Loading...
HomeMy WebLinkAboutStaff Comments1101 Texas Avenue, P.O. Box 9960 College Station, Texas 77842 Phone 979.764.3570 / Fax 979.764.3496 11 _ EGYM-A Ni 31.1 1 O'V7) V December 5, 2011 / TO: Jennifer Fredericks, via email: Jennifer(o)Fen iferfreclericks.com V FROM: Jason Schubert, AICP Principal Planner SUBJECT: 1251 BARRON RD (NRA) Thank you for the submittal of your NON-RESIDENTIAL ARCHITECTURAL STANDARDS application. This project will be distributed to staff this week for their review. Please note that the landscape plan and irrigation plan submitted with this application will need to be included as part of the site plan application related to the driveway and parking improvements on the site. While some documents were submitted to the City a couple weeks ago, staff returned these documents to the submitter with the direction to resubmit them with a completed site plan application for the proposed improvements. The site plan application has not yet been submitted to the City for review. cc: Case file no. 11-00500186 �1 1101 Texas Avenue, P.O. Box 9960 College Station, Texas 77842 Phone 979.764.3570 / Fax 979.764.3496 Crry OI> CUI. ...GH STATION Homr JT A&N Unlnrmly. MEMORANDUM (� 1 December 8, 2011 TO: Jennifer Fredericks, jennifer@jenniferfredricks.com'a FROM: Morgan Hester, Staff Planner SUBJECT: 1251 Barron Rd NRA Review Staff reviewed the above -mentioned Non -Residential Architectural plans as requested. The following page is a list of staff review comments detailing items that need to be addressed. Please address the comments and submit the following information by any Monday at 10:00 a.m. for further staff review: One (1) revised set of elevation drawings Please note that this application will expire in 90 days from the date of this memo, if the applicant has not provided written response comments and revised documents to the Administrator that seek to address the staff review comments contained herein. If there are comments that you are not addressing with the revised elevations, please attach a letter explaining the details. If you have any questions or need additional information, please call me at 979.764.3570. Attachments: Staff review comments PC: John Rusk, via email: jrusk@goodwinlasiter.com Case file #11-00500186 STAFF REVIEW COMMENTS NO. 1 1251 Barron Rd (NRA) — NRA Review 11-00500186 PLANNING 1. Please note that the landscape plan has not been reviewed as it will be revised when a site plan application has been submitted. 2. Please resubmit the revised elevations without the brick detail. Also, please continue the hatching pattern of the proposed building material throughout the elevations and show the additional shutters. 3. Per the NRA Building Review Minimum Requirements, please provide the legal description of the site and the applicant's address. 4. Please provide a site location map for reference and building orientation. Rather than labeling the elevations "side elevation", please use the location map to indicate their locations. 5. Per UDO Section 7.9.8.2, two different architectural relief elements are required for every 45' section of facade facing the right-of-way and for every 60' section for sides not facing the right-of-way. It appears that two sides have added elements so the facade will need to come into compliance. Please provide and label these elements on the plan. 6. Per the conversation with Jason Schubert, two colors must be used on each facade. The shutters may count as the second color so shutters need to be provided on all facades or a second siding color would need to be added instead. 7. On the plan, please provide the following: • Legal description of site; • Applicant's address; • Site location map for reference and building orientation. Please use this to label elevations according to their location rather than titling them side elevation, front elevation, and back elevation; • Building's total square footage; • Material use percentages; • List of colors and use percentages. Reviewed by: Morgan Hester, Staff Planner Date: December 8, 2011 MEMO i • 111611 NA016 LOS j. •. Exterior Materials: Roof - existing steel roof Exterior siding - Hardi Plank Lap Siding - 8" x 12' planks Masonry accent - Boral Thin Brick Columns - 12"xl0' wood construction Windows - aluminum frame, double -paned, LowE glass Front doors - Two 8' fiberglass exterior doors Shutters - Severe Weather Vinyl shutters Back door - 6'8 fiberglass exterior door Color List: Exterior siding and columns - Sherwin Williams Snowbound (SW 7004) Shutters -Sherwin Williams Tricorn Black (SW6258) Front doors - Sherwin Williams Open Seas (SW 6500) Backdoor - Sherwin Willliams Snowbound (SW 7004) Window frame - white (from the factory)