Loading...
HomeMy WebLinkAboutDraiange Letter 2September 25, 2006 Josh Norto~ E.l.T. Graduate Engineer EMAIL: r m en gin ccr @j un o .com City of College Station 1101 Texas Avenue South College Statio~ TX 77842 RE: Drainage Letter for Westerheim Custom Homes 240 Southwest Parkway, College Station, TX Lot SA, Block D -Ashford Square Subdivision, Brazos County RME No. 201-0289 Dear Josh, The proposed addition referenced above consists of a 2,378 square-foot office building, parking, and associated sidewalks. Some parking and drives to support this facility are currently in place. Using the Rational Method and the following parameters, an increase in runoff of approximately 0.42 cfs during the 100-year rainfall event would be experienced. Ration Method: Q =CIA CEXIsT = 0.30 CNEw = 0.95 I= 11.63 in/hr Tc= 10 min. A(affected) = 0.055 acres This runoff is a negligible amount and therefore should not create any adverse impacts to downstream drainage structures and/or facilities. Sincerely, CDl-201-0289-LOl Page-I ofl