Loading...
HomeMy WebLinkAboutStaff Comments1101 Texas Avenue, P.O. Box 9969 l9- College Station, Texas 77842 C& Phone 979.764.3570 / Fax 979.764.3496 MEMORANDUM June 23, 2011 TO: David Scarmardo, via email: david(a)scarmardofoods.com FROM: Molly Hitchcock, AICP Planning Administrator SUBJECT: PANERA BREAD (SP, DP, and NRA) Thank you for the submittal of your SITE PLAN - COMMERCIAL application. This project will be distributed to staff next week for their review. cc: Kling Engineering & Surveying, via email: stewartCo)klingeng.com t! Case file no. 11-00500095 Case file no. 11-00500096 1101 Texas Avenue, P.O. Box 9960 College Station, Texas 77842 Phone 979.764.3570 / Fax 979.764.3496 CITY ON CO1.UGF. STATION Nome ofT AW UnhrcM,' MEMORANDUM July 1, 2011 1 Ill TO: David Scarmardo via email: david@scarmardofoods.com✓ FROM: Lauren A. Hovde, Staff Planner SUBJECT: Panera Bread - NRA Review Staff reviewed the above -mentioned Non -Residential Architectural plans as requested. The following page is a list of staff review comments detailing items that need to be addressed. Please address the comments and submit the following information by any Monday at 10:00 a.m. for further staff review: One (1) revised set of elevation drawings Color Samples Please note that this application will expire in 90 days from the date of this memo, if the applicant has not provided written response comments and revised documents to the Administrator that seek to address the staff review comments contained herein. If there are comments that you are not addressing with the revised elevations, please attach a letter explaining the details. If you have any questions or need additional information, please call me at 979.764.3570. Attachments: Staff review comments / cc: Kling Engineering &Surveying via email: stewartOkHngeng.fom✓ Kevin Wienke via email: KWienke(Lbdp3architects.com Case file #11-00500096 STAFF REVIEW COMMENTS NO. 1 Panera Bread — NRA Review 11-00500096 PLANNING 1. The northwest fagade is lacking one architectural relief element. As shown, the dark brick end cap projects so as to be considered a pilaster and satisfies one of the two required elements. Please add a note that signage must be permitted separately. Attached signage may not project above the roofline more than 12". The sign that is show does not compliance with this regulation. Please identify what color is used for the "Silver EIFS" and all colors that will be used on the various awnings. A color sample of each must be submitted so that Staff may determine if there is a match within the College Station Color Palette. '5 As indicated by symbol G1, "storefront" is aluminum. It appears that over 27% of the V southeast fagade is "storefront" which exceeds the 20% maximum of architectural metal allowed on one fagade. ntt6(/t" (k6kA ?/� b aGV, No more than 33% of the southeast fagade can be on the same plane because it faces a public right-of-way. The minimum fagade articulation to satisfy this requirement is 4' in depth. Reviewed by: Lauren A. Hovde, Staff Planner Date: July 1, 2011 1101 Texas Avenue, P.O. Box 9960 College Station, Texas 77842 Phone 979.764.3570 / Fax 979.764.3496 C11 Y ol• Coll C'P:SnToN Hmv ofRm, Adtf(hd"m i" MEMORANDUM August 11, 2011 TO: David Scarmardo via email: david@scarmardofoods.com FROM: Lauren A. Hovde, Staff Planner SUBJECT: Panera Bread - NRA Review Staff reviewed the above -mentioned Non -Residential Architectural plans as requested. The following page is a list of staff review comments detailing items that need to be addressed. Please address the comments and submit the following information by any Monday at 10:00 a.m. for further staff review: One (1) revised set of elevation drawings Color Samples Please note that this application will expire in 90 days from the date of this memo, if the applicant has not provided written response comments and revised documents to the Administrator that seek to address the staff review comments contained herein. If there are comments that you are not addressing with the revised elevations, please attach a letter explaining the details. If you have any questions or need additional information, please call me at 979.764.3570. Attachments: Staff review comments cc: Kling Engineering & Surveying via email: stewart(a.klingeng.com Kevin Wienke via email: KWienke(aDdp3architects.com Case file #11-00500096 STAFF REVIEW COMMENTS NO. 1 Panera Bread — NRA Review 11-00500096 PLANNING 1. The orange doesn't match a color on the approved Color Palette. Is there a different color that can be used? If not, it will be an accent color and can't exceed 10% of each facade. Also, the awning colors need to be added to the color legend for each facade. 2. Painted split -face CMU was added, but this is not actually an allowed material. A different material must be used. I didn't comment on the first round, but there must be percentage included for the materials and colors. Since this is required to be shown, but I didn't make the comment last time, 1 will add it on there with your permission. Reviewed by: Lauren A. Hovde, Staff Planner Date: August 11, 2011