Loading...
HomeMy WebLinkAboutDrawingsSITE NAME: S r1% ITE NUMBER: STRUCTURE TYPE: FA CODE: LEVEL 5 CONSULTING ENGINEERS DEXTER HX3572 _w 1"ARKING GARAGE 10574932 2013 NSB T. 3063630733 SHEET INDEX ............ .......... ... ........ :'-'X ....... ......... ............ ........... ........ ... . ........... . ..... ... .. .. ............. :%...:'1:'.. ............. .......... ....... . . ..... .......... . . . ......... PROJECT INFORMATION DRIVING DIRECTIONS GENERAL ARRANGEMENT PLANS SITE NAME: DEXTER FROM GEORGE BUSH INTERCONTINENTAL AIRPORT: SITE NUMBER: HX3572 HEAD WEST ON N TERMINAL RD. SLIGHT RIGHT ONTO COVER SHEET 911 ADDRESS: 301 GEORGE BUSH DRIVE COLLEGE STATION, TX 77840 JOHN F KENNEDY BLVD. CONTINUE STRAIGHT TO STAY ON JOHN F KENNEDY BLVD. TURN RIGHT ONTO TEXAS 8 BELTWAY FRONTAGE RD. TAKE THE TEXAS 8 N.SF LATITUDE: 30.603222* BELTWAY W RAMP ON THE LEFT TO 1-45. MERGE LONGITUDE: -96.340134* ONTO TX -8 BELTWAY W. CONTINUE ONTO SAM HOUSTON TOLLWAY W TOLL ROAD. TAKE THE EXIT GROUND ELEVATION: ±338' AMSL ONTO US -290 W TOWARD AUSTIN. EXIT ONTO TX -6 GENERAL NOTES JURISDICTION: CITY OF COLLEGE STATION STRUCTURE TYPE: PARKING GARAGE N TOWARD COLLEGE STATION/BRYAN. TAKE THE TEXAS 6 BUSINESS EXIT ON THE LEFT TOWARD COLLEGE STATION. MERGE ONTO S TEXAS AVE.TURN LEFT ONTO GEORGE BUSH DR. SITE IS ON THE LEFT ........... ............. ...... ..... ... .......... .. ........... X ...... . . .............. ...................... ......... .................... . . ......... "'fl.... SCOPE OF WORK CONTACTS ... . ...... ................ .......... ............... .......... . 1._::<:::>::::<:::>:><:.....::>::::<.......... THE WIRELESS COMMUNICATIONS FACILITY IS NOT INTENDED FOR HUMAN OCCUPANCY APPLICANT: NOTES . ........ .... .... ..... .......... .......... ............ ............ . .................. AT&T MOBILITY 1. INSTALL (6) PANEL ANTENNAS ON SIDE OF EXISTNG PARKING 1801 VALLEY VIEW LANE GARAGE FARMERS BRANCH, TX 75234 . . . ..... 2. INSTALL (12) RRU, (9) UMTS RRUS-11 AND (3) LTE RRUS_1_1_,_ SV1 BOUNDARY SURVEY BY OTHERS) ON NEW H -FRAME .............. . 30, 3. INSTALL (1) RAYCAP FC12 FIBER DISTRIBUTION BOX AND (6) RAYCAP DC SURGE SUPPRESSION UNITS PROPERTY OWNER: .... 4. INSTALL (1) 48V POWER CABINET & TRANSFORMER ON CALLAWAY STUDENT HOUSING 4' -01'X6$ -0j) EQUIPMENT PLATFORM 5. INSTALL (2) NEW PURCELL CABINETS AND PROVISIONS FOR (1) 301 GEORGE BUSH DR. W COLLEGE STATION, TX 77840 FUTURE 0 A0.0 6. INSTALL DISCONNECT SWITCHES, PPC & CIENA ON NEW ... ........ . ...... .... H -FRAME 7. INSTALL (2) DC POWER CABLES (3/4") EXISTING EQUIPMENT SITE PLAN 8. INSTALL (1) FIBER TRUNK (3/8") 9. INSTALL (3) RET CABLES (5/16") CONSULTANT: APPLICABLE CODES & STANDARDS GOODMAN NETWORKS A1.1 PROPOSED COMPOUND PLAN 14701 N. HWY 281, SUITE 220 SAN ANTONIO, TX 78232 - INTERNATIONAL BUILDING CODE, 2012 EDITION AS ADOPTED BY LOCAL CONTACT: MARY JO STICKEL JURISDICTION. PHONE: 214-632-1008 ENLARGED EQUIPMENT PLAN - NATIONAL ELECTRICAL CODE, 2011 EDITION AS ADOPTED BY LOCAL E-MAIL: MJStickel@goodmannetworks.com JURISDICTION. TOWER ELEVATION - INTERNATIONAL MECHANICAL CODE, 2012 EDITION AS ADOPTED BY LOCAL A2.1 JURISDICTION. - INTERNATIONAL ENERGY CONSERVATION CODE, 2012 EDITION AS CH1TECT/FN(;1NFFR- LEVEL 5 CONSULTING ENGINEERS DEXTER HX3572 _w 1"ARKING GARAGE 10574932 0 lok to] N a V 16 1 111111671W 10 1m CONTRACTOR DATE THE ABOVE PARTIES HEREBY APPROVE AND ACCEPT THESE DOCUMENTS AND AUTHORIZE CONTRACTOR TO PROCEED WITH THE CONSTRUCTION DESCRIBED HEREIN. ALL DOCUMENTS ARE SUBJECT TO REVIEW BY THE LOCAL BUILDING DEPARTMENT AND MAY IMPOSE CHANGES OR MODIFICATIONS. SITE ACCESS PROCEDURES NOTE: DRAWING SCALES ARE L FOR 22"X34" SHEETS UNLESS OTHERWISE NOTED. PREPARED FOR: a. mod 1001'....: w w 11 mom at&t AT&T MOBILITY , 1801 VALLEY VIEW LANE FARMERS BRANCH, TX 75234 CONSULTANT: GoodmanNetworks 6400 INTERNATIONAL PARKWAY SUITE 1000 PLANO, TX 75093 Tel: (972) 406.9692 SITE NAME: DEXTER SITE NUMBER: HX3572 SITE ADDRESS: 301 GEORGE BUSH DRIVE COLLEGE STATION, TX 77840 BRAZOS COUNTY 11/15/2013 OF TF 11 sa GG '4 A- A-1-4 ............... ANTHONY L HU�T��./ 0 ....................... -o0. 1. 102126 00 ji ow o'p S T 0 N A L, L -1:10buh- o LEVEL 5 \��\\ CONSULTING ENGINEERS, INC. 19315 FM 2252, STE. 301 PH: (210) 542-5911 GARDEN RIDGE, TX,78266 F-13646 DRAWN BY: RS APPROVED BY: TH DATE DRAWN: 10/16/13 REVISION NO DESCRIPTION BY DATE 0 ISSUED FOR CONSTRUCTION RS 10/22/13 1 REVISED PER RFDS TH 10/31/13 2 REVISED PER COMMENTS WS 11/14/13 SHEET TITLE: COVER SHEET SHEET NUMBER: T1 mO VICINITY MAP SHEET INDEX ............ .......... ... ........ :'-'X ....... ......... ............ ........... ........ ... . ........... . ..... ... .. .. ............. :%...:'1:'.. ............. .......... ....... . . ..... .......... . . . ......... IF"' SITE GENERAL ARRANGEMENT PLANS . .......... ......... ..... . .... :::.....::<........... X.: .................... ... .. ................ . . ....... .. .. ...... . . ....... ..... .. .. ..... ......... .................... ..... ...... ... ....... �X'....................... ::::::. : 1, ............. . T1.0 COVER SHEET .......... .... ......... ........... . .............. N.SF . . ... ..... ..... ... .............. :1.,...."...'...... - . .. ..... . ... . .... . .......... N 1.0 GENERAL NOTES . ...... ......... ­.­­ ........... ............. ...... ..... ... .......... .. ........... X ...... . . .............. ...................... ......... .................... . . ......... "'fl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i<:::::: .......... ........... . . ....... ....... . . ............... . ..... . .. ....... ............ ... .......... . :,:,: ............ ::' ::::: ..... ::...: . ... ... . .... ... . ... . ...... . .. . . .............. . 30, ARCHITECTURAL CIVIL PLANS . ................ .. : ... ......... .............. .. ........ .... 0 A0.0 OVERALL AREA PLAN ... ........ . ...... .... A1.0 EXISTING EQUIPMENT SITE PLAN Ae A1.1 PROPOSED COMPOUND PLAN A1.2 ENLARGED EQUIPMENT PLAN A2.0 TOWER ELEVATION A2.1 ANTENNA PLAN AND DETAILS Al .10 . .. .. A2.2 ANTENNA CONFIGURATION .................. A3.0 PLUMBING DIAGRAM APPROVALS A4.0 EQUIPMENT DETAILS A4.1 EQUIPMENT DETAILS A4.2 FENCE DETAILS A5.0 SITE SIGNAGE DETAILS AT&T REAL ESTATE DATE A5.1 SITE SIGNAGE NOTES AT&T RF ENGINEERING DATE ELECTRICAL PLANS E1.0 ELECTRICAL AND TELCO PLAN AT&T CONSTRUCTION MANAGER DATE E2.0 ANTENNA GROUNDING PLAN AND ONE -LINE DIAGRAM E2.1 COMPOUND GROUNDING PLAN AT&T OPERATIONS DATE E3.0 ELECTRICAL DETAILS E4.0 GROUNDING DETAILS GOODMAN CONSTRUCTION MANAGER DATE E4.1 ELECTRICAL SPECIFICATIONS 0 lok to] N a V 16 1 111111671W 10 1m CONTRACTOR DATE THE ABOVE PARTIES HEREBY APPROVE AND ACCEPT THESE DOCUMENTS AND AUTHORIZE CONTRACTOR TO PROCEED WITH THE CONSTRUCTION DESCRIBED HEREIN. ALL DOCUMENTS ARE SUBJECT TO REVIEW BY THE LOCAL BUILDING DEPARTMENT AND MAY IMPOSE CHANGES OR MODIFICATIONS. SITE ACCESS PROCEDURES NOTE: DRAWING SCALES ARE L FOR 22"X34" SHEETS UNLESS OTHERWISE NOTED. PREPARED FOR: a. mod 1001'....: w w 11 mom at&t AT&T MOBILITY , 1801 VALLEY VIEW LANE FARMERS BRANCH, TX 75234 CONSULTANT: GoodmanNetworks 6400 INTERNATIONAL PARKWAY SUITE 1000 PLANO, TX 75093 Tel: (972) 406.9692 SITE NAME: DEXTER SITE NUMBER: HX3572 SITE ADDRESS: 301 GEORGE BUSH DRIVE COLLEGE STATION, TX 77840 BRAZOS COUNTY 11/15/2013 OF TF 11 sa GG '4 A- A-1-4 ............... ANTHONY L HU�T��./ 0 ....................... -o0. 1. 102126 00 ji ow o'p S T 0 N A L, L -1:10buh- o LEVEL 5 \��\\ CONSULTING ENGINEERS, INC. 19315 FM 2252, STE. 301 PH: (210) 542-5911 GARDEN RIDGE, TX,78266 F-13646 DRAWN BY: RS APPROVED BY: TH DATE DRAWN: 10/16/13 REVISION NO DESCRIPTION BY DATE 0 ISSUED FOR CONSTRUCTION RS 10/22/13 1 REVISED PER RFDS TH 10/31/13 2 REVISED PER COMMENTS WS 11/14/13 SHEET TITLE: COVER SHEET SHEET NUMBER: T1 mO LINE AND SYMBOL_ LEGEND X CHAIN—LINK FENCE BOUNDARY WOOD FENCE BOUNDARY UNDERGROUND ELECTRICAL CONDUIT AND FEEDER UNDERGROUND TELEPHONE COMPANY -CONDUIT TO TELCO DEMARK POINT H HYBRID CABLE C I MAIN COAX FEEDER T I TELCO WIRING E POWER WIRING G GROUND WIRING F FIBER CABLE ® • ♦ CONNECTION (CADWELD OR EXOTHERMIC WELD TO STRUCTURE OR DEVICE) GROUNDING BAR GROUND POINT 00 METER 0 GENERAL REQUIREMENTS 1.1 PURPOSE AND INTENT A. THE DRAWINGS AND SPECIFICATIONS ARE INTENDED TO BE FULLY EXPLANATORY AND C. ALL WASTE MATERIAL SHALL BE PROPERLY DISPOSED OF OFF—SITE OR AS DIRECTED SUPPLEMENTARY. HOWEVER, SHOULD ANYTHING BE SHOWN, INDICATED OR SPECIFIED ON ONE BY THE CONSTRUCTION MANAGER AND IN ACCORDANCE WITH JURISDICTIONAL AUTHORITIES. AND NOT THE OTHER, IT SHALL BE DONE THE SAME AS IF SHOWN, INDICATED OR SPECIFIED IN BOTH. SHOULD THERE BE ANY DISCREPANCIES BETWEEN REQUIREMENTS SHOWN IN BOTH, 2.0 SITE PREPARATION THE MORE STRINGENT REQUIREMENTS SHALL APPLY. B. THE INTENTION OF THE DOCUMENTS IS TO INCLUDE ALL LABOR AND MATERIALS REASONABLY 2.1 SCOPE OF WOR NECESSARY FOR THE PROPER EXECUTION AND COMPLETION OF THE WORK AS STIPULATED IN K INCLUDES: THE CONTRACT. A. PROTECTION OF EXISTING TREES, VEGETATION AND LANDSCAPING MATERIALS WHICH C. THE PURPOSE OF THE AT&T WIRELESS CONSTRUCTION SPECIFICATIONS IS TO INTERPRET THE MIGHT BE DAMAGED BY CONSTRUCTION ACTIVITIES. INTENT OF THE DRAWINGS AND TO DESIGNATE THE METHOD OF THE PROCEDURE, TYPE AND B. TRIMMING O EXISTING TREES AND VEGETATION AS REQUIRED FOR PROTECTION DURING CONSTRUCTIO QUALITY OF MATERIALS REQUIRED TO COMPLETE THE WORK. N ACTIVITIES. C. CLEARING AND GRUBBING OF STUMPS, VEGETATION, DEBRIS, RUBBISH, DESIGNATED 1.2 CONFLICTS TREES; AND SITE IMPROVEMENTS. A. VERIFY ALL MEASUREMENTS AT THE SITE BEFORE ORDERING MATERIAL OR DOING ANY WORK. D. TOPSOIL STRIPPING AND STOCKPILING. NO EXTRA CHARGE OR COMPENSATION WILL BE ALLOWED DUE TO DIFFERENCES BETWEEN E• TEMPORARY EROSION CONTROL, SILTATION CONTROL AND DUST CONTROL CONFORMING ACTUAL DIMENSIONS OR DIMENSIONS SHOWN ON PLANS. SUBMIT NOTICE OF ANY DISCREPANCY TO LOCAL REQUIREMENTS AS APPLICABLE. IN DIMENSIONS OR OTHERWISE TO AT&T WIRELESS FOR RESOLUTION BEFORE PROCEEDING WITH F TEMPORARY PROTECTION OF ADJACENT PROPERTY, STRUCTURES, BENCHMARKS AND THE WORK. MONUMENTS. G. PROTECTION AND TEMPORARY RELOCATION, STORAGE AND RE—INSTALLATION OF DUSTING B. NO PLEA OF IGNORANCE OF CONDITIONS THAT EXIST OR OF DIFFICULTIES OF CONDITIONS THAT FENCING AND OTHER SITE IMPROVEMENTS SCHEDULED FOR REUSE. MAY BE ENCOUNTERED, OR OF ANY OTHER RELEVANT MATTER CONCERNING THE EXECUTION OF H• REMOVAL AND LEGAL DISPOSAL OF CLEARED MATERIALS. THE WORK WILL BE ACCEPTED AS AN EXCUSE FOR ANY FAILURE OR OMISSION ON THE PART OF THE CONTRACTOR TO FULFILL EVERY DETAIL OF ALL THE REQUIREMENTS OF THE 2.2 PRODUCTS AND MATERIALS (AS APPROVED BY CONSTRUCTION MANAGER OR AS NOTED CONSTRUCTION DOCUMENTS GOVERNING THE WORK. III CONSTRUCTION DOCUMENTS.) A. MATERIALS USED FOR TREE PROTECTION, EROSION CONTROL, SILTATION CONTROL AND 1.3 CLEANING DUST CONTROL AS SUITABLE FOR SPECIFIC SITE CONDITIONS. KEEP THE SITE FREE FROM ACCUMULATION OF WASTE AND RUBBISH CAUSED BY EMPLOYEES AT THE COMPLETION OF THE WORK. REMOVE ALL WASTE AND NON—CONSTRUCTION 3.0 EARTH WORK MATERIAL INCLUDING ALL CONTRACTOR TOOLS, SCAFFOLDING AND SURPLUS MATERIAL AND LEAVE SITE CLEAN AND READY FOR USE. 3.1 SCOPE OF WORK INCLUDES: A. EXCAVATION, TRENCHING, FILLING, COMPACTION, AND GRADING FOR STRUCTURES, SITE 1.4 CODES IMPROVEMENTS AND UTILITIES. CONTRACTOR SHALL. BE RESPONSIBLE FOR FOLLOWING ALL LAWS, REGULATIONS AND RULES B. MATERIALS FOR SUB—BASE DRAINAGE FILL, FILL, BACKFILL AND GRAVEL FOR SLABS, PROMULGATED BY FEDERAL STATE AND LOCAL AUTHORITIES WITH JURISDICTION OVER THE SITE. PAVEMENTS AND IMPROVEMENTS. THIS RESPONSIBILITY IS IN EFFECT REGARDLESS OF WHETHER THE LAW, ORDINANCE, C. ROCK EXCAVATION WITHOUT BLASTING. REGULATION OR RULE IS MENTIONED IN THESE SPECIFICATIONS. D. SUPPLY OF ADDITIONAL MATERIALS FROM OFFSITE AS REQUIRED. 1.5 LICENSING E. REMOVAL AND LEGAL DISPOSAL OF EXCAVATED MATERIALS AS REQUIRED HAVE AND MAINTAIN A VALID CONTRACTORS LICENSE FOR THE LOCATION IN WHICH THE WORK 3.2 QUALITY ASSURANCE IS TO BE PERFORMED. FOR JURISDICTIONS THAT LICENSE INDIVIDUAL TRADES, THE TRADESMAN A. COMPACTION: OR SUBCONTRACTORS PERFORMING THOSE TRADES SHALL BE LICENSED. RESEARCH AND 1 • UNDER STRUCTURES, BUILDING SLABS, PAVEMENTS AND WALKWAYS WILL OBTAIN A COMPLY WITH LICENSING LAWS, PAY LICENSE FEES, AND SELECT AND INFORM 95 PERCENT COMPACTION AT A MAXIMUM DRY DENSITY AS DETERMINED BY ASTM v SUBCONTRACTORS REGARDING THESE LAWS. 0-1557 OR WITHIN PLUS OR MINUS 3 PERCENT OF OPTIMUM MOISTURE. B. GRADING TOLERANCES OUTSIDE BUILDING CODES: 1.6 OSHA 1. LAWNS, UNPAVED AREAS AND WALKS PLUS OR MINUS 1 INCH. FOLLOW ALL APPLICABLE RULES AND REGULATIONS OF THE OCCUPATIONAL SAFETY 2. UNDER PAVEMENTS PLUS OR MINUS 1/2 INCH. AND HEALTH ADMINISTRATIONS, AND STATE LAWS BASED IN THE FEDERAL OCCUPATIONAL SAFETY C. GRADING TOLERANCE FOR FILL UNDER ALL CONCRETE APPLICATIONS: PLUS OR AND HEALTH ACT. _THESE REGULATIONS INCLUDE BUT ARE NOT LIMITED TO REGULATIONS MINUS 1/2 INCH MEASURED WITH 10 FOOT STRAIGHTEDGE. DEALING WITH TOWER CONSTRUCTION AND SAFETY, EXCAVATIONS AND TRENCHING, AND WORK IN CONFINED SPACES. ENSURE THAT EMPLOYEES AND SUBCONTRACTORS WEAR HARD HATS AT All -3-3, PRODUCTS AND MATERIALS (AS APPROVED BY CO TIMES DURING CONSTRUCTION.NSTRUCTION MANAGER OR AS NOTED _ IN CONSTRUCTION DOCUMENTS.) 1.7 PHOTOS A. SUBBASE MATERIAL GRADED MIXTURE OF NATURAL OR CRUSHED GRAVEL, CRUSHED STONE OR SLAG. AND NATURAL SAND. PROVIDE PHOTOGRAPHIC EVIDENCE OF ALL SCOPE RELATED WORK, INCLUDING BUT NOT LIMITED B. WASHED MATERIAL EVENLY GRADED TO GROUNDING AND TRENCHING AFTER PLACEMENT OF UTILITIES PRIOR TO BACKFILL. PERCENT PASSING A 1 TO OF CRUSHED STONE OR GRAVEL WITH 95 1 /2 INCH SIEVE. 1.8 BUILDING PERMITS C. GRADING MATERIAL WILL CONSIST OF: SATISFACTORY NATIVE OR 'IMPORTED SOIL MATERIALS FREE Of CLAY, ROCK OR GRAVEL NOT LARGER THAN 2 INCHES IN ANY ` AT&T WIRELESS WILL SUBMIT CONSTRUCTION DOCUMENTS TO THE JURISDICTIONAL AUTHORITY DIMENSION, DEBRIS, WASTE FROZEN MATERIALS AND OTHER UNSUITABLE MATERIALS OR PLAN CHECK AND REVIEW. CONTRACTOR WILL SUBMIT LICENSING AND WORKMAN'S WILL NOT BE ALLOWED FOR USE. IMPORTED MATERIALS SHALL HAVE A CLAY CO COMPENSATION INFORMATION TO THE JURISDICTION AS REQUIRED TO OBTAIN THE NO MORE THAN 5 PERCENT. NTENT BUILDING PERMIT. CONTRACTOR SHALL COORDINATE AND SCHEDULE REQUIRED INSPECTIONS D. _ BAC KFIL L MAT ERIA LS WILL CO NS I ST OF : SA TIS F AC TO RY N ON — COHE S IVE NAT IV E AND POST REQUIRED PERMITS AT THE JOB SITE. COMPLY WITH SPECIFIC PROJECT—RELATED IMPORTED SOIL MATERIALS FREE CLAY, ROCK GRAVEL NOTLARGER THAN 4REQUESTS AND BY INSPECTOR INFORM INCHES IN DIMENSION, WASTE FROZEN MATERIALS AND OTHERMANAGER0FANYSUCH WORK THAT BE BEYOND THE SCOPE OF THE CONTRACT OR UNSUITABLE MATERIALS. IMPORTED MATERIAL SHALL HAVE A CLAY CONTENT OF NO DEVIATE FROM THE CONSTRUCTION DOCUMENTS. AT&T WIRELESS WILL REIMBURSE THE MORE THAN 5 PERCENT. CONTRACTOR FOR FEES FOR PLAN REVIEW, BUILDING PERMIT, CONNECTIONS AND INSPECTION. E. GRAVEL MATERIAL EVENLY GRADED MIXTURE OF CRUSHED STONE OR GRAVEL WITH 95 1.9 ZONING REGULATIONS AND CONDITIONAL USE PERMITSPERCENT PASSING A 1 1/2 INCH SIEVE. AT&T WIRELESS WILL SUBMIT FOR AND OBTAIN ALL ZONING AND CONDITIONAL USE PERMITS. F. GEOTEXTILE FABRIC: AS PER CONSTRUCTION DOCUMENTS. SOME USE PERMITS MAY HAVE SPECIFIC REQUIREMENTS RELATED TO THE CONSTRUCTION SUCH 3.4 CLEARING AND GRUBS AS NOISE REGULATIONS, HOURS OF WORK, GRUBBING REMOVE ALL VEGETATION AND MATERIALS AS REQUIRED. ACCESS LIMITATIONS, ETC. THE CONSTRUCTION REMOVE STUMPS COMPLETELY UNDER FOUNDATIONS AND ROADWAY. DISPOSE OF MANAGER WILL INFORM THE CONTRACTOR OF THESE REQUIREMENTS AT THE PRE—BID MEETING CLEARING AND GRUBBING OFF—SITE, OR IN AN ON—SITE LOCATION APPROVED BY OR AS SHOWN IN CONSTRUCTION DOCUMENTS. CONSTRUCTION MANAGER. 1.10 FM PERMIT AND TOWER LIGHTING 3.5 STRIPPING REFER TO CONSTRUCTION DOCUMENTS AND CONSTRUCTION MANAGER FOR FAA AND STATE STRIP NOT LESS THAN 3 INCHES OF S OD LIGHTING REQUIREMENTS. CONTRACTOR SHALL PROVIDE TEMPORARY FM APPROVED LIGHTING UNDERLAY GRAVEL PAVEMENT, NEW STRUCTURESOR NEW AREAS THAT WILL UNTIL PERMANENT LIGHTING IS OPERATIONAL EMBANKMENTS. STOCKPILE .STRIPPING ON—SITE FOR RE—USE IN FINAL LANDSCAPING. 1.11 TOWER SECURITY 3.6 COMMON EXCAVATION TOWER MUST BE FENCED, TEMPORARILY OR PERMANENTLY WITHIN 24 HOURS OF ERECTION. DO A. EXCAVATE TO DEPTH, LINES AND GRADES SHOWN ON THE NOT ALLOW THE GATE ACCESSING THE TOWER AREA TO REMAIN OPEN OR UNATTENDED AT ANY 'SPECIFIED. PLANS OR AS OTHERWISE TIME FOR ANY REASON. KEEP THE GATE CLOSED AND LOCKED WHEN NOT IN USE. B. TEMPORARILY STOCKPILE ON—SITE EXCAVATION AT AN APPROVED LOCATION WITHIN THE 1.12 SITE CONTROL WORK AREA UNTIL SITE GRADING IS COMPLETE STOCKPILE SHALL NOT EXCEED 15 FEET IN HEIGHT. A. THE CONTRACTOR IS COMPLETELY RESPONSIBLE FOR CONTAINMENT OF SEDIMENT AND CONTROL C. LEGALLY DISPOSE OF EXCESS COMMON EXCAVATIO OF EROSION AT THE SITE. ANY DAMAGE TO ADJACENT OR DOWNSTREAM PROPERTIES WILL BE N OFF—SITE. CORRECTED BY THE CONTRACTOR AT NO EXPENSE TO AT&T WIRELESS. B. THE CONTRACTOR IS TO MAINTAIN ADEQUATE DRAINAGE AT ALL TIMES. DO NOT ALLOW WATER TO STAND OR POND. ANY DAMAGE TO STRUCTURES OR WORK ON THE SITE CAUSED BY INADEQUATE MAINTENANCE OF DRAINAGE PROVISIONS WILL BE THE RESPONSIBILITY OF THE CONTRACTOR AND ANY COST ASSOCIATED WITH REPAIRS FOR SUCH DAMAGE WILL BE AT THE CONTRACTOR'S EXPENSE. .01:6 imid 001 >: at&t . . . . . . . . . . . . . . . . . . . . . . . . . AT&T MOBILITY 1801 VALLEY VIEW LANE FARMERS BRANCH, TX 75234 CONSULTANT: Good man Networks 6400 INTERNATIONAL PARKWAY SUITE 1000 PLANO, TX 75093 Tel: (972) 406.9692 SITE NAME: � 1111] *A1 =I V SITE NUMBER: HX3572 SITE ADDRESS: 301 GEORGE BUSH DRIVE COLLEGE STATION, TX 77840 BRAZOS COUNTY 11/15/2013������1 PSE OF TF VP .iii+$'i•.............w�....i.... / � ANTHONY L. HUEB.!1j,0 ♦ o ; 102126 ,• �� �5%+OPAL, �', � \%!0\Nmffi0\N\1\- \\\\\\\ 4 44. " vv\mv\\\' CONSU LTING \ + EN�G�INEE�R.S, INC. 19315 FM 2252, STE. 301 PH: (210) 542-5911 GARDEN RIDGE, TX 78266 F-13646 DRAWN BY: RS APPROVED BY: TH DATE DRAWN: 10/16/13 REVISION NO DESCRIPTION BY DATE 0 ISSUED FOR CONSTRUCTION RS 10/22/13 1 REVISED PER RFDS TH 10/31/13 2 REVISED PER COMMENTS WS 11 /14/13 SHEET TITLE: GENERAL NOTES SHEET NUMBER: N1 1 AFF ABOVE FINISHED FLOOR AGL ABOVE GRADE LEVEL' AMSL ABOVE MEAN SEA LEVEL APPROX APPROXIMATE AWG AMERICAN WIRE GAUGE BLDG BUILDING BTS BASE TRANSMISSION STATION CLR CLEAR COL COLUMN CONC CONCRETE CND CONDUIT DWG DRAWING FT FOOT (FEET) EGB EQUIPMENT GROUND BAR ELEC ELECTRICAL EMT ELECTRICAL METALLIC TUBING ELEV ELEVATION EQUIP EQUIPMENT EXISTING EXISTING EXT EXTERIOR FND FOUNDATION F FIBER GA GAUGE GALV GALVANIZED GPS GLOBAL POSITIONING SYSTEM GND GROUND LTE LONG TERM EVOLUTION MAX MAXIMUM MFR MANUFACTURER MGB MASTER GROUND BAR MIN MINIMUM N.T.S. NOT TO SCALE NEW NEW - O.C. ON CENTER OE/OTOVERHEAD ELECTRIC/TELCO POWER PROTECTION CABINET RBS RADIO BASED STATION RRU REMOTE RADIO UNIT RGS RIGID GALVANIZED STEEL IN INCH(ES) INT INTERIOR LB(S) or # POUND(S) SF SQUARE FOOT STL STEEL TYP TYPICAL UE/UTUNDERGROUND ELECTRIC/TELCO UNLESS NOTED OTHERWISE VIF VERIFY IN FIELD W/ WITH XFMR TRANSFORMER LINE AND SYMBOL_ LEGEND X CHAIN—LINK FENCE BOUNDARY WOOD FENCE BOUNDARY UNDERGROUND ELECTRICAL CONDUIT AND FEEDER UNDERGROUND TELEPHONE COMPANY -CONDUIT TO TELCO DEMARK POINT H HYBRID CABLE C I MAIN COAX FEEDER T I TELCO WIRING E POWER WIRING G GROUND WIRING F FIBER CABLE ® • ♦ CONNECTION (CADWELD OR EXOTHERMIC WELD TO STRUCTURE OR DEVICE) GROUNDING BAR GROUND POINT 00 METER 0 GENERAL REQUIREMENTS 1.1 PURPOSE AND INTENT A. THE DRAWINGS AND SPECIFICATIONS ARE INTENDED TO BE FULLY EXPLANATORY AND C. ALL WASTE MATERIAL SHALL BE PROPERLY DISPOSED OF OFF—SITE OR AS DIRECTED SUPPLEMENTARY. HOWEVER, SHOULD ANYTHING BE SHOWN, INDICATED OR SPECIFIED ON ONE BY THE CONSTRUCTION MANAGER AND IN ACCORDANCE WITH JURISDICTIONAL AUTHORITIES. AND NOT THE OTHER, IT SHALL BE DONE THE SAME AS IF SHOWN, INDICATED OR SPECIFIED IN BOTH. SHOULD THERE BE ANY DISCREPANCIES BETWEEN REQUIREMENTS SHOWN IN BOTH, 2.0 SITE PREPARATION THE MORE STRINGENT REQUIREMENTS SHALL APPLY. B. THE INTENTION OF THE DOCUMENTS IS TO INCLUDE ALL LABOR AND MATERIALS REASONABLY 2.1 SCOPE OF WOR NECESSARY FOR THE PROPER EXECUTION AND COMPLETION OF THE WORK AS STIPULATED IN K INCLUDES: THE CONTRACT. A. PROTECTION OF EXISTING TREES, VEGETATION AND LANDSCAPING MATERIALS WHICH C. THE PURPOSE OF THE AT&T WIRELESS CONSTRUCTION SPECIFICATIONS IS TO INTERPRET THE MIGHT BE DAMAGED BY CONSTRUCTION ACTIVITIES. INTENT OF THE DRAWINGS AND TO DESIGNATE THE METHOD OF THE PROCEDURE, TYPE AND B. TRIMMING O EXISTING TREES AND VEGETATION AS REQUIRED FOR PROTECTION DURING CONSTRUCTIO QUALITY OF MATERIALS REQUIRED TO COMPLETE THE WORK. N ACTIVITIES. C. CLEARING AND GRUBBING OF STUMPS, VEGETATION, DEBRIS, RUBBISH, DESIGNATED 1.2 CONFLICTS TREES; AND SITE IMPROVEMENTS. A. VERIFY ALL MEASUREMENTS AT THE SITE BEFORE ORDERING MATERIAL OR DOING ANY WORK. D. TOPSOIL STRIPPING AND STOCKPILING. NO EXTRA CHARGE OR COMPENSATION WILL BE ALLOWED DUE TO DIFFERENCES BETWEEN E• TEMPORARY EROSION CONTROL, SILTATION CONTROL AND DUST CONTROL CONFORMING ACTUAL DIMENSIONS OR DIMENSIONS SHOWN ON PLANS. SUBMIT NOTICE OF ANY DISCREPANCY TO LOCAL REQUIREMENTS AS APPLICABLE. IN DIMENSIONS OR OTHERWISE TO AT&T WIRELESS FOR RESOLUTION BEFORE PROCEEDING WITH F TEMPORARY PROTECTION OF ADJACENT PROPERTY, STRUCTURES, BENCHMARKS AND THE WORK. MONUMENTS. G. PROTECTION AND TEMPORARY RELOCATION, STORAGE AND RE—INSTALLATION OF DUSTING B. NO PLEA OF IGNORANCE OF CONDITIONS THAT EXIST OR OF DIFFICULTIES OF CONDITIONS THAT FENCING AND OTHER SITE IMPROVEMENTS SCHEDULED FOR REUSE. MAY BE ENCOUNTERED, OR OF ANY OTHER RELEVANT MATTER CONCERNING THE EXECUTION OF H• REMOVAL AND LEGAL DISPOSAL OF CLEARED MATERIALS. THE WORK WILL BE ACCEPTED AS AN EXCUSE FOR ANY FAILURE OR OMISSION ON THE PART OF THE CONTRACTOR TO FULFILL EVERY DETAIL OF ALL THE REQUIREMENTS OF THE 2.2 PRODUCTS AND MATERIALS (AS APPROVED BY CONSTRUCTION MANAGER OR AS NOTED CONSTRUCTION DOCUMENTS GOVERNING THE WORK. III CONSTRUCTION DOCUMENTS.) A. MATERIALS USED FOR TREE PROTECTION, EROSION CONTROL, SILTATION CONTROL AND 1.3 CLEANING DUST CONTROL AS SUITABLE FOR SPECIFIC SITE CONDITIONS. KEEP THE SITE FREE FROM ACCUMULATION OF WASTE AND RUBBISH CAUSED BY EMPLOYEES AT THE COMPLETION OF THE WORK. REMOVE ALL WASTE AND NON—CONSTRUCTION 3.0 EARTH WORK MATERIAL INCLUDING ALL CONTRACTOR TOOLS, SCAFFOLDING AND SURPLUS MATERIAL AND LEAVE SITE CLEAN AND READY FOR USE. 3.1 SCOPE OF WORK INCLUDES: A. EXCAVATION, TRENCHING, FILLING, COMPACTION, AND GRADING FOR STRUCTURES, SITE 1.4 CODES IMPROVEMENTS AND UTILITIES. CONTRACTOR SHALL. BE RESPONSIBLE FOR FOLLOWING ALL LAWS, REGULATIONS AND RULES B. MATERIALS FOR SUB—BASE DRAINAGE FILL, FILL, BACKFILL AND GRAVEL FOR SLABS, PROMULGATED BY FEDERAL STATE AND LOCAL AUTHORITIES WITH JURISDICTION OVER THE SITE. PAVEMENTS AND IMPROVEMENTS. THIS RESPONSIBILITY IS IN EFFECT REGARDLESS OF WHETHER THE LAW, ORDINANCE, C. ROCK EXCAVATION WITHOUT BLASTING. REGULATION OR RULE IS MENTIONED IN THESE SPECIFICATIONS. D. SUPPLY OF ADDITIONAL MATERIALS FROM OFFSITE AS REQUIRED. 1.5 LICENSING E. REMOVAL AND LEGAL DISPOSAL OF EXCAVATED MATERIALS AS REQUIRED HAVE AND MAINTAIN A VALID CONTRACTORS LICENSE FOR THE LOCATION IN WHICH THE WORK 3.2 QUALITY ASSURANCE IS TO BE PERFORMED. FOR JURISDICTIONS THAT LICENSE INDIVIDUAL TRADES, THE TRADESMAN A. COMPACTION: OR SUBCONTRACTORS PERFORMING THOSE TRADES SHALL BE LICENSED. RESEARCH AND 1 • UNDER STRUCTURES, BUILDING SLABS, PAVEMENTS AND WALKWAYS WILL OBTAIN A COMPLY WITH LICENSING LAWS, PAY LICENSE FEES, AND SELECT AND INFORM 95 PERCENT COMPACTION AT A MAXIMUM DRY DENSITY AS DETERMINED BY ASTM v SUBCONTRACTORS REGARDING THESE LAWS. 0-1557 OR WITHIN PLUS OR MINUS 3 PERCENT OF OPTIMUM MOISTURE. B. GRADING TOLERANCES OUTSIDE BUILDING CODES: 1.6 OSHA 1. LAWNS, UNPAVED AREAS AND WALKS PLUS OR MINUS 1 INCH. FOLLOW ALL APPLICABLE RULES AND REGULATIONS OF THE OCCUPATIONAL SAFETY 2. UNDER PAVEMENTS PLUS OR MINUS 1/2 INCH. AND HEALTH ADMINISTRATIONS, AND STATE LAWS BASED IN THE FEDERAL OCCUPATIONAL SAFETY C. GRADING TOLERANCE FOR FILL UNDER ALL CONCRETE APPLICATIONS: PLUS OR AND HEALTH ACT. _THESE REGULATIONS INCLUDE BUT ARE NOT LIMITED TO REGULATIONS MINUS 1/2 INCH MEASURED WITH 10 FOOT STRAIGHTEDGE. DEALING WITH TOWER CONSTRUCTION AND SAFETY, EXCAVATIONS AND TRENCHING, AND WORK IN CONFINED SPACES. ENSURE THAT EMPLOYEES AND SUBCONTRACTORS WEAR HARD HATS AT All -3-3, PRODUCTS AND MATERIALS (AS APPROVED BY CO TIMES DURING CONSTRUCTION.NSTRUCTION MANAGER OR AS NOTED _ IN CONSTRUCTION DOCUMENTS.) 1.7 PHOTOS A. SUBBASE MATERIAL GRADED MIXTURE OF NATURAL OR CRUSHED GRAVEL, CRUSHED STONE OR SLAG. AND NATURAL SAND. PROVIDE PHOTOGRAPHIC EVIDENCE OF ALL SCOPE RELATED WORK, INCLUDING BUT NOT LIMITED B. WASHED MATERIAL EVENLY GRADED TO GROUNDING AND TRENCHING AFTER PLACEMENT OF UTILITIES PRIOR TO BACKFILL. PERCENT PASSING A 1 TO OF CRUSHED STONE OR GRAVEL WITH 95 1 /2 INCH SIEVE. 1.8 BUILDING PERMITS C. GRADING MATERIAL WILL CONSIST OF: SATISFACTORY NATIVE OR 'IMPORTED SOIL MATERIALS FREE Of CLAY, ROCK OR GRAVEL NOT LARGER THAN 2 INCHES IN ANY ` AT&T WIRELESS WILL SUBMIT CONSTRUCTION DOCUMENTS TO THE JURISDICTIONAL AUTHORITY DIMENSION, DEBRIS, WASTE FROZEN MATERIALS AND OTHER UNSUITABLE MATERIALS OR PLAN CHECK AND REVIEW. CONTRACTOR WILL SUBMIT LICENSING AND WORKMAN'S WILL NOT BE ALLOWED FOR USE. IMPORTED MATERIALS SHALL HAVE A CLAY CO COMPENSATION INFORMATION TO THE JURISDICTION AS REQUIRED TO OBTAIN THE NO MORE THAN 5 PERCENT. NTENT BUILDING PERMIT. CONTRACTOR SHALL COORDINATE AND SCHEDULE REQUIRED INSPECTIONS D. _ BAC KFIL L MAT ERIA LS WILL CO NS I ST OF : SA TIS F AC TO RY N ON — COHE S IVE NAT IV E AND POST REQUIRED PERMITS AT THE JOB SITE. COMPLY WITH SPECIFIC PROJECT—RELATED IMPORTED SOIL MATERIALS FREE CLAY, ROCK GRAVEL NOTLARGER THAN 4REQUESTS AND BY INSPECTOR INFORM INCHES IN DIMENSION, WASTE FROZEN MATERIALS AND OTHERMANAGER0FANYSUCH WORK THAT BE BEYOND THE SCOPE OF THE CONTRACT OR UNSUITABLE MATERIALS. IMPORTED MATERIAL SHALL HAVE A CLAY CONTENT OF NO DEVIATE FROM THE CONSTRUCTION DOCUMENTS. AT&T WIRELESS WILL REIMBURSE THE MORE THAN 5 PERCENT. CONTRACTOR FOR FEES FOR PLAN REVIEW, BUILDING PERMIT, CONNECTIONS AND INSPECTION. E. GRAVEL MATERIAL EVENLY GRADED MIXTURE OF CRUSHED STONE OR GRAVEL WITH 95 1.9 ZONING REGULATIONS AND CONDITIONAL USE PERMITSPERCENT PASSING A 1 1/2 INCH SIEVE. AT&T WIRELESS WILL SUBMIT FOR AND OBTAIN ALL ZONING AND CONDITIONAL USE PERMITS. F. GEOTEXTILE FABRIC: AS PER CONSTRUCTION DOCUMENTS. SOME USE PERMITS MAY HAVE SPECIFIC REQUIREMENTS RELATED TO THE CONSTRUCTION SUCH 3.4 CLEARING AND GRUBS AS NOISE REGULATIONS, HOURS OF WORK, GRUBBING REMOVE ALL VEGETATION AND MATERIALS AS REQUIRED. ACCESS LIMITATIONS, ETC. THE CONSTRUCTION REMOVE STUMPS COMPLETELY UNDER FOUNDATIONS AND ROADWAY. DISPOSE OF MANAGER WILL INFORM THE CONTRACTOR OF THESE REQUIREMENTS AT THE PRE—BID MEETING CLEARING AND GRUBBING OFF—SITE, OR IN AN ON—SITE LOCATION APPROVED BY OR AS SHOWN IN CONSTRUCTION DOCUMENTS. CONSTRUCTION MANAGER. 1.10 FM PERMIT AND TOWER LIGHTING 3.5 STRIPPING REFER TO CONSTRUCTION DOCUMENTS AND CONSTRUCTION MANAGER FOR FAA AND STATE STRIP NOT LESS THAN 3 INCHES OF S OD LIGHTING REQUIREMENTS. CONTRACTOR SHALL PROVIDE TEMPORARY FM APPROVED LIGHTING UNDERLAY GRAVEL PAVEMENT, NEW STRUCTURESOR NEW AREAS THAT WILL UNTIL PERMANENT LIGHTING IS OPERATIONAL EMBANKMENTS. STOCKPILE .STRIPPING ON—SITE FOR RE—USE IN FINAL LANDSCAPING. 1.11 TOWER SECURITY 3.6 COMMON EXCAVATION TOWER MUST BE FENCED, TEMPORARILY OR PERMANENTLY WITHIN 24 HOURS OF ERECTION. DO A. EXCAVATE TO DEPTH, LINES AND GRADES SHOWN ON THE NOT ALLOW THE GATE ACCESSING THE TOWER AREA TO REMAIN OPEN OR UNATTENDED AT ANY 'SPECIFIED. PLANS OR AS OTHERWISE TIME FOR ANY REASON. KEEP THE GATE CLOSED AND LOCKED WHEN NOT IN USE. B. TEMPORARILY STOCKPILE ON—SITE EXCAVATION AT AN APPROVED LOCATION WITHIN THE 1.12 SITE CONTROL WORK AREA UNTIL SITE GRADING IS COMPLETE STOCKPILE SHALL NOT EXCEED 15 FEET IN HEIGHT. A. THE CONTRACTOR IS COMPLETELY RESPONSIBLE FOR CONTAINMENT OF SEDIMENT AND CONTROL C. LEGALLY DISPOSE OF EXCESS COMMON EXCAVATIO OF EROSION AT THE SITE. ANY DAMAGE TO ADJACENT OR DOWNSTREAM PROPERTIES WILL BE N OFF—SITE. CORRECTED BY THE CONTRACTOR AT NO EXPENSE TO AT&T WIRELESS. B. THE CONTRACTOR IS TO MAINTAIN ADEQUATE DRAINAGE AT ALL TIMES. DO NOT ALLOW WATER TO STAND OR POND. ANY DAMAGE TO STRUCTURES OR WORK ON THE SITE CAUSED BY INADEQUATE MAINTENANCE OF DRAINAGE PROVISIONS WILL BE THE RESPONSIBILITY OF THE CONTRACTOR AND ANY COST ASSOCIATED WITH REPAIRS FOR SUCH DAMAGE WILL BE AT THE CONTRACTOR'S EXPENSE. .01:6 imid 001 >: at&t . . . . . . . . . . . . . . . . . . . . . . . . . AT&T MOBILITY 1801 VALLEY VIEW LANE FARMERS BRANCH, TX 75234 CONSULTANT: Good man Networks 6400 INTERNATIONAL PARKWAY SUITE 1000 PLANO, TX 75093 Tel: (972) 406.9692 SITE NAME: � 1111] *A1 =I V SITE NUMBER: HX3572 SITE ADDRESS: 301 GEORGE BUSH DRIVE COLLEGE STATION, TX 77840 BRAZOS COUNTY 11/15/2013������1 PSE OF TF VP .iii+$'i•.............w�....i.... / � ANTHONY L. HUEB.!1j,0 ♦ o ; 102126 ,• �� �5%+OPAL, �', � \%!0\Nmffi0\N\1\- \\\\\\\ 4 44. " vv\mv\\\' CONSU LTING \ + EN�G�INEE�R.S, INC. 19315 FM 2252, STE. 301 PH: (210) 542-5911 GARDEN RIDGE, TX 78266 F-13646 DRAWN BY: RS APPROVED BY: TH DATE DRAWN: 10/16/13 REVISION NO DESCRIPTION BY DATE 0 ISSUED FOR CONSTRUCTION RS 10/22/13 1 REVISED PER RFDS TH 10/31/13 2 REVISED PER COMMENTS WS 11 /14/13 SHEET TITLE: GENERAL NOTES SHEET NUMBER: N1 1 3.7 EMBANKMENT A. CONSTRUCT EMBANKMENT TO THE LINES AND GRADE SHOWN ON THE DRAWINGS. B. CONSTRUCT EMBANKMENT FROM ON-SITE EXCAVATION MATERIALS WHEN SUITABLE USE IMPORTED BACKFILL ONLY AFTER AVAILABLE ON-SITE EXCAVATION MATERIALS HAVE BEEN USED. C. CONSTRUCT IN LIFTS OF NOT MORE THAN 12 INCHES IN LOOSE DEPTH. THE FULL WIDTH Of THE CROSS SECTION SHALL BE BROUGHT UP UNIFORMLY. D. MATERIAL SHALL NOT BE PLACED IN LAYERS AND SHALL BE NEAR OPTIMUM MOISTURE CONTENT BEFORE ROLLING TO OBTAIN THE PRESCRIBED COMPACTION. WETTING DR DRYING OF THE MATERIAL AND MANIPULATION TO SECURE A UNIFORM MOISTURE CONTENT THROUGHOUT THE LAYER MAY BE REQUIRED. SUCH OPERATIONS SHALL BE INCLUDED IN THE APPROPRIATE BID ITEM. SHOULD THE MATERIAL BE TOO WET TO PERMIT PROPER COMPACTION, IT IS THE CONTRACTOR'S RESPONSIBILITY TO UTILIZE MATERIAL WITH AN ACCEPTABLE MOISTURE CONTENT. E. DO NOT PLACE FROZEN MATERIAL IN THE EMBANKMENT AND DO NOT PLACE EMBANKMENT MATERIAL UPON FROZEN MATERIAL. F. CONTRACTOR SHALL BE RESPONSIBLE FOR THE STABILITY OF EMBANKMENTS AND THE REPLACEMENT OF ANY PORTION WHICH HAS BECOME DISPLACED DUE TO THE CONTRACTORS OPERATIONS. G. START LAYERS IN THE DEEPEST PORTION OF THE FILL, AND AS PLACEMENT PROGRESSES, CONSTRUCT LAYERS APPROXIMATELY PARALLEL TO THE FINISHED GRADE LINE. H. ROUTE EQUIPMENT, BOTH LOADED AND EMPTY, OVER THE FULL WIDTH OF EMBANKMENT TO ENSURE UNIFORMITY OF MATERIAL PLACEMENT. I. COMPACT EMBANKMENT UNDERLYING NEW GRAVEL PAVING FLOOR SLABS AND STRUCTURES TO A 95 PERCENT COMPACTION AT A MAXIMUM DRY DENSITY AS DETERMINED BY ASTM 0-1557 OR WITHIN PLUS OR MINUS 3 PERCENT OF OPTIMUM MOISTURE CONTENT. COMPACT NON-STRUCTURAL -AREA EMBANKMENTS TO A MINIMUM OF 90 % OF ASTM 0-1557. 3.8 SITE GRADING A. USING ON-SITE EXCAVATION MATERIALS SHAPE, TRIM, FINISH AND COMPACT SURFACE AREAS TO CONFORM TO THE LINES, GRADES AND CROSS SECTIONS SHOWN ON THE DRAWINGS OR AS DESIGNATED BY THE CONSTRUCTION MANAGER. B. GRADE SURFACES TO DRAIN AND ELIMINATE ANY PONDING OR EROSION. C. ELIMINATE WHEEL RUTS BY REGRADING. D. COMPACT AREAS UNDERLYING NEW GRAVEL PAVING, FLOOR SLABS AND STRUCTURES TO A 95 PERCENT COMPACTION AT A MAXIMUM DRY DENSITY AS DETERMINED BY ASTM D-1551 OR WITHIN PLUS OR MINUS 3 PERCENT OF OPTIMUM MOISTURE CONTENT. E. CONSTRUCT FINISHED SURFACE OF SITE GRADING AREAS WITHIN ONE INCH FROM SPECIFIED GRADE 3.9 SUBGRADE PREPARATION A. SHAPE TOP OF SUBGRADE TO THE LINES AND GRADES- SHOWN ON THE DRAWINGS. B. MAINTAIN TOP OF SUBGRADE TO A FREE -DRAINING CONDITION. C. DO NOT STOCKPILE MATERIALS ON TOP OF SUBGRADE UNLESS AUTHORIZED BY CONSTRUCTION MANAGER. D. COMPACT THE TOP 12 INCHES OF SUBGRADE TO A 95% COMPACTION AT A MAXIMUM DRY DENSITY AS DETERMINED BY ASTM 0-1557 OR WITHIN PLUS OR MINUS 3 PERCENT OF OPTIMUM MOISTURE CONTENT. E. CONSTRUCT TOP OF SUBGRADE WITHIN ONE INCH Of ESTABLISHED GRADE AND CROSS-SECTION. 3.10 GEOTEXTILE FABRIC A. LAY GEOTEXTILE FABRIC OVER COMPACTED SUBGRADE AS PER CONSTRUCTION DOCUMENTS IN THE COMPOUND AREA AND UNDER LENGTH OF ROAD (WHEN REQUIRED). LAP ALL JOINTS TO A MINIMUM Of 36 INCHES. 3.11 GRAVEL SURFACING RUSHED AGGREGATE BASE GRAVEL SURFACING AREAS USING C A. CONSTRUCT AND FINISH COURSES AS SPECIFIED BY CONSTRUCTION MANAGER OR CONSTRUCTION DOCUMENTS. B. SPREAD GRAVEL AND RAKE TO OBTAIN A UNIFORM SURFACE AREA. 4.0 TRENCHING CALL LOCAL UNDERGROUND UTILITY LOCATING SERVICE BEFORE ANY EXCAVATION OR TRENCHING. C. DISPOSE OF EXCESS AND UNSUITABLE EXCAVATION MATERIAL PROPERLY, AS DIRECTED BY CONSTRUCTION MANAGER. D. USE HAND METHODS FOR EXCAVATION THAT CANNOT BE ACCOMPLISHED WITHOUT ENDANGERING EXISTING OR NEW STRUCTURES OR OTHER FACILITIES. 4.4 TRENCH PROTECTION A. PROVIDE MATERIALS, LABOR AND EQUIPMENT NECESSARY TO PROTECT C. UPON COMPLETION, REMOVE ALL FORMS, INCLUDING THOSE CONCEALED OR BURIED. D. REFER TO STRUCTURAL DRAWINGS FOR ADDITIONAL REQUIREMENTS. 8.0 CONCRETE REINFORCEMENT REFER TO STRUCTURAL DRAWINGS FOR ALL REQUIREMENTS. 4.1 MATERIALS FILL MATERIAL SHALL BE OBTAINED, WHEN POSSIBLE FROM MATERIALS EXCAVATED FROM TRENCHES. ON-SITE STRUCTURAL FILL SAND OR SLURRY SHALL BE APPROVED BY THE CONSTRUCTION MANAGER AND SHALL CONFORM TO LOCAL GOVERNING JURISDICTIONS AND UTILITY COMPANY REQUIREMENTS. THE FILL MATERIAL SHALL CONTAIN NO ORGANIC MATERIAL OR ROCKS, NOR SHALL CONTAIN OBJECTIONABLE MATERIALS AND/OR MATERIALS DESIGNATED AS HAZARDOUS OR INDUSTRIAL BY THE ENVIRONMENTAL PROTECTION AGENCY (EPA). THE FILL MATERIAL SHALL CONTAIN FINES SUFFICIENT TO FILL ALL VOIDS IN THE MATERIAL COMPACTION OF BACKFILL OR BORROW SOIL SHALL BE PLACED IN 12 INCH LOOSE LIFTS WHEN UTILIZING HEAVY COMPACTION EQUIPMENT OR 6 INCH LOOSE LIFTS WHEN UTILIZING HAND OPERATED TAMPERS. 4.2 PIPE DETECTION AND IDENTIFICATION A. UTILIZING WARNING TAPE: ALL ELECTRIC SERVICE TRENCHES SHALL BE MARKED WITH WARNING TAPE. 4.3 TRENCH EXCAVATION A. DIG TRENCH TO LINES AND GRADES SHOWN ON THE PLANS OR AS DIRECTED BY CONSTRUCTION MANAGER. B. TRENCH LENGTH SHALL BE SUFFICIENT TO ALLOW FOR SATISFACTORY CONSTRUCTION AND INSPECTION OF THE PROJECT WITHOUT ENDANGERING OTHER CONSTRUCTION WORK OR ADJACENT FACILITIES. TRENCHES AT ALL TIMES. 9.0 CAST IN PLACE CONCRETE B. SHEETING AND BRACING: MEET OR EXCEED OSHA REQUIREMENTS. FOR STRUCTURAL CONCRETE (FOOTINGS, FOUNDATIONS. ETC.), REFER TO F 669. F. STRUCTURAL DRAWINGS FOR REQUIREMENTS. FOR ANY MISCELLANEOUS 4.5 BACKFILLING RS CONCRETE, REFER TO SPECIFICATION BOOK OR OBTAIN REQUIREMENTS FROM A. NOTIFY THE CONSTRUCTION MANAGER AT LEAST 24 HOURS IN ADVANCE OF CONSTRUCTION MANAGER. 10/16/13 BACKFILLING. A. ALL CONCRETE SHALL COMPLY WITH ASTM C94 UNLESS NOTED B. BACKFILL TRENCH WITH LIFTS UP TO 12 INCHES, LOOSE MEASURE. OTHERWISE. C. PROTECT CONDUIT FROM LATERAL MOVEMENT, DAMAGE FROM IMPACT OR B. MINIMUM COMPRESSIVE STRENGTH (F'C) AT 28 OATS: 4000 PSI FOR UNBALANCED LOADING TO AVOID DISPLACEMENT OF CONDUIT AND/OR TOWER FOUNDATION AND 3500 PSI FOR ALL OTHER CONCRETE UNLESS STRUCTURES. DO NOT FREE FALL BACKFILL INTO TRENCH UNTIL AT LEAST 12 SPECIFIED IN CONSTRUCTION DOCUMENTS. INCHES OF COVER IS OVER THE CONDUIT. C. AIR ENTRAINMENT: PROVIDE 4 TO 8% AIR ENTRAINMENT FOR ALL PROVIDE MEANS FOR ATTACHING TOP RAIL SECURELY TO EACH GATE CONCRETE SUBJECT TO FREEZE -THAW CYCLE. 4.6 COMPACTION D. CONCRETE TESTING: ALL FOUNDATION CONCRETE SHALL BE TESTED BY A. COMPACT BACKFILL TO A 95 PERCENT COMPACTION AT A MAXIMUM DRY AN INDEPENDENT TESTING AGENCY APPROVED BY THE CONSTRUCTION DENSITY AS DETERMINED BY ASTM 0-1557 OR WITHIN PLUS OR MINUS 3 MANAGER. ALL STRUCTURAL TOWER FOUNDATION CONCRETE MUST BE PERCENT OF OPTIMUM MOISTURE CONTENT. EQUIPMENT OR BUILDING PADS ARE NOT REQUIRED TO BE B. IF REQUIRED COMPACTION DENSITY HAS NOT BEEN OBTAINED, REMOVE THE TESTED, UNLESS OTHERWISE NOTED BY CONSTRUCTION MANAGER. BACKFILL FROM THE TRENCH OR STRUCTURE, REPLACE WITH APPROVED PROVIDE A MINIMUM OF 5 CYLINDERS (2 -7 -DAY, 2 -28 -DAY, BACKFILL AND RECOMPACT AS SPECIFIED. 1 -SPARE) FOR EACH OATS POUR, OR FOR EVERY 50 YARDS PLACED, C. ANY SUBSEQUENT SETTLEMENT OF TRENCH OR STRUCTURE BACKFILL DURING WHICHEVER 15 GREATER. ADDITIONAL TESTS OR CYLINDERS MAY BE MAINTENANCE PERIOD SHALL BE CONSIDERED THE RESULT OF IMPROPER REQUIRED BY CONSTRUCTION MANAGER. A SLUMP, AIR, AND COMPACTION AND SHALL BE PROMPTLY CORRECTED. G. TEMPERATURE TEST SHALL BE PERFORMED FOR EACH SET OF 2. LATCH: MTS MULTI -LOCKING DEVICE MT -C6477 OR APPROVED EQUAL. CYLINDERS CAST. PREFERABLY, TESTS SHALL BE PERFORMED AT THE 5.0 CHAIN LINK FENCES AND GATES LOCATION OF ANCHOR BOLTS (PIERS - FOR MAT & PIERS, CAISSONS 5.1 GENERAL TOP 1/3 OF CAISSON). TESTS SHALL ALSO BE REQUIRED FOR A. PROVIDE CHAIN LINK FENCES AND GATES AS COMPLETE UNITS BY A SINGLE CONCRETE CONSIDERED BEING LESS THAN DESIRABLE BY CONCRETE F. SUPPLY SOURCE INCLUDING NECESSARY ERECTION ACCESSORIES, FITTINGS SPECIFICATION STANDARDS. THE TESTING AGENCY HAS THE AUTHORITY AND FASTENERS. TO NOT ACCEPT ;CONCRETE MEETING THESE SPECIFICATIONS FOR AT&T AGGREGATES ASTM C 33, AND CLEAN WATER. MIX MATERIALS TO OBTAIN WIRELESS. THE CONTRACTOR IS RESPONSIBLE FOR ANY CONCRETE NOT 5.2 PRODUCTS AND MATERIALS (AS APPROVED BY CONSTRUCTION MANAGER OR MEETING THESE STANDARDS. THE CONTRACTOR IS RESPONSIBLE FOR AS WITHIN CONSTRUCTION DOCUMENTS) COORDINATION OF THE TESTING AGENCY A MINIMUM OF 24 HOURS IN 6.0 LANDSCAPING 10.0 ADVANCE OF EACH FOUNDATION POUR. TEST REPORTS SHALL BE A. COMPOUND FABRIC 84 INCHES HIGH AND OVER WITH 2 -INCH MESH SHALL FORWARDED TO AT&T CONSTRUCTION MANAGER WITHIN 24 HOURS OF BE KNUCKLED AT ONE SELVAGE AND TWISTED AT THE OTHER. LAB TEST. B. STEEL FABRIC: E. VIBRATE ALL CONCRETE USING SUFFICIENT HIGH FREQUENCY LOW COMPLY WITH CHAIN LINK FENCE MANUFACTURERS INSTITUTE (CLFMI) A. AMPLITUDE MECHANICAL IMMERSION TYPE VIBRATORS. INSERT VIBRATORS 7.0 PRODUCT MANUAL. FURNISH ONE PIECE OF FABRIC WIDTHS. WIRE SIZE IN CONCRETE AT REGULAR INTERVALS AND OVER ENTIRE SURFACE TO A. INCLUDES ZINC OR ALUMINUM COATING. SOLIDLY FILL CONCRETE MECHANICAL IMMERSION TYPE VIBRATORS. 1. SIZE: 2 -INCH MESH 9 GAUGE (D.148 -INCH DIAMETER) WIRE. B. INSERT VIBRATORS IN CONCRETE AT REGULAR INTERVALS AND OVER _ B. 2. GALVANIZED STEEL FINISH: ASTM A 392. CLASS 2. WITH A MINIMUM 2.0 ENTIRE SURFACE TO SOLIDLY FILL CONCRETE AROUND AND BETWEEN OZ. ZINC PER SQ. FT. OF UNCOATED WIRE SURFACE. C. REINFORCEMENT BARS AND INTO CORNERS AND IRREGULARITIES. A. FRAMEWORK AND ACCESSORIES: VIBRATE THOROUGHLY THROUGH EACH LIFT TO THE PREVIOUS LIFE _ 1. GENERAL REQUIREMENTS: EXCEPT AS INDICATED OTHERWISE CONFORM REVERBERATION AS LATE AS THE RUNNING VIBRATOR WILL SINK TO THE CHAIN LINK FENCE MANUFACTURERS INSTITUTE (CLFMI)_ THROUGH UPPER LAYERS OF ITS WEIGHT IS RECOMMENDED. PRODUCT MANUAL INDUSTRIAL STEEL GUIDE FOR FENCE RAILS, POSTS, DISCONTINUE VIBRATION WHEN RISING ENTRAPPED AIR BUBBLES STOP - 4.1 MATERIALS FILL MATERIAL SHALL BE OBTAINED, WHEN POSSIBLE FROM MATERIALS EXCAVATED FROM TRENCHES. ON-SITE STRUCTURAL FILL SAND OR SLURRY SHALL BE APPROVED BY THE CONSTRUCTION MANAGER AND SHALL CONFORM TO LOCAL GOVERNING JURISDICTIONS AND UTILITY COMPANY REQUIREMENTS. THE FILL MATERIAL SHALL CONTAIN NO ORGANIC MATERIAL OR ROCKS, NOR SHALL CONTAIN OBJECTIONABLE MATERIALS AND/OR MATERIALS DESIGNATED AS HAZARDOUS OR INDUSTRIAL BY THE ENVIRONMENTAL PROTECTION AGENCY (EPA). THE FILL MATERIAL SHALL CONTAIN FINES SUFFICIENT TO FILL ALL VOIDS IN THE MATERIAL COMPACTION OF BACKFILL OR BORROW SOIL SHALL BE PLACED IN 12 INCH LOOSE LIFTS WHEN UTILIZING HEAVY COMPACTION EQUIPMENT OR 6 INCH LOOSE LIFTS WHEN UTILIZING HAND OPERATED TAMPERS. 4.2 PIPE DETECTION AND IDENTIFICATION A. UTILIZING WARNING TAPE: ALL ELECTRIC SERVICE TRENCHES SHALL BE MARKED WITH WARNING TAPE. 4.3 TRENCH EXCAVATION A. DIG TRENCH TO LINES AND GRADES SHOWN ON THE PLANS OR AS DIRECTED BY CONSTRUCTION MANAGER. B. TRENCH LENGTH SHALL BE SUFFICIENT TO ALLOW FOR SATISFACTORY CONSTRUCTION AND INSPECTION OF THE PROJECT WITHOUT ENDANGERING OTHER CONSTRUCTION WORK OR ADJACENT FACILITIES. 100 \\JWat.cxt AT&T MOBILITY 1801 VALLEY VIEW LANE FARMERS BRANCH, TX 75234 CONSULTANT: \•: d man Networks 6400 INTERNATIONAL PARKWAY SUITE 1000 PLANO, TX 75093 Tel: (972) 406.9692 SITE NAME: SITE ADDRESS: 301 GEORGE BUSH DRIVE COLLEGE STATION, TX 77840 BRAZOS COUNTY 11/15/2013 a S ,u v. • `.j`•. •. o. r4 j1�`�v "t Al: ­**ANTHONY. L. HUEBEL ..........................:.... o p 102126 ��: av /0N::�`�� GATES AND ACCESSORIES INCLUDING TABLE 11. BREAKING THE LEVELING SURFACE. DO NOT OVER VIBRATE AS THIS MAY 2. STRENGTH REQUIREMENTS FOR POSTS AND RAILS CONFORMING TO ASTM CAUSE SEGREGATION. F 669. F. FINISHING EXPOSED CONCRETE SURFACES: 3. TYPE 1 PIPE HOT -DIPPED GALVANIZED STEEL PIPE CONFORMING TO RS 1. THESE PROVISIONS APPLY TO ALL EXPOSED AND ALL FORMED APPROVED BY: ASTM F 1083. PLANE ENDS, STANDARD WEIGHT (SCHEDULE 40) WITH CONCRETE, EXTERIOR OR INTERIOR. UNLESS SPECIFICALLY DETAILED 10/16/13 NOT LESS THAN 18 OZ. ZINC PER SQ. FT. OF SURFACE AREA COATED. REVISION OTHERWISE, PERFORM PROCEDURES PRIOR TO APPLICATION OF 4. FILLINGS: COMPLY WITH ASTM F 526 MILL FINISHED ALUMINUM OR ANY CURING COMPOUNDS. GALVANIZED IRON STEEL TO COMPLY WITH MANUFACTURER'S 2. ALL SURFACES: THOROUGHLY CLEAN OFF ALL STAINS, SPATTER REQUIREMENTS. AND LOOSE MATERIAL. 5. TOP RAIL MANUFACTURERS LONGEST LENGTHS, WITH EXPANSION TYPE 3. FINS, RIDGES AND HIGH SPOTS: HONE SMOOTH WITH ABRASIVE COUPLINGS, APPROXIMATELY 6 INCHES LONG FOR EACH JOINT. , POWER GRINDERS WHILE CONCRETE IS GREEN, IMMEDIATELY AFTER PROVIDE MEANS FOR ATTACHING TOP RAIL SECURELY TO EACH GATE FORM REMOVAL. CORNER, PULL AND END POST. 4. FORM TIE HOLES AND DEEP DEPRESSIONS: FLUSH THOROUGHLY D. GALVANIZED STEEL 11/4 INCH NPS (1.66 INCH OD) TYPE I OR II STEEL WITH CLEAN WATER AND TAMP TO OVERFULL WITH DRYPACK. CURE PIPE OR 1.625 INCH x 1.25 INCH ROLL -FORMED C SECTIONS WEIGHING 10 DAYS AND HONE FLUSH AND SMOOTH. 1.35 LBS. PER FT. 5. ROCK POCKETS, HONEYCOMB, SAND STREAKS, DEBRIS AND VOIDS: E. SWING GATES: CUT OUT AT LEAST 1 INCH DEEP WITH SIDES PERPENDICULAR TO COMPLY WITH ASTM F 9000. PROVIDE HARDWARE AND ACCESSORIES FOR SURFACE. FLUSH THOROUGHLY WITH CLEAN WATER, COAT SURFACE EACH GATE. GALVANIZED PER ASTM A 153, AND IN ACCORDANCE WITH THE WITH NEAT CEMENT PASTE AND TAMP TO OVERFULL WITH DRYPACK FOLLOWING: IN AT LEAST TWO LAYERS. CURE FOR 10 DAYS AND HONE 1. HINGES: NON LIFT- OFF TYPE. OFFSET TO PERMIT ISO DEG. GATE FLUSHED AND SMOOTH. OPENING. G. CONTRACTOR SHALL VERIFY ALL SIZES AND LOCATIONS OF ALL 2. LATCH: MTS MULTI -LOCKING DEVICE MT -C6477 OR APPROVED EQUAL. ELECTRICAL OPENINGS AND EQUIPMENT/BUILDING PADS WITH THE 3. KEEPER: PROVIDE KEEPER FOR VEHICLE GATES, WHICH AUTOMATICALLY ELECTRICAL DRAWINGS AND SHOP DRAWINGS. IT SHALL BE THE ENGAGES GATE LEAF AND HOLDS IT IN OPEN POSITION UNTIL MANUALLY RESPONSIBILITY OF THE CONTRACTOR TO PROVIDE ALL OPENINGS AND RELEASED. SLEEVES FOR PROPER DISTRIBUTION FOR ALL UTILITIES. CONTRACTOR F. CONCRETE: SHALL REFER TO DRAWINGS OF OTHER TRADES AND VENDOR DRAWINGS PROVIDE CONCRETE CONSISTING OF PORTLAND CEMENT, ASTM C 150, FOR EMBEDDED ITEMS AND RECESSES NOT SHOWN ON STRUCTURAL AGGREGATES ASTM C 33, AND CLEAN WATER. MIX MATERIALS TO OBTAIN DRAWINGS. PRIOR TO POURING CONCRETE THE INDEPENDENT TESTING CONCRETE WITH A MINIMUM OF 28 -DAY COMPRESSIVE STRENGTH OF 3000 AGENCY SHALL INSPECT ALL FOUNDATION STEEL AND FOUNDATION PSI. SUBGRADE. 6.0 LANDSCAPING 10.0 STRUCTURAL STEEL A. FURNISH, INSTALL AND MAINTAIN LANDSCAPE WORK AS SHOWN AND OR REQUIRED WITHIN THE CONSTRUCTION DOCUMENTS OR AS SPECIFIED IN THE MEET OR EXCEED MANUFACTURER'S RECOMMENDATIONS. AT&T WIRELESS CONSTRUCTION SPECIFICATIONS. A. UNLESS OTHERWISE NOTED, ALL DETAILING, FABRICATION AND PLACING OF 7.0 CONCRETE FORMWORK REINFORCING STEEL SHALL CONFORM TO THE MANUAL OF STANDARD A. FORMS: SMOOTH AND FREE OF SURFACE IRREGULARITIES. UTILIZE FORM PRACTICE FOR DETAILING REINFORCED CONCRETE STRUCTURES (ACI 315). RELEASE AGENTS. B. ALL REINFORCING STEEL SHALL BE NEW BILLET STEEL, CONFORMING TO B. CHAMFER: EXPOSED EDGES OF ALL TOWER FOUNDATIONS SHALL RECEIVE A ASTM A-615, GRADE 60, DEFORMED. 3/4" BY 3/4" 45 DEGREE CHAMFER. OTHER EXPOSED EDGES SHALL C. HEATING AND WELDING OF BARS IS PROHIBITED WITH THE EXCEPTION OF RECEIVE A TOOLED RADIUS FINISH. WRITTEN APPROVAL BY THE STRUCTURAL ENGINEER. 100 \\JWat.cxt AT&T MOBILITY 1801 VALLEY VIEW LANE FARMERS BRANCH, TX 75234 CONSULTANT: \•: d man Networks 6400 INTERNATIONAL PARKWAY SUITE 1000 PLANO, TX 75093 Tel: (972) 406.9692 SITE NAME: SITE ADDRESS: 301 GEORGE BUSH DRIVE COLLEGE STATION, TX 77840 BRAZOS COUNTY 11/15/2013 a S ,u v. • `.j`•. •. o. r4 j1�`�v "t Al: ­**ANTHONY. L. HUEBEL ..........................:.... o p 102126 ��: av /0N::�`�� NO I DESCRIPTION BY I DATE 0 ISSUED FOR CONSTRUCTION RS 10/22/13 1 REVISED PER RFDS TH 10/31/13 [:2:REVISED PER COMMENTS WS 11/14/13 SHEET TITLE: GENERAL NOTES SHEEP NUMBER: N1.1 L 5CONSU ,.., .....I,. EER: :'::>:<LT 1 ::::>:':' ENGINEERS, \ \ \ o \ \ NG NG N S, INC. 19315 FM 2252, STE. 301 PH: (210) 542-5911 GARDEN RIDGE, TX 78266 F-13646 DRAWN BY: RS APPROVED BY: TH DATE DRAWN: 10/16/13 REVISION NO I DESCRIPTION BY I DATE 0 ISSUED FOR CONSTRUCTION RS 10/22/13 1 REVISED PER RFDS TH 10/31/13 [:2:REVISED PER COMMENTS WS 11/14/13 SHEET TITLE: GENERAL NOTES SHEEP NUMBER: N1.1 D. ALL REINFORCEMENT BARS TO BE FREE FROM LOOSE RUST AND SCALE. E. UNLESS OTHERWISE NOTED, ALL REINFORCEMENT SHALL HAVE A MINIMUM CONCRETE COVERAGE OF 3 INCHES. THIS MAY REQUIRE SPACERS AND CHAIRS AS REQUIRED Q BY TESTING AGENCY OR CONSTRUCTION MANAGER. F. SPLICES IN REINFORCEMENT STEEL ARE PROHIBITED, UNLESS APPROVED BY CONSTRUCTION MANAGER. ALL SPLICES MUST THEN MEET ALL APPLICABLE ASTM STANDARDS FOR SPLICING. 11.0 GROUNDING MEET ALL APPLICABLE CODES, REQUIREMENTS OF THE CONSTRUCTION DOCUMENTS AND AT&T WIRELESS CONSTRUCTION SPECIFICATIONS. GENERATOR SPECIFICATIONS 1. SWITCHES AND STANDARD FEATURES A. CYCLIC CRANKING B. ALARM HORN WITH SILENCING SWITCH C. VOLTAGE ADJUSTING RHEOSTAT D. OVERVOLTAGE PROTECTION E. REMOTE TWO -WIRE AUTO START SYSTEM F. LAMP TEST SWITCH G. RUN-OFF-RESET/AUTO SWITCH (ENGINE START) H. ENGINE COOL DOWN TIMER (5 MINUTES) 2. ERROR -PROOF WIRING HARNESS FOR ELECTRICAL CONNECTIONS 3. PANEL LAMPS 4. DC CIRCUIT PROTECTION UNIT ACCESSORIES 1. WEATHER HOUSING -STANDARD WITH ROOF MOUNTED SILENCER 2. MOUNTED CRITICAL GRADE EXHAUST SILENCER 3. TAIL PIPE AND RAIN CAP COOLING SYSTEM ACCESSORIES 1. UNIT MOUNTED RADIATOR 2. ENGINE BLOCK HEATER FUEL SYSTEM ACCESSORIES 1. FLEXIBLE FUEL LINES 2. ENGINE BLOCK HEATER 3. SUBBASE FUEL TANK -172 GALLONS 4. DOUBLE WALL CONSTRUCTION WITH LEAK DETECTION MONITOR 5. U.L. 142 LISTED 6. FUEL LEVEL GAUGE 7. LOW FUEL LEVEL ALARM 8. FILL PIPE EXTENDED 10% INTO TANK 9. HIGH -FUEL LEVEL ALARM -SET AT 95% 10. 7.5 GALLON LOCKABLE FILL WITH SPILL CONTAINMENT ANTENNA & COAX NOTES: 1. VERIFY EACH CABLE LENGTH, DIAMETER, ROUTING, COLOR CODING AND ALL APPURTENANCES. 2. THE MAXIMUM COAXIAL CABLE LENGTH AND CORRESPONDING COAXIAL DIAMETER IS SHOWN ON A2.0. THIS CABLE LENGTH IS TO BE USED FOR FABRICATION OR CONSTRUCTION. ACTUAL CABLE LENGTH(S) MUST BE VERIFIED. COAXIAL CABLE SHALL BE PROVIDED BY AT&T. 3. ALL COAX CABLES SHALL UTILIZED GROUND KITS, GROUNDED AS FOLLOWS: A. NEAR ANTENNA RAD CENTER ELEVATION B. MIDDLE OF TOWER (MID -HEIGHT OF ANTENNA), IF CABLE RUN IS OVER 200'-0" C. BOTTOM OF TOWER D. AT MASTER GROUND BAR 3'-0" FROM MMBS-BBU CABINET 4. ALL TOP JUMPERS SHALL BE LENGTHS AS SHOWN AND INSTALLED BY CONTRACTOR. 5. ALL CABLES SHALL BE COLOR CODED AS SHOWN ON SHEET RF1.0 AN IN ACCORDANCE WITH AT&T SPECIFICATIONS. 6. BANDING SHALL BE IN ACCORDANCE WITH SHEET A2.0, RF1-.0 AND AS FOLLOWS: A. MAIN LINE COLOR BANDS SHALL BE 2" WIDE. MAINTAIN 1" SPACING BETWEEN COLORS. B. FREQUENCY COLOR BANDS SHALL BE 2" WIDE WITH NO SPACE BETWEEN COLORS. C. JUMPER COLOR BANDS SHALL BE 1" WIDE WITH 1" SPACE. D. START COLOR BANDS 2" BEYOND WEATHERPROOFING. E. START SELECTOR COLOR NEXT TO END CONNECTORS. 7. FINAL COAXIAL ANTENNA CABLE SIZES SHALL BE DETERMINED BY AT&T RF ENGINEER. SEE ANTENNA SCHEDULE SHEET A2.0. BASE ON FINAL CABLE RUN LENGTHS DETERMINED BY AT&T. 8. SEE CONSTRUCTION MANAGER FOR ANTENNA SUPPORT ASSEMBLY TYPE. 9. ALL COAXIAL CABLE WILL BE SECURED TO THE DESIGNED SUPPORT STRUCTURE AT DISTANCES NOT TO EXCEED 3' OR THE CABLE MANUFACTURES SPECIFICATIONS WHICHEVER IS LESS, WITH HARDWARE SPECIFIED IN THE COAXIAL CABLE ROUTING DETAILS OF THE SUPPLIED STRUCTURAL REPORT BY OTHERS. 10. PROVIDE AT LEAST 6" OF SLACK IN THE MAIN COAXIAL CABLES AT THE ANTENNA MOUNTING ELEVATION TO PROVIDE FOR FUTURE CONNECTOR REPLACEMENT. I MN mon . . . . . . . . at&t AT&T MOBILITY 1801 VALLEY VIEW LANE FARMERS BRANCH, TX 75234 CONSULTANT: "oodmanNetworks 6400 INTERNATIONAL PARKWAY SUITE 1000 PLANO, TX 75093 Tel: (972) 406.9692 SITE NUMBER: HX3572 SITE ADDRESS: 301 GEORGE BUSH DRIVE COLLEGE STATION, TX 77840 BRAZOS COUNTY \CONSU ING' EN�G�I�NEE�RS, �'I.N.C. 19315 FM 2252, STE. 301 PH: (210) 542-5911 GARDEN RIDGE, TX 78266 F-13646 DRAWN BY: RS APPROVED BY: TH DATE DRAWN: 10/16/13 REVISION NO DESCRIPTION BY DATE 0 ISSUED FOR CONSTRUCTION RS 10/22/13 1 REVISED PER RFDS -TH 10/31/13 2 REVISED PER COMMENTS WS 11/14/13 SHEET TITLE: GENERAL NOTES SHEET NUMBER: N1.2 to 8 w - ,.-AV 21" E 6�r (U \ R W _LOa, W X X • Q UJ Q Q Z \ N m EIZ000UO2 3 J p-, Z 1 W Ic W I v> O >, N `v E> M Q}pj vU)YO' o O O 0) Z 1ZWW 1 j WZ F- F - � ZZ30 O U p \ c < 0 .0 o U iae v3 vp V Z W +' 41 M OOi \ !. •p = m 00 N O t_ C4 n. w a 0 z E o O` �Q p� 0+°-, O m vco O 5Zgz O O Q N 0 C L20�p M ��OW Q F1' 0 U- 0 D N c °O �°Opvrn c v c \ � LLIJ caL m i Z c c a v �a< y LOX i X co �zXC a) a e E c 0-0 v - CS y ZZM 0z O a �Zw k �v°(n°o4- o ¢�0 13o E +� y \ o c s a) \ 0 E'Ov' o 0 z ° a aov.oN,o o �v � e U o; \ c LL v+ amain � c,, of 0 EL (n, L 0 v 3 v o o 0wa�a \ ° rn ;r- a) - 0 z z O c n v 0-0 c R W _LOa, W X X • Q UJ Q Q Z T N m EIZ000UO2 3 J p-, Z 1 W Ic W I v> >, N `v E> M Q}pj vU)YO' o O O 0) Z 1ZWW 1 j WZ F- F - � ZZ30 O Q p M J3 itl c < 0 .0 o U iae v3 vp V Z W +' 41 M OOi p !. •p = m 00 N O t_ C4 n. w a 0 ° E o O` �Q p� 0+°-, O m vco O 5Zgz O O Q N 0 C L20�p M ��OW Q F1' 0 U- 0 D N c °O �°Opvrn c v c n � LLIJ caL m i Z c c a v �a< y LOX i <)�i' co �zXC a) a e E c 0-0 v - CS y ZZM 0z O I! �Zw k �v°(n°o4- o ¢�0 13o E +� y ❑o❑❑❑ o c s a) L` 0 E'Ov' o o ° a aov.oN,o o �v � e U o; > c v+ amain � c,, of 0 EL (n, L 0 v 3 v o o 0wa�a c 1 ° rn ;r- a) - 0 z z O c n v 0-0 c 4- 0 vco41 w ( c v E c w 0 C C L 3 O °> O ,0 vi s 3 CO 0 V ` �U Ny °'c a) .0 � aW U c o'+c-. oro a°O.ocn c p arc �E 4'0 Oc 06 av v axio rnE 1U) 0 E -c N lul _0 10 x m N -.1 G +y+ C C O41 U0° W -V N M 0 N E cmN 4-> E T° E d� W a, p+'N ON O� d N a) a)a)U) C° 4) v. O� C OO)t c U � Com' 4, -C MN O'~ p c E O cL L- pi\O4- Cr-) c-0 oc �_ EP O N 3 �3 cam° E p O Q T D 0 va *' T O y p °��Z3 moa vE aco ) a) w0. to w°c�nat �y v v = v1 T U N 06 O N U C y= O F li t (0 O C >1 W LO a 0mN 0 0 a°° E-5- m0 °° ° v c v oc LZ° p V) olt.i00 `. U ; to �°opo m° NC =r, .2c N - 0O c o0 > to °o� opt °Oa m U`Y- +c .-�'. °L- c0 00� ` �° noc t v'Oa `)OO O Q) 0 0 ai E E -p o (D ° o p .° H H ,0 Q'O C o0.C�OOO U U EC avvc) o a) o°o :3 °UE t- 1- m / + mw O O 0 X Oo - QZ O to tG vm R W _LOa, W X X • Q UJ Q Q Z o U Z � y` v o E y N . 0,2(j) Off C °rG JjJ O U ELL* c V' Vis% W p kms' t b,£ N m EIZ000UO2 3 J � F Z 1 W Ic W I W9 t d M Q}pj vU)YO' o O O 0) Z 1ZWW 1 j WZ F- F - � ZZ30 O Q ++ p }'S 0 a.p� M J3 itl IIn 5 p 4 < Cc C4 Q Z W �j ,,tLL M t10i M OOi !. W D J— c v o,' w 0 ° —J ° Z O m v �. °~ c 5Zgz O O Q 0 0 m �V)w (_- Ta) ti 7 N U� U- 0 -i In 0 C O > 4) (A x 0 � LLIJ caL m WpZZ �a< y LOX i <)�i' �zXC Q e E Z 0 C 0 F - ZZM 0z W oa�Q� I! �Zw k ¢�0 13o E +� y ❑o❑❑❑ W �I o v E� ° � a of 0 EL (n, 0 v 3 v o ~ 0wa�a O �°, N N a`ro 4- 0 ( n c42 c �� in �U Ny °'c 0 mF 04, �, oM L6 o UG -W0-Oi aW U a U U)F �,dNZ ++ Z wC O In vi a) W CW90 lul x m In -.1 Q zzjzzz N IO .Q 1ZWW 1 j WZ F- F - � ZZ30 O ZZ3 M J3 itl IIn 5 p 4 < Cc C4 Q ttOo N O X V M t10i M OOi W W LL w w 0 ° —J ° Z = 0 N 5Zgz O O Q 0 0 m �V)w U- 0 -i In 0 x 0 � LLIJ caL m WpZZ �a< <)�i' �zXC Q zzzzr) Z ZZM 0z W oa�Q� I! �Zw ¢�0 ❑o❑❑❑ Q zzjzzz IaSUIBz `YiV ZVW:I I £IOZ3,1/I I `-WIAP'•LI9Ma k'JVQNnogxaLXaQ ZLs£XH j !i iw LL U Z = 0 Y i= Q F �V)w -i WpZZ Z Z w W oa�Q� I! �Zw ❑o❑❑❑ W �I o � a of 0 EL (n, 0 Y ~ 0wa�a IaSUIBz `YiV ZVW:I I £IOZ3,1/I I `-WIAP'•LI9Ma k'JVQNnogxaLXaQ ZLs£XH NOTES: 1 - THIS PLAN WAS CREATED WITH THE AID OF A PROFESSIONAL LAND SURVEY BY TOWN & COUNTRY SURVEYORS DATED 10/25/13. 2. AT&T AND VERIZON EQUIPMENT AREAS ARE ON THE GROUND LEVEL. THEY ARE SHOWN IN THE AERIAL VIEW ON THIS SHEET FOR REFERENCE ONLY -4:yl CALLED 106.2 ACRES TO THE 7EXAS A&M UNIVERSITY SYS7EM NO RECORD INFORMA77ON FOUND 0 O 1 A2.0 (3) AT&T RRUS-1 1 & (2) DC2 SURGE SUPPRESSION MOUNTED TO CONCRETE BEAM ON 5th FLOOR OF PARKING GARAGE (TYP. EACH SECTOR) PROPOSED (2) AT&T GAMMACALLED 8.72 ACRES j ANTENNAS STACKED ON COLUMN bc \ TO VCS A SSOCIA 7ES LTU. 00' PROPOSED AT&T METER By SPECIAL WARRANTY DEED VOLUME 2172, PAGE 14 e" AND DISCONNECT N.R-aC. T EXISTING VERIZON 4 METER -------7 .7" EXISTING 0 PROPOSED (2) AT&T 2" CONDUIT FOR ELECTRICAL TRANSFORMER 'All SERVICE. HAND TRENCH AS REQUIRED"' ALPHA TO AVOID EXISTING UTILITIES ANTENNAS EXISTINGPROPOSED (2) 14 AT&T BETA TELCO VAULT—, A?' •ANTENNAS EXISTING VERIZON . ..... STEALTH POLE ry cb EXISTING VERIZON EQUIPMENT AREA LOCATED ON GROUND LEVEL A 15�e PROPOSED ED AT&T (12 —6 x25) LEASE 5 AREA LOCATED ON v C3 kr GROUND LEVEL \\ X00 ���``�X Fss "po EXISTING PARKING GARAGE IN el/ . ......... ✓ I'v c) CALLED 8.72 ACRES TO VCS A SSOCIA TES L 7D. BY SPECIAL WARRANTY DEED VOLUME 2172, PAGE 14 co• N.R.B. C. T 0 CURVE TABLE CURVE RADIUS LENGTH I DELTA I CHD. BRG I'EHD. Cl 75_._00 127.99197*46'47IS78'58,07"Wl113.02 C2 40.00 38.75 155*30-15 5-37-46,'15"E 37.25 eA N6 6 1 OVERALL AREA PLAN 'M V ® FULL SIZE PLOT SCALE: 1 " = 40' TRUE HALF SIZE PLOT SCALE: 1 " = 80' NORTH 0 20' 40' 80' EXISTING BUILDING EXISTING BUILDING BUILDING �Plat�ung R_ RMul"IFIS 7_13111 � erp= I COP PB",!lJ'k,�,�� ,,%'rE­ 1 NOV 2 5 2013 COLT E GE Sl_* - I ENGINEERING PREPARED FOR: J ha S JAN 10 mw\mm 'o t&t ............ AT&T MOBILITY 1801 VALLEY VIEW LANE FARMERS BRANCH, TX 75234 CONSULTANT: SITE NAME: 111 *Awl d :4 :1 SITE NUMBER: HX3572 SITE ADDRESS: 301 GEORGE BUSH DRIVE. COLLEGE STATION, TX 77840 BRAZOS COUNTY 11/15/2013 OFT 1 ANTHONY L. `H*' . U7777 00 oo ............. *0 ......... 00 102126 S TERM: . ......... ONAL L vii: EE L 5 4WW ��� CONSULTING`ENGINEERS, INC. 19315 FM 2252, STE. 301 PH: (210) 542-5911 GARDEN RIDGE, TX 78266 F-13646 DRAWN BY: RS APPROVED BY: TH DATE DRAWN: 10/16/13 7 REVISION o DESCRIPTION BY G ISSUED FOR CONSTRUCTION RS -DATE 10/22/13 o REVISED PER RFDS TH 10/31/13 R_ RMul"IFIS 7_13111 � erp= I COP PB",!lJ'k,�,�� ,,%'rE­ 1 NOV 2 5 2013 COLT E GE Sl_* - I ENGINEERING PREPARED FOR: J ha S JAN 10 mw\mm 'o t&t ............ AT&T MOBILITY 1801 VALLEY VIEW LANE FARMERS BRANCH, TX 75234 CONSULTANT: SITE NAME: 111 *Awl d :4 :1 SITE NUMBER: HX3572 SITE ADDRESS: 301 GEORGE BUSH DRIVE. COLLEGE STATION, TX 77840 BRAZOS COUNTY 11/15/2013 OFT 1 ANTHONY L. `H*' . U7777 00 oo ............. *0 ......... 00 102126 S TERM: . ......... ONAL L vii: EE L 5 4WW ��� CONSULTING`ENGINEERS, INC. 19315 FM 2252, STE. 301 PH: (210) 542-5911 GARDEN RIDGE, TX 78266 F-13646 DRAWN BY: RS APPROVED BY: TH DATE DRAWN: 10/16/13 7 REVISION NO DESCRIPTION BY 0 ISSUED FOR CONSTRUCTION RS -DATE 10/22/13 1 REVISED PER RFDS TH 10/31/13 2 REVISED PER COMMENTS IWS 11/14/13 f.J 00- R_ RMul"IFIS 7_13111 � erp= I COP PB",!lJ'k,�,�� ,,%'rE­ 1 NOV 2 5 2013 COLT E GE Sl_* - I ENGINEERING PREPARED FOR: J ha S JAN 10 mw\mm 'o t&t ............ AT&T MOBILITY 1801 VALLEY VIEW LANE FARMERS BRANCH, TX 75234 CONSULTANT: SITE NAME: 111 *Awl d :4 :1 SITE NUMBER: HX3572 SITE ADDRESS: 301 GEORGE BUSH DRIVE. COLLEGE STATION, TX 77840 BRAZOS COUNTY 11/15/2013 OFT 1 ANTHONY L. `H*' . U7777 00 oo ............. *0 ......... 00 102126 S TERM: . ......... ONAL L vii: EE L 5 4WW ��� CONSULTING`ENGINEERS, INC. 19315 FM 2252, STE. 301 PH: (210) 542-5911 GARDEN RIDGE, TX 78266 F-13646 DRAWN BY: RS APPROVED BY: TH DATE DRAWN: 10/16/13 REVISION NO DESCRIPTION BY 0 ISSUED FOR CONSTRUCTION RS -DATE 10/22/13 1 REVISED PER RFDS TH 10/31/13 2 REVISED PER COMMENTS IWS 11/14/13 SHEET TITLE: O OVEI-xl-%A LL AREA PLAN SHEET NUMBER: AOmO TRUE NORTH rim= FULL SIZE PLOT SCALE: 3/811 19-01$ HALF SIZE PLOT SCALE: 3/16pp = 13-0)l --mmmmomi 0 21 4' 8) L-A],-) I 11'4kJ Vf 1-\1Z-U1N CABLE TRAY x W, at&t . . . . . . . . . ..... AT&T MOBILITY 1801 VALLEY VIEW LANE FARMERS BRANCH, TX 75234 CONSULTANT: Good man Networks 6400 INTERNATIONAL PARKWAY SUITE 1000 PLANO, TX 75093 Tel: (972) 406.9692 SITE NAME: SITE ADDRESS: 301 GEORGE BUSH DRIVE COLLEGE STATION, TX 77840 BRAZOS COUNTY 11/15/2013 F 7z-11, e 'N A" goo ... ........ 4 op ANTHONY L. HUEBEL 00 ............... ......... I 0". 102126 S10... NAL ,L��\\ 1"E'VE L 5 CONSULTING ENGINEERS, INC. 19315 IM 2252, STE. 301 PH: (210) 542-5911 GARDEN RIDGE, TX 78266 F-13646 DRAWN BY: RS APPROVED BY: TH DATE DRAWN: 10/16/13 REVISION NO DESCRIPTION BY DATE 0 ISSUED FOR CONSTRUCTION RS 10/22/13 1 REVISED PER RFDS TH 10/31/13 2 REVISED PER COMMENTS WS 11/14/13 SHEET TITLE: EXISTING SHEET NUMBER: Al 00 AT&T MOBILITY 1801 VALLEY VIEW LANE FARMERS BRANCH, TX 75234 CONSULTANT: GoodmanNetworks 6400 INTERNATIONAL PARKWAY SUITE 1000 PLANO, TX 75093 Tel: (972) 406.9692 SITE NAME: SITE NUMBER: HX3572 SITE ADDRESS: 301 GEORGE BUSH DRIVE COLLEGE STATION, TX 77840 BRAZOS COUNTY 11/15/2013 OF -1 6, ..............•r ...... oo ANTHONY L. HUEBEL / 102126 0:: �� / S TER• CABLE TRAY %') 1 PROPOSED COMPOUND PLAN TRUE FULL SIZE PLOT SCALE: 3/8" = 1'-0" NORTH HALF SIZE PLOT SCALE: 3/16" = 1'-0" 0 2' 4 8, x °3 Nov 2 2 2013 CULLCUL 6 1 m i ION DEVELOPMENT SERr PLAT FILED: l o%oPlanning File Copy NO DESCRIPTION BY DATE 0 ISSUED FOR CONSTRUCTION RS 10/22/13 1 REVISED PER RFDS TH 10/31/13 2 REVISED PER COMMENTS WS 11/14/13 SHEET TITLE: SHEET NUMBER: A 1.1 t Am& &t ................. AT&T MOBILITY 1801 VALLEY VIEW LANE FARMERS BRANCH, TX 75234 CONSULTANT: Goodman Networks 6400 INTERNATIONAL PARKWAY SUITE 1000 PLANO, TX 75093 Tel: (972) 406.9692 SITE NAME: Ld* v SITE NUMBER: HX3572 SITE ADDRESS: 301 GEORGE BUSH DRIVE COLLEGE STATION, TX 77840 BRAZOS COUNTY 11/15/2013 OF rFJ .......... 00 ANTHONYL HUEBEL 00 .......................... 00 0 2 12 6 00 S T /ONAL 4 b; -I "' ""' L-Wu1r-1v1c:1Nl I rLAIN TRUE FULL SIZE PLOT SCALE: 3/4" = 1'-0" NORTH HALF SIZE PLOT SCALE: 3/8" — 1'-0" T! ----------------------- i 0 3$ 61 DRAWN BY: RS APPROVED 0 T ,PPROVED BY: TH DATE W 1 0/1 P,ATE DRAWN: 10/16/13 REVISION 0 DESCRIPTION — BY DATE ISSUED FOR CONSTRUCTION RS 10/22/13 REVISED PER RFDS TH REVISED I'- 10/31/13 REVISED PER COMMENTS WS 11/14/13 EET TITLE: ENLARGED EQUIPMENT PLAN EET NUMBER: Al m2 NOTE: STRUCTURAL ANALYSIS PERFORMED BY OTHERS. CONTRACTOR TO THOROUGHLY REVIEW AND ADHERE TO THE STRUCTURAL ANALYSIS SPECIFIC TO THIS PROJECT. REFER TO THE ANALYSIS FOR STRUCTURAL INFORMATION INCLUDING BUT NOT LIMITED TO STRUCTURAL UPGRADES, MOUNTING TYPES, ANTENNA DETAILS AND HEIGHTS, CABLE ROUTING, ETC. ANY DISCREPANCY BETWEEN THE DRAWINGS AND STRUCTURAL ANALYSIS, AND/OR TOWER PLANS SHOULD BE BROUGHT TO THE ATTENTION OF THE PROJECT MANAGER PRIOR TO BIDDING AND INSTALLATION. EXISTING VERIZON ANTENNA CANISTER EXISTING LIGHT POST TOP OF EXISTING BUILDING ELEV. 54'-6" AGL RAD CENTER OF AT&T ANTENNAS ELEV. 51 —6 AGL ALPHA & BET, PROPOSED AT&T PANEL ANTENNAS (2 PER SECTOR, 3 SECTORS, 6 TOTAL) PROPOSED AT&T VERTICAL CABLE TRAY. ALTERNATIVELY PROVIDE (2) 3" CONDUITS. PAINT ALL TO MATCH BUILDING FINISH GRADE ELEV. 0'-0" REF. ANTENNA CABLE NOTES : 1. ALL FIBER AND DC CABLES SHALL BE SECURED USING ROSENBERGER GROMMETS. COORDINATE WITH CM FOR APPROVED SNAP—IN OR CLAMP HANGERS. 2. FOR NEW COAXIAL CABLE INSTALLATIONS, THE ANTENNA COAXIAL CABLE INSTALLER SHALL BE RESPONSIBLE FOR PERFORMING AND SUPPLYING AT&T WITH TYPEWRITTEN SWEEP TESTS (ANTENNA RETURN/LOSS TEST). THIS TEST SHALL BE PERFORMED TO THE SPECIFICATIONS AND >PARAMETERS OUTLINED BY THE AT&T RADIO FREQUENCY (RF) ENGINEER. THIS TEST SHALL BE PERFORMED PRIOR TO FINAL ACCEPTANCE OF THE SITE. 3. THE COAXIAL ANTENNA CABLE INSTALLER SHALL BE RESPONSIBLE FOR PERFORMING AND SUPPLYING AT&T WITH 3 TYPEWRITTEN, TIME DOMAIN REFLECTOMETER (TDR) TESTS TO VERIFY CABLE LENGTH AND TO CHECK FOR WATER DAMAGE. 4. VAPOR WRAP WILL BE USED TO SEAL ALL CONNECTIONS. 5. ALL JUMPERS TO THE ANTENNAS FROM THE MAIN TRANSMISSION LINE WILL BE 1/2" JUMPERS AND SHALL NOT EXCEED 6'-0". MAXIMUM LENGTH FOR THE JUMPERS AT BTS UNITS WILL BE 6'-0". 6. UPON COMPLETION, PROVIDE A HEIGHT VERIFICATION DEPICTING RAD CENTER AND TOP OF ANTENNA. NOTE: 1. PAINT ALL VISIBLE ANTENNAS AND APPURTENANCES TO MATCH THE EXISTING BUILDING. 2. ALL EXPOSED CONDUIT SHALL BE PAINTED TO BE IDENTICAL TO OR CLOSELY COMPATIBLE WITH THE COLOR OF BEAM. PROPOSED AT&T CABLE PATHWAY SECURED TO 5TH LEVEL BEAM/ CEILING ANTENNA MOUNTING NOTES: 1. ALL AZIMUTHS ARE TO BE ESTABLISHED CLOCKWISE FROM THE TRUE NORTH HEADING. 2. CONTRACTOR SHALL VERIFY PROPOSED ANTENNA RAD CENTER AND ORIENTATIONS WITH AT&T PRIOR TO INSTALLATION OF ANTENNAS. 3. PRIOR TO ATTACHING ANTENNAS AND MOUNTING SECTIONS, EXISTING TOWER AND TOWER FOUNDATION MUST BE ANALYZED BY A LICENSED STRUCTURAL ENGINEER TO VERIFY TOWER IS CAPABLE OF SUPPORTING THE PROPOSED LOADS. REFER TO STRUCTURAL ANALYSIS BY OTHERS. 4. CONTRACTOR SHALL REFER TO TOWER STRUCTURAL CALCULATIONS FOR ADDITIONAL LOADS. NO ERECTION (WHERE APPLICABLE) OR MODIFICATION OF TOWER SHALL BE MADE WITHOUT APPROVAL OF STRUCTURAL ENGINEER. 5. DESIGN AND CONSTRUCTION OF ANTENNA SUPPORTS SHALL CONFORM TO CURRENT ANSI/TIA/EIA-222—F OR APPLICABLE LOCAL CODES. 6. ALL STEEL MATERIALS SHALL BE GALVANIZED AFTER FABRICATION IN ACCORDANCE WITH ASTM A123, UNLESS NOTED OTHERWISE. 7. ALL BOLTS, ANCHORS AND MISCELLANEOUS HARDWARE SHALL BE GALVANIZED IN ACCORDANCE WITH ASTM A153 UNLESS NOTED OTHERWISE. 8. DAMAGED GALVANIZED SURFACES SHALL BE REPAIRED BY COLD GALVANIZING IN ACCORDANCE WITH ASTM A780. 9. ALL ANTENNA MOUNTS SHALL BE INSTALLED PER MANUFACTURER SPECIFICATIONS. 10. MINIMUM HORIZONTAL SPACING SHALL BE 3'-0" BETWEEN ANTENNAS. PROPOSED BUILDING ELEVATION FULL SIZE PLOT SCALE: 1/8" HALF SIZE PLOT SCALE: 1/16" 0 4' 8' 16' PROPOSED AT&T (3) RRUS-11 & (2) DC -2 SURGE SUPPRESSION UNIT MOUNTED TO CONCRETE BEAM ON 5th FLOOR OF PARAGE GARAGE (TYP. EACH SECTOR) RAD CENTER OF AT&T ANTEN SO\ .00 g ... ... at&t . . . . . . . . . . AT&T MOBILITY 1801 VALLEY VIEW LANE FARMERS BRANCH, TX 75234 CONSULTANT: I Goodman Networks 6400 INTERNATIONAL PARKWAY SUITE 1000 PLANO, TX 75093 Tel: (972) 406.9692 SITE NAME: LLQ SITE NUMBER: HX3572 SITE ADDRESS: 301 GEORGE BUSH DRIVE COLLEGE STATION, TX 77840 BRAZOS COUNTY 11/15/2013 PSE OF iF I 1 '' ��yrl a J+. ANTHONY L. HIJEBEL •% oo ............................... / ,00,o l02126Q�: AL NO DESCRIPTION BY DATE ......... 0 ISSUED FOR CONSTRUCTION RS 10/22/13 1 REVISED PER RFDS TH 10/31 / 13 2 REVISED PER COMMENTS WS 1 1/14/13 ip. • r't c�t � � y S �r _... 4 NOV 2 2 142013 TANA rft'j Planning f u SHEET TITLE: SHEET NUMBER: A2mO NOTE: GAMMA SECTOR ANTENNAS MUST BE ORIENTED TO COVER THE GEORGE BUSH DR. CORRIDOR AND MINIMIZE COVERAGE OF OLSON FIELD. UMTS F\ C-1-1 LTE F\ C-5 (BELOW) DROPOSED AT&T PANEL \ \ ANTENNA (2 PER' SECTOR, 3 SECTORS, 6 TOTAL) PROPOSED AT&T RRUS-11 MOUNTED'70 CONCRETE BEAM (3 PER SECTOR, 3 -.�. SECTORS, 9 TOTAL ' ; ^j \ 0 \ h ,S G.............. PROPOSED AT&T DC2 SURGE '~ SUPPRESSION UNIT MOUNTED TO CONCRETE BEAM (2 PER \ \ ............ SECTOR, 3 SECTORS, 6 TOTAL) PROPOSED 18" COVERED CABLE TRAY SECURED TO SIDE OF EXISTING GARAGE BEAM. PAINT \ EXPOSED SECTION TO MATrH \ PROPOSED ANTENNA PLAID 1 „ „ FULL SIZE PLOT SCALE. 1 /4 = 1 -0 TRUE NORTH HALF SIZE PLOT SCALE: 1/8" = 1'-0" 0 2 4' 8' SIDE MANUFACTURER: COMMSCOPE MODEL: SBNH-1 D6565B WEIGHT W/O MOUNTING HARDWARE: 47.4 LBS DIMENSIONS: HxWxD: 72.7"x11.85"x7.1" FREQUENCY: REFER TO RF DATA SHEET 3 SBNH-1 D6565B DETAIL SCALE: N.T.S. PROPOSED AT&T FC 12-PC6-10E MOUNTED TO CONCRETE BEAM UMTS A-1 LTE A-5 - SECTOR 8O• PROPOSED 18" COVERED CABLE TRAY SECURED TO SIDE OF EXISTING GARAGE BEAM. PAINT EXPOSED SECTION TO MATCH BUILDING PROPOSED WALL MOUNT BRACKET (SITEPRO_SP221 OR APPROVED EQUAL) U MTS B-1 - LTE B-5 O� O� j FRONT 4-' SCALE: N.T.S. 4 ANTENNA MOUNT DETAIL SCALE: N.T.S. SIDE •I :• • MANUFACTURER: COMMSCOPE MODEL: SBNH-1 D4545A WEIGHT W/O MOUNTING _ HARDWARE: 39.7 LBS DIMENSIONS: HxWxD: 56.7"x16.2"x7.1" FREQUENCY: REFER TO RF- DATA SHEET D4545B DETAIL RRUS-11 -DIMENSIONS (H x W x D): 17.8" x 17.0" x 7.2" (INCLUDES SUNSHIELD) -WEIGHT: 55 LBS -CLIMATE: -40 *C C TO +55. C (SELF CONVECTION SILENT, NO FANS, IP55) -POWER CONSUMPTION: 200 WATTS (TYP.) NOTE: RRUS CAN ONLY BE PAINTED ON SOLAR SHIELD. 7>>, ooao��� pQ°�apoR�o.� pp pp p\—+. -ate ppp� p`��GSS dam: p� V SCALE: N.T.S. at&t .......... .......... .......... AT&T MOBILITY 1801 VALLEY VIEW LANE FARMERS BRANCH, TX 75234 CONSULTANT: Networks SITE NUMBER: HX3572 SITE ADDRESS: 301 GEORGE BUSH DRIVE COLLEGE STATION, TX 77840 BRAZOS COUNTY 11/15/201 OF r�lkj 00..� �b`s.ww.........w.:........ / ANTHONY L. HLIEBEL00 OF .............................. ♦ o :• 102126 S CONAL E IN. SHEET TITLE: ANTENNA PLAN AND DETAILS SHEET NUMBER: A2.1 lllbk CONSULTING ENGINEERS, . \\ G.I'NEERS, INC. 19315 FM 2252, STE. 301 PH: (210) 542-5911 GARDEN RIDGE, TX 78266 F-13646 DRAWN BY: RS APPROVED BY: TH DATE DRAWN: 10/16/13 REVISION NO DESCRIPTION BY DATE 0 ISSUED FOR CONSTRUCTION RS 10/22/13 1 REVISED PER RFDS TH 10/31/13 2 REVISED PER COMMENTS WS 11/14/13 SHEET TITLE: ANTENNA PLAN AND DETAILS SHEET NUMBER: A2.1 *REFER TO CURRENT RFDS FOR EXACT ANTENNA INFORMATION (TILTS, AZIUMTHS, MODELS, ETC.) i iilqimiliiil ���l , I SCALE: N.T.S. .. ISN'Tall tol 0 9 -01 EM ot A m at&t ............ AT&T MOBILITY 1801 VALLEY VIEW LANE FARMERS BRANCH, TX 75234 CONSULTANT: GoodmanNetworks 6400 INTERNATIONAL PARKWAY SUITE 1000 PLANO, TX 75093 Tel: (972) 406.9692 SITE NAME: -J 11*A7114: SITE NUMBER: HX3572 SITE ADDRESS: 301 GEORGE BUSH DRIVE COLLEGE STATION, TX 77840 BRAZOS COUNTY 11/15/2013 F I '.0 00... ANTHONYHUEBEL ' 102126 0.00 AV S T c) %%O'NAL \00 'gammWaSN", L I t ELS v CONSULTING ENGINEERS, INC. 19315 FM 2252, STE. 301 PH: (210) 542-5911 GARDEN RIDGE, TX 78266 F-13646 DRAWN BY: RS APPROVED BY: TH DATE DRAWN: 10/16/13 REVISION NO DESCRIPTION BY DATE 0 ISSUED FOR CONSTRUCTION RS 10/22/13 1 REVISED PER RFDS TH 10/31/13 2 REVISED PER COMMENTS WS 11/14/13 SHEET TITLE: ANTENNA CONFIGURATION �,HEET NUMBER: A2m,�3 ANTENNA 700 (LTE) 850 (UMTS) 1900 (UMTS) FEEDER ANTENNA FIBER COLOR AZIMUTH RAID FEEDER TYPE LENGTH (TO ELEC. MECH. ELEC. MECH. ELEC. MECH. NUMBER CODE CENTER FC12) MAKE MODEL DOWNTILT DOWNTILT DOWNTILT DOWNTILT DOWNTILT DOWNTILT A-1 RD/GR COMMSCOPE SBNH-1D6585B 80* 51'-6" FIBER 150'± RD/GR/WH A-5 RD/SL COMMSCOPE SBNH-1D6585B 80* 511-6)2 FIBER 150'± RD/SL/WH B-1 BL/GR COMMSCOPE SBNH-1D6585B 145* 512-6)) FIBER 150'± BL/GR/WH B-5 BL/SL COMMSCOPE SBNH-1D6585B 145* 51'-6" FIBER 150'± BL/SL/WH C-1 GR/GR COMMSCOPE SBNH— 1 D4545A 245* 49'-0" FIBER 150'± GR/GR/WH C-5 GR/SL COMMSCOPE SBNH— 1 D4545A 245* 49;-0" FIBER 150'± GR/SL/WH *REFER TO CURRENT RFDS FOR EXACT ANTENNA INFORMATION (TILTS, AZIUMTHS, MODELS, ETC.) i iilqimiliiil ���l , I SCALE: N.T.S. .. ISN'Tall tol 0 9 -01 EM ot A m at&t ............ AT&T MOBILITY 1801 VALLEY VIEW LANE FARMERS BRANCH, TX 75234 CONSULTANT: GoodmanNetworks 6400 INTERNATIONAL PARKWAY SUITE 1000 PLANO, TX 75093 Tel: (972) 406.9692 SITE NAME: -J 11*A7114: SITE NUMBER: HX3572 SITE ADDRESS: 301 GEORGE BUSH DRIVE COLLEGE STATION, TX 77840 BRAZOS COUNTY 11/15/2013 F I '.0 00... ANTHONYHUEBEL ' 102126 0.00 AV S T c) %%O'NAL \00 'gammWaSN", L I t ELS v CONSULTING ENGINEERS, INC. 19315 FM 2252, STE. 301 PH: (210) 542-5911 GARDEN RIDGE, TX 78266 F-13646 DRAWN BY: RS APPROVED BY: TH DATE DRAWN: 10/16/13 REVISION NO DESCRIPTION BY DATE 0 ISSUED FOR CONSTRUCTION RS 10/22/13 1 REVISED PER RFDS TH 10/31/13 2 REVISED PER COMMENTS WS 11/14/13 SHEET TITLE: ANTENNA CONFIGURATION �,HEET NUMBER: A2m,�3 4 TE" gg .§'.i t% ra k N I a nc 1_1 R 4i C. yw, n Ai 1 n Tinree a :nn: PLUMBING DIAGRAM SCALE: N.T.S. 7mlim- �\6 mm a m NO WN a &t AT&T MOBILITY 1801 VALLEY VIEW LANE FARMERS BRANCH, TX 75234 CONSULTANT: "oociffian Networks 6400 INTERNATIONAL PARKWAY SUITE 1000 PLANO, TX 75093 Tel: (972) 406.9692 SITE NAME: FBI *AV* 14 V SITE NUMBER: HX3572 SITE ADDRESS: 301 GEORGE BUSH DRIVE COLLEGE STATION, TX 77840 BRAZOS COUNTY 11/15/2013 OF 4JW054 .....................e...- * t.000 ANTHONY L. HUEBEL 010' 10 212 6 S T 1j%S/ON'A*'L 10'ahL, \' amorrmi", \ \ CONSULTING ENGINEERELS, INC. 19315 FM 2252, STE. 301 PH: (210) 542-5911 GARDEN RIDGE, TX 78266 F-13646 DRAWN BY: IRS APPROVED BY: TH DATE DRAWN: 10/16/13 REVISION NO DESCRIPTION BY DATE 0 ISSUED FOR CONSTRUCTION RS 10/22/13 1 REVISED PER RFDS TH 10/31/13 2 REVISED PER COMMENTS WS 11/14/13 SHEET TITLE: SHEET NUMBER: A3.0 N N vI\vv1vv FRONT VIEW NEW (3) P1000 UNISTRUT (SPACED AS REQUIRED) NEW CIENA MOUNTING BRACKET (AS REQUIRED) 3911 d- UAM C6 FIBER OUT MANUFACTURER: CIENA MODEL: 3911 W/ UNI ACCESS MODULE (UAM) DIMENSIONS: 27.2" X 16.2" X 6.4" WEIGHT: APPROX. 32.8 LBS .� CIENA DETAIL SCALE: N.T.S. 3/8" HILTI KWIK BOLT 3 W/ ?-1 /4" FNARFnNAFNIT EXISTING WALL/BEAM (TYPICAL) )OOT UNISTRUT EDGE ,L P1064 FLAT ;TYP. OF 4) AS FOR SPACING PROPOSED DC2 UNIT UNISTRUT CHANNEL NUT (TYP. OF 4) 2 DC2 MOUNTING DETAIL SCALE: N.T.S. 5 CONDUIT WALL MOUNT DETAIL SCALE: N.T.S. CABLE TRE SPA( DEPTH. WITH CLA H( FASTEI` WIT BOLTS 3/8" HILTI KWIK BOLT 3 W/ 2-1/4" FMRFOMFNT @ 10" O.C. 00.313 (4 Q1 A(`[ Cl c Lc LC; #:I FC12-PC6-10E DETAIL V SCALE: N.T.S. r, CABLE TRAY WALL MOUNT DETAIL 11J SCALE: N.T.S. 6.64?" CABLE TRAY WITH 9" RUNG SPACING, 4" LOADING DEPTH. SUPPORT CABLES WITH STAINLESS STEEL CLAMPS EVERY 6 FT. HOLD DOWN CLAMP FASTENED TO UNISTRUT WITH 3/8" x 2 1/2" BOLTS W/ SPRING NUTS MANUFACTURER: PCTEL MODEL#: GPS—TMG—HR-26NCM DIMENSIONS: 5.0"H x 3.2"D WEIGHT: 0.6 LBS. GALV. ANTENNA MAST PIPE CLAMP SECURED TO POST WITH PIPE TO PIPE CLAMP GPS COAX JUMPER COAX GROUND KIT GPS ANTENNA CABLE TO RECEIVER GPS POLYPHASER MUST BE INSTALLED ON EQUIPMENT SIDE OF SUPPORT STRUCTURE PER THE "SITE PREP GUIDE". S ANTENNA E BRIDGE DST OR SIMILAR DWELD OR COLD ,TER GROUND AMP (T& B ACKBURN 39 4131. EQUIVALENT) 2 AWG GREE ISULATED TRANDED COPPER NEAREST DUND BAR OR JIPMENT GROUND IG 7r AWG GREEN INSULATED STRANDED COPPER i 4 GPS ANTENNA DETAIL SCALE: N.T.S. PREPARED FOR: 00' MOO- at&t AT&T MOBILITY 1801 VALLEY VIEW LANE FARMERS BRANCH, TX 75234 CONSULTANT: ui.-.-ood man Networks 6400 INTERNATIONAL PARKWAY SUITE 1000 PLANO, TX 75093 Tel: (972) 406.9692 SITE NAME: DEXTER SITE NUMBER: HX3572 SITE ADDRESS: 301 GEORGE BUSH DRIVE COLLEGE STATION, TX 77840 BRAZOS COUNTY 11/15/2013 ANTHONY L HUEBEL / a p 102126 0., S T �-O 0 4C'�i.' F II _ II 3/8" THREAD ROD W/ HILTI HIT—HY-150 ADHESIVE W/ MIN. 3" EMBEDMENT @ 4'-0" O.C. j II II Ii NEW UNSTRUT P1000 II II --------------,�- — —————————————————————— — — — I -- NEW CABLE TRAY COVER NEW COVER HOLD DOWN SCREWS @ 12" O.C. -7 CABLE TRAY CEILING MOUNT DETAIL I SCALE: N.T.S. 00 VL:::: \\ �� \��\ CONSULTING ENGINEERS, I'NC. 19315 FM 2252, STE. 301 PH: (210) 542-5911 GARDEN RIDGE, TX 78266 F-13646 DRAWN BY: RS APPROVED BY: TH DATE DRAWN: 10/16/13 REVISION NO DESCRIPTION BY DATE 0 ISSUED FOR CONSTRUCTION RS 10/22/13 1 REVISED PER RFDS TH 10/31/13 2 REVISED PER COMMENTS WS 11/14/13 SHEET TITLE: EQUIPMENT DETAILS SHEET NA40�fF UMBER: P1000 UNISTRUT SPACED AS REQUIRED. SECURE TO STD. UNISTRUT STRUCTURAL PIPE CONNECTOR OR U -BOLTS SIZED PER NEED 4" DIA STD. SCHEDULE STRUCTURAL PIPE (TYP) PROPOSED 12X12X3/4 BASE PLATE W/ (4) 1/2" HILTI KWIK BOLT 3 ANCHORS, MIN. 6" EMBED. 0 I Co � I CD (2) PURCELL CABINET (FLXI6WS), (1) FUTURE-/ EXSITING CONCRETE FLOOR 4'-6" NEW (3) RRUS-11 ATTACHED TO UNISTRUT PER MANUFACTURER'S REQUIREMENTS 2'-1 " NEW (2) UNISTRUT W/ PLASTIC END CAPS, MOUNTED TO EXISTING WALL W/ NEW 1/4" HILTI KWIK BOLT 3 W/ MIN. 2-1/4" EMBEDMENT @ 12" O.C. .� PURCELL MOUNTING DETAIL SCALE: N.T.S. REAR VIEW 'ROPOSED 'PC CABINET 'ROPOSED ;IENA CABINET NEW (2) DC2-PC6-10E SURGE SUPPRESSION UNIT ATTACHED TO UNISTRUT PER MANUFACTURERS REQUIREMENTS WATERTIGHT ENE ( D1000 UNISTRUT SPACED AS REQUIRED. SECURE TO STD. UNISTRUT STRUCTURAL RIPE CONNECTOR OR J -BOLTS SIZED PER NEED 4" DIA STD. SCHEDULE STRUCTURAL PIPE (TYP) DROPOSED 12X12X3/4" SASE PLATE W/ (4) 1/2" -IILTI KWIK BOLT 3 ANCHORS, MIN. 6" EMBED. EXISTING CONCRETE BEAM .................. ----------------- -_-_-_ -_- 0 : NOTE: 1. ROUTE ALL JUMPER CABLES ABOVE OR BEHIND RRU SUCH THAT THEY ARE NOT EXPOSED. 2. PROPERLY DRESS PER MANUFACTURER AND CONSTRUCTION MANAGER REQUIREMENTS 2 RRUS-11 & DC2 MOUNTING DETAIL SCALE: N.T.S. 4'-0" 0 100A MAINTENANCE DISCONNECT BEFORE TRANSFORMER. FIELD _OCATE D1000 UNISTRUT SPACED AS REQUIRED. SECURE TO STD. UNISTRUT STRUCTURAL RIPE CONNECTOR OR J -BOLTS SIZED PER NEED 4" DIA STD. SCHEDULE STRUCTURAL PIPE (TYP) o"Fat&t. . . . . . . . . . . . .. . . . . . . . . . . . AT&T MOBILITY 1801 VALLEY VIEW LANE FARMERS BRANCH, TX 75234 CONSULTANT: SITE NUMBER: HX3572 SITE ADDRESS: 301 GEORGE BUSH DRIVE COLLEGE STATION, TX 77840 BRAZOS COUNTY 11/15/2011 i. u. 00 ANTHONY L. HUEBEL �... :.....................:....i ;� p 102126 ��,••�� //i ��;•.;�c/ STAR,; •'��"� 0NXAL \\ :::.: 0 \ \ CONSULTING ENGINEERS, INC. addis 19315 FM 2252, STE. 301 PH: (210) 542-5911 GARDEN RIDGE, TX 78266 F-13646 DRAWN BY: RS APPROVED BY: TH DATE DRAWN: 10/16/13 REVISION NO DESCRIPTION BY DATE 0 ISSUED FOR CONSTRUCTION RS 10/22/13 1 REVISED PER RFDS TH 10/31/13 2 REVISED PER COMMENTS WS 11/14/13 SHEET TITLE: EQUIPMENT DETAILS 3 UTILITY H -FRAME MOUNTING DETAIL I SHEET NUMBER: A401SCALE: N.T.S. .9 m an 1 1-1 "1 N I \_.' Ll L__ I f-\ I L_ NOTES: 1. ABOVE INFORMATION SHOWN FOR REFERENCE ONLY. ACTUAL ENGINEERING OF FENCE SYSTEM SHALL BE COORDINATED WITH FENCE MANUFACTURER, CONTRACTOR AND VENDOR. 2. ALL FENCE POSTS TO BE HOT—DIPPED GALVANIZED UNO 3. DRILLED PIER FOOTING CONCRETE, Vc OF 3000 PSI MIN 4. BRACING RODS TO BE TENSIONED PER INDUSTRY STANDARDS. 5. CONTRACTOR SHALL USE GALVANIZED SCREWS TO ATTACH PICKETS TO BACK RAILS MIN. 2 PER PICKET. 1 TYPICAL WOODEN FENCE ' SCALE: N.T.S. T FYP.) RAIL PICKETS 1 N4" r- A r) DOG WATERTI( ENDCAP (I 2x4 BACK F (T\ STEEL P( ADAPTER (T\ 3" STD. (SCH 40) F 1/2" 13/ PLATE, REI TO D El FINISF GR/ PICKET MULTIPLIER TABLE PICKET DIMENSION SIDE BY SIDE OVERLAP/ BOARD ON BOARD 1 x4 (3-1/2") 3.3 4.8 1x4 FULL 4" 3 4 1 x6 (5-1/2") 2.2 2.9 1x6 FULL 6" 2 2.45 q PICKET TABLES W SCALE: N.T.S. SPACE PICKETS TABLE PICKET DIMENSION 227 SPACE 3)) SPACE 4" SPACE 1 x4 (3-1/2") 2.2 1.9 1.6 1x4 FULL 4" 2 1.75 1.5 1 x6 (5-1/2") 1.6 1.45 1.3 1x6 FULL 6" 1.5 1.35 1.2 r) . . C' /1 A M r -'l /-1 A f ( NOTES: 1 CONTRACTOR SHALL PROVIDE ACCESS HOLES FOR FORGED ZINC COATED CHAIN TO WOODEN ACCESS GATE. 2. CONTRACTOR TO SUPPLY AND INSTALL A 3/8" x 36" FORGED ZINC COATED CHAIN WITH A R DIGIT COMBINATION MASTER LOCK HAVING AN ELONGATED SHANK. SET COMBINATION AS DIRECTED BY CONSTRUCTION MANAGER. TYPICAL WOODEN GATE DETAIL 1 SCALE: N.T.S. No E_E_Nln7 nnc-r GALVANIZED FRAM E FIGHT ENDCAP ROD (TYP.) ). GA. � 0) PIPE \'REL (TYP.) 3ASE REFER FAIL A BASE PLATE DETAIL SCALE: N.T.S. FOR IK lgvvgmvx� • ; Am& x �0 on at&t ... ..... ... . AT&T MOBILITY 1801 VALLEY VIEW LANE FARMERS BRANCH, TX 75234 CONSULTANT: SITE NAME: � Q *.vklk 40-m-44-:11 SITE NUMBER: HX3572 SITE ADDRESS: 301 GEORGE BUSH DRIVE COLLEGE STATION, TX 77840 BRAZOS COUNTY _110obw- 'EVELS CONSULTING ENGINEERS, INC. 19315 FM 2252, STE. 301 PH: (210) 542-5911 GARDEN RIDGE, TX 78266 F-13646 DRAWN BY: RS APPROVED BY: TH DATE DRAWN: 10/16/13 REVISION .NO DESCRIPTION BY DATE 0 ISSUED FOR CONSTRUCTION RS 10/22/13 1 REVISED PER REDS TH 10/31/13 12 REVISED PER COMMENTS WS 11/14/13 SHEET TITLE: FENCE DETAILS SHEET NUMBER: A4m2 BLUE TEXT „�li13:�1 ORANGE BACKGROUN BLUE TEXT 24" \\\♦\\� �♦♦♦\ \ ♦\\ \\\ \ �♦\ \ a\\\ - \ �,\ ��♦ WHITE BACKGROUND WHITE/ORANGE BACKGROUND, BLUE/WHITE LETTERING MOUNTING LOCATION: ALL 4 SIDES OF FENCE (IF AT&T OWNED D SITE; NOT REQUIRED IF OWNED BY OTHERS QUANTITY: 4 PROPERTY OF AT&T 10 SCALE: N.T.S. 1511 �'� \ WHITE ` `� ` BACKGROUND U k7 U L 1 11 \1 \♦\\ \a\ �♦\\\\� p.\\ \ \a\ \ �,\\ ♦a:\\ \ �\\\\ \ gp­\ 1 \ r \\\\\\\� \�\\\\ \ \ \ ,\' \\r-%\\\ \ \ \ \\\\\ \ \ \ ' \ N \\\♦�♦ \: \\\�♦\ \\♦\♦ \ \ \ \\\♦\. 1 L V No o \ \ \ ng 20" \\ \ \� � �\\ \` \ , ORANGE �................... BACKGROUND WHITE/ORANGE BACKGROUND, BLUE/WHITE LETTERING &T ♦ -� `Q♦♦� MOUNTING LOCATION: CABINET DOORS QUANTITY: 1 \ O i� Ii.11: U \y.0♦ \..�� \\\♦\\� �♦♦♦\ \ ♦\\ \\\ \ �♦\ \ a\\\ - \ �,\ ��♦ WHITE BACKGROUND WHITE/ORANGE BACKGROUND, BLUE/WHITE LETTERING MOUNTING LOCATION: ALL 4 SIDES OF FENCE (IF AT&T OWNED D SITE; NOT REQUIRED IF OWNED BY OTHERS QUANTITY: 4 PROPERTY OF AT&T 10 SCALE: N.T.S. 1511 �'� \ WHITE ` `� ` BACKGROUND U k7 U L 1 11 \1 \♦\\ \a\ �♦\\\\� p.\\ \ \a\ \ �,\\ ♦a:\\ \ �\\\\ \ gp­\ 1 \ r \\\\\\\� \�\\\\ \ \ \ ,\' \\r-%\\\ \ \ \ \\\\\ \ \ \ ' \ N \\\♦�♦ \: \\\�♦\ \\♦\♦ \ \ \ \\\♦\. 1 L V No o \ \ \ ng 20" \\ \ \� � �\\ \` \ , ORANGE �................... BACKGROUND WHITE/ORANGE BACKGROUND, BLUE/WHITE LETTERING MOUNTING LOCATION: SHELTER DOOR QUANTITY: 1 MOUNTING LOCATION: CABINET DOORS QUANTITY: 1 PROPERTY O F O AT&T DOOR 7SCALE: LONG LASTING UV RESISTANT COATINGS. N.T.S. 2. AT&T ABOVE GROUND FUEL STORAGE SYSTEMS SIGNS AND LABELING REQUIREMENTS NEPA 704 Hazard Identification System GREEN 15" Diamond —BLACK \\\\\\\\���` TEXT �— RED BRACKETS SHALL BE OF SIMILAR META AS THE \\\\\.� 1 L\\\\�\\\�\ \\\\\\. \\\\\', RED M — WHITE WHITE TEXT • BLUE BACKGROUND WHITE TEXT BLACK TEXT WH ITE BACKGROUND WHITE/BLUE BACKGROUND, WHITE/BLACK LETTERING MOUNTING LOCATION: SHELTER DOOR 8c CABINET DOORS QUANTITY: PER NUMBER OF CABINET DOORS ON SITE AUTHORIZED PERSONNEL SIGN 9 SCALE: N.T.S. BLACK TEXT FIV ACTIVE ANTENNAS ARE MOUNTED ❑ ON THE OUTSIDE OF THIS BUILDING 1 BEHIND THIS PANEL ❑ ON THIS STRUCTURE 12" STAY BACK MINIMUM OF 3 FEET FROM THESE ANTENNAS Contact AT&T Mobility at 800.638.2822 and follow their instructions prior to performing any maintenance or repairs closer than 3 feet from the antennas. This is AT&T Mobility site Sign #2 AT&T Mobility GREEN BACKGROUND 111 601�\\ 11 552\ In 102 vull, 01111.1�1 A 11000 Federal Communications Comm ission Tower Registration Number 7 - Posted in accordance with Federal Communications Commission rules on antenna tower registration 47CFR 17.4(g) 1211 GREEN BACKGROUND SIGNAGE NOTES: 1. SIGNS SHALL BE FABRICATED FROM CORROSION BACKGROUND RESISTANT PRESSED METAL & PAINTED WITH LONG LASTING UV RESISTANT COATINGS. 2. SIGNS (EXCEPT WHERE NOTED OTHERWISE) SHALL BE ,CKGROUN MOUNTED TO THE TOWER, GATE & FENCE USING A MINIMUM OF 9 GAUGE ALUMINUM WIRE, HOG RINGS \\\\\5 —BLACK (FENCE) OR BRACKETS, WHERE NECESSARY. TEXT BRACKETS SHALL BE OF SIMILAR META AS THE RED STRUCTURE TO AVOID GALVANIC CORROSION. — WHITE i BACKGROUND 3. ADDITIONAL E911 ADDRESS & FCC REGISTRATION SIGNS SHALL BE MOUNTED AT EACH ACCESS ROAD GATE LEADING TO THE COMPOUND AS WELL AS ON THE COMPOUND GATE ITSELF. 4. AT&T SITE # & EMERGENCY CONTACT SIGNS SHALL' BE MOUNTED ON THE EQUIPMENT CABINET WITH PERMANENT SET ADHESIVE. TWO SIDED TAPE SHALL BE UTILIZED AT EACH CORNER ON THE BACKSIDE TO WHITE/GREEN BACKGROUND, WHITE/BLACK LETTERING MOUNTING LOCATION: GATE & BASE OF TOWER AID PLACEMENT UNTIL THE ADHESIVE SETS. V QUANTITY: 2 FCC REGISTRATION SIGN 8SCALE: N.T.S. 8$1 BLACK GREEN TEX BACKGROUND WHITE BACKGROUND ` 12 WHITE/GREEN BACKGROUND, BLACK LETTERING MOUNTING LOCATION: GATE & BASE OF TOWER QUANTITY: 2 RF EXPOSURE INFORMATION 6SCALE: N.T.S. CKGROUND WHITE PRODUCT IDENTIFICATION Hazard Ratings: TEXT Nine o'clock -Health p%� Twelve o'clock-FlammabilityNvo,, \ � \\ Lw\\\11011\ \� % Three oclock -Instability\\gip \ .�� \ \\ 1 Six o'clock - Special Signs must be of durable material with red lettering on a white background. REFERENCES: Letters shall not be less than 3 inches (76.2 mm) in height and 1/2 inch (12.7 mm) in stroke. NEPA 704 Signs shall not be obscured or removed and shall be in English as a primary language UFC 7901.9 Combustible Sign may also be white letters on red background. IFC 2703.5 MOUNTING LOCATION: FUEL STORAGE TANK/ GENERATOR QUANTITY: 1 HAZARDOUS MATERIALS 3SCALE: N.T.S. WHITE TEXT 12" AT&T Mobility operates telecommunications antennas at this location. Remain at least 3 feet away from any antenna and obey all posted signs. Contact the owner(s) of the antenna(s) before working closer then 3 feet from the antenna(s) Contact AT&T Mobility at (800)-832-6652 prior to performing any maintenance or repairs near AT&T Mobility antennas This is Site # Contact the management office if this door/hatch/gate is found unlocked. ..::: En esta propiedad se ubican antenas de telecommunicaciones operaadas par AT&T Mobility. Favor mantener una disiancia de no menos de 3 pies y obedecar todos las avisos. Comuniquese can el propietaria o las propiatarios de las antes de trabajar o caminar de menos de 3 pies de la antena Comuni uese can AT&T Mobility 800 832-6652 antes d r aliza q y( ) to e e r cualquier mantenimiento a reparaciones cera de las antenas de AT&T Mobility. Esta es la estacion base numero Favor comunicarse can la oficina de la administracion del adificio si esta puerta o compuerta se encuentra sin canado AT&T Sign #1 Mobility BLACK TEXT WHITE BACKGROUND BLACK TEXT WHITE/GREEN BACKGROUND, BLACK LETTERING MOUNTING LOCATION: GATE & BASE OF TOWER QUANTITY: 2 � RF EXPOSURE INFORMATION SIGN SCALE: N.T.S. BLACKON, 11001WOMEN R Es\00001", IRM011op lk aEH7�, N ID RESPASSING d REOK BFlCK( BACKGROUND BLACK \\\�\ RED TEXT ,\o\� BACKGROUND WHITE/GREEN BACKGROUND, BLACK/WHITE LETTERING MOUNTING LOCATION: ALL 4 SIDES OF FENCE (IF AT&T OWNED SITE) MOUNTING LOCATION: GATE (IF OWNED BY OTHERS) QUANTITY: 1 DANGER TRESPASSING SIGN 2 SCALE: N.T.S. On this tower: Radio frequency fields near some q Y antennas may exceed FCC rules for human exposure. Personnel climbing this tower should be trained for working in radio frequency environments and use a personal RF monitor if working near active antennas. Ref: FCC 47cfr 1.137(b) AT&T Mobility YELLOW BACKGROUN WHITE BACKGROUN YELLOW BACKGROUN WHITE/YELLOW BACKGROUND, BLACK LETTERING MOUNTING LOCATION: BASE OF TOWER QUANTITY: 1 AdOWN OF 0 \ `p \Q\\�`\ IMMMEEMMOW \\ t 11 Q t&tR1000 AT&T MOBILITY 1801 VALLEY VIEW LANE FARMERS BRANCH, TX 75234 CONSULTANT: GoodmanNetworks 6400 INTERNATIONAL PARKWAY SUITE 1000 PLANO, TX 75093 Tel: (972) 406.9692 SITE NAME: DEXTER SITE NUMBER: HX3572 SITE ADDRESS: 301 GEORGE BUSH DRIVE COLLEGE STATION, TX 77840 BRAZOS COUNTY RT EXPOSURE CAUTION SIGNI N401 5 �,�� 4 SCALE: N.T.S. E °\\ 'rhe Authorization for the Radio Equipment At this facility is located at the Control Poing AT&T Mobility 5601 Legacy Drive; MS A-3 Plana, TX 75024 (469)229-7517 office/ (469)229-7295 iX WHITE BACKGROUND, BLACK LETTERING MOUNTING LOCATION: SHELTER DOOR QUANTITY: 1 PER CABINET \�\\\ CONSULTING ENGINEERS, INC. 19315 FM 2252, STE. 301 PH: (210) 542-5911 GARDEN RIDGE, TX 78266 F-13646 DRAWN BY: RS APPROVED BY: TH DATE DRAWN: 10/16/13 WHITE REVISION BACKGROUND NO DESCRIPTION BY DATE 0 ISSUED FOR CONSTRUCTION RS 10/22/13 1 REVISED PER RFDS TH 10/31/13 2 REVISED PER COMMENTS WS 11/14/13 SHEET TITLE: SITE SIGNAGE DETAILS SHEET NUMBER: � 'J BACKGROUND ,CKGROUN \ \\\\\5 \`%64\111\\� 1111 \\\\ \\\\\ Hazard Ratings: TEXT Nine o'clock -Health p%� Twelve o'clock-FlammabilityNvo,, \ � \\ Lw\\\11011\ \� % Three oclock -Instability\\gip \ .�� \ \\ 1 Six o'clock - Special Signs must be of durable material with red lettering on a white background. REFERENCES: Letters shall not be less than 3 inches (76.2 mm) in height and 1/2 inch (12.7 mm) in stroke. NEPA 704 Signs shall not be obscured or removed and shall be in English as a primary language UFC 7901.9 Combustible Sign may also be white letters on red background. IFC 2703.5 MOUNTING LOCATION: FUEL STORAGE TANK/ GENERATOR QUANTITY: 1 HAZARDOUS MATERIALS 3SCALE: N.T.S. WHITE TEXT 12" AT&T Mobility operates telecommunications antennas at this location. Remain at least 3 feet away from any antenna and obey all posted signs. Contact the owner(s) of the antenna(s) before working closer then 3 feet from the antenna(s) Contact AT&T Mobility at (800)-832-6652 prior to performing any maintenance or repairs near AT&T Mobility antennas This is Site # Contact the management office if this door/hatch/gate is found unlocked. ..::: En esta propiedad se ubican antenas de telecommunicaciones operaadas par AT&T Mobility. Favor mantener una disiancia de no menos de 3 pies y obedecar todos las avisos. Comuniquese can el propietaria o las propiatarios de las antes de trabajar o caminar de menos de 3 pies de la antena Comuni uese can AT&T Mobility 800 832-6652 antes d r aliza q y( ) to e e r cualquier mantenimiento a reparaciones cera de las antenas de AT&T Mobility. Esta es la estacion base numero Favor comunicarse can la oficina de la administracion del adificio si esta puerta o compuerta se encuentra sin canado AT&T Sign #1 Mobility BLACK TEXT WHITE BACKGROUND BLACK TEXT WHITE/GREEN BACKGROUND, BLACK LETTERING MOUNTING LOCATION: GATE & BASE OF TOWER QUANTITY: 2 � RF EXPOSURE INFORMATION SIGN SCALE: N.T.S. BLACKON, 11001WOMEN R Es\00001", IRM011op lk aEH7�, N ID RESPASSING d REOK BFlCK( BACKGROUND BLACK \\\�\ RED TEXT ,\o\� BACKGROUND WHITE/GREEN BACKGROUND, BLACK/WHITE LETTERING MOUNTING LOCATION: ALL 4 SIDES OF FENCE (IF AT&T OWNED SITE) MOUNTING LOCATION: GATE (IF OWNED BY OTHERS) QUANTITY: 1 DANGER TRESPASSING SIGN 2 SCALE: N.T.S. On this tower: Radio frequency fields near some q Y antennas may exceed FCC rules for human exposure. Personnel climbing this tower should be trained for working in radio frequency environments and use a personal RF monitor if working near active antennas. Ref: FCC 47cfr 1.137(b) AT&T Mobility YELLOW BACKGROUN WHITE BACKGROUN YELLOW BACKGROUN WHITE/YELLOW BACKGROUND, BLACK LETTERING MOUNTING LOCATION: BASE OF TOWER QUANTITY: 1 AdOWN OF 0 \ `p \Q\\�`\ IMMMEEMMOW \\ t 11 Q t&tR1000 AT&T MOBILITY 1801 VALLEY VIEW LANE FARMERS BRANCH, TX 75234 CONSULTANT: GoodmanNetworks 6400 INTERNATIONAL PARKWAY SUITE 1000 PLANO, TX 75093 Tel: (972) 406.9692 SITE NAME: DEXTER SITE NUMBER: HX3572 SITE ADDRESS: 301 GEORGE BUSH DRIVE COLLEGE STATION, TX 77840 BRAZOS COUNTY RT EXPOSURE CAUTION SIGNI N401 5 �,�� 4 SCALE: N.T.S. E °\\ 'rhe Authorization for the Radio Equipment At this facility is located at the Control Poing AT&T Mobility 5601 Legacy Drive; MS A-3 Plana, TX 75024 (469)229-7517 office/ (469)229-7295 iX WHITE BACKGROUND, BLACK LETTERING MOUNTING LOCATION: SHELTER DOOR QUANTITY: 1 PER CABINET \�\\\ CONSULTING ENGINEERS, INC. 19315 FM 2252, STE. 301 PH: (210) 542-5911 GARDEN RIDGE, TX 78266 F-13646 DRAWN BY: RS APPROVED BY: TH DATE DRAWN: 10/16/13 WHITE REVISION BACKGROUND NO DESCRIPTION BY DATE 0 ISSUED FOR CONSTRUCTION RS 10/22/13 1 REVISED PER RFDS TH 10/31/13 2 REVISED PER COMMENTS WS 11/14/13 SHEET TITLE: SITE SIGNAGE DETAILS SHEET NUMBER: � 'J ,CKGROUN RED Hazard Ratings: TEXT Nine o'clock -Health p%� Twelve o'clock-FlammabilityNvo,, \ � \\ Lw\\\11011\ \� % Three oclock -Instability\\gip \ .�� \ \\ 1 Six o'clock - Special Signs must be of durable material with red lettering on a white background. REFERENCES: Letters shall not be less than 3 inches (76.2 mm) in height and 1/2 inch (12.7 mm) in stroke. NEPA 704 Signs shall not be obscured or removed and shall be in English as a primary language UFC 7901.9 Combustible Sign may also be white letters on red background. IFC 2703.5 MOUNTING LOCATION: FUEL STORAGE TANK/ GENERATOR QUANTITY: 1 HAZARDOUS MATERIALS 3SCALE: N.T.S. WHITE TEXT 12" AT&T Mobility operates telecommunications antennas at this location. Remain at least 3 feet away from any antenna and obey all posted signs. Contact the owner(s) of the antenna(s) before working closer then 3 feet from the antenna(s) Contact AT&T Mobility at (800)-832-6652 prior to performing any maintenance or repairs near AT&T Mobility antennas This is Site # Contact the management office if this door/hatch/gate is found unlocked. ..::: En esta propiedad se ubican antenas de telecommunicaciones operaadas par AT&T Mobility. Favor mantener una disiancia de no menos de 3 pies y obedecar todos las avisos. Comuniquese can el propietaria o las propiatarios de las antes de trabajar o caminar de menos de 3 pies de la antena Comuni uese can AT&T Mobility 800 832-6652 antes d r aliza q y( ) to e e r cualquier mantenimiento a reparaciones cera de las antenas de AT&T Mobility. Esta es la estacion base numero Favor comunicarse can la oficina de la administracion del adificio si esta puerta o compuerta se encuentra sin canado AT&T Sign #1 Mobility BLACK TEXT WHITE BACKGROUND BLACK TEXT WHITE/GREEN BACKGROUND, BLACK LETTERING MOUNTING LOCATION: GATE & BASE OF TOWER QUANTITY: 2 � RF EXPOSURE INFORMATION SIGN SCALE: N.T.S. BLACKON, 11001WOMEN R Es\00001", IRM011op lk aEH7�, N ID RESPASSING d REOK BFlCK( BACKGROUND BLACK \\\�\ RED TEXT ,\o\� BACKGROUND WHITE/GREEN BACKGROUND, BLACK/WHITE LETTERING MOUNTING LOCATION: ALL 4 SIDES OF FENCE (IF AT&T OWNED SITE) MOUNTING LOCATION: GATE (IF OWNED BY OTHERS) QUANTITY: 1 DANGER TRESPASSING SIGN 2 SCALE: N.T.S. On this tower: Radio frequency fields near some q Y antennas may exceed FCC rules for human exposure. Personnel climbing this tower should be trained for working in radio frequency environments and use a personal RF monitor if working near active antennas. Ref: FCC 47cfr 1.137(b) AT&T Mobility YELLOW BACKGROUN WHITE BACKGROUN YELLOW BACKGROUN WHITE/YELLOW BACKGROUND, BLACK LETTERING MOUNTING LOCATION: BASE OF TOWER QUANTITY: 1 AdOWN OF 0 \ `p \Q\\�`\ IMMMEEMMOW \\ t 11 Q t&tR1000 AT&T MOBILITY 1801 VALLEY VIEW LANE FARMERS BRANCH, TX 75234 CONSULTANT: GoodmanNetworks 6400 INTERNATIONAL PARKWAY SUITE 1000 PLANO, TX 75093 Tel: (972) 406.9692 SITE NAME: DEXTER SITE NUMBER: HX3572 SITE ADDRESS: 301 GEORGE BUSH DRIVE COLLEGE STATION, TX 77840 BRAZOS COUNTY RT EXPOSURE CAUTION SIGNI N401 5 �,�� 4 SCALE: N.T.S. E °\\ 'rhe Authorization for the Radio Equipment At this facility is located at the Control Poing AT&T Mobility 5601 Legacy Drive; MS A-3 Plana, TX 75024 (469)229-7517 office/ (469)229-7295 iX WHITE BACKGROUND, BLACK LETTERING MOUNTING LOCATION: SHELTER DOOR QUANTITY: 1 PER CABINET \�\\\ CONSULTING ENGINEERS, INC. 19315 FM 2252, STE. 301 PH: (210) 542-5911 GARDEN RIDGE, TX 78266 F-13646 DRAWN BY: RS APPROVED BY: TH DATE DRAWN: 10/16/13 WHITE REVISION BACKGROUND NO DESCRIPTION BY DATE 0 ISSUED FOR CONSTRUCTION RS 10/22/13 1 REVISED PER RFDS TH 10/31/13 2 REVISED PER COMMENTS WS 11/14/13 SHEET TITLE: SITE SIGNAGE DETAILS SHEET NUMBER: � 'J AT&T SIGNAGE NOTES: 1. FOR BUILDINGS OWNED BY AT&T MOBILITY ALL THE FOLLOWING STANDARDS APPLY. FOR AT&T MOBILITY LEASED SPACE OR, CO—LOCATED FACILITIES, THE ONLY SIGNAGE REQUIREMENTS ARE FOR POINTS OF ENTRY INTO OUR INTERIOR OR EXTERIOR LEASED SPACE. HAZMAT AND RF WARNING SIGN REQUIREMENTS WOULD BE APPLIED AS APPROPRIATE ENTRY POINTS TO AREAS IN THE COLLOCATION WHERE OUR EQUIPMENT IS HOUSED. 2. EXCESSIVE EXTERIOR SIGNAGE ON BUILDINGS CONTAINING NETWORK EQUIPMENT IS PROHIBITED (EXAMPLES INCLUDE, MARQUIS SIGNS, LIGHTED SIGNS OR LARGE PLACARDS). DUE TO THE CRITICAL ELEMENTS HOUSED IN THESE FACILITIES IT IS IN THE BEST INTEREST OF AT&T MOBILITY TO LIMIT UNNECESSARY EXPOSURE TO OUR CRITICAL OPERATING CENTERS. ALTHOUGH THERE SHOULD BE BASIC SIGNAGE ON EXTERIOR BUILDING DOORS AND FENCE AND GATE ACCESS POINTS, IT IS NOT PERMITTED TO USE 'ADVERTISING' TYPE SIGNAGE ON THESE BUILDINGS. 3. GLASS MAIN ENTRY DOORS MAY BE 'BRANDED' WITH AT&T MOBILITY LOGO PROVIDING THIS IS NOT A LIGHTED/ 'MARQUIS' SIGN. IN CERTAIN CASES WHERE A SITE IS UNMANNED, EXTERIOR DOOR SIGNS MAY BE OMITTED TO PREVENT DRAWING UNDUE ATTENTION TO THE SITE. FOR THESE TYPES OF SITES, THE MARKET MAY ELECT TO HARDEN SECURITY I A MORE INVISIBLE MANNER. IT IS THE RESPONSIBILITY OF THE MARKET TO MAKE PRUDENT DECISIONS FOR UNMANNED CORE SITES ON A CASE BY CASE BASIS. 4. BATTERY PLANTS AND FIXED GENERATOR SYSTEMS LOCATED AT A CORE BUILDING WILL CONTAIN DIESEL AND BATTERY ACID AT A LEVEL THAT WOULD TRIGGER HAZMAT SIGNAGE REQUIREMENTS AS DESCRIBED. 5. PLEASE REFER TO RF EXPOSURE SIGNAGE SECTION CONTAINED IN THIS DOCUMENT, AS SOME CORE BUILDINGS MAY TRIGGER CERTAIN SIGNAGE REQUIREMENTS FOR RF EXPOSURE. 6. VENDOR AND PRICING (SECURITY SIGNS) AT&T SIGNAGE NOTES (CONT.): 12. REGIONS/MARKETS ARE TO ORDER THE REQUIRED RF EXPOSURE SIGNS FROM THE VENDOR SPECIFIED BELOW. THIS COMPANY HAS THE LATEST AT&T MOBILITY SIGNS READY TO ORDER. EXCEL SIGN & DECAL 1509 N. MILPITAS BLVD. MILPITAS, CA 95035 WWW.EXCELTEAM.NET 408-942-8881 —ATTN: GRFr, 13. IF THE SITE IS EQUIPPED WITH ENTRY DOOR OR GATE SIGN ASSURE THAT CONTACT # FOR MNRC OF 1-800-638-2822 IS PRESENT. UPDATE CONTACT NUMBER AS NEEDED TO ASSURE APPROPRIATE NUMBER IS PRESENT. IT IS ACCEPTABLE TO USE VINYL TAPE AND PERMANENT MARKER TO COVER OVER OVER OUTDATED NUMBERS WITH NEW NUMBER. 14. IF THE SIGN REFLECTS ANY PAST OWNER (OTHER THEN AT&T), ORDER A REPLACEMENT SIGN. IF THE SITE IS OWNED BY AT&T AND THE REQUIRED DOOR OR GATE SIGN IS MISSING, REPLACEMENT SIGNS MUST BE OBTAINED AND POSTED. SERVICE SELECT INC. BETH OLMSTEAD BETH@SERVICESELECTINC.COM 215-788-3898 GATE SIGN — $16 PER DOOR SIGN — $3.50 PER FENCE/ NO TRESPASSING — EST. $12.50 PER AUTHORIZED PERSONNEL ONLY — EST. $12.50 PER NOTE: SERVICE SELECT INC. IS THE ONLY SIGN COMPANY AUTHORIZED TO PRINT GATE SIGNS AND DOOR SIGNS WITH THE AT&T NAME AND LOGO. 7. NO TRESPASSING SIGNS AND AUTHORIZED PERSONNEL ONLY SIGNS CAN BE PURCHASED FROM A LOCAL HARDWARE STORE. 8. FUEL STORAGE TANKS ARE REQUIRED TO BE MARKED SO THAT THE CONTENTS AND FIRE HAZARDS ARE IDENTIFIED. THE CURRENT LABELS AND PLACARDS FOR ABOVEGROUND TANKS INCLUDE THE FOLLOWING: -PRODUCT LABEL (GASOLINE, DIESEL FUEL) -COMBUSTIBLE LABEL FOR DIESEL FUEL -FLAMMABLE LABEL FOR GASOLINE -NEPA 704 HAZARD ID SYSTEM — 15" DIAMOND PLACARD LABEL (AS REQUIRED BY LOCAL JURISDICTION) -NO SMOKING LABEL -STORAGE TANK CAPACITY LABEL (OPTIONAL) 9. REGIONS/ MARKETS ARE GIVEN THE ABILITY TO CHOOSE WHERE THE SIGNS AND VINYL NUMBER DECALS WILL BE ORDERED. NO VENDOR OR PRICING HAS BEEN ESTABLISHED ON A NATIONAL LEVEL. 10. FOR AT&T—OWNED CELL TOWERS AND OTHER—OWNED TOWERS WHERE AT&T MOBILITY IS PERMITTED TO POST RF SAFETY SIGNAGE. TYPICAL RF EXPOSURE SIGNAGE CONSISTS OF SIGNS REQUIRED TO BE INSTALLED AT ACCESSES TO EACH CLIMBING LADDER AT THE TOWER. " INFORMATION" SIGNS ARE NO LONGER PERMITTED TO BE INSTALLED ON EQUIPMENT CABINETS OR BUILDINGS. 11. SIGNS ME BE SECURED TO TOWERS USING METAL BANDS, ADHESIVE OR SPECIALLY FABRICATED MOUNTING FRAMES. UNDER NO CIRCUMSTANCES ARE HOLES TO BE DRILLED IN , OR BRACKETS WELDED, TO THE TOWER STRUCTURE UNLESS SPECIFICALLY INSTRUCTED OTHERWISE. 1 SITE SIGNAGE NOTES SCALE: N.T.S. ';.a ffiffil at&t AT&T MOBILITY 1801 VALLEY VIEW LANE FARMERS BRANCH, TX 75234 CONSULTANT: Good man Networks 6400 INTERNATIONAL PARKWAY SUITE 1000 PLANO, TX 75093 Tel: (972) 406.9692 SITE NAME: ,ice SITE NUMBER: HX3572 SITE ADDRESS: 301 GEORGE BUSH DRIVE COLLEGE STATION, TX 77840 BRAZOS COUNTY 11/15/2013 PSE of rF%00 �� ANTHONY L. HUEBEL op ..........................:.... o p1021260; .... moo L E ' •CONSULTINGENGINEERS, .INC. 19315 FM 2252, STE. 301 PH: (210) 542-5911 GARDEN RIDGE, TX 78266 F-13646 DRAWN BY: RS APPROVED BY: TH DATE DRAWN: 10/16/13 REVISION NO DESCRIPTION BY DATE 0 ISSUED FOR CONSTRUCTION RS 10/22/13 1 REVISED PER RFDS TH 10/31/13 2 REVISED PER COMMENTS WS 11 /14/13 SHEET TITLE: SITE SIGNAGE NOTES NUMBER:SHEET ELECTRICAL KEYED NOTES: O PROVIDE 2" CONDUIT WITH 2#2 AWG AND 1#6 AWG, CU TYPE THHN/THWN-2 FROM METER. SECURE CONDUIT TO GARAGE CEILING/BEAM. O PROVIDE 2" CONDUIT WITH PULL STRING FOR TELCO SERVICE. COORDINATE WITH CM FOR DEMARC LOCATION. SECURE CONDUIT TO GARAGE CEILING/BEAM. 3\ PROVIDE 1" CONDUIT WITH 1/0 AWG GROUNDING ELECTODE CONDUCTOR. BOND 10' GROUNDING ELECTRODE CONDUCTOR. ® PROVIDE 1" CONDUIT (RMC) WITH 6#10 AWG AND 1#10 AWG GROUND CU TYPE THHN/THWN-2 FOR RECTIFIERS 3-5. O PROVIDE 1" CONDUIT (RMC) WITH 4#10 AWG AND 1#10 AWG GROUND CU TYPE THHN/THWN-2 FOR RECTIFIERS 1-2. O PROVIDE 3/4" CONDUIT (RMC) WITH 4#12 AND 2#12 GROUND FOR HEATER AND GFI. O PROVIDE 2" CONDUIT WITH TRANSFORMER PRIMARY CIRCUIT. \ PROVIDE 2" CONDUIT WITH 3-3/0 AWG AND 1#6 GROUND, CU TYPE THHN/THWN-2 TO PPC. \ PROVIDE 2#6AWG AND 1#10 AWG GROUND FOR EACH PURCELL PDU. SECURE CONDUIT TO GARAGE CEILING 10 PROVIDE (2) 6 CONDUCTOR DC CABLE BUNDLES BETWEEN RAYCAP DC UNIT IN POWER PLANT AND FC12 ON 5TH LEVEL. INSTALL EXPOSED SECTION AT GROUND LEVEL EQUIPMENT IN CONDUIT SECURED TO CEILING. 11 PROVIDE A 24 PAIR PRE-CONNECTORIZED FIBER TRUNK FIBER SPLICE SHELF IN THE PURCELL CABINET TO THE FC12 ON THE 5TH LEVEL. GENERAL NOTES: 1. CONTRACTOR SHALL LOCATE EXISTING UTILITIES PRIOR TO TRENCHING. 2. CONTRACTOR SHALL INSTALL CONDUIT PER CSU SPECS AND DESIGN. 3. METER PEDESTAL WILL BE LOCATED WITHIN 10' OF TRANSFORMER AND WITHIN EASEMENT BOUNDARIES. 4. CSU WILL FURNISH AND INSTALL WIRE FROM TRANSFORMER TO METER PEDESTAL. PROPOSED WOOD FENCE TO MATCH VERIZON'S FENCE PROPOSED AT&T 12'-6"X25' LEASE AREA PROPOSED LTE PURCELL CABINET - PROPOSED UMTS PURCELL CABINET- .... ...... PROPOSED AT&T 4'X6' EQUIPMENT PLATFORM ANDREW MODEL NO. EQ-P6CO406-AL i .............. - — ------ . .. .......................... FUTURE PURCELL CABINET F F F F mi 4 5 6 C E- E Fa Ila T T T DC DC DC DC 11 E E T T T mm �dO.....................` at&t a`�•,`•- AT&T MOBILITY 1801 VALLEY VIEW LANE FARMERS BRANCH, TX 75234 CONSULTANT: SITE NAME: i~ DEXTER 2 SITE NUMBER: 1 W HX3572 E E E- E SITE ADDRESS: 301 GEORGE BUSH DRIVE COLLEGE STATION, TX 77840 BRAZOS COUNTY FUTURE PURCELL CABINET F F F F mi 4 5 6 C E- E Fa Ila T T T DC DC DC DC 11 E E T T T mm �dO.....................` at&t a`�•,`•- AT&T MOBILITY 1801 VALLEY VIEW LANE FARMERS BRANCH, TX 75234 CONSULTANT: SITE NAME: i~ DEXTER 2 SITE NUMBER: 1 W HX3572 E E E- E SITE ADDRESS: 301 GEORGE BUSH DRIVE COLLEGE STATION, TX 77840 BRAZOS COUNTY L T T T T - PROPOSED AT&T UTILITY H -FRAME W/ DISCONNECT, PPC CABINET, AND CIENA 3911 F F F F F F F F F DC DC DC DC DC DC PROPOSED AT&T CABLE TRAY ATTACHED TO EXISTING CEILING OF PARKING GARAGE PROPOSED 6' ACCESS GATE 11/15/2013 i ...............Y ...�.Vf./ ANTHONY L. HUEBEL o,102126 ONAL \\\\\ 0 L I h E L .o000' 0 '04' CONSULTING ENGINEERS, INC. 19315 FM 2252, STE. 301 PH: (210) 542-5911 GARDEN RIDGE, TX 78266 F-13646 DRAWN BY: RS APPROVED BY: TH DATE DRAWN: 10/16/13 REVISION NO DESCRIPTION BY DATE 0 ISSUED FOR CONSTRUCTION RS 10/22/13 1 REVISED PER RFDS TH 10/31/13 2 REVISED PER COMMENTS WS 11/14/13 SHEET TITLE: EXISTING WOODEN FENCE (VERIZON) ELECTRICAL AND ELECTRICAL /TELCO SITE PLAN TELCO PLAN TRUE FULL SIZE PLOT SCALE: 1/2" = 1'-0" HALF SIZE PLOT SCALE: 1/4" = 1'-0" SHEET NUMBER: NORTH El ■ O 0 2' 4' 37.5 KVA 480V PRIMARY 120/240 SECONDARY TRANSFORMER 100A MAINTENANCE DISCONNECT AT EQUIPMENT PLATFORM 2#2 AWG + 1#6 AWG GND, CU TYPE THHN/THWN-2, IN 2" PVC BELOW GRADE AND RGS ABOVE 100A SERVICE DISCONNECTING MEANS INSTALLED ON GROUND LEVEL NEXT TO METER 100A DISCONNECT. CUSTOMER FURNISHED FOR UTILITY USE 480V, 3�, UTILITY SERVICE —� 4#2 AWG. UTILITY SERVICE LATERAL/DROP. COORDINATE WITH PROVIDER - AT&T SERVICE METER (BY UTILITY COMPANY) METER SOCKET (BY CONTRACTOR) \ #2 AWG FROM ANTENNA PIPE TO GROUND BAR c� 0 0 '\—INSTALL A NEW 12" AGB, FOR .* EACH SECTOR, NEAR ANTENNA MOUNTS (TOTAL OF 3) / ,IN, .1 TYPICAL ANTENNA GROUNDING PLAN ®IFI FULL SIZE PLOT SCALE: 1/2" = 1'-0" TRUEE NORTH HALF SIZE PLOT SCALE: 1/4" = 1'-0" 0 2' 4' i PROPOSED TECH LIGHT SEE 111.0 FOR DNDUIT AND WIRE 3#3/0 AWG + 1 #6 GRD, CU TYPE THHN/THWN-2, IN 2" RGS CONDUIT n � N E o L 2#10, 1"C 20A 15A DRAWN BY: TELCO CABINET GFCI 0 2#12, 20A 3/4 C 6 30A DATE DRAWN: DC POWER PLANT NEW 1" INNERDUCT WITH FIBER TO BTS EQUIPMENT TELCO BOX AT UTILITY H —FRAME TELCC NEW 1-1/4" CONDUIT FOR FIBER HAND—OFF 2 ONE -LINE DIAGRAM SCALE: N.T.S. rIfCJI LCV CL GROUNDING NOTES: 1. ANTENNA GROUND BARS SHALL BE INSTALLED WITHOUT INSULATOR (CHERRY) USING UL LISTED MOUNTING DEVICES. 2. POLISH GALVANIZED SURFACES WITH A STEEL BRUSH FOR ALL CONNECTING SURFACES. ABB AGB G MGB GROUNDmmm���� ANTENNA GROUND 14A,STER GROUND GROUNDING LEGEND: SYMBOL DESCRIPTION • EXOTHERMIC WELD — —G—G­ GROUND WIRE • MECHANICAL CONNECTION VOLT 120/240 1 PH 3W 142,000 AIC PANEL A"BUMLOAMCB MCB 200ATING X FUSHCE X NEMA 1 PPC AT AT&T EQUIPMENT NEMA 3R ALL BREAKERS ARE 20A UNLESS OTHERWISE NOTED NO WIRE & CONDUIT KVA DESCRIPTION ( OOA DESCRIPTION KVA WIRE & CONDUIT NO 1 2#10, #10G, 1"C 3.6 RECTIFIER 1 30 60 TVSS 2 3 4 5 2#10, 1"C 3.6 RECTIFIER 2 30 DRAWN BY: TELCO CABINET GFCI .18 2#12, #12G, 3/4 C 6 7 DATE DRAWN: 10/16/13 REVISION 15 TECH LIGHT .5 2#12, #12G, 3/4"C 8 �1 9 2#10, #10G, 1"C 3.6 RECTIFIER 3 30 11 13 2#10, 1 "C 3.6 RECTIFIER 4 30 15 17 2#10, 1"C 3.6 RECTIFIER 5 30 19 21 2#12, #12G, 3/4"C 1.4 POWER CABINET HEATER 23 2#12, #12G, 3/4"C .18 POWER CABINET GFCI CONNECTED LOAD: 20.26 kVA DEMAND LOAD: 24.76 kVA *:) PANEL SCHEDULE v SCALE: N.T.S. 10 12 14 16 18 20 22 24 kiall 0 TI-3A=to]10 ° Ar xov ONN AT&T MOBILITY 1801 VALLEY VIEW LANE FARMERS BRANCH, TX 75234 CONSULTANT: SITE NAME: SITE NUMBER: HX3572 SITE ADDRESS: 301 GEORGE BUSH DRIVE COLLEGE STATION, TX 77840 BRAZOS COUNTY 11/15/2013 /...oC$:•...•..••....••�a;•.•:..•. ANTHONY L. HUEBEL ro102126 IIAL SHEET TITLE: 'ANTENNA GROUNDING, AND ONE -LINE E2.0 1001\1 dd vqq000h \\\\g ...... \ CONSULTING ENGI'NE'ERS, INC. 19315 FM 2252, STE. 301 PH: (210) 542-5911 GARDEN RIDGE, TX 78266 F-13646 DRAWN BY: RS APPROVED BY: TH DATE DRAWN: 10/16/13 REVISION NO DESCRIPTION BY DATE 0 ISSUED FOR CONSTRUCTION RS 10/22/13 1 REVISED PER RFDS TH 10/31/13 2 REVISED PER COMMENTS WS 11/14/13 SHEET TITLE: 'ANTENNA GROUNDING, AND ONE -LINE E2.0 GENERAL NOTES 1. REFER TO GENERAL NOTES, SHEET N SHEETS FOR SITE COORDINATION REQUIREMENTS 2. COORDINATE WITH CONSTRUCTION MANAGER TO OBTAIN CURRENT APPLICABLE TOWER GROUNDING REQUIREMENTS FROM AT&T WIRELESS. 3. USE TINNED COPPER (SOLID) FOR EXTERIOR GROUNDING (TYPICALLY #2 OR AS NOTED); USE STRANDED COPPER WIRE FOR GROUNDING WHERE NOT EXPOSED AND NOT IN CONTACT WITH EARTH (SEE NOTE 4 BELOW) 4. BURY ALL BARE GROUND WIRES MIN. 18" BELOW GRADE OR 6" BELOW FROST LINE WHICHEVER IS GREATER. LOCATE NO CLOSER THAN 2' FROM FENCE OR 24" FROM FOUNDATIONS. SLEEVE ALL FOUNDATIONS. CADWELD AND TEST CONDUCTIVITY OF ALL GROUND TIE POINTS. 5. TO MINIMIZE LIGHTNING DAMAGE, NO SHARP BENDS PERMITTED IN ANY WIRING, INCLUDING GROUNDING. 6. GROUND RODS TO BE COPPER CLAD STEEL 5/8" DIAMETER X 10'-0" LONG WITH TOPS BURIED 18" MINIMUM BELOW FINISHED GRADE, CADWELD TO GROUND RING RODS SHALL BE SPACED 10' TO 15' ON CENTER ALONG THE GROUND RING. 7. PRIME AND EPDXY PAINT ALL EXPOSED CONDUIT TO MATCH EXTERIOR OF EQUIPMENT BUILDING. 8. ELECTRICAL CONTRACTOR SHALL CONNECT EXTERIOR GROUNDING WIRE TO GROUND RING INSIDE EQUIPMENT SHELTER. TOWER CONTRACTOR SHALL MAKE ALL ABOVE GROUND CONNECTIONS TO TOWER BUSS BARS AND WAVEGUIDE BRIDGES AT THE TIME OF CONNECTION TO THE TOWER. ONE CONNECTION TO THE TOWER BASE SHALL BE A MECHANICAL TYPE. ALL OTHERS SHALL BE CAD WELDED, SEE NOTE 10 BELOW. 9. CIVIL CONSTRUCTION CONTRACTOR SHALL BURY ALL GROUND RINGS AND CADWELD PIGTALS FOR ALL ABOVE GROUND CONNECTIONS AT THE TIME OF GROUND RING INSTALLATION. PROTECT AND SUPPORT ALL WIRING SUCH THAT IT WILL NOT VIBRATE/RUB AGAINST OTHER METALLIC OBJECTS AND SUCH THAT THERE ARE NO SHARP BENDS (NOMINAL RADIUS 8" MIN.) 10. CADEWELD ALL CONNECTIONS WHERE POSSIBLE AT TOWER OR LOCATION OF MULTIPLE CADWELD CONNECTIONS, IT MAY BE PERMISSIBLE TO MECHANICALLY BOLT A BUSS BAR TO GROUND OR TO SUPPORT STRUCTURE. 11. THE RESISTANCE BETWEEN ANY POINT ON THE GROUND SYSTEMAND REFERENCE GROUND SHOULD BE 5 OHMS OR LESS. NOTIFY CONSTRUCTION MANAGER IMMEDIATELY IF THIS IS NOT POSSIBLE DUE TO SOLID CONDITIONS FOR ALTERNATIVES. 12. GRIND OFF GALVANIZING IN AFFECTED AREA. EXOTHERMICALLY WELD #2 CONDUCTOR AT 6 INCHES ABOVE GRADE OR FOUNDATION, WHICHEVER IS HIGHER. COLD—GALV AFTER. EXOTHERMICALLY WELD OTHER END TO GROUND. 13. GROUND CONDUCTORS ON EXTERIOR WALL OF SHELTER SHALL BE ENCASED IN 3/4" PVC CONDUIT TO GRADE. MOUNT PVC WITH GALVANIZED "C" CLAMPS. SEAL TOP ENDS. 14. FOLLOWING COMPLETION OF WORK, CONDUCT GROUND TEST. SUBMIT WRITTEN TEST TO CONSTRUCTION MANAGER AND PROJECT MANAGER. 15. ALL GROUNDING SHALL L B EI N ACCORDANCE DA NC E W ITH ATB T, S GROUNDING DIN G AND BONDING STANDARDS FOR CELL SITES. ALL TESTING SHALL BE CONDUCTED PER AT&T STANDARDS AND COMPLY WITH ALL STATE AND LOCAL CODES, AND THE NATIONAL ELECTRICAL CODE (NEC). 16. GROUND RODS SHALL NEVER BE SPACED HORIZONTALLY CLOSER THAN TWICE THE GROUND ROD LENGTH. 17. UNLESS NOTED OTHERWISE, ALL GROUNDING CONNECTIONS SHALL BE MADE BY AN EXOTHERMIC WELD. 18. NOTIFY THE CONSTRUCTION MANAGER 24 HOURS IN ADVANCE WHEN THE BURIED GROUND RING IS INSTALLED SO THAT A REPRESENTATIVE CAN INSPECT THE GROUND RING BEFORE IT IS BACKFILLED WITH SOIL. GROUNDING LEGEND: SYMBOL DESCRIPTION • EXOTHERMIC WELD — --G—G— GROUND WIRE m MECHANICAL CONNECTION GROUNDING KEYED NOTES• O PROVIDE TINNED COPPER GROUND BARS MOUNTED DIRECTLY WITH NO INSULATORS. PROPOSED WOOD FENCE TO MATCH VERIZON'S FENCE PROPOSED AT&T 12'-6"X25' LEASE AREA .4F AW(` F-Q(nn #2 AWG FROM GROUND BAR ON H— FRAME TO MGB. ROUTE EACH IN 3/4" PVC CONDUITS SECURED TO CEILING PROPOSED LTE PURCELL CABINET— PROPOSED UMTS PURCELL CABINET — ... . u c a G PROPOSED AT&T 4'X6' I" CONDUIT WITH 1/0 AWG FROM PROPOSED GROUND BAR TO NEW 10' GROUNDIN(. FI Fr,TRnnl= FUTURE PURCELL CABINET PROPOSED AT&T UTILITY H—FRAME W/ DISCONNECT, PPC CABINET, AND CIENA 3911 PROPOSED AT&T CABLE TRAY ATTACHED TO EXISTING CEILING OF PARKING GARAGE EXISTING WOODEN FENCE (VERIZON) 1 AT&T COMPOUND GROUNDING PLAN FULL SIZE PLOT S( -ALE: 1 ' /4" = 1-0" TRUE HALF SIZE PLOT SCALE: 1/8" NORTH 0 2' 4' 8) PROPOSED 6' ACCESS GATE #2 AWG BONDED TO BUILDING STEEL----,, #2 AWG BTCW TO GROUNDING ELECTRODE BELOW VERTICAL COAX RUN AT BUILDING CORNER 10' X 5/8" COPPER GROUNDING ELECTRODE �G_ fidm�� WE \a AWIR 00.at,,,t . ..... AT&T MOBILITY 1801 VALLEY VIEW LANE FARMERS BRANCH, TX 75234 CONSULTANT: Good ma n Networks 6400 INTERNATIONAL PARKWAY SUITE 1000 PLANO, TX 75093 Tel: (972) 406.9692 SITE NAME: 1114194:1 SITE NUMBER: HX3572 SITE ADDRESS: 301 GEORGE BUSH DRIVE COLLEGE STATION, TX 77840 BRAZOS COUNTY 11/15/2013``, �E OF r 0 �An ANTHONY L. HUEBEL / 1 ............................... 1-01% 102126 r \ L vc\\\\\\ CONSULTING EN�G�I�NEE'R�S, ..INC. 19315 FM 2252, STE. 301 PH: (210) 542-5911 "! GARDEN RIDGE, TX 78266 F-13646 DRAWN BY: RS ISI'' APPROVED BY: TH DATE DRAWN: 10/16/13 REVISION NO DESCRIPTION BY DATE 0 ISSUED FOR CONSTRUCTION RS 10/22/13 1 REVISED PER RFDS TH 10/31/13 2 REVISED PER COMMENTS WS 11/14/13 SHEET TITLE: SHEET NUMBER: E2.1 .� GROUNDING SCHEMATIC SCALE: N.T.S. #2 AWG SOLID TINNED COPPER CONDUCTOR TO COLLECTION GROUND BAR TO GROUND RING (WHERE INSULATORS USED) - 4"x24"x 1 /4" TINNED COPPER GROUND BAR (HARGER OR APPROVED EQUIVALENT) 2 GROUND BAR DETAIL COPPER BONDING CONDUCTORS TO CABLES AND EQUIPMENT. SEE GROUNDING PLANS FOR DETAILS 3/8" BOLT AND HARDWARE (TYP.), CHERRY INSULATOR NOT USED WHEN DIRECT ATTACHMENT TO TOWER R S TE EL IS REQUIRED Q ED WALL—MOUNT BRACKET OR ANGLE ADAPTER (AS REQUIRED) CLEAR HEAT SHRINK TUBING #6 GREEN INSULATED BONDING JUMPER PRIMARY GROUND BAR/ METAL ENCLOSURE 2 HOLE LUG 3/8"-20 HEX BOLT 3/8"—FLAT WASHER 3/8" EXT. TOOTH LOCKWASHER 3/8"-20 HEX NUT INSTALLATION NOTES: 1. SELECT BOLT LENGTH TO PROVIDE A MINIMUM OF TWO EXPOSED THREADS. 2. BURNISH MOUNTING SURFACE TO REMOVE PAINT IN THE AREA OF LUG CONTACT, 3. APPLY ANTI—OXIDANT COMPOUND TO MATING SURFACE OF LUG AND WIPE CLEAN EXCESS COMPOUND. 4. USE SOLID COPPER WIRE AND MECHANICAL 2—HOLE LUG FOR ALL EXTERIOR GROUNDING. 3 MECHANICAL GROUND CONNECTION SCALE: N.T.S. QUIPMENT CONDUCTOR 100A SERVICE DISCONNECTING MEANS (CUSTOMER OWNED) )ING ELECTRODE TYPE GL 4 TYPICAL CADWELD CONNECTIONS SCALE: N.T.S. mm at&t.WN AT&T MOBILITY 1801 VALLEY VIEW LANE FARMERS BRANCH, TX 75234 CONSULTANT: %aoodman Networks 6400 INTERNATIONAL PARKWAY SUITE 1000 PLANO, TX 75093 Tel: (972) 406.9692 SITE NAME: SITE NUMBER: HX3572 SITE ADDRESS: 301 GEORGE BUSH DRIVE COLLEGE STATION, TX 77840 BRAZOS COUNTY 11/15/2==:`"`\\ �E OF00 r \ 1 * i. ••�JYs•••••••••••••••u;'i•••••••• ANTHONY L. HUEBEL ....: ..................... *Q 010, off; s,102126�; �,�, 11\%%% L Amm ,mv , CONSULTING .. \ U EN�G�INE,E�RS, IN.C. 19315 FM 2252, STE. 301 PH: (210) 542-5911 GARDEN RIDGE, TX 78266 F-13646 DRAWN BY: RS APPROVED BY: TH DATE DRAWN: 10/16/13 REVISION NO DESCRIPTION BY DATE 0 ISSUED FOR CONSTRUCTION RS 10/22/13 1 REVISED PER RFDS TH 10/31/13 2 REVISED PER COMMENTS WS 11/14/13 SHEET TITLE: ELECTRICAL DETAILS SHEET NUMBER: E3.0 GRADE GROUND RING 2 AWG BCW SOLID, TINNED GROUND ROD COPPER CLAD STEEL ROD 5/8"0 X 8' LONG MIN. 5/8"0 X10' LONG TYPICAL NOTE: 1. DEPTH SHALL BE MIN. 18" OR 6" BELOW THE FROST LINE, WHICHEVER IS GREATER 2. GROUND ROD SHALL BE DRIVEN VERTICALLY, NOT TO EXCEED 45 DEGREES FROM THE VERTICAL .� TYPICAL GROUND ROD DETAIL SCALE: N.T.S. #6 AWC ANTENN L SCALE: N.T.S. AWG GREEN #6 AW JLATED FROM ANTEN ENNA MOUNT NOTE: CONTRACTOR TO UTILIZE ANTI—OXIDATION COMPOUND (THOMAS & BETTS) ON ALL LUG CONNECTIONS. A TYPICAL UPPER GROUND BAR_ -DETAIL NOTE: CONTRACTOR TO UTILIZE ANTI—OXIDATION COMPOUND (THOMAS & BETTS) ON ALL LUG CONNECTIONS. TYPICAL MIDDLE GROU-ND BAR DETAIL (IF REQ'D) 30" 1 3/4" 3/4" d- 7/16"O X 5/8" 1 CHERRY INSULATOR 3) `42 NOTES: 1 TINNED COPPER GROUND BUSS BAR, 1 /4"x4"x30", WITH NON -INSULATED MOUNTINGIIT OR EQUIVALENT. 2 GROUND BAR SHALL BE SIZED TO ACCOMMODATE ALL GROUNDING CONNECTIONS REQUIRED PLUS PROVIDE 50% SPARE CAPACITY 3 APPLY CONDUCTIVE LUBRICANT (NO—OX COMPOUND OR APPROVED EQUIVALENT) TO EXPOSED AREA OF GROUND BAR. TYPICAL MASTER GROUND BAR DETAIL W SCALE: N.T.S. #6 AWG FROM ANTENNA COAX 3/4" PVC FLEX CONDUIT (TYP.) NOTE: CONTRACTOR TO UTILIZE ANTI—OXIDATION COMPOUND (THOMAS & BETTS) ON ALL LUG CONNECTIONS. SCALE: N.T.S. 10000 at.&t............... AT&T MOBILITY 1801 VALLEY VIEW LANE FARMERS BRANCH, TX 75234 CONSULTANT: %jood man Networks 6400 INTERNATIONAL PARKWAY SUITE 1000 PLANO, TX 75093 Tel: (972) 406.9692 SITE NAME: FBI A AN" _0 SITE NUMBER: HX3572 SITE ADDRESS: 301 GEORGE BUSH DRIVE COLLEGE STATION, TX 77840 BRAZOS COUNTY 11/15/2013 �.S• ;ova •. o R. � �� `,J� �•� Com'• %... ......... 0....V...Lt / / ANTHONY L. HUEBEL / 102126 �00 oma' ..F� / STER`:� ONAL :.::.:.::.:: _%babbb- %xv \\ \ 120 \ 11 CO�NS�ULTING. ENGINEERS, �.I�N.C. 19315 FM 2252, STE. 301 PH: (210) 542-5911 GARDEN RIDGE, TX 78266 F-13646 DRAWN BY: RS APPROVED BY: TH DATE DRAWN: 10/16/13 REVISION NO I DESCRIPTION BY I DATE 0 ISSUED FOR CONSTRUCTION RS 10/22/13 1 REVISED PER REDS TH 10/31/13 2 REVISED PER COMMENTS WS 11/14/13 SHEET TITLE: GROUNDING DETAILS i�,HEET NUMBER: E4mO DIVISION 16 ELECTRICAL SPECIFICATIONS 16000 SCOPE OF WORK: 16002 SPECIAL CONDITIONS FOR ELECTRICAL_ WORK 16700 EQUIPMENT CONNECTIONSIN (CONT): 1. THE REQUIREMENTS PRESENTED IN THESE SPECIFICATIONS PERTAINS TO 1. PROVIDE ELECTRICAL POWER AND LIGHTING CONNECTIONS FOR ALL EQUIPMENT o� OWER RACEWAY SYSTEM FOR ON THE PROJECT WHETHER FURNISHED BY THIS CONTRACTOR OR OTHERS. INSTALLATION OF A COMPLETELY NEW P ACEWA ELECTRICAL IN at&t 15. IN ADDITION TO THE ABOVE REQUIRED RECORD DRAWINGS, THE CONTRACTOR THE AT&T WIRELESS INSTALLATION TO THE EXTENT REQUIRED BY THESE LL FURNISH TO AT&T WIRELESS AT THE COMPLETION OF THE WORK THE 2. CAREFULLY RESEARCH THE DOCUMENTS AND CONSULT WITH OTHERS TO SHA DETERMINE THE REQUIREMENTS FOR CONNECTIONS. \ CONTRACT DOCUMENT. IN GENERAL, THE ELECTRICAL CONTRACTOR (HEREAFTERATIONS AND FOLLOWING DOCUMENTS: TEST REPORTS, WARRANTIES, OPER ALTERNATELY REFERRED TO AS 'CONTRACTOR') SHALL PROVIDE OR RESTORE MAINTENANCE MANUALS AND INFORMATION: THE FOLLOWING EXISTING SYSTEMS: A. A CERTIFICATE OF GUARANTEE/WARRANTY SHOWING THE DATES OF 16900 SPECIAL MODULAR CELL INSTALLATION GROUNDING A. CONDUIT AND RACEWAYS FOR ALL DEVICES, EQUIPMENT, GROUND BEGINNING AND ENDING OF THE WARRANTYINTEGRITY AND IMPEDANCE TESTING: AT&T M 0 BI LITY BUSSES AND GROUND RODS INDICATED ON THE ELECTRICAL PLANS. B. DOCUMENTS PERTINENT TO THE GUARANTEES AND WARRANTIES OF B. CONTRACTOR SHALL RUN FEEDERS SHOWN TO SUPPLY POWER TO ALL MANUFACTURERS. 1801 VALLEY VIEW LANE EQUIPMENT INDICATED PRIOR TO BID. CONTRACTOR SHALL DETERMINE C. WRITTEN INSTALLATION INSTRUCTIONS FOR EQUIPMENT INSTALLED ON 1. CONTRACTOR SHALL PRESENT MEASUREMENTS SHOWING CERTIFIED THIRD PARTY FARMERS BRANCH, TX 75234 ANY ADDITIONAL POWER OR GROUNDING WHICH MAY BE REQUIRED THE PROJECT. GROUND IMPEDANCE TESTING AS REQUIRED BY THE CONTRACT DOCUMENTATION. DEPENDING ON EQUIPMENT SPECIFIC TO THIS SITE AND BUILDING D. THREE SETS OF CUT SHEETS FOR EACH PIECE OF EQUIPMENT TESTING PER ANSI/IEEE STD 81-1983, IEEE GUIDE FOR MEASURING EARTH ENCLOSURE. INSTALLED FOR ELECTRICAL SYSTEMS. RESISTIVELY SHALL BE AS APPROVED BY AT&T WIRELESS CONSTRUCTION CONSULTANT: 2. CONTRACTOR(S) WISHING TO BID THIS WORK SHALL BE ABLE TO DEMONSTRATE E. CERTIFIED RESISTANCE MEASUREMENT DATA AND DRAWINGS USED MANAGEMENT. A MINIMUM OF 5 YEARS PREVIOUS EXPERIENCE WITH THIS TYPE OF PROJECT DURING CONSTRUCTION. 2. THIS INSTALLATION SHALL BE GROUNDED WITH AN INTEGRATED (MULTI -POINT) AND SHALL, IF REQUESTED, SUPPLY DOCUMENTATION TO SUPPORT THIS 16. ALL MATERIALS SHALL BE NEW AND OF DOMESTIC, OR IF APPROVED, NAFTA GROUNDING SYSTEM. REQUIREMENT OF QUALIFICATION. MANUFACTURE. ALL ITEMS OF THE SAME TYPE ON THE PROJECT SHALL BE OF 3. EACH QUALIFIED BIDDER SHALL OBTAIN ALL PROPER BID FORMS AND SHALL THE SAME MANUFACTURER. 3. SURGE PROTECTION SHALL BE AT&T WIRELESS APPROVED EQUIPMENT. IT SHALL VISIT THE SITE TO DETERMINE ACTUAL EXISTING CONDITIONS PRIOR TO 17. PRODUCTS OF VARIOUS MATERIALS AND EQUIPMENT ARE SPECIFIED IN ORDER BE BONDED DI AGROUND BAR AT THE SERVICE ENTRANCE POINT THAT IS CONNECTED DIRECTLY TO THE GROUNDING ELECTRODE SYSTEM. PREPARING A BID. TO ESTABLISH A STANDARD OF QUALITY AND A BASIS OF DESIGN. OTHER 4. REVIEW EXISTING INSTALLATION AND FOLLOW AT&T WIRELESS CELL SITE 4. CONTRACTOR SHALL NOTE THAT IF THIS CURRENTLY HOSTS ONE OR MORES PROVIDED THEY SIMILAR MATERIALS MAY BE ACCEPTABLE AS SUBSTITUTION GROUNDING AND LIGHTNING PROTECTION STANDARDS REPORT PERCEIVED OTHER TENANTS WITH TELEPHONE AND/OR ELECTRICAL SERVICE, CONTRACTOR MEET THE SAME STANDARDS OF QUALITY AND DESIGN CRITERIA IN THE DIFFICULTIES WITH MEETING THIS CRITERIA WITH AT&T WIRELESS CONSTRUCTION SHALL NOT CAUSE LOSS OF POWER, COMMUNICATION OR ANY REQUIRED OPINION OF THE ENGINEER ALTERNATE ITEMS SHALL BE SUBMITTED TO THE MANAGEMENT. OTHER REQUIRED STANDARDS SHALL BE: NFPA-780 STANDARD SERVICES TO AT&T WIRELESS OR ANY OTHER SITE OCCUPANT IN ANY ENGINEER FOR APPROVAL PRIOR TO INSTALLATION. THE DECISION OF THE FOR INSTALLATION OF LIGHTNING SYSTEMS AND POLYPHASER EQUIPMENT; AND, MANNER WITHOUT EXPRESS WRITTEN DIRECTION BY AT&T WIRELESS ENGINEER REGARDING ACCEPTABILITY SHALL BE FINAL. THE CONTRACTOR SHALL � �� �' 'THE GROUNDS FOR LIGHTNING PROTECTION AND EMP PROTECTION", SECOND �•� o o d m a'• •' Networks CONSTRUCTION SUPERVISION. THE CONTRACTOR SHALL BE LIABLE FOR ANY LOSS BEAR ALL COSTS, INCLUDING THAT OF OTHER TRADES AND THE DESIGN TEAM, EDITION BY ROGER R. BLOCK. OF REVENUE TO ANY SITE OCCUPANT BECAUSE OF ANY NONSCHEDULED ASSOCIATED WITH ACCOMMODATIONS FOR PERMITTED SUBSTITUTIONS. 5. THE ELECTRICAL CONTRACTOR SHALL PROVIDE BONDING STRAPS, CAD WELDING OUTAGES AS DETERMINED BY CONTRACT AGREEMENT WITH AT&T WIRELESS. AND HARDWARE FOR EACH SEPARATE PIECE OF THE EQUIPMENT MOUNTING 6400 INTERNATIONAL PARKWAY PLATFORM TO ASSURE THAT ALL PIECES ARE ELECTRICALLY CONNECTED. SUCH SUITE 1000 16001 GENERAL: 16123 WIRE AND CABLE CONNECTIONS SHALL BE MADE AND TESTED TO DEMONSTRATE LOW ELECTRICAL PLANO TX 75093 1. IT IS THE INTENTION OF THESE SPECIFICATIONS AND THE RELATED PLANS TO RESISTANCE ACCEPTABLE TO AT&T WIRELESS BETWEEN ANY TWO POINTS ON SHOW COMPLETE, PROPERLY FUNCTIONING SYSTEMS. ALL SYSTEMS, WIRING AND 1. ALL WIRE AND CABLE SHALL BE COPPER OF AT LEAST 989 CONDUCTIVITY. THE PLATFORM, MOUNTS OR STRUCTURE. Tel: (972) 406.9692 RACEWAYS SHALL BE INSTALLED PER NFPA-70 (APPLICABLE) AND AUTHORITY 2. ALL INSULATION SHALL BE TYPE THWN EXCEPT TYPE THW MAY BE USED FOR HAVING JURISDICTION SIZES LARGER THAN #6 AWG. 3. NO WIRE SMALLER THAN #12 AWG MAY BE USED EXCEPT THAT CONTROL SITE NAME: 16002 SPECIAL CONDITIONS FOR ELECTRICAL WORK: CIRCUIT MAY BE #14. 4. A STRICT METHOD OF COLOR CODING SHALL BE MAINTAINED. UNLESS THE AUTHORITY HAVING JURISDICTION HAS A DIFFERENT STANDARD, THE FOLLOWING 1. THE CONSTRUCTION DOCUMENTS INCLUDING BUT NOT LIMITED TO THESE PLANS, SHALL BE MAINTAINED: A PHASE: BLACK; B PHASE: RED; (AND WHERE USED,) DEXTER SPECIFICATIONS, AND CONTRACTS ARE ISSUED FOR INFORMATION TO BE C PHASE: BLUE; NEUTRAL: WHITE; GROUND: GREEN; SWITCH LEG: BROWN: COMPLIED BY THE ELECTRICAL CONTRACTOR AND ANY OR ALL SUBCONTRACTORS TRAVELERS: BROWN. AND TRADES EMPLOYED ON THIS PROJECT BY THE ELECTRICAL CONTRACTOR, 5. WIRE CONNECTORS FOR #8 AND SMALLER MAY BE SPRING STEEL CONNECTORS. SITE NUMBER: HEREAFTER REFERRED TO AS CONTRACTOR. SPLIT BOLT CONNECTORS WITH RUBBER AND VINYL TAPE SHALL BE USED FOR 2. THE TERM "CONTRACTOR" IN THIS SECTION REFERS TO THE CONTRACTOR WHOSE SIZES LARGER THAN #8. POWER DISTRIBUTION BLOCKS MAY BE USED FOR ANY 1 u 1X3572 WORK IS COVERED BY THIS ELECTRICAL SPECIFICATION. SIZE CONDUCTOR FOR WHICH IT IS LISTED. 3. ALL WORK SHALL BE DONE AND TESTED IN ACCORDANCE WITH THESE PLANS 6. UL LISTED WIRE PULLING LUBRICANT SHALL BE USED ON ALL RACEWAY AND SPECIFICATIONS AND WITH LOCAL AND NATIONAL CODES. REPORT SITE ADDRESS: SUPPOSED CONFLICTS WITH PLANS AND SPECIFICATIONS IMMEDIATELY TO THE INSTALLATIONS. CONSTRUCTION SUPERINTENDENT WHO WILL ISSUE INSTRUCTIONS OR ADDENDA 301 GEORGE BUSH DRIVE TO RESOLVE SUCH CONFLICT. IN NO CASE SHALL A CONTRACTOR BASE ITS 16130 RACEWAY SYSTEMS COLLEGE STATION, TX 77840 BID ON WORK THAT WILL NOT BE ACCEPTABLE TO CODE AND THESE CONTRACT DOCUMENTS. NO CONSIDERATION SHALL BE GIVEN TO REQUESTS BRAZOS COUNTY FOR EXTRA COMPENSATION TO BRING THE BASE WORK INTO CONFORMANCE 1. ALL WIRING ABOVE GRADE OR OTHERWISE EXPOSED SHALL BE IN METALLIC WITH THESE DOCUMENTS. CONDUIT. TYPE MC CABLE OR FLEXIBLE CONDUIT MAY NOT BE USED UNLESS 4. ALL MATERIAL FOR WHICH THERE IS A CATEGORY FOR TESTING BY UL OR CSA SHOWN OR REQUIRED BY THESE SPECIFICATIONS EMT, GALVANIZED INTERMEDIATE SHALL BE SO TESTED, LISTED AND LABELED. AND RIGID CONDUIT ARE ALL ACCEPTABLE WIRING MATERIALS FOR ABOVE 5. AS MENTIONED ABOVE, IT IS THE INTENT OF THESE DOCUMENTS TO PRODUCE A GRADE PROVIDED THEY ARE ACCEPTABLE TO LOCAL CODE ENFORCEMENT. COMPLETE AND FINISHED ELECTRICAL SYSTEM TO THE EXTENT SHOWN IN THESE 2. ALL FITTINGS SHALL BE COMPRESSION TYPE OR SCREW TYPE AND MAY NOT BE _ CONTRACT DOCUMENTS. THE AT&T WIRELESS CONSTRUCTION MANAGER SHALL DIE CAST SET SCREW. BE THE FINAL AUTHORITY FOR ACCEPTANCE OF THE WORK. THE CONTRACTOR IS 3. CONDUIT BELOW GRADE SHALL BE SCHEDULE 40 PVC WITH MATCHING FITTINGS 11/15/2013 SOLELY RESPONSIBLE FOR COORDINATING HIS WORK WITH OTHER` TRADES AND EXCEPT THAT ELBOWS AND VERTICAL CONDUITS IN CONTACT WITH EARTH WHICH WITH HIS SUBCONTRACTORS AS NECESSARY TO PROVIDE A FINAL AND ARE LIKELY TO BE DAMAGED BY EXCESSIVE PULLING ROPE TENSION MAY BE ELECTRICAL INSTALLATION. PLASTIC WRAPPED INTERMEDIATE OR RIGID GALVANIZED STEEL. �P�E 0� rF,ttt COMPLETE ELE -� a••'� ��� .�S� i>,>.;,,`, 6. THE CONTRACTOR SHALL EMPLOY ONLY SKILLED, EXPERIENCED, AND WHEN 4. EXPOSED CONDUIT OUTDOORS ABOVE GRADE OR IN DAMP LOCATIONS SHALL BE ��y •` ,,t, lid REQUIRED, LICENSED SUB CONTRACTORS AND WORKERS. MATERIALS AND GALVANIZED RIGID STEEL OR INTERMEDIATE METALLIC CONDUIT. W EQUIPMENT SHALL BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURER'S 5. ULTRAVIOLET PROTECTED PLASTIC COATED FLEXIBLE METAL CONDUIT MAY BE 0o ANTHONY L. HUEBEL WRITTEN INSTRUCTIONS, IN ACCORDANCE WITH THE BEST TRADE PRACTICES AND USED WHERE INDICATED AND OTHERWISE FOR THE CONNECTION OF ROTATING 00 ••••:•••••••••••••••••••••:••••00 IN A NEAT AND WORKMAN LIKE MANNER. WORK WHICH IN THE OPINION OF THE OR VIBRATING EQUIPMENT. SUCH EQUIPMENT LOCATED OUTDOORS OR IN DAMP I o : 102126a CONSTRUCTION MANAGER DOES NOT CONFORM TO THE INTENT OF THESE PLANS LOCATIONS SHALL BE CONNECTED WITH LIQUID TIGHT FLEXIBLE METAL CONDUIT ��� o�'�.;,Oi STER' G ITTINS. 1 FS •••••••••• G\ �. AND SPECIFICATIONS SHALL BE REMOVED AND REPLACED AT THE CONTRACTOR'S USING LISTED Ftt�S/ONAL EXPENSE. 6. MINIMUM COVER FOR OUTDOOR CONDUITS SHALL BE 36 INCHES. NOTE: UTILITY \���`��. 7. THE PLANS AND DETAILS ARE DIAGRAMMATIC IN NATURE. COORDINATE THE CONDUITS MAY HAVE A GREATER DEPTH REQUIREMENT. LOCATION OF ITEMS NOT CLEARLY DIMENSIONED WITH THE CONSTRUCTION SUPERINTENDENT. 16250 GROUNDING 8. SECURE ALL NECESSARY PERMITS, LICENSES AND INSPECTIONS AND PAY ALL REQUIRED FEES, TESTS AND WAGE SCALES THAT MAY BE REQUIRED. THE 1. ALL EQUIPMENT AND SERVICE ENTRANCE GROUNDING SHALL BE PER NFPA-70 CONTRACTOR SHALL INCLUDE THE FINAL INSPECTION CERTIFICATE IN FINAL DOCUMENTS. CURRENT EDITION AS ADOPTED BY LOCAL AUTHORITY HAVING JURISDICTION ON 9. THE CONTRACTOR IS RESPONSIBLE FOR UNDERSTANDING THE EXISTING SITE THIS PROJECT. PER ARTICLE 250 AS WELL AS OTHER APPLICABLE CONDITIONS. HE SHALL VISIT THIS SITE (BY APPOINTMENT) AT ANY REASONABLE STANDARDS SUCH AS THE NATIONAL ELECTRICAL SAFETY CODE, NEPA 780 TIME. (LIGHTNING PROTECTION) AND AT&T WIRELESS STANDARDS ON EQUIPMENT 10. LOCATIONS OF UTILITY CONNECTIONS SHOWN ON THE SITE ARE APPROXIMATE GROUNDING.-E AND ARE BASED ON SITE OBSERVATIONS. ACTUAL UTILITY CONNECTIONS AND ���';>' <<>.EXACT LOCATIONS MAY VARY SLIGHTLY. THE CONTRACTOR SHALL CONTACT THE ES\�UTILITY COMPANIES INVOLVED PRIOR TO BID TO CONFIRM THE ACTUAL C16400 WIRING DEVIC ..... ':°:':� L :.`::`::"' CONDITIONS OF CONNECTION. THE CONTRACTOR SHALL INCLUDE IN HIS BID ��\ CO'NSULTING ENGINEERS, INC. THE ACTUAL CONDITIONS OF CONNECTION AND ANY FEES REQUIRED BY THE 1. ALL WIRING DEVICES SHALL BE SPECIFICATION GRADE RATED AT 20 AMPS. UTILITY FOR PROPOSED NEW 200 AMP, 240/120 VAC SINGLE PHASE UTILITY 2. PROVIDE DEVICES AS SHOWN ON DOCUMENTS. CONSULT WITH CONSTRUCTION 19315 FM 2252, STE. 301 PH: (210) 542-5911 MANAGER AND OTHER TRADES FOR EXACT LOCATION OF OUTLETS. WHERE GARDEN RIDGE TX 78266 F-13646 SERVICE THE CONTRACTOR SHALL COORDINATE WITH THE ELECTRICAL COMPANY OUTLETS SERVE A SPECIFIC PIECE OF EQUIPMENT AND WHERE POSSIBLE,. ' CONCERNING ITEMS WHICH HE MUST PROVIDE AND THE CONSTRUCTIONS SCHEDULE. CONCEAL OUTLET BEHIND THAT EQUIPMENT. DRAWN BY: RS 11. AFTER COMPLETION OF THE WORK AND BEFORE FINAL INSPECTION, THE CONTRACTOR SHALL THOROUGHLY CLEAN EACH EXPOSED DEVICE, PIECE OF 16500 PANEL BOARDS: VERIFY PROVIDED BY AT&T APPROVED BY: TH EQUIPMENT AND FIXTURE TO THE SATISFACTION OF THE CONSTRUCTION WIRELESS OR CONTRACTOR AND INSTALLED BY THIS SUPERINTENDENT. ( ) DATE DRAWN: 10/16/13 12. THE CONTRACTOR SHALL SUBMIT ALL MATERIALS LISTED BELOW TO THE CONTRACTOR. ENGINEER FOR APPROVAL PRIOR TO INSTALLATION. FAILURE TO OBTAIN REVISION APPROVAL ON MATERIAL SHALL BE CAUSE FOR CONTRACTOR TO REMOVE ANY 1. VERIFY THAT THE INTERRUPTING RATING OF CIRCUIT BREAKERS SHALL BE MATERIALS NOT APPROVED AND REPLACE THEM AT HIS OWN EXPENSE AND WITH GREATER THAN THE AVAILABLE FAULT CURRENT. VERIFY THE AVAILABLE FAULT NO DESCRIPTION BY DATE NO ALLOWANCE IN THE TIME ALLOWED FOR CONSTRUCTION. SUBMITTALS: CURRENT WITH THE SERVING ELECTRICAL UTILITY. 0 ISSUED FOR CONSTRUCTION RS 10/22/13 (PROVIDE IN QUANTITY REQUESTED BY THE CONSTRUCTION MANAGER) THE 2. PROVIDE SOLID NEUTRALS ON ALL PANELS AND MAIN SERVICE ENTRANCE FOLLOWING MINIMUM ITEMS SHALL BE SUBMITTED AT THE SAME TIME UNDER DISCONNECT (IF MAIN SERVICE DISCONNECT REQUIRED). 1 REVISED PER REDS TH 10/31/13 ONE COVER IN THE ORDER LISTED: 3. PROVIDE 1" BLACK MICARTA TAGS WITH 1/2" WHITE LETTERS FOR EACH TAB ONE: WIRE, CONDUIT, GROUND RODS, GROUND BUSSES, ELECTRICAL PANEL BOARD AND DISCONNECT MATCHING PROJECT DOCUMENTATION. TAGS 2 REVISED PER COMMENTS WS 11/14/13 (CAD)WELD DEVICES, METALLIC SHEATHED FLEXIBLE CONDUIT, SHALL BE "POP-RIVETTED" THROUGH PANEL COVER. OUTLET AND PULL BOXES. TAB TWO: SWITCHES, ENCLOSURES, CABINETS, TIMERS, AND RECEPTACLES TAB THREE:PANEL BOARDS, DISCONNECT SWITCHES (DESIGNATE USE OF EACH), FUSES, AND CIRCUIT BREAKERS OR OTHER CONTROL 16600 LIGHTING FIXTURES (IF SHOWN) DEVICES. 13. THE CONTRACTOR SHALL GUARANTEE THAT ALL WORK PERFORMED UNDER THIS 1. PROVIDE LIGHTING FIXTURES AS SHOWN ON THE DOCUMENTS. QUESTIONS ON CONTRACT IS FREE FROM DEFECTS IN MATERIAL AND WORKMANSHIP FOR ONE LIGHT FIXTURE TYPES SHALL BE DIRECTED TO AT&T WIRELESS FOR SHEET TITLE: YEAR (MINIMUM) FOLLOWING FINAL ACCEPTANCE BY THE OWNER'S CLARIFICATION. THE CONTRACTOR SHALL PROVIDE ALL LIGHTING FIXTURES. REPRESENTATIVE. THE CONTRACTOR SHALL RESPOND TO REQUESTS FOR 2. FASTEN EACH LIGHTING FIXTURE TO AN OUTLET BOX OR STRUCTURAL FRAMING. SERVICE IN A TIMELY MANNER APPROPRIATE TO THE SERVICE REQUESTED, THE INCLUDE ALL NECESSARY HARDWARE AND SUPPORTING DEVICES TO ACCOMPLISH ELECTRICAL CONTRACTOR SHALL IMMEDIATELY REPAIR OR REPLACE ANY ITEMS FOUND TO BE THIS. DEFECTIVE WITHIN THE GUARANTEE PERIOD AT NO COST TO THE OWNER. 3. PROVIDE NEW LAMPS OF THE TYPE RECOMMENDED BY THE PLANS AND SPECIFICATIONS 14. THE CONTRACTOR SHALL MAINTAIN ON THE SITE A SET OF CONSTRUCTION SPECIFICATION AT THE TIME OF FINAL ACCEPTANCE. DOCUMENTS MARKED IN RED TO SHOW THE ACTUAL CONDITIONS OF 4. ALL LIGHTING FIXTURES SHALL BE CLEAN AND FULLY OPERATIONAL AT THE TIME CONSTRUCTION. LOCATIONS OF EQUIPMENT AND ROUTING OF SYSTEMS SHALL BE OF FINAL ACCEPTANCE. ACCURATELY RECORDED DURING THE COURSE OF CONSTRUCTION. CONTRACTOR SHEET NUMBER: SHALL FORWARD A REPRODUCIBLE COPY OF THE RECORD DRAWINGS TO AT&T WIRELESS AT THE COMPLETION OF CONSTRUCTION AND SHALL MAINTAIN THE ORIGINAL RECORD DRAWINGS FOR USE DURING THE GUARANTEE PERIOD. FINAL PAY REQUEST SHALL NOT BE APPROVED WITHOUT THIS FINALIZED E4m 1 INFORMATION IN ACCORDANCE WITH AT&T WIRELESS CLOSE OUT INSTRUCTIONS.