Loading...
HomeMy WebLinkAboutStaff Comments1101 Texas Avenue, P.O. Box 9960 College Station, Texas 77842 Phone 979.764.3570 / Fax 979.764.3496 September 22, 2011 / TO: Mitchell & Morgan, Veronica Morgan, via email: v(a)mitchellandmorgan.com�/ FROM: Jason Schubert, AICP Senior Planner SUBJECT: LAKERIDGE TOWNHOMES PH 2B (SP) Thank you for the submittal of your SITE PLAN - RESIDENTIAL application. This project will be distributed to staff next week for their review. cc: Lakeridge Living, via email: 0imbstewartCa.omail.com� Case file no. 11-00500148 1101 Texas Avenue, P.O. Box 9960 College Station, Texas 77842 Phone 979.764.3570 / Fax 979.764.3496 Crrr Or COu.RCR STATION eo,,­ fT. A&nr u„ wiq MEMORANDUM October 5, 2011 TO: Veronica Morgan, Mitchell & Morgan, LLC, via email: v(o)mitchellandmorgan.com FROM: Morgan Hester, Staff Planner SUBJECT: Lakeridge Townhomes Ph 2b (SP)- Site Plan Staff reviewed the above -mentioned site plan as requested. The following page is a list of staff review comments detailing items that need to be addressed. Please address the comments and submit the following information by any Monday at 10:00 a.m. for further staff review: City of College Station Transmittal Letter; Memo providing written responses to all of staff's comments (identify the specific page that each comment was addressed on or the reason for not addressing the comment); Seven (7) complete sets of site civil construction documents for the proposed development with the revised site and landscaping plans attached (one set will be returned to you, please submit additional copies if you want more than one approved set); Two (2) revised site plans; One (1) landscaping plan; One (1) 11x17 grading and erosion control plan; Easement Dedication Sheet and required documents (please note that the Site Plan will not be stamped approved until the Blanket Easement, or all other appropriate easements, have been dedicated to the City of College Station). OR Four (4) revised site and one (1) landscaping plan; $44,442 Parkland Dedication fees prior to issuance of a building permit; Easement Dedication Sheet and required documents (please note that the Site Plan will not be stamped approved until the Blanket Easement, or all other appropriate easements, have been dedicated to the City of College Station). Please note that this application will expire in 90 days from the date of this memo, if the applicant has not provided written response comments and revised documents to the Administrator that seek to address the staff review comments contained herein. If there are comments that you are not addressing with the revised site plan, please attach a letter explaining the details. If you have any questions or need additional information, please contact Morgan Hester at 979.764.3570. Attachments: Staff review comments PC: Lakeridge Living, via email: 0imbstewart(a)gmail. com Case file #11-00500148 STAFF REVIEW COMMENTS NO. 1 Project: Lakeridge Townhomes Ph 2b (SP) — 11-00500148 PLANNING 1. If ramps are provided in front of building 20, please indicate with labeling. 2. Please make permanent changes to notes about water and sanitary demands on the Overall Layout and Site Plan. 3. It appears that there are several handicapped ramps that do not have a connection to surrounding sidewalks or other infrastructure. Please explain. 4. As an FYI, if the privacy fence separating Phase 213 and Phase 1 D is taller than 8', a building permit will be required. 5. Please note that any changes made to the plans, that have not been requested by the City of College Station, must be explained in your next transmittal letter and "bubbled" on your plans. Any additional changes on these plans that the City has not be made of aware of will constitute a completely new review. Reviewed by: Morgan Hester, Staff Planner Date: October 3, 2011 LANDSCAPING/STREETSCAPING/BUFFER 1. At building 20, the count for Dwarf Buford Holly is incorrect. Also, the total number of Snow White Indian Hawthorns in the Landscape Schedule is not correct. Please revise both. 2. Please revise the Landscape Schedule to show that Belinda's Dream Rose is worth 10 points. 3. The required points needed for canopy trees for this phase is lacking by 38. Please provide additional Reviewed by: Morgan Hester, Staff Planner Date: October 3, 2011 MISCELLANEOUS 1. Irrigation system must be protected by either a Pressure Vacuum Breaker, a Reduced Pressure Principle Back Flow Device, or a Double -Check Back Flow Device, and installed as per City Ordinance 2394. 2. All BackFlow devices must be installed and tested upon installation as per City Ordinance 2394. Page 3 of 5 ENGINEERING COMMENTS NO. 1 1. Please submit a cost estimate and NOI. 2. FYI... Additional Development Permit Fee in the amount of 1% of the total public infrastructure cost may be required (if that amount exceeds the minimum $600). 3. FYI ... All sheets (excluding standard details) need to be sealed by the design engineer. 4. Water Report - Please provide a paragraph indicating the required fire flow per building per the International Fire Code. 5. Please submit PUE dedication application. FYI ... This easement will need to be dedicated prior to issuance of CO. 6. Sh.02 - Please move the private storm sewer inlet on the northern side of the phase out of the PUE. 7. Sh.02 - General Note #2 should reference the 2009 BCS Guidelines. 8. Sh.02 - Please add a note stating the building material type, square footage, and required fire flow. 9. Sh.02 - Please show and label all proposed PUEs. 10. Sh.02 - Please label all FDCs, isolation valves, and meters. 11. Sh.03 - Please label top -of -pavement flowlines at curb inlets. 12. Sh.03 - Please provide inlet protection at the Phase 2A curb inlet adjacent to this section. 13. Sh.05 - Can the fire and domestic lines serving Building 19 be shortened so that the PUE doesn't need to cross the sidewalk? 14. Sh.05 - Can the fire and domestic lines serving Building 29 be moved to the nearby median? 15. Sh.05/06 - Please maintain 18 inches of vertical separation between water lines and electrical conduit. 16. Sh.05/06 - Please remove FDCs from PUEs where possible. 17. Sh.05/06 - Verify that all water infrastructure, including fire hydrants, are at least 5.5-ft from the edge of PUEs. 18. Sh.06 - Where the waterline crosses the sanitary sewer, please note the separation distance and TCEQ requirements for water/sewer crossings. 19.Sh.06 - WL "B" and WL "H" may have stub -outs for future water service, but water meters should not be added until the future buildings are being site planned. Reviewed by: Erika Bridges Date: 10/5/11 ELECTRICAL COMMENTS REQUIRING IMMEDIATE ATTENTION 1. Some easements on site are existing. Electric facilities will be designed within existing easements. 2. Developer provides temporary blanket easement for construction purposes or provides descriptive easements for electric infrastructure as designed by CSU for electric lines. 3. Developer may be responsible for locating easements on site to insure that electrical infrastructure is installed within easement boundaries. 4. Conduit routing is not per our design and therefore not acceptable. See note 1 below. GENERAL ELECTRICAL COMMENTS 1. Developer installs conduit per CSU specs and design. 2. CSU will provide drawings for electrical installation. 3. Developer provides 30' of rigid or IMC conduit for riser poles. CSU installs riser. 4. Developer will intercept existing conduit at designated transformers or other existing devices and extend as required. 5. If conduit does not exist at designated transformer or other existing devices, developer will furnish and install conduit as shown on CSU electrical layout. 6. Developer pours electric device pads or footings (i.e. transformers, pull boxes etc) per CSU specs and design. 7. Developer installs pull boxes and secondary pedestals per CSU specs and design (pull boxes and secondary pedestals provided by CSU). 8. Developer provides digital AutoCAD 2000 or later version of plat and / or site plan. Email to: gmartinez@cstx.gov, sweido@cstx.gov, or ehorton@cstx.gov. 9. Developer provides load data to CSU as soon as it is available to avoid construction delays. Delivery time for transformers not in stock is approximately 40 weeks. 10. Final site plan must show all proposed electrical facilities necessary to provide electrical service, i.e. transformer(s), pull box(es), switchgear(s), meter location and conduit routing as designed by CSU. 11.To discuss any of the above electrical comments please contact Sam Weido at 979.764.6314. Reviewed by: Sam Weido SANITATION Date: 9-30-11 1. The 2-12'x12' Dumpster Pad on the southwest end near bldg. 25 needs to be turned 15 degrees clockwise in order to have a clear maneuvering path. Reviewed by: Wally Urrutia Date: September 28, 2011 91400900-44# aN aseO /�woo•!!ew }aenna;sw!, :l!ewa e!n.'dl 6ulnll 96p!a9Ael :00 s;uawwo0 nna!n;sa }}e;S :s;uawyoe;;y 'OL9£179L'6L6 le aw Ileo aseald 'uo!;ewao}ui leuo!;!ppe paau ao suo!;sanb Aue aney noA 11 -sgajap ay; 6u!u!eldxe aa;;al a yoe;;e aseald 'ueld a;!s pas!naJ ay; y;!M 6u!sseippe;ou aae noA;ey; s;uawwoo We 9aa4111 •uiaaay paule;uoo s;uawwo0 Malnaa }}e;s ay; ssaippe o; Maas;ey; ao;ea;slulwpy ay} o; s;uewnoop paslnaa pue s;uawwoo asuodsai ua;;uM pap!noad;ou sey;ueo!ldde ay;;! 'owaw sly;;o a;ep ay} woad sAep 06 u! aa!dxa 11!M uo!;eopdde sly;;ey; a;ou aseald weld 6u!deospuel (4) auo pue a;!s paslnaa (b) anod ENS (;!waad ;uawdolanaO jo aouenssi o; joud and) 6810Z$ ;o aoueleq 891 ;!waad ;uawdolanaO ueld loa;uoo uo!soaa pue 6u!pei6 L4x44 (4) eu0 ueld 6u!deospuel (4) au0 sueld a;!s pas!naa (b) anod (;as panadde auo uey; aaow ;ueM nog( ;! sa!doo leuo!;!ppe ;!wgns aseald 'nog( o; pauin;aa aq II!M ;as auo) payoe;;e sueld 6u!deospuel pue a;!s pas!Aaa ay; Ll;!M ;uawdolanap pasodoid ay} jo; s;uawnoop uo!;ona;suoo I!n!0 a;!s ;o s;as a;aldwoo (L) uanaS Ja;;al lepwsueal uo!;e;S 9691100;o A;!O :Malnaa }}e;s jegpn;ao; -w-e 00:04;e Aepuolnl Aue Aq uo!;ewao;u! 6u!Mopo; ay};!wgns pue s;uawwo0 ay} ssaJppe aseald •sMalnaa (£) aaay; jo;as;uanbasgns ay; aol pe;;!wgns aq o; paau lip eel 6u!ssaooid Z£6$ aay;oue 'Ie;;!wgns;xau ay; uo passaippe uaeq;ou aney swat! pe;l 'sMalnaa }o punoi sly; ao; gels Aq MalnaJ leu1; pue pa!y; ay; aq lip le;;!wgns ;xau ayl 'passaippe aq o; peau ;ey; swat! 6u!I!e;8p s;uawwoo Ma!naJ ;;e;s }o;s!l a si abed bu!Mollo; ayl •pa;senbei se ueld ap pauoi;uaw-anoge ay; paMalnaa Me;S Ueld aMS - (dS) 8Z 4d sauao4UMO.L a6plaa)Ie-I :103rens Jauueld Me;S 'aa;saH ue6aoW :WOad 0 1) �wo0-ue6Jowpue!l8y0;!w@a n :l!ewa eIn 'dll 'ue6JoW �g I19401!W :Ol Il " kt 0� 4 40Z 't4Z aago;00 wnUNVUOW3W ,41w+rnll tt'PV mgil° ourgt NOISVlS 11011'I'10D dO A.LID 96b£'49L'6L6 Xed / OLS£'ti9L'6L6 auoyd v� Zb9LL sexal 'uo!;e;S 9691100 0966 x08 'O'd 'anuany sexal 404 STAFF REVIEW COMMENTS NO. 2 Project: Lakeridge Townhomes Ph 2B (SP)-11-00500148 PLANNING 1. Please note that any changes made to the plans, that have not been requested by the City of College Station, must be explained in your next transmittal letter and "bubbled" on your plans. Any additional changes on these plans that the City has not been made aware of will constitute a completely new review. Reviewed by: Morgan Hester, Staff Planner Date: October 17, 2011 LANDSCAPING/STREETSCAPING/BUFFER NO. 2 1. Please revise the Landscape Schedule to show the total extended points for Snow White Indian Hawthorn is 790. This will make the total number of landscape points required for the site 3,850. 2. Please note that any changes made to the plans, that have not been requested by the City of College Station, must be explained in your next transmittal letter and "bubbled" on your plans. Any additional changes on these plans that the City has not been made aware of will constitute a completely new review. Reviewed by: Morgan Hester, Staff Planner Date: October 17, 2011 SANITATION Repeat: The 2-12'xl2' Dumpster Pad on the southwest end near bldg. 25 needs to be turned 15 degrees clockwise in order to have a clear maneuvering path. Reviewed by: Wally Urrutia Date: October 24, 2011 'r 4-vl- PWW CITY OF COLLNGS. STATION Home ofTe xA&M University° MEMORANDUM March 13, 2013 TO: Veronica Morgan, Mitchell & Morgan, LLP; via email: v@mitchellandmorgan.co FROM: Morgan Hester, Staff Planner Lakeridge Townhomes Ph 2B (SP) - Site Plan Staff reviewed the above -mentioned site plan as requested. The following page is a list of staff review comments detailing items that need to be addressed. Please address the comments and submit the following information by any Monday at 10:00 a.m. for further staff review: City of College Station Transmittal Letter Parkland Dedication in the amount of $64,194 due prior to issuance of a building permit; One (1) revised site plan One (1) 1 1x1 7 grading and erosion control plan Please note that this application will expire in 90 days from the date of this memo, if the applicant has not provided written response comments and revised documents to the Administrator that seek to address the staff review comments contained herein. If there are comments that you are not addressing with the revised site plan, please attach a letter explaining the details. If you have any questions or need additional information, please call me at 979.764.3570. Attachments: Staff review comments PC: Lakeridge Living LP, via email: im�tewart(a)gmail. con� Case file #11-00500148 Planning & D"eloptnent Services P.O. BOX 9960 • ll 01 TEXAS AVF,NI-E • COI 7 1 GF STATIC)N - "TEXAS . 7'a42 'I EL, 47R 76435-0 - FAX. 979. 764,3496 cstx.govldevservices £ IOZ ' I I Wien :ale(] sebpu8 e� pu i :Aq PGM@IAGH -aoual ll!s pasodoad ay; lagel aseald '9 �sale6 pasodoad eql lagel pue Mogs aseald 'os 11 Zpa;eb aq of pasodoad peoa s!gl sl •q Zssaooe Aaeaodwal a se paz!pin eq of peled!o!lue peoa s!ql s! 6uol MOH -E 'ola 'I!elep paepuels '!!pea lagel aseald AeMaAlap le!oaawwoO e ao} spaepuelS !l!3 laaw of paa!nbaa si uollo@uuoo AeMaA!ap aql 'Z -euel aa!; se lagel aseald 'os;l LIIaM se 'auel aa!l se uoilounl peoa sigl IHAA ' I Z "ON S1N3WWO3 JNR133NIJN3 £ IOZ 'b gOaelN :ale4 £IOZ '17 goaeIN :alea £IOZ'8 goaeW :alea e!lnaan /flleM :Aq paMa!Aay sluawwOO ON 'I NOIIVIINVS op!aM weS :!q paMalAab u6!sep ano loalle lou saoa -I 3RI13313 aalsaH ue6aolN :Aq paMalAa�l -Ma1Aaa Mau Alalaldwoo a alnl!lsuoo II!M to aaeMe @pew uaaq lou seq Al!3 aql legl sueld asegl uo sabuego leuo!l!ppe Auy 'sueld anoA uo „pelggnq„ pue aallal lell!wsueal lxau anon( ui peu!eldxa aq lsnw 'uogelS a6allo3 }o fl!3 aql Aq palsanbaa uaaq lou aneq legl 'sueld aql of apew sabuego !ue legl a;ou aseald ' I `JNINMd-ld 8b100900-I I - (dS) 8Z qd sawoquMol a6p!aaWl :loafoad £ 'ON S1N3WWO3 M31A3M dd`d1S CITY OF COLLEGE STATION Home of7eras A&M University' MEMORANDUM July 31, 2013 TO: Veronica Morgan, Mitchell & Morgan, LLP; via email: v@mitchellandmorgan.com FROM: Morgan Hester, Staff Planner SUBJECT: Lakeridge Townhomes Ph 213 (SP) - Site Plan Staff reviewed the above -mentioned site plan as requested. The following page is a list items that need to be provided for stamping. Please submit the following by any Monday at 10:00 a.m. for further staff review: City of College Station Transmittal Letter Eight (8) complete sets of documents for the proposed development with, please submit additional copies if you want more than one approved set) Two (2) revised site plans One (1) 24 x 36 grading and erosion control plan Please note that this application will expire in 90 days from the date of this memo, if the applicant has not provided written response comments and revised documents to the Administrator that seek to address the staff review comments contained herein. If there are comments that you are not addressing with the revised site plan, please attach a letter explaining the details. If you have any questions or need additional information, please call me at 979.764.3570. Attachments: Staff review comments cc: Lakeridge Living LP; via email: jimbstewart@gmail.com Case file #11-00500148 Planning & Development Services P.O. BOX 9960 • t WI TEXAS AVENUE • COLLEGE STATION • TEXAS • 77842 TEL. 979.764.3570 - TAX. 979.764.3496 cstx.gov/devservices ;,DESIGN GROUP LANDSCAPE ARCHITECTURE 10-06-11 Morgan Hester, Staff Planner 1101 Texas Avenue, P.O. Box 9960 College Station, Texas 77842 Phone 979.764.3570 / Fax 979.764.3496 RE: Lakeridge Townhomes Ph 2b (SP)- Site Plan — Landscape Comments , LANDSCAPING/STREETSCAPING/BUFFER �i At building 20, the count for Dwarf Buford Holly is incorrect. Also, the total number of 1 Snow White Indian Hawthorns in the Landscape Schedule is not correct. Please revise both. Quantities adjusted. Please revise the Landscape Schedule to show that Belinda's Dream Rose is worth 10 points. Point value adjusted. 3. The required points needed for canopy trees for this phase is lacking by 38. Please provide additional Additional points provided. "To T W �O \ \vZ S v� b woWw H l c MISCELLANEOUS l \H se P V is ' Not sure about action required by city on these notes: fed �Q J VVC C Or'. .tD %S u� �! Irrigation system must be protected by either a Pressure Vacuum Breaker, a Reduced Pressure Principle Back Flow Device, or a Double -Check Back Flow 'Device, and installed as per City Ordinance 2394. MtA1-CS Note added to landscape plan. •tut W L 2f All BackFlow devices must be installed and tested upon installation as per City Pp\ NTS Ordinance 2394. Note added to landscape plan. 3 S 0 iD Thanks, RL DAP, CID 401 en Valley Drive Brya , TX 77802, 979-777-0065