Loading...
HomeMy WebLinkAboutStaff CommentsTO: FROM: SUBJECT: CITY OF COLLEGE STATION Home of TexmAdM ry Univent ' �1101 Texas Avenue, P.O. Box 9960 College Station, Texas 77842 Phone 979:764.3570 / Fax 979.764.3496 MEMORANDUM December 16, 2011 t / Natalie Ruiz, IPS Group, via email: Natalie@ipsgroup.us V Matt Robinson, AICP, Senior Planner CHIMY'S CERVECERIA (SP) Thank you for the submittal that completes your SITE PLAN - COMMERCIAL application. This project will be distributed to staff next week for their review. cc: Chad Baccus, via email: chad(a)chimvs.com Chris Sagura, Paul Anthony & Associates, LLC via email: chris paulanthon asso .con f/ Veronica Morgan, Mitchell & Morgan, LLP via email: v mitchellandmor an.c Case file no. 11-00500196 Case file no. 11-00500197 STAFF REVIEW COMMENTS NO. 1 Chimy's Cerveceria - NG Review 11-00500197 PLANNING 1. The new kitchen cooler should be calculated as part of the building square footage. It must be included in the new second story addition and be shown on the exterior elevation drawings. Sheet A1.2 shows the cooler to be 238 SF in area. This addition will cause the project change to exceed the 50% threshold identified in Section 9.3 of the Unified Development Ordinance. The bathroom being added for ADA purposes does not have to be included in the square footage of change. Please revise. 2. Two architectural relief elements and a public entrance are required on the fagade facing Patricia Street. The wood on this fagade also exceeds the maximum of 20%. 3. The front elevation, facing University Drive, lacks one architectural relief element on the west side. 4. The wood on fagade A.2.Elevation 2 exceeds the maximum of 20%. 5. If railings are added, they must be decorative to comply with landscaping requirements found in Section 5.6.B.9.b of the Unified Development Ordinance. Please submit a picture of the proposed railing. 6. Shed roofs are prohibited in Northgate. Please reduce the slope to create a flat roof or select a different roof type. 7. Corrugated metal is not an approved roof material. Standing seam metal is an approved alternative that you may choose to utilize. 8. Please identify the material and color of the awnings. FYI... corrugate metal is not an approved material. 9. The existing columns on the side of the building appear to be steel. Since the fagade materials are being brought into compliance and steel is not an approved material (except for doors), the columns must be covered. 10. Transparency on the front fagade facing University Drive must be 50% and the Patricia Street fagade must be 30%. 11. Please add the following items to the materials legends: a. Total fagade square footage. b. Square footage and percentages for the colors being used. c. Percentage of each material and transparency per fagade. d. Square footage and percentage of metal used on each fagade. 12. Please add a note that all signage is permitted separately. lot for the 13. Please add a note that 203 University Drive shall be considered a building p purpose of signage, landscaping, and architectural requirements. Reviewed by: Lauren A. Hovde, Staff Planner Date: December 29, 2012