HomeMy WebLinkAboutStaff Report(*t/q"
CITY OF COLLEGE STATION
PRELIMINARY PLAT
FOR
F.S. KAPCHINSKI (PP)
08-00500329
SCALE: 11 lots on 2.956 acres
LOCATION:
1600, 1600A, 1604, 1624, and 1626 Park Place
ZONING:
R-1, Single Family Residential (2.05 acres)
R-6, High Density Multifamily (.91 acres)
APPLICANT:
Ali Jaffer, FI Partner, Ltd.
Ali Jaffer, IMA Enterprises
Thomas Sitton
PROJECT MANAGER:
Lindsay Kramer, AICP, Senior Planner
Ikramer@cstx.gov
RECOMMENDATION: Denial for the variances and preliminary plat.
Planning &Zoning Meeting Page 1 of 6
January 15, 2009
Planning & Zoning Meeting Page 2 of 6
January 15, 2009
J
W
a
G
A
w
G'
Z
w
a
O
J
W
LU
W
Planning & Zoning Meeting Page 3 of 6
January 15, 2009
DEVELOPMENT HISTORY
Annexation: 1956
Zoning: R-6 and R-1 since annexation
Final Plat: Original final plat for F.S. Kapchinski was filed prior to 1939, but
the year is unknown
Site Development: Existing single-family structures located on lots 18R-1, 28R-1,
24R-1, and 24R-2
COMMENTS
Water: The subject tract is located adjacent to an eight -inch water main which
runs parallel and adjacent to Park Place. Six-inch and three-inch water
mains are proposed to be extended with the development of this tract to
serve the additional lots.
Sewer: The subject tract is located adjacent to an 8 inch sanitary sewer main
which runs along the western property line. A 6 inch sanitary sewer main
is proposed to be extended with the development of this tract to serve the
additional lots.
Streets: The subject tract is located adjacent and will take access to Park Place
(Residential Street). A residential cul-de-sac is proposed with this
development in order to provide access to the proposed lots.
Off -site Easements: None known at this time
Drainage: The subject tract is located in the Wolf Pen Creek Drainage Basin. The
subdivision's proposed detention facility is located near the southwest
property corner. The developing/final platting of the tract will be required
to meet the minimum standards of the City's Drainage Design Guidelines.
Flood Plain: None
Oversize Request: None
Parkland Dedication
Fees: Parkland dedication in the amount of $1,800 is required for 2 additional
single-family lots and has been approved administratively. Fee in lieu of
land dedication for the multi -family lots will be required at the time of
building permit based on the number of units being built. Multi -family
projects with less than 375 units may be approved administratively. No
action is required by the Planning and Zoning Commission.
Impact Fees: None
REVIEW CRITERIA
Compliance with Comprehensive Plan and Unified Development Ordinance: The
subject plat is in compliance with the Comprehensive Plan for High Density Single -Family
and with the zoning requirements of the Unified Development Ordinance.
Planning & Zoning Meeting Page 4 of 6
January 15, 2009
Compliance with Subdivision Regulations: The proposed plat is further subdividing 9
lots into 11 lots. Of the new lots, 8 of those lots are single-family lots zoned R-1, and the
remainder are zoned for multi -family (R-6). The single-family lots were originally platted prior
to 1970 and as such are subject to the requirements of Section 18 of the City's Subdivision
Regulations. The regulations require new building plots must have a minimum size of 8,500
square feet in lot area and the minimum lot width must meet or exceed the average lot width
of the existing building plots on the lot.
The applicant is requesting a variance to these sections for the following lots:
17R1
Lot Width
62.24'
Variance
Requested
None
Lot Size
6,697 sf
Variance
Requested
1,803 sf
17R2
62.42'
None
6,621 sf
1,879 sf
18R1
52.00'
8.26'
5,980 sf
2,520 sf
18R2
52.10'
8.16'
6,107 sf
2,393 sf
28R
49.24
11.02'
11,383sf
None
Lots 30R, 31 R, and 32R do not require any variances because they are zoned for multi-
family and are not subject to Section 18 requirements.
In accordance with the Subdivision Regulations, when considering the variance, the
Planning and Zoning Commission should make the following findings to approve the
variances (staff findings are in italics below):
1. That there are special circumstances or conditions affecting the land involved such that
strict application of the provisions of this chapter will deprive the applicant of the
reasonable use of his land;
Several of the lots in the replat are currently landlocked, and a variance to lot size and
width for Lot 17 would be required in order to provide street access to those lots,
however the street projection could be accommodated with a Lot 17R that would only
require a variance 0.02-feet in width, rather than a 17R1 and a 17R2 that both need
width and lot size variances. No special condition or circumstance exists for the further
subdivision of Lot 18.
2. That the variances are necessary for the preservation and enjoyment of a substantial
property right of the applicant;
As stated previously, some variance is required to provide access to lots 29, 30, 31, and
32, which are landlocked by previous plats.
3. That the granting of the variances will not be detrimental to the public health, safety, or
welfare, or injurious to other property in the area, or to the City in administering this
chapter; and
The properties take access to Park Place which is a local road that is often used for non -
local traffic between Texas Avenue and Anderson. The current width and configuration
Planning & Zoning Meeting Page 5 of 6
January 15, 2009
of the road do not meet current standards, and Staff believes that providing unwarranted
variances that increase the number of lots taking access to the road may have a
negative impact on the pedestrian and vehicular safety of the residents in this area.
4. That the granting of the variances will not have the effect of preventing the orderly
subdivision of other land in the area in accordance with the provisions of this chapter.
The subject properties are surrounded by property that is already platted and developed.
Granting of the variances would not hinder any future subdivisions of property.
STAFF RECOMMENDATION
Staff recommends denial of the variances and thus the preliminary plat.
SUPPORTING MATERIALS
1. Application
2. Variance Request
3. Copy of Preliminary Plat (provided in packet)
Planning & Zoning Meeting Page 6 of 6
January 15, 2009
(*t/q"
CITY OF COLLEGE STATION
PRELIMINARY PLAT
FOR
F.S. KAPCHINSKI (PP)
08-00500329
SCALE: 11 lots on 2.956 acres
LOCATION:
1600, 1600A, 1604, 1624, and 1626 Park Place
ZONING:
R-1, Single Family Residential (2.05 acres)
R-6, High Density Multifamily (.91 acres)
APPLICANT:
Ali Jaffer, FI Partner, Ltd.
Ali Jaffer, IMA Enterprises
Thomas Sitton
PROJECT MANAGER:
Lindsay Kramer, AICP, Senior Planner
Ikramer@cstx.gov
RECOMMENDATION: Denial for the variances and preliminary plat.
Planning &Zoning Meeting Pagel of6
January 15, 2009
Planning & Zoning Meeting Page 2 of 6
January 15, 2009
J
W
a
Planning & Zoning Meeting Page 3 of 6
January 15, 2009
G
A
w
G'
Z
w
a
O
J
W
LU
W
DEVELOPMENT HISTORY
Annexation: 1956
Zoning: R-6 and R-1 since annexation
Final Plat: Original final plat for F.S. Kapchinski was filed prior to 1939, but
the year is unknown
Site Development: Existing single-family structures located on lots 18R-1, 28R-1,
24R-1, and 24R-2
COMMENTS
Water: The subject tract is located adjacent to an eight -inch water main which
runs parallel and adjacent to Park Place. Six-inch and three-inch water
mains are proposed to be extended with the development of this tract to
serve the additional lots.
Sewer: The subject tract is located adjacent to an 8 inch sanitary sewer main
which runs along the western property line. A 6 inch sanitary sewer main
is proposed to be extended with the development of this tract to serve the
additional lots.
Streets: The subject tract is located adjacent and will take access to Park Place
(Residential Street). A residential cul-de-sac is proposed with this
development in order to provide access to the proposed lots.
Off -site Easements: None known at this time
Drainage: The subject tract is located in the Wolf Pen Creek Drainage Basin. The
subdivision's proposed detention facility is located near the southwest
property corner. The developing/final platting of the tract will be required
to meet the minimum standards of the City's Drainage Design Guidelines.
Flood Plain: None
Oversize Request: None
Parkland Dedication
Fees: Parkland dedication in the amount of $1,800 is required for 2 additional
single-family lots and has been approved administratively. Fee in lieu of
land dedication for the multi -family lots will be required at the time of
building permit based on the number of units being built. Multi -family
projects with less than 375 units may be approved administratively. No
action is required by the Planning and Zoning Commission.
Impact Fees: None
REVIEW CRITERIA
Compliance with Comprehensive Plan and Unified Development Ordinance: The
subject plat is in compliance with the Comprehensive Plan for High Density Single -Family
and with the zoning requirements of the Unified Development Ordinance.
Planning & Zoning Meeting Page 4 of 6
January 15, 2009
Compliance with Subdivision Regulations: The proposed plat is further subdividing 9
lots into 11 lots. Of the new lots, 8 of those lots are single-family lots zoned R-1, and the
remainder are zoned for multi -family (R-6). The single-family lots were originally platted prior
to 1970 and as such are subject to the requirements of Section 18 of the City's Subdivision
Regulations. The regulations require new building plots must have a minimum size of 8,500
square feet in lot area and the minimum lot width must meet or exceed the average lot width
of the existing building plots on the lot.
The applicant is requesting a variance to these sections for the following lots:
17R1
Lot Width
62.24'
Variance
Requested
None
Lot Size
6,697 sf
Variance
Requested
1,803 sf
17R2
62.42'
None
6,621 sf
1,879 sf
18R1
52.00'
8.26'
5,980 sf
2,520 sf
18R2
52.10'
8.16'
6,107 sf
2,393 sf
28R
49.24
11.02'
11,383sf
None
Lots 30R, 31 R, and 32R do not require any variances because they are zoned for multi-
family and are not subject to Section 18 requirements.
In accordance with the Subdivision Regulations, when considering the variance, the
Planning and Zoning Commission should make the following findings to approve the
variances (staff findings are in italics below):
1. That there are special circumstances or conditions affecting the land involved such that
strict application of the provisions of this chapter will deprive the applicant of the
reasonable use of his land;
Several of the lots in the replat are currently landlocked, and a variance to lot size and
width for Lot 17 would be required in order to provide street access to those lots,
however the street projection could be accommodated with a Lot 17R that would only
require a variance 0.02-feet in width, rather than a 17R1 and a 17R2 that both need
width and lot size variances. No special condition or circumstance exists for the further
subdivision of Lot 18.
2. That the variances are necessary for the preservation and enjoyment of a substantial
property right of the applicant;
As stated previously, some variance is required to provide access to lots 29, 30, 31, and
32, which are landlocked by previous plats.
3. That the granting of the variances will not be detrimental to the public health, safety, or
welfare, or injurious to other property in the area, or to the City in administering this
chapter; and
The properties take access to Park Place which is a local road that is often used for non -
local traffic between Texas Avenue and Anderson. The current width and configuration
Planning & Zoning Meeting Page 5 of 6
January 15, 2009
of the road do not meet current standards, and Staff believes that providing unwarranted
variances that increase the number of lots taking access to the road may have a
negative impact on the pedestrian and vehicular safety of the residents in this area.
4. That the granting of the variances will not have the effect of preventing the orderly
subdivision of other land in the area in accordance with the provisions of this chapter.
The subject properties are surrounded by property that is already platted and developed.
Granting of the variances would not hinder any future subdivisions of property.
STAFF RECOMMENDATION
Staff recommends denial of the variances and thus the preliminary plat.
SUPPORTING MATERIALS
1. Application
2. Variance Request
3. Copy of Preliminary Plat (provided in packet)
Planning & Zoning Meeting Page 6 of 6
January 15, 2009