HomeMy WebLinkAboutWater System ReportWater System Report for Spring Creek Townhomes, Phases 2 & 3 College Station, Texas January 2008 Prepared By: Civil Development, Ltd. 2033 Harvey Mitchell Parkway South College Station, Texas 77840 (979) 764-7743 Spring Creek Townhomes, Phases 2 & 3 Water System Report General Information Location: Spring Creek Townhomes, Phases 2 & 3 are located in southern College Station near the intersection of Decatur Drive and Arrington Road. 111ey are immediately adjacent to Spring Creek Townhomes, Phase 1 and Spring Creek Gardens, Phase 1. The subdivision has 71 lots along Heath Drive and Dawn Lynn Drive. Land Use: Single Family Residential Design Criteria Primary Water Supply: Existing 12" line on Decatur Drive Domestic Demand: Avg. Pop Density: 2.67 people per lot Average Flow: Peaking Factor: 100 gpd/cap or 267 gpd per lot = 0.18 gpm per lot 4 Peak Flow: Design Flow: Fire Demand: 0.74 gpm per lot 1.50 gpm per lot Fire Flow: Pipe: 1000 gpm at most hydraulically remote point PVC DR-14 C909 Roughness Coeff: 150 (Hazen Williams) Hydraulic Software: Haestad Methods WaterCAD v.6.0 Existing City System Pressure Tests Flow Hydrant#: R-048 (Decatur@ Alexandria) Flowrate: 1500 gpm Static Hydrant#: R-051 (Spring Garden) Static Pressure: 104 psi (240 ft water) Residual Pressure: 102 psi (236 ft water) Applicable Exhibits: Exhibit A -College Station Utilities Flow Test Report Water System Summary Criteria Required As Designed Min. Pressure -fire (psi) 20 102 Max. Velo city (fps) 12 7.01 Max. Length of 6 "pipe (ft) 1500 1059 (connected to ~ 8 "011 both Max Length of 6 "pipe (ft) 800 NA (not connected on both ends Max. Length of 3 "pipe (ft) 500 MA Applicable Exhibits: Exhibit B -Water System Schematic Exhibit C -Summary of Results -Fire Flow Water System Conclusion Location FH-2 W-1-1 The proposed water system for Spring Creek Townhomes, Phases 2 & 3 meets or exceeds all of the design criteria fo r the City of Coll ege Station. JJ /ll!/ZUU4 Jt>:ZZ l'l\A l11 t1 tt>4 .>4 J.l II -1( College Station Utilities ~ Reliable, Affordable, Community Owm.·d 1601 GRAHAM ROAD COLLEGE STATION TEXAS 77845 Date: 18 NOVEMBER 2004 Number pages including cover sheet -1 Fax to: 764-7759 Attention: JOE SCHULTZ Company: TEXCON From: Butch Willis Water Wastewater Division Phone: 979-764-3435 Fax: 979-764-3452 FLOW TEST REPORT Nozzle size: 2.5 inch Location: ALEXANDRIA AT DECATUR Flow hydrant number: R-048 Pi tot reading: 80 (GPM): 1500 Static hydrant number: R-046 Static PSI: 104 1 Residual PSI: 102 1 Exhibit A ' / // / / / // / / / / ////~ ', / / ' ' ii // I; j ii i ;,: .:; 1! : / J / / / // / " / / / / " ,,· / / / / I I / I I I / I ,., ,., / ; /,,. I/ ,.,/ I :' I I I / 1 1 I , I : i ! ; i/ / // i i : i I I I I I / I I , , / // ! I ! ! I I I :' f ! i I / // : // , ; EXHIBIT B Wr 1-j3 SPRING CREEK TOWNHOMES PHASES 2 & 3 WATER SYSTEM SCHEMATIC -I __ _I 2 .. t--·---Q) > ·c 0 £ -+-J 0 Q) :r: SCT2-1 * CIVll.lkva.OPMENI; Lt,,_* Cf'l,[~(AING,Nl:r ........ o~··.rr• 2033 Har, .. y t·.lttl•ell Pr11< 1 Seiulll Coll.•9·· $1.11,,,.1 1. · '" 7i~tt0 P O Bo • 11c.2~l I.nu •. ., .. ':ii '''''" 1._., •!> i'7.~.!.:' ,.:;q, ifil.. 7 i .11 r .1, I .. '~'.'! "I"~: :'i'•I TESTED FH -----1"'1 SCT3-1 ~ -1 "" I L ['' I~ I ~-I "" SCALE: NOT TO SCALE Label W-1 -1 W-1-2 W-1-3 W-2-1 W-2-2 W-2-3 Exhibit C Spring Creek Townhomes, Phases 2 & 3 Water System Analysis Pipe Summary -Fire Flow Conditions --------~-Length Diameter Material Hazen-Discharge Velocity (ft) (in) Williams C (gpm-) --(ft/s) 337 8 PVC 150 -1,097.50 7.01 354 6 PVC 150 -216.90 2.46 706 6 PVC 150 194.40 2.21 309 8 PVC 150 -856.60 5.47 235 8 PVC 150 173.40 1.11 135 8 PVC 150 -6.00 0.04 Maximum Velocity = 7.01 Junction Summary -Fire Flow Conditions Label Elevation Demand Hydraulic Pressure Grade (ft) (gpm) (ft) (psi) FH 1 275 22.5 517.65 104.98 FH 2 280.5 1,030.0 515.59 101 .71 SCT2-1 279.5 15.0 515.71 102.20 SCT2-2 279 6.0 515.71 102.41 SCT3-1 286 9.0 524.45 103.16 SCT3-2 281 24 .0 518.84 102.90 Lowest Pressure = 101.71