HomeMy WebLinkAboutWastewater Design ReportDecember 22, 2011 Mr. Stephen Maldonado Jr. City of College Station Water Services Department 1101 Texas Avenue College Station, TX 77842 Re: Wastewater Design Report Brazos Fellowship Addition 226 Southwest Parkway East College Station, Texas Gessner Engineering Job No.: 11-0361 Dear Mr. Maldonado: The peak wastewater flow was calculated in accordance with the 2009 International Plumbing Code, Tables E103.3(2) and E103.3(3). The additional fixture unit count of 191.25 was determined for this building. The values are shown below in Table One. Fixture Number Load Factor Total Value Water Closet 13 10 130 Urinal 3 10 30 Lavatory 10 2 20 Shower 1 4 4 Sink 1 4 4 Sink Service 1 3 3 FDrinkinq Fountain 1 0.25 0.25 Total 191.25 Table One: Fixture Units Gessner Engineering The peak wastewater flow based on the fixture units is 90 gallons per 2501 Ashford Drive minute for 200 fixture units. Using the Manning equation with an n value of 0.013, the velocity in all sections of the proposed sewer line s""e'oz were calculated as shown in Table Two below. CollegeStadon,7exas 77840 Pipe Section Pipe Size (in) Pipe Slope (°/a) Pipe Capacity (gpm) Pipe Velocity (tus) Service Connection 6 2.3 382 4.33 CO. Box 10763, 77842-0763 979.680.8840 Table Two: Pipe Size, Slope and Velocity FAX 979.680.8841 2204 S. Chappell Hill St. Brenhatn.7exas 77833 979.836.6855 FAX 979.836.6847 All pipe slopes are within the required range of minimum/maximum pipe slopes for sanitary sewer from the Bryan/College Station Unified Design Guidelines. Please contact us if you have any questions or if we can be of further assistance. Sincerely, GESSNER E4GINV ING, F-7451 .E., C.F.M. G Gessner Engineering November 16, 2011 Mr. Stephen Maldonado Jr. City of College Station Water Services Department 1101 Texas Avenue College Station, TX 77842 Re: Wastewater Design Report Brazos Fellowship Addition 226 Southwest Parkway East College Station, Texas Gessner Engineering Job No.: 11-0361 Dear Mr. Maldonado: The peak wastewater flow was calculated in accordance with the fixture count determination method. The additional fixture unit count of 148 was determined for this building. This calculation was determined based on the fixture unit load factor given in Table I of the Sanitary Sewer Chapter of the Bryan/College Station Unified Design Guidelines. The values are shown below in Table One. Fixture Number Load Factor Total Value Water Closet 13 8 104 Urinal 3 4 12 Lavatory 10 2 20 Shower 1 3 3 Sink 1 4 4 Sink Service 1 3 3 Fountain 1 2 2 —Drinking Total 148 Table One: Fixture Units Gessner Engineering 2501 Ashford Drivc The peak wastewater flow based on the fixture units is 125 gallons per minute for less than 500 fixture units. Using the Manning equation with s""`'oz an n value of 0.013, the velocity in all sections of the proposed sewer College Station,'rexas 77840 line were calculated as shown in Table Two below. CO. Box 10763, 77842-0763 Pipe Section Pipe Size (in) Pipe Slope (%) Pipe Capacity (gpm) Pipe Velocity (ft/s) Senvice Connection 1 6 2.3 382 4.33 Table Two: Pipe Size, Slope and Velocity 979.680.9840 FAX 979.680.8841 2204 S. Chappell Hill St. Brenhatn,Tcxas 77833 979.836.6855 FAX 979.836.6847 All pipe slopes are within the required range of minimum/maximum pipe slopes for sanitary sewer from the Bryan/College Station Unified Design Guidelines. Please contact us if you have any questions or if we can be of further assistance. Sincerely, GESSNEVef-NgMEERING, F-7451 P.E., C.F.M. Kyle M. Zapalac, M.E., E.I.T. r: JEREMY N. 7 o.- 100217 0 Gessner Engineering