HomeMy WebLinkAboutStaff CommentsA CITY OF COLLEGE STNI-ION Horan of7j=Ac M Univerrtty° 1101 Texas Avenue, P.O. Box 9960 College Station, Texas 77842 Phone 979.764.3570 / Fax 979.764.3496 MEMORANDUM October 7, 2009 TO: Rob Crowley; via email robert@crowleyconstruction.com� �[ �D:?-t� FROM: Jennifer Prochazka, AICP Senior Planner SUBJECT: CAMBRIDGE COURT OFFICE BLDG (SP, NRA, DP) Thank you for your submittal of a complete site plan/development permit/non-residential architectural standards application. This project met the October 7, 2009 submittal deadline and will be distributed to staff next week for their review. cc: Highway 40 C&P Investments, LLCM mI>ia� 1email robert@crowle construction. ,i��` ` J Kent Laza; via fax 979-764-7759 V Cat i(�• I-0cl Todd Mcllhaney; via email todd@tmarchitecture.com Case file no. 09-00500210 Case file no. 09-00500211 Case file no. 09-10500060 �1 1101 Texas Avenue, P.O. Box 9960 College Station, Texas 77842 cITY0,-cOI,J.Gl,STATION Phone 979.764.3570 / Fax 979.764.3496 xom-afr ,aew: a„m,w MEMORANDUM October 20, 2009 TO: Rob Crowley; via email robert@crowleyconstructioninc.comt- . iQ. .Ccl FROM: Matthew Hilgemeier, Staff Planner SUBJECT: CAMBRIDGE COURT OFFICE BLDG (SP)- Site Plan Staff reviewed the above -mentioned site plan as requested. The following page is a list of staff review comments detailing items that need to be addressed. Please address the comments and submit the following information for further staff review: Cover memo providing written responses to all of staffs comments (identify the specific page that each comment was addressed on or the reason for not addressing the comment); One (1) revised site plans; One (1) landscaping plan; If there are comments that you are not addressing with the revised site plan, please attach a letter explaining the details. If you have any questions or need additional information, please contact Matthew Hilgemeier at 979.764.3570. Attachments: Staff review comments pc: Highway40 C&P Investments; via email robert@crowleyconstructioninc.comLP 10713cv-t Civil Development Ltd, Kent Laza; via fax 979-764-7759,/u. iA lo.20.OoI Todd Mcllhaney, Architect; via email todd@tmarchitecture.com �IUiJ Case file #09-00500210 STAFF REVIEW COMMENTS NO. 1 Project: CAMBRIDGE COURT OFFICE BLDG (SP) — 09-00500210 PLANNING 1. Please provide a note that Lots 4, 5, and 6 will be considered one building plot. 2. Please include a phase line around the proposed new construction, as done on the landscape plan. 3. Please label the Oxford Court building as existing and the new structure as proposed. 4. Remove General Note # 11 since the zoning is already identified on the Site Specific note and on the lots. 5. General Note # 9 states that topography is shown, but none are shown on the site plan. Please revise. 6. The interior parking island in the front parking lot is shown to be 162 S.F. As it is within 15 feet of the right-of-way, it is required by Section 7.2.C.7 to be at least 360 S.F. (double islands) 7. Please distinguish the existing water, electric, and sewer lines from the proposed lines with different symbols. 8. If this building will be sharing a dumpster with the adjacent structure, please provide a note that the dumpster is shared with Lot 5. 9. Provide a general note on the site plan that states the following: Exterior building and site lighting will meet the standards of Section 7.10 of the Unified Development Ordinance. The light source shall not project below an opaque housing and no fixture shall directly project light horizontally. Fixtures will be mounted in such a manner that the projected cone of light does not cross any property line. 10. Please note that any changes made to the plans, that have not been requested by the City of College Station, must be explained in your next transmittal letter and "bubbled" on your plans. Any additional changes on these plans that the City has not be made of aware of will constitute a completely new review. Reviewed by: Matthew Hilgemeier, Staff Planner Date: 10/19/2009 LANDSCAPING/STREETSCAPING/BUFFER 1. Please let us know if you are planning to use polymeric sand in the landscaping beds around the building. Please note that if this material is used it cannot be used in the parking islands. 2. Please identify the scale of the landscape plan. 3. The Disturbance Limit line looks exactly like the existing sidewalks. Please use a different symbol for the disturbance line. 4. Section 7.5.D.5 requires that when parking is adjacent to a right-of-way that screening is required along 100 percent of the street frontage such as 10 shrubs for every 30 linear feet. The front parking area would require 33 shrubs in addition to the 4 canopy trees. 5. On the landscape plan, there is a call out, "See Detail A". Please label Detail A on the landscape plan. 6. Irrigation Note 3 says that an irrigation plan will be submitted before landscaping begins, however you show an irrigation legend and irrigation details on the plan. Please note approval of this landscape plan does not classify as approval of the irrigation plan. 7. Please identify the caliper size of all trees being used for this project. Reviewed by: Matthew Hilgemeier, Staff Planner Date: 10/19/2009 ENGINEERING 1. Please note the engineering has not finished reviewing the site plan and may have additional comments forthcoming. ELECTRICAL COMMENTS REQUIRING IMMEDIATE ATTENTION 1. Developer may be responsible for locating easements on site to insure that electrical infrastructure is installed within easement boundaries. GENERAL ELECTRICAL COMMENTS 1. Developer installs conduit per CSU specs and design. 2. CSU will provide drawings for electrical installation. 3. Developer will intercept existing conduit at designated transformers or other existing devices and extend as required. 4. If conduit does not exist at designated transformer or other existing devices, developer will furnish and install conduit as shown on CSU electrical layout. 5. Developer provides digital AutoCAD 2000 or later version of plat and / or site plan. Email to: sweido@cstx.gov. 6. Developer provides load data to CSU as soon as it is available to avoid construction delays. Delivery time for transformers not in stock is approximately 40 weeks. 7. Final site plan must show all proposed electrical facilities necessary to provide electrical service, i.e. transformer(s), pull box(es), switchgear(s), meter location and conduit routing as designed by CSU. 8. To discuss any of the above electrical comments please contact Sam Weido at 979.764.6314. Reviewed by: Sam Weido Date: 10-14-09 FIRE 1) The fire lane needs to be in the paved road area next to the building but only one hundred feet (100'). The existing fire lane will only cover part of the new structure. 2) Knox Box required for building Reviewed by: Steve Smith Date: 10/15/09 SANITATION 1. Need to show type of garbage service for business. Reviewed by: Wally Urrutia Date: October 13, 2009 1101 Texas Avenue, P.O. Box 9960 College Station, Texas 77842 Phone 979.764.3570 / Fax 979.764.3496 CITYOPCf L11:4FaTATIOiN MEMORANDUM November 9, 2009 TO: Rob Crowley; via email robert@crowleyconstructioninc.com,/ii�-11-tovcA FROM: Matthew Hilgemeier, Staff Planner SUBJECT: Cambridge Court Office Bldg (Sp)- Site Plan Staff reviewed the above -mentioned site plan as requested. The following page is a list of staff review comments detailing items that need to be addressed. The next submittal will be the third and final review by staff for this round of reviews. If all items have not been addressed on the next submittal, another $668 processing fee will need to be submitted for the subsequent set of three (3) reviews. Please submit the following information for further staff review: Seven (7) complete sets of construction documents for the proposed development with the revised site and landscaping plans attached (one set will be returned to you, please submit additional copies if you want more than one approved set); Four (4) revised site plans; One (1) 11x17 grading and erosion control plan; If there are comments that you are not addressing with the revised site plan, please attach a letter explaining the details. If you have any questions or need additional information, please contact Matthew Hilgemeier at 979.764.3570. Attachments: Staff review comments PC: Highway 40 C&P Investments; via email robert(a)crowlevconstructioninc.comL,-�� Civil Development, Kent Laza; via fax 979-764-7759✓y�{ tFp,Oq Todd Mcllhaney; via email todd@tmarchitecture.com Case file #09-00500210 STAFF REVIEW COMMENTS NO. 1 Project: Cambridge Court Office Bldg (Sp) — 09-00500210 PLANNING Fire lanes in excess of 100 feet shall provide a turnaround for fire trucks. The fire lane in front of the building will need to be shortened to 100 ft. or you will need to include a turnaround area that can accommodate a fire truck. Please note that any changes made to the plans, that have not been requested by the City of College Station, must be explained in your next transmittal letter and "bubbled" on your plans. Any additional changes on these plans that the City has not be made of aware of will constitute a completely new review. Reviewed by: Matthew Hilgemeier, Staff Planner Date: 11/9/09 LANDSCAPING/STREETSCAPING/BUFFER 1. Planning has no additional landscape comments. Reviewed by: Matthew Hilgemeier, Staff Planner Date: 11/9/09 ENGINEERING COMMENTS NO. 2 1. Sh. C1 — For maintenance purposes, we would prefer the waterline to run directly between the main and the meters. Please provide new tap on the 8-inch waterline. 2. Sh. C1 — Will the proposed waterline and meter location conflict with the electrical conduit? 3. Sh. C2 — Please provide stabilized construction exit in accordance with City Standard Details. Reviewed by: Erika Bridges Date: 11/9/09 1101 Texas Avenue, P.O. Box 9960 College Station, Texas 77842 Phone 979.764.3570 / Fax 979.764.3496 CITY of Col I.P.G1, STATION Hone e7 AGM U"vm — MEMORANDUM February 11, 2010 TO: Rob Crowley; via email robert@crowleyconstruction.com FROM: Matthew Hilgemeier, Staff Planner SUBJECT: Cambridge Court Office Bldg Revised Landscape Plan Staff reviewed the above -mentioned site plan as requested. The following page is a list of staff review comments detailing items that need to be addressed. The next submittal will be the third and final review by staff for this round of reviews. If all items have not been addressed on the next submittal, another $668 processing fee will need to be submitted for the subsequent set of three (3) reviews. Please address the comments and submit the following information by any Monday at 10:00 a.m. for further staff review: One (1) landscaping plan If there are comments that you are not addressing with the revised site plan, please attach a letter explaining the details. If you have any questions or need additional information, please call me at 979.764.3570. Attachments: Staff review comments cc: Highway 40 C&P Investments, LLC; via email robert@crowleyconstruction.com °%^7 ! C Civil Development, Ltd; via fax 979-764-7759 Todd Mcllhaney, Architect; via email todd@tmarchitecture.com' I I -,o Case file #09-00500210 STAFF REVIEW COMMENTS NO. 2 Project: Cambridge Court Office Bldg (Sp) - 09-00500210 PLANNING 1. There are no additional planning comments at this time. 2. Please note that any changes made to the plans that have not been requested by the City of College Station must be explained in your next transmittal letter and "bubbled" on your plans. Any additional changes on these plans that the City has not been made aware of will constitute a completely new review. Reviewed by: Matthew Hilgemeier, Staff Planner Date: 2/11/10 LANDSCAPING 1. Phase 1 is missing one required street tree. It appears that it was planted as part of Phase 1, but is now being counted as part of the Phase 2 landscape calculations. Please revise the point total calculations to show that it is part of Phase 1 and identify the plant in the diagram. 2. Landscaping approved to meet Phase 1 landscaping requirements cannot be used to meet Phase 2's landscape point requirements of. Please revise the point totals calculation for each phase. a. Three of the five Bald Cypress trees you identified as new plantings in Phase 2, are trees planted to meet the landscape requirements during Phase 1 construction. Since they are smaller than 4 inches in caliper size, they are not eligible to receive "Existing Trees" points for Phase 2. b. This applies to the five Maiden Grass plants planted for Phase 1 that are now new plantings in Phase 2. 3. FYI — You do not need to change what you are planting. However, the point calculations need revision to show that each phase has the correct amount of streetscaping the correct point totals. The UDO requires that each phase of a multi -phase development must be able to stand-alone and meet the requirements of the ordinance. You can email me or call me to discuss this or authorize me to make the revisions. Reviewed by: Matthew Hilgemeier, Staff Planner Date: 2/11110 Response to STAFF REVIEW COMMENTS Project: CAMBRIDGE COURT OFFICE BUILDING (SP) — 09-00500210 PLANNING 1. Please provide a note that Lots 4, 5 & 6 will be considered one building plot. Added as Site Specific Note # 13: 2. Please include a phase line around the proposed new construction, as done on the landscape plan. The Cambridge Court Phase Line/Disturbance Line has been added to the Site Plan 3. Please label the Oxford Court building as existing and the new structure as proposed. The structures have been labeled as existing and proposed 4. Remove General Note #11 since the zoning is already identified on the Site Specific note and on the lots. The note has been removed from the Site Specific Notes.: 5. General Note #9 states that topography is shown, but none are shown on the site plan. Please revise. The note has been removed from the Site Plan 6. The interior parking island in the front parking lot is shown to be 162 SF. As it is within 15 feet of the right-of-way, it is required by Section 7.2.C.7 to be at least 360 SF (double island). The island is now 366 SF. One parking space was removed and the grading plan was adjusted accordingly. 7. Please distinguish the existing water, electric, and sewer line from the proposed lines with different symbols. The proposed utilities have been made bolder and the existing utilities have been labeled: 8. If this building will be sharing a dumpster with the adjacent structure, please provide a note that the dumpster will be shared with Lot 5. Note has been added as Site Specific Note #12l 9. Provide a general note on the site plan that states the following: Exterior building and site lighting will meet the standards of Section 7.10 of the Unified Development Ordinance. The light source shall not project below an opaque housing and no fixture shall directly project light horizontally. Fixtures will be mounted in such a manner that the projected cone of light does not cross any property line. Note has been added to General Note as Note #9,// 10. Please note that any changes made to the plans, that have not been requested by the City of College Station, must be explained in your next transmittal letter and "bubbled" on your plans. Any additional changes on these plans that the City has not been made aware of will constitute a completely new review. Noted. EIy INEERING COMMENTS NO. 1 U1. /' Sh. C1 — Please move water meters so that they are still within a PUE but not within a paved J area. The water meters have been moved out of the pavement. P/ Sh. C1 — Please list the minimum required fire flow in gallons per minutes for each hydrant on the site plan. The minimum required fire flow of 1,760 GPM was listed on the existing fire hydrant. Sh. C2 — Will excess cut be utilized on site or stockpiled on another lot? The excess cut will be removed from the site. Sh. C2 — Since there will be grading on Lot 6, additional silt fence should be added along the north side of that lot. Silt fence has been added. ,e✓Sh. C2 — Please provide a note regarding revegetating disturbed and erosion control requirements from City Std. Detail Sheet SWPP1. The notes from the City Std. Detail Sheet SWPP1 have been added to the Grading Plan. Sh. C2 — Where's the construction exit going to be located? The construction exit has been added to the Grading Plan. ;U//Water Letter— Please provide referenced water report. A copy of the Castle Rock Phase 1B & 1C water report has been included with this submittal. Water Letter— Please provide actual fire hydrant flow data from the existing hydrant along north side of Lot 6. unitae Fire Flow Test Data has been included with this submittal. ry Sewer Letter —According to the plans, this development is on Lots 5 & 6 with an area of 0.89 Ac. Please revise letter. T e letter has been revised and resubmitted. 1 Please include applicable City Standard Details (Storm D1-00, SWPP1-00 & SWPP1-02) The City Standard Details have been attached to the construction drawings for this submittal. 11: Please submit NOI, as this is part of a larger development exceeding 5Ac. The NO[ will be submitted by the contractor. 1. prainage Report — We cannot locate the referenced Castle Rock Ph. 1 B & 1 C drainage report. V Please provide supplemental report. copy of the Castle Rock Ph. 1 B & 1 C has been attached with this submittal. f Drainage Report — The Castle Rock Phase 1 B & 1 C drainage report based on certain assumptions about the future development to verify that the outfall and storm sewer you are proposing tying into are sized appropriately. A StormCad analysis has been provided in the drainage report. 1/2Drainage Report — PA should reference the development occurring on Lots 5 & 6 as indicated on the plans. Page 1 has been corrected. 5 Drainage Report — Please submit the February 2009 version of Appendix D. /The February 2009 version of Appendix D has been used for this submittal. 1€l Drainage Report— (App.D, P. 5) NOI required and acknowledged on Page 1 of Drainage Report. Page 5 has been revised. 7 Drainage Report — (App. D, P. 6) "Building on two or more platted lots of undeveloped land" should be selected since development is on Lots 5 & 6. Page 6 has been corrected. -0/crainage Report— (App. D, P. 11) The "Shared Facility" information is not complete. Please provide all information requested. The Shared Facility information has been revised. The Crowley Detention Pond was designed in 1999 by LJA Engineers for Castle Gate and Castle Rock subdivisions and other surrounding properties. Please refer to the LJA study for more information. 1bainage Report — (App. D, P. 14) The "Watercourse (or system), velocity, and angle' information is not complete. Please provide all information requested. The velocity and angle information has been provided on P. 14. 2Q /[�/rainage Report — (App. D, P. 23) Where is the "Design Drainage Area" map? Should the V Design Drainage Area be 0.89 acres? The drainage area map has been provided with this submittal. LAN DSCAPING/STREETSCAP ING/BU FFER 1. Please let us know if you are planning to use any polymeric sand in the landscaping beds around the building. Please note that if this material is used, it canngt be used in the parking islands. At this time, there are no plans to use polymeric sand. 2. Please identify the scale of the landscape plan. A scale has been added to the landscape plan 3. The disturbance limit line looks exactly like the existing sidewalks. Please use a different symbol for the disturbance line. The linetype of the disturbance line has been changed 4. Section 7.5.D.5 requires that when parking is adjacent to a right-of-way that screening is required along 100 percent of the street frontage such as 10 shrubs for every 30 linear feet. The front parking area would require 33 shrubs in addition to the 4 canopy trees. Shrubs have been added to screen the parking area. 5. One the landscaping plan, there is a call out, "See Detail A". Please label detail A on the landscape plan. Detail A has been labeled—/ 6. Irrigation Note 3 says that an irrigation plan will be submitted before landscaping begins, however, you show an irrigation legend and irrigation details on the plan. Please not approval of this landscape plan does not classify as approval of the irrigation plan. The note has been changed. The irrigation plan is shown on the landscape plan, however, it is understood that the approval of the landscape plan does not classify as approval of the irrigation plan. 7. Please identify the caliper size of all trees being used for this project. Required caliper size of landscaping has been added to the legend ELECTRICAL COMMENTS REQUIRING IMMEDIATE ATTENTION 1. Developer may be responsible for locating easements on site to insure that electrical infrastructure is installed within easement boundaries. Noted. GENERAL ELECTRICAL COMMENTS 1. Developer installs conduit per CSU specs and design. 2. CSU will provide drawings for electrical installation. 3. Developer will intercept existing conduit at designated transformers or other existing devices and extend as required. 4. If conduit does not exist at designated transformer or other existing devices, developer will furnish and install conduit as shown on CSU layout. 5. Developer provides digital AutoCAD 2000 or later version of plat and/or site plan. Email to sweido(,Scstx.00v 6. Developer provides load data to CSU as soon as it is available to avoid construction delays. Delivery time for transformers not in stock is approximately 40 weeks. 7. Final site plan must show all proposed electrical facilities necessary to provide electrical service, i.e. transformer(s), pull box(es), switchgear(s), meter location and conduit routing as designed by CSU. 8. To discuss any of the above electrical comments please contact Sam Weido at 979.764.6314 Noted. FIRE 21. The fire lane needs to be in the paved road area next to the building but only one hundred feet (100'). The existing fire lane will only cover part of the new structure. The fire lane has been extended into the parking lot. 22. Knox Box required for building. Noted. SANITATION 1. Need to show type of garbage service for building. The business will share a dumpster w/ Oxford Court Office Building on Lot 4. A note has been added to the Site Plan. Responseto STAFF REVIEW COMMENTS Project: CAMBRIDGE COURT OFFICE BUILDING (SP) — 09-00500210 PLANNING 1. Fire lanes in excess of 100 feet shall provide a turnaround for fire trucks. The fire lane in front of the building will need to be shortened to 100 ft. or you will need to include a turnaround area hat can accommodate a fire truck. The fire land has been shortened to 100 ft. 2. Please note that any changes made to the plans that have not been requested by the City of College Station must be explained in your next transmittal letter and "bubbled" on your plans. Any additional changes on these plans that the City has not been made aware of will constitute a completely new review. A portion of sidewalk and a handicap ramp has been added from the existing sidewalk to the Emergency Access Road to meet ADA requirements. The addition has been bubbled on the plans. ENGINEERING COMMENTS NO. 1 1. Sh. C1 — For maintenance purposes, we would prefer the waterline to run directly between the main and the meters. NIA 2. Sh. C1 — Will the proposed waterline and meter location conflict with the electrical conduit? The electrical conduit should be deep enough that the water meters will not interfere with it. If there is a problem during construction, it can be adjusted in the field. 3. Sh. C2 — Please provide stabilized construction exit in accordance with City Standard Details. A note has been added to refer to the detail on the SWPP1 detail sheet.