buildings,
residential and non-residential. Currently there are no architectural requirements for
residential buildings outside of the Northgate District.
3. The Northgate Bicycle Parking Standards (UDO Section 5.6.B.7) apply to the development
except that the design of the bicycle rack design is determined by the owner and approved
by the City and bicycle parking may be located within the parking garage areas. Currently
there are no bicycle parking (bike rack) requirements for residential developments outside of
the Northgate District.
4. To promote transit usage, installation a bus stop shelter as approved by the City in a
location for TAMU Transit bus service, if provided, and another along University Drive to
utilize District bus service. Bus stops or bus shelters are not required by standard ordinance.
5. The Northgate Dumpster and Mechanical Equipment Standards (UDO Section 5.6.13.10)
shall apply with the exception that vegetation may also be used as a screening tool.
6. The Northgate Outside Storage and Display Standards (UDO Section 5.6.B.13) shall apply
to the development.
7. The parking garage on Texas Avenue is wrapped with general commercial use on ground
floor and residential above and the other parking garages along the former Meadowland
Street are wrapped with multi -family uses along the Public Way.
8. An eight -foot bicycle and pedestrian route is proposed along the southwest property line to
connect multi -family buildings and two parking garages to the University Drive sidewalk to
facilitate bicycle and pedestrian movements from the development toward the Texas A&M
University campus.
9. As permitted by TxDOT, mitigation for the Texas Avenue and University Drive intersection is
proposed through a variety of transportation improvements including the intersection and
median break for the former Meadowland Street will be closed, a dual left turn lane on
University Drive eastbound to Texas Avenue northbound and queue length extended, a dual
right turn lane on Texas Avenue southbound to University Drive westbound, multiple
driveways will be consolidated into one driveway on Texas Avenue and one driveway on
University Drive, the median on Texas Avenue will be extended north past the proposed
Public Way driveway, and a deceleration lane will be added to the proposed Public Way
driveway on University Drive.
STAFF RECOMMENDATION
Staff recommends approval of the request.
SUPPORTING MATERIALS
1. Application
2. Rezoning Map
3. Concept Plan
Planning & Zoning Commission Page 10 of 10
May 3, 2012