Loading...
HomeMy WebLinkAboutStaff ReportCITY OF COLLEGE STATION FINAL PLAT for Donald Eugene Sewell Estates Subdivision 11-00500191 SCALE: LOCATION: ZONING: APPLICANT: PROJECT MANAGER: Four lots on 0.4954 acres 205 Sterling Street R-1 Single -Family Residential Adam Wallace, ATM Surveying Lauren A. Hovde, Staff Planner Ihovde@cstx.gov RECOMMENDATION: Staff recommends approval of the waiver requests to lot area and lot width. If all waiver requests are approved, Staff recommends approval of the Final Plat. If any waiver request is denied, the Final Plat must be denied. Planning & Zoning Commission March 1, 2012 Page 1 of 5 Planning & Zoning Commission Page 2 of 5 March 1. 2012 DEVELOPMENT HISTORY Annexation: May 1969 Zoning: R-1 Single -Family Residential upon Annexation Preliminary Plat: There is no Preliminary Plat on file for the subject tract. Final Plat: The subject tract is considered a single building plot according to Section 8.2 of the Unified Development Ordinance. There is no previous Final Plat on records for this property. Site Development: A single-family house currently exists on the property. COMMENTS Parkland Dedication: Dedication will be assessed on the three newly established single- family lots for a total of $6,063. Greenways: No dedication is proposed with this plat. Pedestrian Connectivity: No connection is proposed or requested w ith this plat. Bicycle Connectivity: No connection is proposed or requested w ith this plat. Impact Fees: N/A REVIEW CRITERIA Compliance with Subdivision Regulations: Section 8.2.H.2 of the Unified Development Ordinance states that a plat involving a building plot created prior to June 1970, which creates an additional lot or building plot, must meet or exceed the average lot w idth within the block and each lot must be at least 8,500 square feet in area. The proposed Final Plat requires waivers to Section 8.2.1-1.2 of the Unified Development Ordinance, regard ing lot width standards and in inimum lot size requirements for platting in older subdivisions. The average lot width within the subject block is 81.31 linear feet. The average lot area within the block is 8,316. The four lots being created require the f ollowing waivers: Lot Number Proposed Lot Area Waiver Requested Proposed Lot Width Waiver Requested Lot 11A 5,394.81 SF 2,921 SF 51.63 feet 29.6 (feet Lot 11 B 5,394.81 SF 2,921 SF 51.63 feet 29.67 feet Lot 12A 5,394.81 SF 2,921 SF 51.63 feet 29.67 feet Lot 12B 5,394.81 SF 2,921 SF 51.63 feet 29.67 feet Planning & Zoning Commission Page 3 of 5 March 1, 2012 In accordance with the Subdivision Regulations, when considering a waiver, the Planning and Zoning Commission should make the following findings to approve the waiver: 1) That there are special circumstances or conditions affecting the land involved such that strict application of the provisions of this chapter will deprive the applicant of the reasonable use of his land; A special circumstance does exist for the property due to the large unplatted bui Iding plots in the block that skew the average lot width. For example, one unplatted bui Iding plot, closer to Texas Avenue, is currently vacant and contains approximately 208 feet of frontage. Of the 35 building plots within the block, 21 are approximately 50 feet in width. 2) That the waivers are necessary for the preservation and enjoyment of a substantial property right of the applicant; The waivers are not necessary for the property to further subdivide if fewer lots are yielded. The building plot may be divided into two platted lots and meet all minimum requirements. 3) That the granting of the waivers will not be detrimental to the public health, safety, or welfare, or injurious to other property in the area, or to the City in administering this chapter; and The granting of the requested waivers will not be detrimental to the public health, safety, or welfare, nor will they be injurious to other properties in the area, or to the City in administering this chapter. Many of the existing building plots and platted lots within the Richards Subdivision and Richards Addition Subdivision have a similar lot area and lot width as the proposed Final P lat. 4) That the granting of the waivers will not have the effect of preventing the orderly subdivision of other land in the area in accordance with the provisions of this chapter. The granting of the requested waivers will not affect the future orderly subdivision of property in the area. Much of the surrounding area was previously platted as the Richards Subdivision and Richards Addition Subdivision. The subject block, having been left out of the initial Richards Addition Subdivision, has developed consistently with the neighboring platted lots. The Urban land use designation, as shown on the Comprehensive Plan Land Use and Character Map, does provide guidance as to the i ntended future development of this area to be high -density residential. Further subdivision of the property could be a detriment to future lot consolidation for potential U rban-appropriate projects. STAFF RECOMMENDATIONS Staff recommends approval of the waiver requests to lot area and lot w idth. If all waiver requests are approved, Staff recommends approval of the Final Plat. If any waiver request is denied, the Final Plat must be denied. SUPPORTING MATERIALS Planning & Zoning Commission Page 4 of 5 March 1. 2012 1. Application 2. Copy of Final Plat (provided in packet) Planning & Zoning Commission Page 5 of 5 March 1, 2012