HomeMy WebLinkAboutFinal Drainage StudySeptember 22, 2008 Ms. Erika Bridges City of College Station 1101 Texas Avenue College Station, Texas 77842 Re : Civil Engineering -Final Drainage Study Proposed Zeta Tau Alpha Sorority House 1403 Athens Drive College Station, Texas Gessner Engineering Job No.: 08-0071 Dear Ms. Bridges: Gessner Engineering was requested to conduct a drainage study for the proposed Zeta Tau Alpha Sorority house located in College Station , Texas. Based on the requirements within the Bryan College Station Unified Code 2008, Gessner Engineering utilized the Rational Method to conduct a comparison study on the existing and proposed drainage. The design was based on a 100 year frequency with an intensity of 8.14 inches per hour. A runoff coefficient used for impervious areas was 0.90 and 0.15 for grass or landscape areas. Based on final calculations comparing the proposed site to the existing, the proposed construction will not increase the impervious area. The proposed construction shall be a two story brick veneer structure with a footprint of approximately 10,600 square foot. The proposed site shall provide seventy-nine parking spaces, bicycle storage, sidewalks, and landscape islands. The existing three story brick veneer sorority house demolished had only a footprint of approximately 5,200 square foot. The existing site provided approximately only seventy-six parking space, sidewalks, and landscape. Considering the surrounding existing drainage and the minimal elevation drop across the site, Gessner Engineering choose to utilize an alternative parking system, Grasspave2, in multiple locations. This parking was utilized in areas that were anticipated to be used only once a week for meetings and other full sorority events. This would decrease the impervious area on the site and will decrease the existing outflow. After a complete comparison study and additional grass paving , the proposed new construction will decrease the outflow approximately 0.73 cubic feet per second (cfs) as presented in the table below (Table One). Based on this data, Gessner Engineering does not anticipate this development will adversely affect the existing G Gessner Engineering 1712 Southwest Pkwy Suite 105 College Station, Texas 77840 P.O. Box 10763, 77842-0763 979.680.8840 FAX 979.680.8841 2204 S. Chappell Hill St. Brenham, Texas 77833 979.836.6855 FAX 979.836.6847 G infrastructure and onsite detention is not required . For complete calculations please reference the drainage area maps on page C4.0 and C4.1. Total Proposed Impervious Area (acres): 0.75 (A2-A6, A19-A34) Total Existing Impervious Area (acres): 0.84 Total Increased Impervious Area (acres): -0.09 Total Proposed Impervious Area (acres) -Total Existing Impervious Area (acres) Total Proposed Outflow, Q (cfs): 5.84 100 year Total Existing Outflow, Q (cfs): 6.57 100 year Total Increased Outflow, Q (cfs): -0.73 100 year Table One: Summary Dramage Calculat1ons (Reference C4.1) We appreciate the opportunity to work with you on this phase of the project. We trust that this report is responsive to the requirements. Please contact us if you have any questions or if we can be of further assistance. Sincerely, GESSNER ENGINEERING Gessner Engineering