HomeMy WebLinkAboutDrawingsVICINITY MAP O OC- TION WA CAS's OCK A� ZLIA. D. F1TCH PARKWAY STATE H1G1iW AY 40 _WL 0� N NOT TO SCALE OWNER/DEVELOPER: CASTLE ROCK HOMEOWNERS ASSOCIATION, INC. P.O. BOX 9748 COLLEGE STATION, TX 77845 SPLAS11 PAD ADDITION "s COMMON AREA (AMENITY CENTER) COLLEGE STATION, TEXAS - THE SEAL APPEARING ON THIS DOCUMENT WAS AUTHORIZED BY DEVEN L. DOYEN, P.E., LICENSE NO. 109835 MAY 6, 2015. ISSUED FOR REVIEW DEVEN L. DOYEN ..........a ,•ie 109835 i � FIRM # 12327 SCHULTZ ENGINEERING, LLC SCHEDULE OF SHEETS SHEET TITLE Cl SITE & EROSION CONTROL PI C2 LANDSCAPE & GRADING PLAN 0 70' ROW - 38' B-8 PAVEMENT WIDTH 07 y y i LIMITS OF DISTURBANCE %L5THE SEAL APPEARING ON THIS p r■ DOCUMENT WAS AUTHORIZED BY E 1 n 1 I I� �i 1 I nDEVEN L. DOYEN, P.E., g, LLL;LICENSE NO. 109835 2730 Longmire, Suite A MAY 6, 2015. College Station, Texas 77845 ISSUED FOR REVIEW 979.764.3900 TBPE NO. 12327 SURVEYED DESIGNED DRAWN APPROVED JOB NO. DATE KERR DLD DLD JPS 15-384 1 MAY 2015 '##fjj;�V_ OF f " .*.................... *. �DEVEN L DOYEN '. 109835 . FIRM # 1232101`9' SCHULTZ ENGINEERING, LLC 20 10 0 20 SCALE IN FEET 2"X4' WIRE MESH (OPTIONAL) FASTENED TO T -POST OR WOODEN STAKE METAL T -POST OR WOODEN STAKE AS REQUIRED TO MAINTAIN. SPACED 6' APART NATURAL 4"X4' MIN. SEDIMENT CONTROL FABRIC FASTENED SECURELY TO T -POST OR WOODEN STAKE WITH OPTIONAL WIRE MESH 8' OF FILTER FABRIC TO EXTEND INTO A TRENCH AND BE ANCHORED WITH COMPACTED BACKFILL DIREF FLOW 4. T I -ALLOW 2.5' TO 5' AT TOE OF SLOPE FOR SEDIMENT 20' TO ACCUMULATE. ALIGN I FENCE ALONG SLOPE i CONTOURS. STILT FENCE ASSEMBLY DETAIL N.T.S. GENERAL NOTES: 1. ALL CONSTRUCTION SHALL BE IN ACCORDANCE WITH THE LATEST CITY OF-BRYAN/COLLEGE STATION STANDARD SPECIFICATIONS AND DETAILS FOR (WATER, SEWER, STREETS, DRAINAGE). ALL CONSTRUCTION SHALL BE COORDINATED WITH THE CITY ENGINEER'S OFFICE. 2. ALL UTILITY LINES (WATER, GAS, SANITARY SEWER, STORM SEWER, ETC.) SHOWN ARE TAKEN FROM BEST AVAILABLE RECORD INFORMATION BASED ON CONSTRUCTION UTILITY MAP DOCUMENTS OBTAINED FROM CITY & INDEPENDENT AGENCIES AND/OR ABOVE GROUND FIELD EVIDENCE. SHOWN POSITIONS MAY NOT REPRESENT AS -BUILT CONDITIONS 3. THE CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING THE EXACT LOCATION OF ALL EXISTING UNDERGROUND UTILITIES. NOTIFICATION OF THE UTILITY COMPANIES 48 HOURS IN ADVANCE OF CONSTRUCTION IS REQUIRED. DIG TESS: (800) 344-8377 ATMOS ENERGY- (979) 774-2506 SUDDEN LINK COMMUNICATIONS: (979) 595-2429 VERIZON: (979) 821-4770 4. THE CONSTRUCTION SHALL COMPLY WITH OSHA STANDARD 29 CFR PART 1926 SUBPART P FOR TRENCH SAFETY REQUIREMENTS. 5. BUILDING SETBACK SHALL BE IN ACCORDANCE WITH THE CITY OF COLLEGE STATION UNIFIED DEVELOPMENT ORDNANCE. 6. PROPOSED SIGNS SHALL BE PERMITTED SEPARATELY IN ACCORDANCE WITH THE UDO. 7. ALL ROOF AND GROUND -MOUNTED MECHANICAL EQUIPMENT SHALL BE SCREENED FROM VIEW OR ISOLATED SO AS NOT TO BE VISIBLE FROM ANY PUBLIC RIGHT-OF-WAY OR RESIDENTIAL DISTRICT WITHIN 150' OF THE SUBJECT PROPERTY, MEASURED FROM A POINT 5 FEET ABOVE GRADE. SUCH SCREENING SHALL BE COORDINATED WITH THE BUILDING ARCHITECTURE AND SCALE TO MAINTAIN A UNIFIED APPEARANCE. 8. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO USE WHATEVER MEANS NECESSARY TO MINIMIZE EROSION AND PREVENT SEDIMENT FROM LEAVING THE PROJECT SITE. THIS INCLUDES THE INSTALLATION OF A CONSTRUCTION EXIT AND SILT FENCE AS NECESSARY. 9. THE CONTRACTOR IS REQUIRED TO MAINTAIN THE TPOES GENERAL PERMIT NO. TXR 150000 REQUIREMENTS FOR CONSTRUCTION SITES. 10. PERMANENT VEGETATION WILL BE ESTABLISHED ON THE DISTURBED AREAS AFTER CONSTRUCTION IS COMPLETE BY HYDROMULCHING AND SEEDING ALL DISTURBED AREAS. 11. EXTERIOR BUILDING AND SITE LIGHTING SHALL MEET THE STANDARDS OF SECTION 7.11 OF THE UNIFIED DEVELOPMENT ORDINANCE. THE LIGHT SOURCE SHALL NOT PROJECT BELOW AN OPAQUE HOUSING AND NO FIXTURE SHALL DIRECTLY PROJECT LIGHT HORIZONTALLY. FIXTURES WILL BE MOUNTED IN SUCH A MANNER THAT THE PROJECTED CONE OF LIGHT DOES -NOT CROSS ANY PROPERTY LINE. PLEASE NOTE THAT COMPLIANCE WITH THIS SECTION WILL BE VERIFIED AT THE TIME OF BUILDING PERMIT AND CERTIFICATE OF OCCUPANCY. 12. DRAINAGE INFORMATION AND DETAILS WILL BE PROVIDED ON THE DRAINAGE PLAN AND DRAINAGE REPORT. 13. LANDSCAPING AND IRRIGATION DESIGN & ANALYSIS WILL BE PROVIDED ON THE LANDSCAPE & IRRIGATION PLANS. THE IRRIGATION SYSTEM MUST BE APPROVED AND INSTALLED PRIOR TO CERTIFICATE OF OCCUPANT. 14. ALL RADII AND DISTANCES ARE MEASURED TO THE BACK OF CURB UNLESS OTHERWISE NOTED. 15. ALL PAVEMENT SHALL BE PER TYPICAL PAVEMENT SECTION. REFER TO PAVEMENT PLAN FOR PAVEMENT DEPTHS. 16. 100% COVERAGE OF GROUNDCOVER, DECORATIVE PAVING, DECORATIVE ROCK (NOT LOOSE), OR A PERENNIAL GRASS 1S REQUIRED IN PARKING LOT ISLANDS, SWALES AND DRAINAGE AREAS, THE PARKING LOT SETBACK, RIGHT-OF-WAYS, AND ADJACENT PROPERTY DISTURBED DURING CONSTRUCTION 17. DETENTION AND DRAINAGE FACILITIES SHALL BE CONSTRUCTED FIRST. 18. THE CONTRACTOR SHALL PROMPTLY NOTIFY THE ENGINEER OF ANY DISCREPANCIES IN THESE PLANS, DRAWINGS AND SPECIFICATIONS. 19. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO COMPLY WITH ALL STATE AND FEDERAL REGULATIONS REGARDING CONSTRUCTION ACTIVITIES NEAR ENERGIZED OVERHEAD POWER LINES. 20. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE PROTECTION OF ALL EXISTING UTILITIES OR SERVICE LINES THAT ARE CROSSED OR EXPOSED DURING CONSTRUCTION OPERATIONS. WHERE EXISTING UTILITIES OR SERVICE LINES ARE CUT, BROKEN, OR DAMAGED, THE CONTRACTOR SHALL REPAIR OR REPLACE THE UTILITIES OR SERVICE LINE WITH THE SAME TYPE OF MATERIAL AND CONSTRUCTION OR BETTER. THIS MATERIAL AND WORK SHALL BE AT THE CONTRACTOR'S OWN EXPENSE. 21.A COPY OF THE APPROVED CONSTRUCTION PLANS MUST BE KEPT ON SITE AT ALL TIMES THROUGHOUT THE ENTIRE CONSTRUCTION OF THE PROJECT. CONTRACTOR SHALL MAINTAIN A SET OF REDLINE DRAWINGS, RECORDING AS -BUILT CONDITIONS DURING CONSTRUCTION. 22. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO PAY FOR AND OBTAIN ALL REQUIRED PERMIT'S AND INSPECTION APPROVALS FOR ALL WORK SHOWN. 23. ANY ADJACENT PROPERTY AND RIGHT-OF-WAY DISTURBED DURING CONSTRUCTION WILL BE RETURNED TO THEIR EXISTING CONDITION OR BETTER. 24. THE CONTRACTOR SHALL NOT CREATE A DIRT NUISANCE OR SAFETY HAZARD IN ANY STREET OR DRIVEWAY. 25. ADEQUATE DRAINAGE SHALL BE MAINTAINED AT ALL TIMES DURING CONSTRUCTION AND ANY DRAINAGE DITCH OR STRUCTURE DISTURBED DURING CONSTRUCTION SHALL BE RESTORED TO EXISTING CONDITIONS OR BETTER. 26. THE CONTRACTOR AGREES TO REPAIR ANY DAMAGE TO THE PUBLIC RIGHT-OF-WAY IN ACCORDANCE WITH THE STANDARDS OF THE APPLICABLE REGULATORY AGENCY. 27. THE CONTRACTOR SHALL PROTECT ALL MONUMENTS, IRON PINS, AND PROPERTY CORNERS DURING CONSTRUCTION. 28. THE CONTRACTOR MUST PROVIDE CONSTRUCTION STAKING FROM THE INFORMATION PROVIDED ON THE PLANS AND DRAWINGS. 29. THE CONTRACTOR MAY OBTAIN AN ELECTRONIC COPY OF THESE PLANS FOR CONSTRUCTION PURPOSES. THE ELECTRONIC FILE AND INFORMATION GENERATED, BY SCHULTZ "ENGINEERING, LLC (SE), FOR THIS PROJECT IS CONSIDERED BY SE TO BE CONFIDENTIAL. WHEN ISSUED, ITS USE IS INTENDED SOLELY FOR THE INDIVIDUAL OR ENTITY TO WHICH IT IS ADDRESSED. PERMISSION 1S NOT GRANTED TO THE RECIPIENT FOR DISTRIBUTION OF THESE DOCUMENTS IN ANY FORM OR FASHION. THE RECIPIENT UNDERSTANDS THAT THIS DATA IS AUTHORIZED "AS IS" WITHOUT ANY WARRANTY AS TO IT PERFORMANCE, ACCURACY, FREEDOM FROM ERROR, OR AS TO ANY RESULTS GENERATED THROUGHOUT ITS USE. THE RECIPIENT ALSO UNDERSTANDS AND AGREES THAT SE, UPON RELEASE OF SUCH DATA, IS NO LONGER RESPONSIBLE FOR THEIR USE OR MODIFICATION. THE USER AND RECIPIENT OF THE ELECTRONIC DATA ACCEPTS FULL RESPONSIBILITY AND LIABILITY FOR ANY CONSEQUENCES ARISING OUT OF THEIR USE. EROSION CONTROL NOTES: 1. THE CONTRACTOR IS REQUIRED TO MAINTAIN THE TPDES GENERAL PERMIT NO. TXR 150000 REQUIREMENTS FOR CONSTRUCTION SITES. 2. EROSION CONTROL MEASURES SHOWN IN THESE PLANS SHALL BE CONSIDERED THE VERY MINIMUM REQUIRED. R SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO IMPLEMENT ALL OTHER EROSION CONTROL MEASURES (DIVERSION BERMS, DRAINAGE STRUCTURES, SWALES, ADDITIONAL FENCING, ETC...) NECESSARY TO KEEP THE EXISTING IMPROVEMENTS AND DEVELOPMENTS FROM DAMAGE OF ANY KIND, DURING ALL PHASES OF DEMOLITION AND CONSTRUCTION. 3. ALL SEDIMENT TRAPPING DEVICES SHALL BE INSTALLED AS SOON AS PRACTICAL AFTER THE AREA HAS BEEN DISTURBED. ALL SEDIMENT TRAPPING DEVICES SHALL BE CLEANED WHEN SEDIMENT LEVEL REACHES 25% CAPACITY. SEDIMENT SHALL BE DISPOSED OF BY SPREADING ON SITE OR HAULING AWAY IF NOT SUITABLE FOR FILL 4. EROSION CONTROL MEASURES SHALL BE IMPLEMENTED PRIOR TO ANY EXCAVATION OR DEMOLITION WORK. 5. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO USE WHATEVER MEANS NECESSARY TO MINIMIZE EROSION AND PREVENT SEDIMENT FROM LEAVING THE PROJECT STIE. THIS INCLUDES THE INSTALLATION OF A CONSTRUCTION EXIT AND SILT FENCE AS NECESSARY. 6. THE CONTRACTOR IS RESPONSIBLE FOR INSPECTING AND MAINTAINING THE EROSION AND SEDIMENT CONTROL DEVICES. INSPECTIONS SHALL BE DONE EVERY 14 DAYS AND AFTER EVERY RAINFALL EVENT OF 1/2" OR MORE. THE CONTRACTOR SHALL REMOVE ALL MUD DEPOSITED ON THE ADJACENT STREETS AS A RESULT OF THE CONSTRUCTION OF THIS PROJECT. 7. THE CONTRACTOR SHALL REMOVE THE EROSION CONTROL MEASURES ONCE GRASS IS ESTABLISHED. 8. INLET PROTECTION TO BE INSTALLED AT ALL PROPOSED AND EXISTING INLETS ADJACENT TO THE PROJECT SITE. 9. CONSTRUCTION EXIT IS TO BE DRESSED WITH ADDITIONAL ROCK AS NEEDED AND MAINTAINED SO AS TO PREVENT CONSTRUCTION TRAFFIC FROM TRACKING MUD ONTO ADJACENT PUBLIC STREETS. 10. ALL AREAS WHERE EXISTING VEGETATION AND GRASS COVER HAVE BEEN DISTURBED BY CONSTRUCTION SHALL BE ADEQUATELY HYDROMULCHED OR BLOCK SODDED, AND WATERED UNTIL GROWTH IS ESTABLISHED. ALL EROSION CONTROL MEASURES SHALL REMAIN IN PLACE UNTIL ACCEPTABLE VEGETATIVE GROWTH IS ESTABLISHED AFTER CONSTRUCTION IS COMPLETE AND THEN REMOVED BY CONTRACTOR. CASTLE ROCK AMENITY CENTER SPLASH PAD ADDITION CASTLE ROCK SUBDIVISION - PH 2B COMMON AREA (AMMENITY CENTER) - COLLEGE STATION, TX BENCHMARK INFORMATION TBM 1 N: 10189358.1277 E: 3574609.9387 ELEV : 281.87' (BACK OF CURB) �_---.JTE & EROSIO CONTROL PLA SITE SPECIFIC NOTES* 1. THE OWNER OF THE PROPERTY IS CASTLE ROCK HOMEOWNERS ASSOCIATION. INC. THE SUBJECT PROPERTY IS CASTLE ROCK SUBDIVISION, PHASE 28. PROPERTY IS ZONED PDD (PLANNED DEVELOPMENT DISTRICT). 2. THE TOTAL DISTURBED AREA FOR THIS PROJECT IS 0.103 ACRES (4501 SF). 3. THE SUBJECT TRACT DOES NOT UE WITHIN THE 100 YEAR FLOODPLAIN ACCORDING TO FEMA FLOOD INSURANCE RATE MAPS FOR BRAZOS COUNTY, TEXAS AND INCORPORATED AREAS. COMMUNITY NO. 480083, PANEL NO. 0325E, MAP NO. 48041CO325E, EFFECTIVE DATE: MAY 16, 2012. 4. CONTOURS SHOWN ARE FROM FIELD SURVEY DATA. S. ALL ELECTRICAL IMPROVEMENTS SHALL BE PER COLLEGE STATION U71LMES SPECIFICATIONS AND PER THE COLLEGE STATION UTILITIES ELECTRICAL DESIGN FOR THIS PROJECT. ELECTRIC PROJECT COORDINATOR CITY OF COLLEGE STATION UTILITIES 979-764-8314 6. THE SPLASH PAD SHALL BE A CLOSED PUMP AND FILTER SYSTEM WITH AN ISOLATION VALVE THAT CAN BE OPENED TO DISCHARGE WATER FROM THE CLOSED SYSTEM INTO THE SANITARY SEWER SERVICE UNE. THE ISOLATION VALVE SHALL REMAIN CLOSED TO PREVENT STORM WATER FROM ENTERING THE SANITARY SEWER SYSTEM. THE SPLASH PAD PUMP AND FILTER SYSTEM SHALL BE IN ACCORDANCE WITH THE 2012 IPC, WHERE INDIRECT WASTE WITH AN AIR GAP IS REQUIRED FOR SWIMMING POOLS, BACKWASH FILTERS SYSTEMS, POOL DECKS, AND SIMILAR APPLICATIONS, LIKE THE SPLASH PAD. SECTION 802.2.1 OF THE 2012 IPC STATES: "THE 'AIR GAP' BETWEEN INDIRECT WASTE PIPE AND THE FLOOD LEVEL RIM OF THE WASTE RECEPTOR SHALL BE NOT LESS THAN TWICE THE EFFECTIVE OPENING OF THE INDIRECT WASTE PIPE'. THE WASTE RECEPTOR (SANITARY SEWER SERVICE INLET) SHALL BE TRAPPED AND PROTECTED FROM RAINFALL VICINITY MAP PROJECT -\ LOCATION STATE HIGHWAY 40 -WILLIAM D. FITC14 PARKWAZ' 102 NOT TO LE STLE ROCK AMENITY CENTS 601 V WA3, 10 rj 2, S DI DI I TOTAL AREA = 0.654 ACRES CASTLE ROCK SUBDIVION - PHASE 2B COMMON AREA (AMMENITY CENTER) 9117/118 Mmlm 1 8TEVE48M SURVEY, A-54 COLI.EQE STATION, BRAZOS COUNTY, TEXAS SCALE: 1 "=20' MAY 2015 OWNER/DEVELOPER: CASTLE ROCK HOMEOWNERS ASSOCIATION, INC. P.Q. BOX 9748 COLLEGE STATION, TX 77845 SURVEYOR: BRAD KERR, RPLS NO. 4502 KERR SURVEYING, LLC 409 N. TEXAS AVENUE BRYAN, TX 77803 (979) 268-3195 ENGINEER: SCHULTZ ENGINEERING, LLC. PO BOX 11995 COLLEGE STATION, TX 77842 (979)764-3900 SCALE VERTICAL N/A HORIZONTAL V=20' PLOTTING SCALE: 1:1 FILE NAME: 15-384 SHEET Curve Table CURVE # LENGTH RADIUS DELTA TANGENT CHORD CHORD DIRECTION C11 80.84' 480.00' 009'38'59" 40.52' 80.75' S66'45'04'E C12 28.39' 25.00' 065'04'31" 15.95' 26.89' S82 49'45'W C13 246.32' 465.00' 030'21'05" 126.13' 243.45' N79'48'33"W VICINITY MAP PROJECT -\ LOCATION STATE HIGHWAY 40 -WILLIAM D. FITC14 PARKWAZ' 102 NOT TO LE STLE ROCK AMENITY CENTS 601 V WA3, 10 rj 2, S DI DI I TOTAL AREA = 0.654 ACRES CASTLE ROCK SUBDIVION - PHASE 2B COMMON AREA (AMMENITY CENTER) 9117/118 Mmlm 1 8TEVE48M SURVEY, A-54 COLI.EQE STATION, BRAZOS COUNTY, TEXAS SCALE: 1 "=20' MAY 2015 OWNER/DEVELOPER: CASTLE ROCK HOMEOWNERS ASSOCIATION, INC. P.Q. BOX 9748 COLLEGE STATION, TX 77845 SURVEYOR: BRAD KERR, RPLS NO. 4502 KERR SURVEYING, LLC 409 N. TEXAS AVENUE BRYAN, TX 77803 (979) 268-3195 ENGINEER: SCHULTZ ENGINEERING, LLC. PO BOX 11995 COLLEGE STATION, TX 77842 (979)764-3900 SCALE VERTICAL N/A HORIZONTAL V=20' PLOTTING SCALE: 1:1 FILE NAME: 15-384 SHEET \ LV 1 �•F7 �W-8 0.162 ACRES PARKLAND 9117/118 PARK AREA 4.363 ACRES PER PH 1A 8214/234 W-8 I rn I rn tn UE UE CASTLE ROCK PARKWAY 70' ROW - 38' B -B PAVEMENT WIDTH - U� e UE T i ::III MINE III Ill \ Q\f LO 20 10 0 20 SCALE IN FEET LOT 52 \ LOT 53 1 1 EXISTING CANOPY TREE TO BE REMOVED PROPOSED CANOPY TREE 3.5" CALIPER MINIMUM LANDSCAPE PLAN LANDSCAPE LEGEND EXISTING CANOPY TREE (BURR OAK) PROPOSED CANOPY TREE 0 (LIVE OAK) 3.5" CALIPER MIN. 0 EXISTING SHRUB (SEA GREEN JUNIPER) Q PROPOSED SHRUB (SEA GREEN JUNIPER) PROPOSED SHRUBS �1 W-8 PROPOSED CANOPY TREE 3.5" CALIPER MINIMUM w E THE SEAL APPEARING ON THIS ---~ DOCUMENT WAS AUTHORIZED BY %OO'ChaunitzEngin Q Q r i n g' OEEN L. DOYEN, VV VV 1 LLu LICENSE NO. 10983535 2730 Longmire, Suite A MAY 6, 2015. College Station, Texas 77845 ISSUED FOR REVIEW 979.764.3900 TBPE NO. 12327 SURVEYED DESIGNED DRAWN APPROVED JOB NO. DATE KERR DLD DLD JPS 15-384 MAY 2015 '* 1 • ••� DEVEN.L DOYEN ��s 109835 = R.', Lmlo FIRM # 12327 SCHULTZ ENGINEERING, LLC no GRADING PLAN CASTLE ROCK AMENITY CENTER SPLASH PAD ADDITION CASTLE ROCK SUBDIVISION - PH 2B COMMON AREA (AMMENITY CENTER) - COLLEGE STATION, TX LANDSCAPE & GRADING PLA_� GRADING NOTES! 1. FILL MATERIAL USED TO ACHIEVE GRADE IN AREAS TO RECEIVE PAVEMENT OR WITHIN THE STREET RIGHT-OF-WAY SHALL BE COMPACTED TO AT LEAST 989 OF THE MAXIMUM DRY DENSITY AS DETERMINED BY THE STANDARD PROCTOR TEST, (ASTM 0698). AT A MOISTURE CONTENT FROM OPTIMUM MOISTURE CONTENT TO 49 ABOVE THE OPTIMUM MOISTURE CONTENT. AREAS OUTSIDE OF THE STREET RIGHT-OF-WAY OR PAVEMENT AREAS SHALL BE COMPACTED TO 959 OF THE MAXIMUM DRY DENSITY. 2. THE SUBGRADE BENEATH THE CONCRETE SIDEWALKS SHALL BE 6' STABILIZED SUBGRADE OR SELECT FILL. 3. HANDICAP RAMP SLOPES SHALL NOT EXCEED 1V -12H. 4. THE TOPOGRAPHY SHOWN IS FROM FIELD SURVEY DATA. 5. STRUCTURAL BACKFILL FOR UTILITY OR STORM DRAIN TRENCHES IS REQUIRED WHENEVER THE TRENCH IS WITHIN 5' OF PAVEMENT OR SIDEWALK. 6. THE CONTRACTOR SHALL FOLLOW THE GENERAL INTENT OF THE GRADING PLANS. MINOR ADJUSTMENTS TO THE ACTUAL ELEVATIONS SHOWN ON THE GRADING PLAN MAY BE REQUIRED TO MATCH EXISTING GROUND ELEVATIONS AND STRUCTURES. THE PROPOSED CONTOUR LINES SHOWN ARE APPROXIMATE ONLY, THE DESIGN GRADE SPOT ELEVATIONS SHOULD BE USED FOR CONSTRUCTION OF THE SITE WORK. 7. THE CONTRACTOR SHALL SALVAGE ALL TOPSOIL AND REPLACE IT ON ALL DISTURBED AREAS. ALL PARKING LOT ISLANDS AND AREAS ADJACENT TO PARKING AND SIDEWALK AREAS SHALL RECEIVE 6" SANDY LOAM TOPSOIL PRIOR TO PLACEMENT OF GRASS SOD OR HYDROMULCH. 8. POSITIVE DRAINAGE AWAY FROM ALL SIDES OF THE PROPOSED BUILDING PAD SHALL BE PROVIDED. USE OF INTERCEPTOR DRAINAGE SWALES OR DRAINAGE PIPING SYSTEMS TO ROUTE STORMWATER AROUND AND NOT THROUGH THE BUILDING PAD AREA. 9. THE SELECT FILL FOR THE BUILDING FOUNDATION SHALL BE CONSTRUCTED IN ACCORDANCE WITH THE GEOTECHNICAL REPORT. 10. THE UPPER PORTION OF ALL UTILITY EXCAVATIONS SHOULD BE BACKFILLED WITH PROPERLY COMPACTED CLAY SOILS TO MINIMIZE INFILTRATION OF SURFACE WATER. A CLAY "PLUG' SHOULD BE PROVIDED IN THE TRENCH ON THE EXTERIOR OF THE BUILDING TO PREVENT WATER FROM GAINING ACCESS ALONG THE TRENCH TO THE SUBGRADE BENEATH THE STRUCTURE. THE PLUG SHALL EXTEND TWO FEET BEYOND THE PIPE FACE IN ALL DIRECTIONS, AND A MINIMUM OF TWO FEET THICK. 11. REFER TO THE GEOTECHNICAL REPORT FOR DETAILED SPECIFICATIONS ON SUBGRADE, PAVEMENT, FOUNDATIONS, ETC. 12. ALL UNPAVED AREAS SHALL BE ADEQUATELY GRADED TO DRAIN, SO THAT NO PONDING OCCURS. 13. FINISH GRADE ADJACENT TO CURBING OR SIDEWALK SHALL BE H" BELOW THE TOP OF CONCRETE AND 2" BELOW IN LANDSCAPING AREAS. 14. ADEQUATE DRAINAGE SHALL BE MAINTAINED AT ALL TIMES DURING CONSTRUCTION AND ANY DRAINAGE DITCH OR STRUCTURE DISTURBED DURING CONSTRUCTION SHALL BE RESTORED TO EXISTING CONDITIONS OR BETTER. 15. THE APPROVAL OF THESE PLANS IS NOT AN AUTHORIZATION TO GRADE ADJACENT PROPERTIES. WHEN FIELD CONDITIONS WARRANT OFF-SITE GRADING, PERMISSION MUST BE OBTAINED FROM THE AFFECTED PROPERTY OWNER(S). ANY ADJACENT PROPERTY AND RIGHT-OF-WAY DISTURBED DURING CONSTRUCTION WILL BE RETURNED TO THEIR EXISTING CONDITIONS OR BETTER. 16. THE DETENTION FACILITIES MUST BE CONSTRUCTED FIRST. 17. THE CONTRACTOR SHALL REFER TO THE STRUCTURAL ENGINEER'S PLANS FOR SPECIFICATIONS. PROCEDURES, AND REQUIREMENTS FOR THE BUILDING PAD. 18. EXISTING TREES, STUMPS, AND LARGE TREE SYSTEMS, SHALL BE GRUBBED AND REMOVED. VEGETATION SHALL BE REMOVED AND THE TOP 6-24 INCHES OF TOP SOIL AND SUB -GRADE BE STRIPPED FROM THE AREAS TO BE COVERED BY THE PROPOSED IMPROVEMENTS. 19. EXISTING DRAINAGE WAYS THAT ARE TO BE FILLED SHALL HAVE BENCHES EXCAVATED INTO THE SIDE WALLS OF THE CHANNEL PRIOR TO PLACEMENT OF FILL. BENCHES SHOULD BE AT LEAST 6 FEET IN WIDTH WITH ONE BENCH BEING PLACED VERTICALLY FOR EVERY 2 FEET OF CHANNEL DEPTH. 20. MATERIAL EXCAVATED ON SITE, EXCLUDING THE TOP 6-24 INCHES OF TOP SOIL, MAY USED AS A FILL MATERIAL, UNDER PAVEMENT AREAS ONLY, IF THE MATERIAL IS FREE FROM TRASH, LUMPS, CLODS, ORGANIC SUBSTANCE, & OTHER FOREIGN MATTER AND SUBGRADE PREPARATION FILL MATERIAL PLACEMENT UNDER BUILDINGS SHALL BE IN ACCORDANCE WITH THE GEOTECHNICAL REPORT. 21. STABILIZED MATERIAL OR FILL MATERIAL SHALL BE PLACED IN EIGHT INCH MAXIMUM LOOSE LIFTS, WITH EACH LIFT WETTED OR DRIED TO A MOISTURE CONTENT RANGE OF 09 TO +49 OF THE OPTIMUM MOISTURE CONTENT AND COMPACTED TO A UNIFORM DENSITY OF 989 '(FOR STABILIZED) AND 959 (FOR GENERAL FILL) OF THE MAXIMUM DRY DENSITY AS DETERMINED BY ASTM D698. TP - TOP OF PAVEMENT TC - TOP OF CURB TW - TOP OF WALK TB - TOP OF BERM TG - TOP OF GROUND TRW - TOP OF RETAINING WALL LEGEND 280__. PROPOSED CONTOUR — — 280 — — EXISTING CONTOUR PROPERTY BOUNDARY ADJACENT PROPERTY BOUNDARY III N — — LOT LINE \ —PROPERTY SETBACK — — PROPOSED PUBLIC UTILITY EASEMENT — — EXISTING PUBLIC UTILITY EASEMENT PROPOSED PUBLIC ACCESS EASEMENT EXISTING PUBLIC ACCESS EASEMENT PROPOSED LANDSCAPING 20 10 0 20 SCALE IN FEET LOT 52 \ LOT 53 1 1 EXISTING CANOPY TREE TO BE REMOVED PROPOSED CANOPY TREE 3.5" CALIPER MINIMUM LANDSCAPE PLAN LANDSCAPE LEGEND EXISTING CANOPY TREE (BURR OAK) PROPOSED CANOPY TREE 0 (LIVE OAK) 3.5" CALIPER MIN. 0 EXISTING SHRUB (SEA GREEN JUNIPER) Q PROPOSED SHRUB (SEA GREEN JUNIPER) PROPOSED SHRUBS �1 W-8 PROPOSED CANOPY TREE 3.5" CALIPER MINIMUM w E THE SEAL APPEARING ON THIS ---~ DOCUMENT WAS AUTHORIZED BY %OO'ChaunitzEngin Q Q r i n g' OEEN L. DOYEN, VV VV 1 LLu LICENSE NO. 10983535 2730 Longmire, Suite A MAY 6, 2015. College Station, Texas 77845 ISSUED FOR REVIEW 979.764.3900 TBPE NO. 12327 SURVEYED DESIGNED DRAWN APPROVED JOB NO. DATE KERR DLD DLD JPS 15-384 MAY 2015 '* 1 • ••� DEVEN.L DOYEN ��s 109835 = R.', Lmlo FIRM # 12327 SCHULTZ ENGINEERING, LLC no GRADING PLAN CASTLE ROCK AMENITY CENTER SPLASH PAD ADDITION CASTLE ROCK SUBDIVISION - PH 2B COMMON AREA (AMMENITY CENTER) - COLLEGE STATION, TX LANDSCAPE & GRADING PLA_� GRADING NOTES! 1. FILL MATERIAL USED TO ACHIEVE GRADE IN AREAS TO RECEIVE PAVEMENT OR WITHIN THE STREET RIGHT-OF-WAY SHALL BE COMPACTED TO AT LEAST 989 OF THE MAXIMUM DRY DENSITY AS DETERMINED BY THE STANDARD PROCTOR TEST, (ASTM 0698). AT A MOISTURE CONTENT FROM OPTIMUM MOISTURE CONTENT TO 49 ABOVE THE OPTIMUM MOISTURE CONTENT. AREAS OUTSIDE OF THE STREET RIGHT-OF-WAY OR PAVEMENT AREAS SHALL BE COMPACTED TO 959 OF THE MAXIMUM DRY DENSITY. 2. THE SUBGRADE BENEATH THE CONCRETE SIDEWALKS SHALL BE 6' STABILIZED SUBGRADE OR SELECT FILL. 3. HANDICAP RAMP SLOPES SHALL NOT EXCEED 1V -12H. 4. THE TOPOGRAPHY SHOWN IS FROM FIELD SURVEY DATA. 5. STRUCTURAL BACKFILL FOR UTILITY OR STORM DRAIN TRENCHES IS REQUIRED WHENEVER THE TRENCH IS WITHIN 5' OF PAVEMENT OR SIDEWALK. 6. THE CONTRACTOR SHALL FOLLOW THE GENERAL INTENT OF THE GRADING PLANS. MINOR ADJUSTMENTS TO THE ACTUAL ELEVATIONS SHOWN ON THE GRADING PLAN MAY BE REQUIRED TO MATCH EXISTING GROUND ELEVATIONS AND STRUCTURES. THE PROPOSED CONTOUR LINES SHOWN ARE APPROXIMATE ONLY, THE DESIGN GRADE SPOT ELEVATIONS SHOULD BE USED FOR CONSTRUCTION OF THE SITE WORK. 7. THE CONTRACTOR SHALL SALVAGE ALL TOPSOIL AND REPLACE IT ON ALL DISTURBED AREAS. ALL PARKING LOT ISLANDS AND AREAS ADJACENT TO PARKING AND SIDEWALK AREAS SHALL RECEIVE 6" SANDY LOAM TOPSOIL PRIOR TO PLACEMENT OF GRASS SOD OR HYDROMULCH. 8. POSITIVE DRAINAGE AWAY FROM ALL SIDES OF THE PROPOSED BUILDING PAD SHALL BE PROVIDED. USE OF INTERCEPTOR DRAINAGE SWALES OR DRAINAGE PIPING SYSTEMS TO ROUTE STORMWATER AROUND AND NOT THROUGH THE BUILDING PAD AREA. 9. THE SELECT FILL FOR THE BUILDING FOUNDATION SHALL BE CONSTRUCTED IN ACCORDANCE WITH THE GEOTECHNICAL REPORT. 10. THE UPPER PORTION OF ALL UTILITY EXCAVATIONS SHOULD BE BACKFILLED WITH PROPERLY COMPACTED CLAY SOILS TO MINIMIZE INFILTRATION OF SURFACE WATER. A CLAY "PLUG' SHOULD BE PROVIDED IN THE TRENCH ON THE EXTERIOR OF THE BUILDING TO PREVENT WATER FROM GAINING ACCESS ALONG THE TRENCH TO THE SUBGRADE BENEATH THE STRUCTURE. THE PLUG SHALL EXTEND TWO FEET BEYOND THE PIPE FACE IN ALL DIRECTIONS, AND A MINIMUM OF TWO FEET THICK. 11. REFER TO THE GEOTECHNICAL REPORT FOR DETAILED SPECIFICATIONS ON SUBGRADE, PAVEMENT, FOUNDATIONS, ETC. 12. ALL UNPAVED AREAS SHALL BE ADEQUATELY GRADED TO DRAIN, SO THAT NO PONDING OCCURS. 13. FINISH GRADE ADJACENT TO CURBING OR SIDEWALK SHALL BE H" BELOW THE TOP OF CONCRETE AND 2" BELOW IN LANDSCAPING AREAS. 14. ADEQUATE DRAINAGE SHALL BE MAINTAINED AT ALL TIMES DURING CONSTRUCTION AND ANY DRAINAGE DITCH OR STRUCTURE DISTURBED DURING CONSTRUCTION SHALL BE RESTORED TO EXISTING CONDITIONS OR BETTER. 15. THE APPROVAL OF THESE PLANS IS NOT AN AUTHORIZATION TO GRADE ADJACENT PROPERTIES. WHEN FIELD CONDITIONS WARRANT OFF-SITE GRADING, PERMISSION MUST BE OBTAINED FROM THE AFFECTED PROPERTY OWNER(S). ANY ADJACENT PROPERTY AND RIGHT-OF-WAY DISTURBED DURING CONSTRUCTION WILL BE RETURNED TO THEIR EXISTING CONDITIONS OR BETTER. 16. THE DETENTION FACILITIES MUST BE CONSTRUCTED FIRST. 17. THE CONTRACTOR SHALL REFER TO THE STRUCTURAL ENGINEER'S PLANS FOR SPECIFICATIONS. PROCEDURES, AND REQUIREMENTS FOR THE BUILDING PAD. 18. EXISTING TREES, STUMPS, AND LARGE TREE SYSTEMS, SHALL BE GRUBBED AND REMOVED. VEGETATION SHALL BE REMOVED AND THE TOP 6-24 INCHES OF TOP SOIL AND SUB -GRADE BE STRIPPED FROM THE AREAS TO BE COVERED BY THE PROPOSED IMPROVEMENTS. 19. EXISTING DRAINAGE WAYS THAT ARE TO BE FILLED SHALL HAVE BENCHES EXCAVATED INTO THE SIDE WALLS OF THE CHANNEL PRIOR TO PLACEMENT OF FILL. BENCHES SHOULD BE AT LEAST 6 FEET IN WIDTH WITH ONE BENCH BEING PLACED VERTICALLY FOR EVERY 2 FEET OF CHANNEL DEPTH. 20. MATERIAL EXCAVATED ON SITE, EXCLUDING THE TOP 6-24 INCHES OF TOP SOIL, MAY USED AS A FILL MATERIAL, UNDER PAVEMENT AREAS ONLY, IF THE MATERIAL IS FREE FROM TRASH, LUMPS, CLODS, ORGANIC SUBSTANCE, & OTHER FOREIGN MATTER AND SUBGRADE PREPARATION FILL MATERIAL PLACEMENT UNDER BUILDINGS SHALL BE IN ACCORDANCE WITH THE GEOTECHNICAL REPORT. 21. STABILIZED MATERIAL OR FILL MATERIAL SHALL BE PLACED IN EIGHT INCH MAXIMUM LOOSE LIFTS, WITH EACH LIFT WETTED OR DRIED TO A MOISTURE CONTENT RANGE OF 09 TO +49 OF THE OPTIMUM MOISTURE CONTENT AND COMPACTED TO A UNIFORM DENSITY OF 989 '(FOR STABILIZED) AND 959 (FOR GENERAL FILL) OF THE MAXIMUM DRY DENSITY AS DETERMINED BY ASTM D698. TP - TOP OF PAVEMENT TC - TOP OF CURB TW - TOP OF WALK TB - TOP OF BERM TG - TOP OF GROUND TRW - TOP OF RETAINING WALL LEGEND 280__. PROPOSED CONTOUR — — 280 — — EXISTING CONTOUR PROPERTY BOUNDARY ADJACENT PROPERTY BOUNDARY III RIGHT OF WAY — — LOT LINE — —PROPERTY SETBACK — — PROPOSED PUBLIC UTILITY EASEMENT — — EXISTING PUBLIC UTILITY EASEMENT PROPOSED PUBLIC ACCESS EASEMENT EXISTING PUBLIC ACCESS EASEMENT PROPOSED LANDSCAPING EXISTING LANDSCAPING LIMITS OF DISTURBANCE PROPOSED CURB AND GUTTER EXISTING CURB AND GUTTER —i FLOW ARROWS W-8 PROPOSED WATERLINE, SIZE NOTED W-8 EXISTING WATERLINE, SZE NOTED S-8 EXISTING SANITARY SEWER UNE. SIZE NOTED UE UE EXISTING UNDERGROUND ELECTRIC LINE SCALE VERTICAL 1�'=4' HORIZONTAL 111=40' PLOTTING SCALE: 1:1 FILE NAME: 1 S-qA4 SHEET 1+ a m h (s. PUE 8214/234 5' BUILDING SETBACK I 5' BUILDING SETBACK 0.162 ACRES PARKLAND LOT 50 LOT 51 EXISTING POOL AREA 0 % \ COMMON AREA (AMENITY CENTER) CASTLE ROCK PHASE 4 LOT 52 :XISTING ELECTRIC LINE LT FENCE LOT 53 8" DRAIN PIPE L -0- N t, 113 UE UE E UE0. !• EXISTING ELECTRIC LINE EXISTING BIKE K 4' SIDEWALK NITS OF ?� EQUIPMENT '� DISTURBANCE R PAD _ \ LOT 54 GRADE TO DRAIN EXISNG PARKING SPLASH PAD � �10' PUE 44 � 9117 118 a, O E TING-7- ING 6" SEWER NE 25' SETBACK PARK AREA �4 4.363 ACRES "' f PER PH 1A 1 8214/234 \ate ry�ti 4 SILT FENCE ---� " O \ COMMON AREA NO. 1 A IT--� \ 5' PUE 9117/118 .\WN __mss EXISTING $ WATER LINE W8 v \ws c� CASTLE ROCK PARKWAY 70' ROW - 38' B -B PAVEMENT WIDTH rn L 20 10 0 20 SCALE IN FEET w Y w y THIS DOCUMENT IS RELEASED FOR THE PURPOSE OF REVIEW ONLY UNDER THE AUTHORITY OF DEVEN L DOYEN P.E., LICENSE NO. 109835, ON APRIL 1, 2015. R IS NOT TO BE USED FOR BIDDING OR CONSTRUCTION PURPOSES. ELEVATION CERTIFICATE REQUIRED ■ ■ +29 ■ 4 REQUIRED 2'X4' WIRE MESH (OPTIONAL)-" �-SEDIMENT CONTROL FABRIC FASTENED TO T -POST OR 3 WOODEN STAKE LENGTH T -POST OR WOODEN STAKE DELTA TANGENT WITH OPTIONAL WIRE MESH w Y w y THIS DOCUMENT IS RELEASED FOR THE PURPOSE OF REVIEW ONLY UNDER THE AUTHORITY OF DEVEN L DOYEN P.E., LICENSE NO. 109835, ON APRIL 1, 2015. R IS NOT TO BE USED FOR BIDDING OR CONSTRUCTION PURPOSES. ELEVATION CERTIFICATE REQUIRED ■ ■ +29 ■ 4 REQUIRED 2'X4' WIRE MESH (OPTIONAL)-" �-SEDIMENT CONTROL FABRIC FASTENED TO T -POST OR FASTENED SECURELY TO WOODEN STAKE LENGTH T -POST OR WOODEN STAKE DELTA TANGENT WITH OPTIONAL WIRE MESH METAL T -POST OR WOODEN C11 8" OF FILTER FABRIC TO STAKE AS REQUIRED TO MAINTAIN. 009'38'59' EXTEND INTO A TRENCH SPACED 6' APART S6645'04"E AND BE ANCHORED WITH 28.39' 25.00' COMPACTED BACKFILL NATURAL GROUND ; DIRER F FLOW C13 246.32' „ 4"X4' MIN. TRENCH 126.13' 4• N79'48'33'W ALLOW 2.5' TO 5' AT TOE OF SLOPE FOR SEDIMENT 20' TO ACCUMULATE. ALIGN FENCE ALONG SLOPE I_- LI CONTOURS. SILT FENCE ASSEMBLY DETAIL N.T.S. GENERAL NOTES: 1. ALL CONSTRUCTION SHALL BE IN ACCORDANCE WITH THE LATEST CITY OF BRYAN/COLLEGE STATION STANDARD SPECIFICATIONS AND DETAILS FOR (WATER, SEWER, STREETS, DRAINAGE). ALL CONSTRUCTION SHALL BE COORDINATED WITH THE CITY ENGINEER'S OFFICE. 2. ALL UTILITY LINES (WATER, GAS, SANITARY SEWER, STORM SEWER, ETC. SHOWN ARE TAKEN FROM BEST AVAILABLE RECORD INFORMATION BASED ON CONSTRUCTION UTILITY MAP DOCUMENTS OBTAINED FROM CITY & INDEPENDENT AGENCIES AND/OR ABOVE GROUND FIELD EVIDENCE. SHOWN POSITIONS MAY NOT REPRESENT AS -BUILT CONDITIONS 3. THE CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING THE EXACT LOCATION OF ALL EXISTING UNDERGROUND UTILITIES. NOTIFICATION OF THE UTILITY COMPANIES 48 HOURS IN ADVANCE OF CONSTRUCTION IS REQUIRED. OIG TESS: (800) 344-8377 ATMOS ENERGY: (979) 774-2506 SUDDEN LINK COMMUNICATIONS: (979) 595-2429 VERIZON: (979) 821-4770 4. THE CONSTRUCTION SHALL COMPLY WITH OSHA STANDARD 29 CFR PART 1926 SUBPART P FOR TRENCH SAFETY REQUIREMENTS. S. BUILDING SETBACK SHALL BE IN ACCORDANCE WITH THE CITY OF COLLEGE STATION UNIFIED DEVELOPMENT ORDNANCE. 6. PROPOSED SIGNS SHALL BE PERMITTED SEPARATELY IN ACCORDANCE WITH THE UDO. 7. ALL ROOF AND GROUND -MOUNTED MECHANICAL EQUIPMENT SHALL BE SCREENED FROM VIEW OR ISOLATED SO AS NOT TO BE VISIBLE FROM ANY PUBLIC RIGHT-OF-WAY OR RESIDENTIAL DISTRICT WITHIN 150' OF THE SUBJECT PROPERTY, MEASURED FROM A POINT 5 FEET ABOVE GRADE. SUCH SCREENING SHALL BE COORDINATED WITH THE BUILDING ARCHITECTURE AND SCALE TO MAINTAIN A UNIFIED APPEARANCE. 8. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO USE WHATEVER MEANS NECESSARY TO MINIMIZE EROSION AND PREVENT SEDIMENT FROM LEAVING THE PROJECT SITE. THIS INCLUDES THE INSTALLATION OF A CONSTRUCTION EXIT AND SILT FENCE AS NECESSARY. 9. THE CONTRACTOR IS REQUIRED TO MAINTAIN THE TPOES GENERAL PERMIT NO. TXR 150000 REQUIREMENTS FOR CONSTRUCTION SITES. 10. PERMANENT VEGETATION WILL BE ESTABLISHED ON THE DISTURBED AREAS AFTER CONSTRUCTION IS COMPLETE BY HYDROMULCHING AND SEEDING ALL DISTURBED AREAS. 11. EXTERIOR BUILDING AND SITE LIGHTING SHALL MEET THE STANDARDS OF SECTION 7.11 OF THE UNIFIED DEVELOPMENT ORDINANCE. THE LIGHT SOURCE SHALL NOT PROJECT BELOW AN OPAQUE HOUSING AND NO FIXTURE SHALL DIRECTLY PROJECT LIGHT HORIZONTALLY. FIXTURES WILL BE MOUNTED IN SUCH A MANNER THAT THE PROJECTED CONE OF LIGHT DOES NOT CROSS ANY PROPERTY UNE. PLEASE NOTE THAT COMPLIANCE WITH THIS SECTION WILL BE VERIFIED AT THE TIME OF BUILDING PERMIT AND CERTIFICATE OF OCCUPANCY. 12. DRAINAGE INFORMATION AND DETAILS WILL BE PROVIDED ON THE DRAINAGE PLAN AND DRAINAGE REPORT. 13. LANDSCAPING AND IRRIGATION DESIGN & ANALYSIS WILL BE PROVIDED ON THE LANDSCAPE & IRRIGATION PLANS. THE IRRIGATION SYSTEM MUST BE APPROVED AND INSTALLED PRIOR TO CERTIFICATE OF OCCUPANT. 14. ALL RADII AND DISTANCES ARE MEASURED TO THE BACK OF CURB UNLESS OTHERWISE NOTED, 15. ALL PAVEMENT SHALL BE PER TYPICAL PAVEMENT SECTION. REFER TO PAVEMENT PLAN FOR PAVEMENT DEPTHS. 16. 100% COVERAGE OF GROUNDCOVER, DECORATIVE PAVING, DECORATIVE ROCK (NOT LOOSE), OR A PERENNIAL GRASS IS REQUIRED IN PARKING LOT ISLANDS, SWALES AND DRAINAGE AREAS, THE PARKING LOT SETBACK, RIGHT-OF-WAYS, AND ADJACENT PROPERTY DISTURBED DURING CONSTRUCTION 17. DETENTION AND DRAINAGE FACILITIES SHALL BE CONSTRUCTED FIRST. 18. THE CONTRACTOR SHALL PROMPTLY NOTIFY THE ENGINEER OF ANY DISCREPANCIES IN THESE PLANS, DRAWINGS AND SPECIFICATIONS. 19. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO COMPLY WITH ALL STATE AND FEDERAL REGULATIONS REGARDING CONSTRUCTION ACTIVITIES NEAR ENERGIZED OVERHEAD POWER LINES, 20. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE PROTECTION OF ALL EXISTING UTILITIES OR SERVICE LINES THAT ARE CROSSED OR EXPOSED DURING CONSTRUCTION OPERATIONS. WHERE EXISTING UTILITIES OR SERVICE LINES ARE CUT, BROKEN, OR DAMAGED, THE CONTRACTOR SHALL REPAIR OR REPLACE THE UTILITIES OR SERVICE LINE WITH THE SAME TYPE OF MATERIAL AND CONSTRUCTION OR BETTER. THIS MATERIAL AND WORK SHALL BE AT THE CONTRACTOR'S OWN EXPENSE. 21.A COPY OF THE APPROVED CONSTRUCTION PLANS MUST BE KEPT ON SITE AT ALL TIMES THROUGHOUT THE ENTIRE CONSTRUCTION OF THE PROJECT, CONTRACTOR SHALL MAINTAIN A SET OF REDLINE DRAWINGS, RECORDING AS -BUILT CONDITIONS DURING CONSTRUCTION. 22. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO PAY FOR AND OBTAIN ALL REQUIRED PERMITS AND INSPECTION APPROVALS FOR ALL WORK SHOWN. 23. ANY ADJACENT PROPERTY AND RIGHT-OF-WAY DISTURBED DURING CONSTRUCTION WILL BE RETURNED TO THEIR EXISTING CONDITION OR BETTER. 24. THE CONTRACTOR SHALL NOT CREATE A DIRT NUISANCE OR SAFETY HAZARD IN ANY STREET OR DRIVEWAY. 25. ADEQUATE DRAINAGE SHALL BE MAINTAINED AT ALL TIMES DURING CONSTRUCTION AND ANY DRAINAGE DITCH OR STRUCTURE DISTURBED DURING CONSTRUCTION SHALL BE RESTORED TO EXISTING CONDITIONS OR BETTER. 26. THE CONTRACTOR AGREES TO REPAIR ANY DAMAGE TO THE PUBLIC RIGHT-OF-WAY IN ACCORDANCE WITH THE STANDARDS OF THE APPLICABLE REGULATORY AGENCY. 27. THE CONTRACTOR SHALL PROTECT ALL MONUMENTS, IRON PINS, AND PROPERTY CORNERS DURING CONSTRUCTION. 28. THE CONTRACTOR MUST PROVIDE CONSTRUCTION STAKING FROM THE INFORMATION PROVIDED ON THE PLANS AND DRAWINGS. 29. THE CONTRACTOR MAY OBTAIN AN ELECTRONIC COPY OF THESE PLANS FOR CONSTRUCTION PURPOSES. THE ELECTRONIC FILE AND INFORMATION GENERATED, BY SCHULTZ-ENGINEERING, LLC (SE), FOR THIS PROJECT IS CONSIDERED BY SE TO BE CONFIDENTIAL. WHEN ISSUED, ITS USE IS INTENDED SOLELY FOR THE INDIVIDUAL OR ENTITY TO WHICH IT IS ADDRESSED. PERMISSION IS NOT GRANTED TO THE RECIPIENT FOR DISTRIBUTION OF THESE DOCUMENTS IN --ANY FORM OR FASHION. THE RECIPIENT UNDERSTANDS THAT THIS DATA IS AUTHORIZED "AS IS" WITHOUT ANY WARRANTY AS TO IT PERFORMANCE, ACCURACY, FREEDOM FROM ERROR, OR AS TO ANY RESULTS GENERATED THROUGHOUT ITS USE. THE RECIPIENT ALSO UNDERSTANDS AND AGREES THAT SE, UPON RELEASE OF SUCH DATA, IS NO LONGER RESPONSIBLE FOR THEIR USE OR MODIFICATION. THE USER AND RECIPIENT OF THE ELECTRONIC DATA ACCEPTS FULL RESPONSIBILITY AND LIABILITY FOR ANY CONSEQUENCES ARISING OUT OF THEIR USE. EROSION CONTROL NOTES: 1. THE CONTRACTOR IS REQUIRED TO MAINTAIN THE TPDES GENERAL PERMIT NO. TXR 150000 REQUIREMENTS FOR CONSTRUCTION SITES. 2. EROSION CONTROL MEASURES SHOWN IN THESE PLANS SHALL BE CONSIDERED THE VERY MINIMUM REQUIRED. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO IMPLEMENT ALL OTHER EROSION CONTROL MEASURES (DIVERSION BERMS, DRAINAGE STRUCTURES, SWALES, ADDITIONAL FENCING, ETC...) NECESSARY TO KEEP THE EXISTING IMPROVEMENTS AND DEVELOPMENTS FROM DAMAGE OF ANY KIND, DURING ALL PHASES OF DEMOLITION AND CONSTRUCTION. 3. ALL SEDIMENT TRAPPING DEVICES SHALL BE INSTALLED AS SOON AS PRACTICAL AFTER THE AREA HAS BEEN DISTURBED. ALL SEDIMENT TRAPPING DEVICES SHALL BE CLEANED WHEN SEDIMENT LEVEL REACHES 25% CAPACITY. SEDIMENT SHALL BE DISPOSED OF BY SPREADING ON SITE OR HAULING AWAY IF NOT SUITABLE FOR FILL. 4. EROSION CONTROL MEASURES SHALL BE IMPLEMENTED PRIOR TO ANY EXCAVATION OR DEMOLITION WORK. 5. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO USE WHATEVER MEANS NECESSARY TO MINIMIZE EROSION AND PREVENT SEDIMENT FROM LEAVING THE PROJECT SITE. THIS INCLUDES THE INSTALLATION OF A CONSTRUCTION EXIT AND SILT FENCE AS NECESSARY. 6. THE CONTRACTOR IS RESPONSIBLE FOR INSPECTING AND MAINTAINING THE EROSION AND SEDIMENT CONTROL DEVICES. INSPECTIONS SHALL BE DONE EVERY 14 DAYS AND AFTER EVERY RAINFALL EVENT OF 1/2' OR MORE. THE CONTRACTOR SHALL REMOVE ALL MUD DEPOSITED ON THE ADJACENT STREETS AS A RESULT OF THE CONSTRUCTION OF THIS PROJECT. 7. THE CONTRACTOR SHALL REMOVE THE EROSION CONTROL MEASURES ONCE GRASS IS ESTABLISHED. 8. INLET PROTECTION TO BE INSTALLED AT ALL PROPOSED AND EXISTING INLETS ADJACENT TO THE PROJECT SITE. 9. CONSTRUCTION EXIT IS TO BE DRESSED WITH ADDITIONAL ROCK AS NEEDED AND MAINTAINED SO AS TO PREVENT CONSTRUCTION TRAFFIC FROM TRACKING MUD ONTO ADJACENT PUBLIC STREETS. 10. ALL AREAS WHERE EXISTING VEGETATION AND GRASS COVER HAVE BEEN DISTURBED BY CONSTRUCTION SHALL BE ADEQUATELY HYDROMULCHED OR BLOCK SODDED, AND WATERED UNTIL GROWTH IS ESTABLISHED. ALL EROSION CONTROL MEASURES SHALL REMAIN IN PLACE UNTIL ACCEPTABLE VEGETATIVE GROWTH IS ESTABLISHED AFTER CONSTRUCTION IS COMPLETE AND THEN REMOVED BY CONTRACTOR. I CASTLE ROCK AMENITY CENTER 1 SPLASH PAD ADDITION CASTLE ROCK SUBDIVISION - PH 2B COMMON AREA (AMMENITY CENTER) -COLLEGE STATION, TX SITE SPECIFIC NOTES: 1. THE OWNER OF THE PROPERTY IS CASTLE ROCK HOMEOWNERS ASSOCIATION, INC. THE SUBJECT PROPERTY IS CASTLE ROCK SUBDIVISION, PHASE 28. PROPERTY IS ZONED PDD (PLANNED DEVELOPMENT DISTRICT). 2. THE TOTAL DISTURBED AREA FOR THIS PROJECT IS 0.103 ACRES (4501 SF). 3. THE SUBJECT TRACT DOES NOT UE WITHIN THE 100 YEAR FLOODPLAIN ACCORDING TO FEMA FLOOD INSURANCE RATE MAPS FOR BRAZOS COUNTY, TEXAS AND INCORPORATED AREAS. COMMUNITY NO. 480083, PANEL NO. 0325E, MAP NO. 4804100325E, EFFECTIVE DATE: MAY 16, 2012. 4. CONTOURS SHOWN ARE FROM FIELD SURVEY DATA. S. ALL ELECTRICAL IMPROVEMENTS SHALL BE PER COLLEGE STATION UTILITIES SPECIFICATIONS AND PER THE COLLEGE STATION UTILITIES ELECTRICAL DESIGN FOR THIS PROJECT. ELECTRIC PROJECT COORDINATOR CITY OF COLLEGE STATION UTILITIES 979-764-8314 RE,VtEVVE.f,) FOR CO ROANCE Mr 14 2015 COLLEGE STATION DEVELOPMENT SERVICES. PLAT FILED: CW EOIANC MAY 14 2015 * COLLEGE STATION ENGINEERING VICINITY MAP PROJECT 0 LOCATION WA CASTL STATE HIGHWAY 40 - W ILLTAIvl D.FIT PARKWAY SITE & EROSI* CONTROL PLA TOTAL AREA = 0.654 ACRES CASTLE ROCK SUBDIVION - PHASE 2B COMMON AREA (AMMENITY CENTER) 9117/118 RCSERT STEVENSON SURVEY, A-54 COLLEGE STATION, BWOS COUNTY, TEXAS SCALE: 1 "=20' APRIL 2015 0 i,NER/DEVELOPER: SURVEYOR: CAS LE ROCK HOMEOWNERS BRAD KERR, RPLS NO. 4502 A OCIATION, INC. KERR SURVEYING, LLC P.O.BOX 9748 409 N. TEXAS AVENUE CO GE STATION, TX 77845 BRYAN, TX 77803 (979) 268-3195 ENGINEER: SCHULTZ ENGINEERING, LLC. PO BOX 11995 COLLEGE STATION, TX 77842 (979)764-3900 SCALE VERTICAL N/A HORIZONTAL 1 "=20' PLOTTING SCALE: 1:1 FILE NAME: 15-384 SHEET Cl a i U 15•�I� 0°x • 02' IS 2:00 K -::s Curve Table CURVE # LENGTH RADIUS DELTA TANGENT CHORD CHORD DIRECTION C11 80.84' 480.00' 009'38'59' 40.52' 80.75' S6645'04"E C12 28.39' 25.00' 065'04'31' 15.95' 26.89' S82'49'45'W C13 246.32' 465.00' 030'21'05' 126.13' 243.45' N79'48'33'W RE,VtEVVE.f,) FOR CO ROANCE Mr 14 2015 COLLEGE STATION DEVELOPMENT SERVICES. PLAT FILED: CW EOIANC MAY 14 2015 * COLLEGE STATION ENGINEERING VICINITY MAP PROJECT 0 LOCATION WA CASTL STATE HIGHWAY 40 - W ILLTAIvl D.FIT PARKWAY SITE & EROSI* CONTROL PLA TOTAL AREA = 0.654 ACRES CASTLE ROCK SUBDIVION - PHASE 2B COMMON AREA (AMMENITY CENTER) 9117/118 RCSERT STEVENSON SURVEY, A-54 COLLEGE STATION, BWOS COUNTY, TEXAS SCALE: 1 "=20' APRIL 2015 0 i,NER/DEVELOPER: SURVEYOR: CAS LE ROCK HOMEOWNERS BRAD KERR, RPLS NO. 4502 A OCIATION, INC. KERR SURVEYING, LLC P.O.BOX 9748 409 N. TEXAS AVENUE CO GE STATION, TX 77845 BRYAN, TX 77803 (979) 268-3195 ENGINEER: SCHULTZ ENGINEERING, LLC. PO BOX 11995 COLLEGE STATION, TX 77842 (979)764-3900 SCALE VERTICAL N/A HORIZONTAL 1 "=20' PLOTTING SCALE: 1:1 FILE NAME: 15-384 SHEET Cl a i U 15•�I� 0°x • 02' IS 2:00 K -::s a LANDSCAPE PLAN - LANDSCAPE LEGEND `''' ' EXISTING CANOPY TREE (BURR OAK) PROPOSED CANOPY TREE 0 (LIVE OAK) 0 EXISTING SHRUB (SEA GREEN JUNIPER) 0 PROPOSED SHRUB (SEA GREEN JUNIPER) REVIEWED FOR COMPLIANCE MAY 14 2015 COLLEGE STATION DEVELVi-„'fL_Iv l ,.,EhvICES PLAT FILED: Schiulmltz Engineering, LLC% '70' 2730 Longmire, Suite A College Station, Texas 77845 979.764.3900 TBPE NO. 12327 SURVEYED DESIGNED I DRAWN I APPROVED I JOB NO. DATE KERR I DLD I DLD ( JPS ( 15-384 1 APRIL 2015 THIS DOCUMENT IS RELEASED FOR THE PURPOSE OF REVIEW ONLY UNDER THE AUTHORITY OF DEVEN L DOYEN P.E., LICENSE NO. 109835, ON APRIL 1. 2015. IT IS NOT TO BE USED FOR BIDDING OR CONSTRUCTION PURPOSES. GRADING PLAN CASTLE ROCK AMENITY CENTER SPLASH PAD ADDITION CASTLE ROCK SUBDIVISION - PH 2B COMMON AREA (AMMENITY CENTER) - COLLEGE STATION, TX LANDSCAPE & GRADIN -G PLAI� GRADING NOTES: 1. FILL MATERIAL USED TO ACHIEVE GRADE IN AREAS TO RECEIVE PAVEMENT OR WITHIN THE STREET RIGHT-OF-WAY SHALL BE COMPACTED TO AT LEAST 98% OF THE MAXIMUM DRY DENSITY AS DETERMINED BY THE STANDARD PROCTOR TEST, (ASTM 0698), AT A MOISTURE CONTENT FROM OPTIMUM MOISTURE CONTENT TO 49& ABOVE THE OPTIMUM MOISTURE CONTENT. AREAS OUTSIDE OF THE STREET RIGHT-OF-WAY OR PAVEMENT AREAS SHALL BE COMPACTED TO 952 OF THE MAXIMUM DRY DENSiIY. 2. THE SUBGRADE BENEATH THE CONCRETE SIDEWALKS SHALL BE 6” STABILIZED SUBGRADE OR SELECT FILL. 3. HANDICAP RAMP SLOPES SHALL NOT EXCEED 1V:12H. 4. THE TOPOGRAPHY SHOWN IS FROM FIELD SURVEY DATA. 5. STRUCTURAL BACKFILL FOR UTILITY OR STORM DRAIN TRENCHES IS REQUIRED WHENEVER THE TRENCH IS WITHIN 5' OF PAVEMENT OR SIDEWALK. 6. THE CONTRACTOR SHALL FOLLOW THE GENERAL INTENT OF THE GRADING PLANS. MINOR ADJUSTMENTS TO THE ACTUAL ELEVATIONS SHOWN ON THE GRADING PLAN MAY BE REQUIRED TO MATCH EXISTING GROUND ELEVATIONS AND STRUCTURES. THE PROPOSED CONTOUR LINES SHOWN ARE APPROXIMATE ONLY, THE DESIGN GRADE SPOT ELEVATIONS SHOULD BE USED FOR CONSTRUCTION OF THE SITE WORK. 7. THE CONTRACTOR SHALL SALVAGE ALL TOPSOIL AND REPLACE IT ON ALL DISTURBED AREAS. ALL PARKING LOT ISLANDS AND AREAS ADJACENT TO PARKING AND SIDEWALK AREAS SHALL RECEIVE 6" SANDY LOAM TOPSOIL PRIOR TO PLACEMENT OF GRASS SOD OR HYDROMULCH. 8. POSITIVE DRAINAGE AWAY FROM ALL SIDES OF THE PROPOSED BUILDING PAD SHALL BE PROVIDED. USE OF INTERCEPTOR DRAINAGE SWALES OR DRAINAGE PIPING SYSTEMS TO ROUTE STORMWATER AROUND AND NOT THROUGH THE BUILDING PAD AREA. 9. THE SELECT FILL FOR THE BUILDING FOUNDATION SHALL BE CONSTRUCTED IN ACCORDANCE WITH THE GEOTECHNICAL REPORT. 10. THE UPPER PORTION OF ALL UTILITY EXCAVATIONS SHOULD BE BACKFILLED WITH PROPERLY COMPACTED CLAY SOILS TO MINIMIZE INFILTRATION OF SURFACE WATER. A CLAY "PLUG" SHOULD BE PROVIDED IN THE TRENCH ON THE EXTERIOR OF THE BUILDING TO PREVENT WATER FROM GAINING ACCESS ALONG THE TRENCH TO THE SUBGRADE BENEATH THE STRUCTURE. THE PLUG SHALL EXTEND TWO FEET BEYOND THE PIPE FACE IN ALL DIRECTIONS, AND A MINIMUM OF TWO FEET THICK. 11. REFER TO THE GEOTECHNICAL REPORT FOR DETAILED SPECIFICATIONS ON SUBGRADE, PAVEMENT, FOUNDATIONS, ETC. 12. ALL UNPAVED AREAS SHALL BE ADEQUATELY GRADED TO DRAIN, SO THAT NO PONDING OCCURS. 13. FINISH GRADE ADJACENT TO CURBING OR SIDEWALK SHALL BE M" BELOW THE TOP OF CONCRETE AND 2" BELOW IN LANDSCAPING AREAS. 14. ADEQUATE DRAINAGE SHALL BE MAINTAINED AT ALL TIMES DURING CONSTRUCTION AND ANY DRAINAGE DITCH OR STRUCTURE DISTURBED DURING CONSTRUCTION SHALL BE RESTORED TO EXISTING CONDITIONS OR BETTER. 15. THE APPROVAL OF THESE PLANS IS NOT AN AUTHORIZATION TO GRADE ADJACENT PROPERTIES. WHEN FIELD CONDITIONS WARRANT OFF-SITE GRADING, PERMISSION MUST BE OBTAINED FROM THE AFFECTED PROPERTY OWNER(S). ANY ADJACENT PROPERTY AND RIGHT-OF-WAY DISTURBED DURING CONSTRUCTION WILL BE RETURNED TO THEIR EXISTING CONDITIONS OR BETTER. 16. THE DETENTION FACILITIES MUST BE CONSTRUCTED FIRST. 17. THE CONTRACTOR SHALL REFER TO THE STRUCTURAL ENGINEER'S PLANS FOR SPECIFICATIONS. PROCEDURES, AND REQUIREMENTS FOR THE BUILDING PAD. 18. EXISTING TREES, STUMPS, AND LARGE TREE SYSTEMS, SHALL BE GRUBBED AND REMOVED. VEGETATION SHALL BE REMOVED AND THE TOP 6-24 INCHES OF TOP SOIL AND SUB -GRADE BE STRIPPED FROM THE AREAS TO BE COVERED BY THE PROPOSED IMPROVEMENTS. 19. EXISTING DRAINAGE WAYS THAT ARE TO BE FILLED SHALL HAVE BENCHES EXCAVATED INTO THE SIDE WALLS OF THE CHANNEL PRIOR TO PLACEMENT OF FILL. BENCHES SHOULD BE AT LEAST 6 FEET IN WIDTH WITH ONE BENCH BEING PLACED VERTICALLY FOR EVERY 2 FEET OF CHANNEL DEPTH. 20. MATERIAL EXCAVATED ON SITE, EXCLUDING THE TOP 6-24 INCHES OF TOP SOIL, MAY USED AS A FILL MATERIAL, UNDER PAVEMENT AREAS ONLY. IF THE MATERIAL IS FREE FROM TRASH, LUMPS, CLODS, ORGANIC SUBSTANCE, & OTHER FOREIGN MATTER AND SUBGRADE PREPARATION FILL MATERIAL PLACEMENT UNDER BUILDINGS SHALL BE IN ACCORDANCE WITH THE GEOTECHNICAL REPORT. 21. STABILIZED MATERIAL OR FILL MATERIAL SHALL BE PLACED IN EIGHT INCH MAXIMUM LOOSE LIFTS, WITH EACH UFT WETTED OR DRIED TO A MOISTURE CONTENT RANGE OF OX TO +4% OF THE OPTIMUM MOISTURE CONTENT AND COMPACTED TO A UNIFORM DENSITY OF 98% (FOR STABILIZED) AND 95% (FOR GENERAL FILL) OF THE MAXIMUM DRY DENSITY AS DETERMINED BY ASTM D698. TP - TOP OF PAVEMENT TC - TOP OF CURB TW - TOP OF WALK TS - TOP OF BERM TG - TOP OF GROUND TRW - TOP OF RETAINING WALL LEGEND 280 PROPOSED CONTOUR — 280 — — EXISTING CONTOUR PROPERTY BOUNDARY ADJACENT PROPERTY BOUNDARY RIGHT OF WAY LOT UNE — —PROPERTY SETBACK — PROPOSED PUBLIC UTILITY EASEMENT — EXISTING PUBLIC UTILITY EASEMENT PROPOSED PUBLIC ACCESS EASEMENT EXISTING PUBLIC ACCESS EASEMENT PROPOSED LANDSCAPING EXISTING LANDSCAPING LIMITS OF DISTURBANCE PROPOSED CURB AND GUTTER EXISTING CURB AND GUTTER —i --� FLOW ARROWS W-8 PROPOSED WATERLINE, SIZE NOTED W-8 EXISTING WATERLINE, SIZE NOTED S-8 EXISTING SANITARY SEWER UNE, SIZE NOTED UE UE EXISTING UNDERGROUND ELECTRIC UNE REVIEWED7CE COMPLIA MAY '1 4 20 COLLEGE NATION ENGINEEFiiNG SCALE VERTICAL 1 "=4' HORIZONTAL 1 "=40' PLOTTING SCALE: 1:1 FILE NAME: 15-384 SHEET • R. G1 a� PROJECT O LOCATION CASTL oCK ARKW A STATE HIGHWAY, 40 - WILLIAM D. FITCHPARKWAY il 0 4 N NOT TO SCALE OWNER/DEVELOPER: CASTLE ROCK HOMEOWNERS ASSOCIATION; INC. P.O. BOX 9748 COLLEGE STATION, TX 77845 SPLAS11 PAD ADDITION Im THIS DOCUMENT IS RELEASED FOR THE PURPOSE OF REVIEW ONLY UNDER THE AUTHORITY OF DEVEN L. DOYEN P.E., LICENSE NO. 109835, ON APRIL 1, 2015. IT IS NOT TO BE USED FOR BIDDING OR CONSTRUCTION PURPOSES. SCHEDULE SH EET TITLE Cl SITE & EROSION CONTROL PLAN C2 LANDSCAPE & GRADING PLAN F SHEETS p4 • b2.• 15 2:00 pa UA,J I -Lr. ICV U& YA1CiL W A Y 70' ROW - 38' B -B PAVEMENT WIDTH Lchulmitz Engineering, 2730 Longmire, Suite A College Station, Texas 77845 / y co y 1 --- 979.764.3900 TBPE NO. 12327 _ SURVEYED I DESIGNED I DRAWN APPROVED JOB NO. DATE ' KERR I DLD I DLD I JPS 1 15-384 1 APRIL 2015 THIS DOCUMENT IS RELEASED FOR THE PURPOSE OF REVIEW ONLY UNDER THE AUTHORITY OF DEVEN L DOYEN P.E., LICENSE NO. 109835, ON APRIL 1, 2015. IT IS NOT TO BE USED FOR BIDDING OR CONSTRUCTION PURPOSES. 20 10 0 20 SCALE IN FEET 2'X4' WIRE MESH (OPTIONAL) FASTENED TO T -POST OR WOODEN STAKE METAL T -POST OR WOODEN STAKE AS REQUIRED TO MAINTAIN. SPACED 6' APART NATURAL 4'X4' MIN. SEDIMENT CONTROL FABRIC FASTENED SECURELY TO T -POST OR WOODEN STAKE WITH OPTIONAL WIRE MESH 8" OF FILTER FABRIC TO EXTEND INTO A TRENCH AND BE ANCHORED WITH COMPACTED BACKFILL OIRE�� F FLOW 1 `-ALLOW 2.5' TO 5' AT TOE OF SLOPE FOR SEDIMENT 20' TO ACCUMULATE. ALIGN Z FENCE ALONG SLOPE CONTOURS. SILT FENCE ASSEMBLY DETAIL N.T.S. GENERAL NOTES: 1. ALL CONSTRUCTION SHALL BE IN ACCORDANCE WITH THE LATEST CITY OF BRYAN/COLLEGE STATION STANDARD SPECIFICATIONS AND DETAILS FOR (WATER, SEWER, STREETS, DRAINAGE). ALL CONSTRUCTION SHALL BE COORDINATED WITH THE CITY ENGINEER'S OFFICE. 2. ALL UTILITY LINES (WATER, GAS, SANITARY SEWER, STORM SEWER, ETC.) SHOWN ARE TAKEN FROM BEST AVAILABLE RECORD INFORMATION BASED ON CONSTRUCTION UTILITY MAP DOCUMENTS OBTAINED FROM CITY & INDEPENDENT AGENCIES AND/OR ABOVE GROUND FIELD EVIDENCE. SHOWN POSITIONS MAY NOT REPRESENT AS -BUILT CONDITIONS 3. THE CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING THE EXACT LOCATION OF ALL EXISTING UNDERGROUND UTILITIES. NOTIFICATION OF THE UTILITY COMPANIES 48 HOURS IN ADVANCE OF CONSTRUCTION IS REQUIRED. DIG TESS: (800) 344-8377 ATMOS ENERGY: (979) 774-2506 SUDDEN LINK COMMUNICATIONS: (979) 595-2429 VERIZON: (979) 821-4770 4. THE CONSTRUCTION SHALL COMPLY WITH OSHA STANDARD 29 CFR PART 1926 SUBPART P FOR TRENCH SAFETY REQUIREMENTS. S. BUILDING SETBACK SHALL BE IN ACCORDANCE WITH THE CITY OF COLLEGE STATION UNIFIED DEVELOPMENT ORDNANCE. 6. PROPOSED SIGNS SHALL BE PERMITTED SEPARATELY IN ACCORDANCE WITH THE UDO. 7. ALL ROOF AND GROUND -MOUNTED MECHANICAL EQUIPMENT SHALL BE SCREENED FROM VIEW OR ISOLATED SO AS NOT TO BE VISIBLE FROM ANY PUBLIC RIGHT-OF-WAY OR RESIDENTIAL DISTRICT WITHIN 150' OF THE SUBJECT PROPERTY, MEASURED FROM A POINT 5 FEET ABOVE GRADE, SUCH SCREENING SHALL BE COORDINATED WITH THE BUILDING ARCHITECTURE AND SCALE TO MAINTAIN _ A UNIFIED APPEARANCE. 8. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO USE WHATEVER MEANS NECESSARY TO MINIMIZE EROSION AND PREVENT SEDIMENT FROM LEAVING THE PROJECT SITE. THIS INCLUDES THE INSTALLATION OF A CONSTRUCTION EXIT AND SILT FENCE AS NECESSARY. 9. THE CONTRACTOR IS REQUIRED TO MAINTAIN THE TPDES GENERAL PERMIT NO. TXR 150000 REQUIREMENTS FOR CONSTRUCTION SITES. 10. PERMANENT VEGETATION WILL BE ESTABLISHED ON THE DISTURBED AREAS AFTER CONSTRUCTION IS COMPLETE BY HYDROMULCHING AND SEEDING ALL DISTURBED AREAS. 11. EXTERIOR BUILDING AND SITE LIGHTING SHALL MEET THE STANDARDS OF SECTION 7.11 OF THE UNIFIED DEVELOPMENT ORDINANCE. THE LIGHT SOURCE SHALL NOT PROJECT BELOW AN OPAQUE HOUSING AND NO FIXTURE SHALL DIRECTLY PROJECT LIGHT HORIZONTALLY. FIXTURES WILL BE MOUNTED IN SUCH A MANNER THAT THE PROJECTED CONE OF LIGHT DOES NOT CROSS ANY PROPERTY LINE. PLEASE NOTE THAT COMPLIANCE WITH THIS SECTION WILL BE VERIFIED AT THE TIME OF BUILDING PERMIT AND CERTIFICATE OF OCCUPANCY. 12. DRAINAGE INFORMATION AND DETAILS WILL BE PROVIDED ON THE DRAINAGE PLAN AND DRAINAGE REPORT. 13. LANDSCAPING AND IRRIGATION DESIGN & ANALYSIS WILL BE PROVIDED ON THE LANDSCAPE & IRRIGATION PLANS. THE IRRIGATION SYSTEM MUST BE APPROVED AND INSTALLED PRIOR TO CERTIFICATE OF OCCUPANT. 14. ALL RADII AND DISTANCES ARE MEASURED TO THE BACK OF CURB UNLESS OTHERWISE NOTED. 15. ALL PAVEMENT SHALL BE PER TYPICAL PAVEMENT SECTION. REFER TO PAVEMENT PLAN FOR PAVEMENT DEPTHS. 16. 100% COVERAGE OF GROUNDCOVER, DECORATIVE PAVING, DECORATIVE ROCK (NOT LOOSE), OR A PERENNIAL GRASS IS REQUIRED IN PARKING LOT ISLANDS, SWALES AND DRAINAGE AREAS, THE PARKING LOT SETBACK, RIGHT-OF-WAYS, AND ADJACENT PROPERTY DISTURBED DURING CONSTRUCTION 17. DETENTION AND DRAINAGE FACILITIES SHALL BE CONSTRUCTED FIRST. 18. THE CONTRACTOR SHALL PROMPTLY NOTIFY THE ENGINEER OF ANY DISCREPANCIES IN THESE PLANS, DRAWINGS AND SPECIFICATIONS. 19. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO COMPLY WITH ALL STATE AND FEDERAL REGULATIONS REGARDING CONSTRUCTION ACTIVITIES NEAR ENERGIZED OVERHEAD POWER LINES. 20. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE PROTECTION OF ALL EXISTING UTILITIES OR SERVICE LINES THAT ARE CROSSED OR EXPOSED DURING CONSTRUCTION OPERATIONS. WHERE EXISTING UTILITIES OR SERVICE LINES ARE CUT, BROKEN, OR DAMAGED, THE CONTRACTOR SHALL REPAIR OR REPLACE THE UTILITIES OR SERVICE UNE WITH THE SAME TYPE OF MATERIAL AND CONSTRUCTION OR BITTER. THIS MATERIAL AND WORK SHALL BE AT THE CONTRACTOR'S OWN EXPENSE. 21.A COPY OF THE APPROVED CONSTRUCTION PLANS MUST BE KEPT ON SITE AT ALL TIMES THROUGHOUT THE ENTIRE CONSTRUCTION OF THE PROJECT. CONTRACTOR SHALL MAINTAIN A SET OF REDLINE DRAWINGS, RECORDING AS -BUILT CONDITIONS DURING CONSTRUCTION. 22. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO PAY FOR AND OBTAIN ALL REQUIRED PERMITS AND INSPECTION APPROVALS FOR ALL WORK SHOWN. 23. ANY ADJACENT PROPERTY AND RIGHT-OF-WAY DISTURBED DURING CONSTRUCTION WILL BE RETURNED TO THEIR EXISTING CONDITION OR BETTER. 24. THE CONTRACTOR SHALL NOT CREATE A DIRT NUISANCE OR SAFETY HAZARD IN ANY STREET OR DRIVEWAY. 25. ADEQUATE DRAINAGE SHALL BE MAINTAINED AT ALL TIMES DURING CONSTRUCTION AND ANY DRAINAGE DITCH OR STRUCTURE DISTURBED DURING CONSTRUCTION SHALL BE RESTORED TO EXISTING CONDITIONS OR BETTER. 26. THE CONTRACTOR AGREES TO REPAIR ANY DAMAGE TO THE PUBLIC RIGHT-OF-WAY IN ACCORDANCE WITH THE STANDARDS OF THE APPLICABLE REGULATORY AGENCY. 27. THE CONTRACTOR SHALL PROTECT ALL MONUMENTS, IRON PINS, AND PROPERTY CORNERS DURING CONSTRUCTION. 28. THE CONTRACTOR MUST PROVIDE CONSTRUCTION STAKING FROM THE INFORMATION PROVIDED ON THE PLANS AND DRAWINGS. 29. THE CONTRACTOR MAY OBTAIN AN ELECTRONIC COPY OF THESE PLANS FOR CONSTRUCTION PURPOSES. THE ELECTRONIC FILE AND INFORMATION GENERATED, BY SCHULTZ ENGINEERING, LLC (SE), FOR THIS PROJECT IS CONSIDERED BY SE TO BE CONFIDENTIAL. WHEN ISSUED, IT'S USE IS INTENDED SOLELY FOR THE INDIVIDUAL OR ENTITY TO WHICH IT IS ADDRESSED. PERMISSION IS NOT GRANTED TO THE RECIPIENT FOR DISTRIBUTION OF THESE DOCUMENTS IN ANY FORM OR FASHION. THE RECIPIENT UNDERSTANDS THAT THIS DATA IS AUTHORIZED "AS IS WITHOUT ANY WARRANTY AS TO IT PERFORMANCE. ACCURACY, FREEDOM FROM ERROR, OR TO ANY RESULTS GENERATED THROUGHOUT ITS USE. THE RECIPIENT ALSO UNDERSTANDS AND AGREES THAT SE, UPON RELEASE OF SUCH DATA, IS NO LONGER RESPONSIBLE FOR THEIR USE OR MODIFICATION. THE USER AND RECIPIENT OF THE ELECTRONIC DATA ACCEPTS FULL RESPONSIBILITY AND LIABILITY FOR ANY CONSEQUENCES ARISING OUT OF THEIR USE. EROSION CONTROL NOTES: 1. THE CONTRACTOR IS REQUIRED TO MAINTAIN THE TPOES GENERAL PERMIT NO. TXR 150000 REQUIREMENTS FOR CONSTRUCTION SITES. 2. EROSION CONTROL MEASURES SHOWN IN THESE PLANS SHALL BE CONSIDERED THE VERY MINIMUM REQUIRED. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO IMPLEMENT ALL OTHER EROSION CONTROL MEASURES (DIVERSION BERMS, DRAINAGE STRUCTURES, SWALES, ADDITIONAL FENCING, ETC...) NECESSARY TO KEEP THE EXISTING IMPROVEMENTS AND DEVELOPMENTS FROM DAMAGE OF ANY KIND, DURING ALL PHASES OF DEMOLITION AND CONSTRUCTION. 3. ALL SEDIMENT TRAPPING DEVICES SHALL BE INSTALLED AS SOON AS PRACTICAL AFTER THE AREA HAS BEEN DISTURBED. ALL SEDIMENT TRAPPING DEVICES SHALL BE CLEANED WHEN SEDIMENT LEVEL REACHES 25% CAPACITY. SEDIMENT SHALL BE DISPOSED OF BY SPREADING ON SITE OR HAULING AWAY IF NOT SUITABLE FOR FILL. 4. EROSION CONTROL MEASURES SHALL BE IMPLEMENTED PRIOR TO ANY EXCAVATION OR DEMOLITION WORK. . 5. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO USE WHATEVER MEANS NECESSARY TO MINIMIZE EROSION AND PREVENT SEDIMENT FROM LEAVING THE PROJECT SITE. THIS INCLUDES THE INSTALLATION OF A CONSTRUCTION EXIT AND SILT FENCE AS NECESSARY. 6. THE CONTRACTOR IS RESPONSIBLE FOR INSPECTING AND MAINTAINING THE EROSION AND SEDIMENT CONTROL DEVICES. INSPECTIONS SHALL BE DONE EVERY 14 DAYS AND AFTER EVERY RAINFALL EVENT OF 1/2- OR MORE. THE CONTRACTOR SHALL REMOVE ALL MUD DEPOSITED ON THE ADJACENT STREETS AS A RESULT OF THE CONSTRUCTION OF THIS PROJECT. 7. THE CONTRACTOR SHALL REMOVE THE EROSION CONTROL MEASURES ONCE GRASS IS ESTABLISHED. 8. INLET PROTECTION TO BE INSTALLED AT ALL PROPOSED AND EXISTING INLETS ADJACENT TO THE PROJECT SITE. 9. CONSTRUCTION EXIT IS TO BE DRESSED WITH ADDITIONAL ROCK AS NEEDED AND MAINTAINED SO AS TO PREVENT CONSTRUCTION TRAFFIC FROM TRACKING MUD ONTO ADJACENT PUBLIC STREETS. 10. ALL AREAS WHERE EXISTING VEGETATION AND GRASS COVER HAVE BEEN DISTURBED BY CONSTRUCTION SHALL BE ADEQUATELY HYDROMULCHED OR BLOCK SODDED, AND WATERED UNTIL GROWTH IS ESTABLISHED. ALL EROSION CONTROL MEASURES SHALL REMAIN IN PLACE UNTIL ACCEPTABLE VEGETATIVE GROWTH IS ESTABLISHED AFTER CONSTRUCTION IS COMPLETE AND THEN REMOVED BY CONTRACTOR. CASTLE ROCK AMENITY CENTER SPLASH PAD ADDITION CASTLE ROCK SUBDIVISION - PH 2B COMMON AREA (AMMENITY CENTER) - COLLEGE STATION, TX SITE SPECIFIC NOTES: 1. THE OWNER OF THE PROPERTY IS CASTLE ROCK HOMEOWNERS ASSOCIATION, INC. THE SUBJECT PROPERTY IS CASTLE ROCK SUBDIVISION, PHASE 2B. PROPERTY IS ZONED PDD (PLANNED DEVELOPMENT DISTRICT). 2. THE TOTAL DISTURBED AREA FOR THIS PROJECT IS 0.103 ACRES (4501 SF). 3. THE SUBJECT TRACT DOES NOT UE WITHIN THE 100 YEAR FLOODPLAIN ACCORDING TO FEMA FLOOD INSURANCE RATE MAPS FOR BRAZOS COUNTY, TEXAS AND INCORPORATED AREAS. COMMUNITY NO. 480083, PANEL NO. 0325E, MAP NO. 48041CO325E, EFFECTIVE DATE. MAY 16, 2012. 4. CONTOURS SHOWN ARE FROM FIELD SURVEY DATA. S. ALL ELECTRICAL IMPROVEMENTS SHALL BE PER COLLEGE STATION UTILITIES SPECIFICATIONS AND PER THE COLLEGE STATION UTILITIES ELECTRICAL DESIGN FOR THIS PROJECT. ELECTRIC PROJECT COORDINATOR CITY OF COLLEGE STATION UTILITIES 979-764-8314 VICINITY MAP PROJECT LOCATION ANVA�� 74 1 STATE HIGHWAY 40 - WILL D. FITCH PARKWAY NOT TO STLE ROCK AMENITY CE mm�"" ADD • TOTAL AREA = 0.654 ACRES CASTLE ROCK SUMMON -PHASE 2B COMMON AREA (AMMENITY CENTER) 9117/118 ROsR'P STF mSON SURVEY, A-54 COUECE STATION, BWOS COUNTY, TEXAS SCALE: 1 "=20' APRIL 2015 WNER/DEVELOPER: STLE ROCK HOMEOWNERS SOCIATION, INC. ). BOX 9748 LLEGE STATION, TX 77845 SURVEYOR: BRAD KERR, RPLS NO. 4502 KERR SURVEYING, LLC 409 N. TEXAS AVENUE BRYAN, TX 77803 (979) 268-3195 ENGINEER: SCHULTZ ENGINEERING, LLC. PO BOX 11995 COLLEGE STATION, TX 77842 (979)764-3900 e SCALE VERTICAL N/A HORIZONTAL 111=20' PLOTTING SCALE: 1:1 FILE NAME: 15-384 SHEET I m I Curve Table CURVE / LENGTH RADIUS DELTA TANGENT CHORD CHORD DIRECTION C11 80.84' 480.00' 009'38'59' 40.52' 80.75' S6645'04"E C12 28.39' 25.00' 065'04'31" 15.95' 26.89' S82'49'45'W C13 246.32' 465.00' 030'21'05' 126.13' 243.45' N79'48'33W VICINITY MAP PROJECT LOCATION ANVA�� 74 1 STATE HIGHWAY 40 - WILL D. FITCH PARKWAY NOT TO STLE ROCK AMENITY CE mm�"" ADD • TOTAL AREA = 0.654 ACRES CASTLE ROCK SUMMON -PHASE 2B COMMON AREA (AMMENITY CENTER) 9117/118 ROsR'P STF mSON SURVEY, A-54 COUECE STATION, BWOS COUNTY, TEXAS SCALE: 1 "=20' APRIL 2015 WNER/DEVELOPER: STLE ROCK HOMEOWNERS SOCIATION, INC. ). BOX 9748 LLEGE STATION, TX 77845 SURVEYOR: BRAD KERR, RPLS NO. 4502 KERR SURVEYING, LLC 409 N. TEXAS AVENUE BRYAN, TX 77803 (979) 268-3195 ENGINEER: SCHULTZ ENGINEERING, LLC. PO BOX 11995 COLLEGE STATION, TX 77842 (979)764-3900 e SCALE VERTICAL N/A HORIZONTAL 111=20' PLOTTING SCALE: 1:1 FILE NAME: 15-384 SHEET I m I LANDSCAPE LEGEND EXISTING CANOPY TREE (BURR OAK) 0 PROPOSED CANOPY TREE (LIVE OAK) 0 EXISTING SHRUB (SEA GREEN JUNIPER) 0 PROPOSED SHRUB (SEA GREEN JUNIPER) E E � E E E E � E E ."'im-kchlulultz Engineering, LL%.Ip 2730 Longmire, Suite A College Station, Texas 77845 979.764.3900 TBPE NO. 12327 SURVEYED DESIGNED I DRAWN I APPROVED I JOB NO. DATE KERR I DLD I DLD I JPS 1 15-384 1 APRIL 2015 THIS DOCUMENT IS RELEASED FOR THE PURPOSE OF REVIEW ONLY UNDER THE AUTHORITY OF DEVEN L. DOYEN P.E.. LICENSE NO. 109835, ON APRIL 1. 2015' IT IS NOT TO BE USED FOR BIDDING OR CONSTRUCTION PURPOSES. GRADING PLAN CASTLE ROCK AMENITY CENTER CASTLE ROCK SUBDIVISION - PH 2B COMMON AREA (AMMENITY CENTER) - COLLEGE STATION, TX LANDSCAPE & GRADI-N-G PLAI� GRADING NOTES: 1. FILL MATERIAL USED TO ACHIEVE GRADE IN AREAS TO RECEIVE PAVEMENT OR WITHIN THE STREET RIGHT-OF-WAY SHALL BE COMPACTED TO AT LEAST 98% OF THE MAXIMUM DRY DENSITY AS DETERMINED BY THE STANDARD PROCTOR TEST, (ASTM D698), AT A MOISTURE CONTENT FROM OPTIMUM MOISTURE CONTENT TO 4% ABOVE THE OPTIMUM MOISTURE CONTENT. AREAS OUTSIDE OF THE STREET RIGHT-OF-WAY OR PAVEMENT AREAS SHALL BE COMPACTED TO 95X OF THE MAXIMUM DRY DENSITY. 2. THE SUBGRADE BENEATH THE CONCRETE SIDEWALKS SHALL BE 6" STABILIZED SUBGRADE OR SELECT FILL. 3. HANDICAP RAMP SLOPES SHALL NOT EXCEED 1V:12H. 4. THE TOPOGRAPHY SHOWN IS FROM FIELD SURVEY DATA. 5. STRUCTURAL BACKFILL FOR UTILITY OR STORM DRAIN TRENCHES IS REQUIRED WHENEVER THE TRENCH IS WITHIN 5' OF PAVEMENT OR SIDEWALK. 6. THE CONTRACTOR SHALL FOLLOW THE GENERAL INTENT OF THE GRADING PLANS. MINOR ADJUSTMENTS TO THE ACTUAL ELEVATIONS SHOWN ON THE GRADING PLAN MAY BE REQUIRED TO MATCH EXISTING GROUND ELEVATIONS AND STRUCTURES. THE PROPOSED CONTOUR LINES SHOWN ARE APPROXIMATE ONLY, THE DESIGN GRADE SPOT ELEVATIONS SHOULD BE USED FOR CONSTRUCTION OF THE SITE WORK. 7. THE CONTRACTOR SHALL SALVAGE ALL TOPSOIL AND REPLACE IT ON ALL DISTURBED AREAS. ALL PARKING LOT ISLANDS AND AREAS ADJACENT TO PARKING AND SIDEWALK AREAS SHALL RECEIVE 6" SANDY LOAM TOPSOIL PRIOR TO PLACEMENT OF GRASS SOD OR HYDROMULCH. 8. POSITIVE DRAINAGE AWAY FROM ALL SIDES OF THE PROPOSED BUILDING PAD SHALL BE PROVIDED. USE OF INTERCEPTOR DRAINAGE SWALES OR DRAINAGE PIPING SYSTEMS TO ROUTE STORMWATER AROUND AND NOT THROUGH THE BUILDING PAD AREA. 9. THE SELECT FILL FOR THE BUILDING FOUNDATION SHALL BE CONSTRUCTED IN ACCORDANCE WITH THE GEOTECHNICAL REPORT. 10. THE UPPER PORTION OF ALL UTILITY EXCAVATIONS SHOULD BE BACKFILLED WITH PROPERLY COMPACTED CLAY SOILS TO MINIMIZE INFILTRATION OF SURFACE WATER. A CLAY "PLUG' SHOULD BE PROVIDED IN THE TRENCH ON THE EXTERIOR OF THE BUILDING TO PREVENT WATER FROM GAINING ACCESS ALONG THE TRENCH TO THE SUBGRADE BENEATH THE STRUCTURE. THE PLUG SHALL EXTEND TWO FEET BEYOND THE PIPE FACE IN ALL DIRECTIONS, AND A MINIMUM OF TWO FEET THICK. 11. REFER TO THE GEOTECHNICAL REPORT FOR DETAILED SPECIFICATIONS ON SUBGRADE, PAVEMENT, FOUNDATIONS, ETC. 12. ALL UNPAVED AREAS SHALL BE ADEQUATELY GRADED TO DRAIN, SO THAT NO PONDING OCCURS. 13. FINISH GRADE ADJACENT TO CURBING OR SIDEWALK SHALL BE fit" BELOW THE TOP OF CONCRETE AND 2" BELOW IN LANDSCAPING AREAS. 14. ADEQUATE DRAINAGE SHALL BE MAINTAINED AT ALL TIMES DURING CONSTRUCTION AND ANY DRAINAGE DITCH OR STRUCTURE DISTURBED DURING CONSTRUCTION SHALL BE RESTORED TO EXISTING CONDITIONS OR BETTER. 15. THE APPROVAL OF THESE PLANS IS NOT AN AUTHORIZATION TO GRADE ADJACENT PROPERTIES. WHEN FIELD CONDITIONS WARRANT OFF-SITE GRADING, PERMISSION MUST BE OBTAINED FROM THE AFFECTED PROPERTY OWNER(S). ANY ADJACENT PROPERTY AND RIGHT-OF-WAY DISTURBED DURING CONSTRUCTION WILL BE RETURNED TO THEIR EXISTING CONDITIONS OR BETTER. 16. THE DETENTION FACILITIES MUST BE CONSTRUCTED FIRST. 17. THE CONTRACTOR SHALL REFER TO THE STRUCTURAL ENGINEER'S PLANS FOR SPECIFICATIONS. PROCEDURES, AND REQUIREMENTS FOR THE BUILDING PAD. 18. EXISTING TREES, STUMPS, AND LARGE TREE SYSTEMS, SHALL BE GRUBBED AND REMOVED. VEGETATION SHALL BE REMOVED AND THE TOP 6-24 INCHES OF TOP SOIL AND SUB -GRADE BE STRIPPED FROM THE AREAS TO BE COVERED BY THE PROPOSED IMPROVEMENTS. 19. EXISTING DRAINAGE WAYS THAT ARE TO BE FILLED SHALL HAVE BENCHES EXCAVATED INTO THE SIDE WALLS OF THE CHANNEL PRIOR TO PLACEMENT OF FILL BENCHES SHOULD BE AT LEAST 6 FEET IN WIDTH WITH ONE BENCH BEING PLACED VERTICALLY FOR EVERY 2 FEET OF CHANNEL DEPTH. 20. MATERIAL EXCAVATED ON SITE, EXCLUDING THE TOP 6-24 INCHES OF TOP SOIL, MAY USED AS A FILL MATERIAL, UNDER PAVEMENT AREAS ONLY, IF THE MATERIAL IS FREE FROM TRASH, LUMPS, CLODS, ORGANIC SUBSTANCE, & OTHER FOREIGN MATTER AND SUBGRADE PREPARATION FILL MATERIAL PLACEMENT UNDER BUILDINGS SHALL BE IN ACCORDANCE WITH THE GEOTECHNICAL REPORT. 21. STABILIZED MATERIAL OR FILL MATERIAL SHALL BE PLACED IN EIGHT INCH MAXIMUM LOOSE LIFTS. WITH EACH LIFT WETTED OR DRIED TO A MOISTURE CONTENT RANGE OF 0% TO +4% OF THE OPTIMUM MOISTURE CONTENT AND COMPACTED TO A UNIFORM DENSITY OF 98% (FOR STABILIZED) AND 95% (FOR GENERAL FILL) OF THE MAXIMUM DRY DENSITY AS DETERMINED BY ASTM D698. TP - TOP OF PAVEMENT TC - TOP OF CURB TW - TOP OF WALK TS - TOP OF BERM TG - TOP OF GROUND TRW - TOP OF RETAINING WALL LEGEND 280 PROPOSED CONTOUR - 280 - - EXISTING CONTOUR W-8 W-8 S-8 UE UE PROPERTY BOUNDARY ADJACENT PROPERTY BOUNDARY RIGHT OF WAY LOT LINE -PROPERTY SETBACK - PROPOSED PUBLIC UTILITY EASEMENT - EXISTING PUBLIC UTILITY EASEMENT PROPOSED PUBLIC ACCESS EASEMENT EXISTING PUBLIC ACCESS EASEMENT PROPOSED LANDSCAPING EXISTING LANDSCAPING PROPOSED CURB AND GUTTER EXISTING CURB AND GUTTER FLOW ARROWS PROPOSED WATERLINE, SIZE NOTED EXISTING WATERLINE, SIZE NOTED EXISTING SANITARY SEWER UNE, SIZE NOTED EXISTING UNDERGROUND ELECTRIC UNE SCALE VERTICAL 1 "=4' HORIZONTAL 1"=40' PLOTTING SCALE: 1:1 FILE NAME: 15-3$4 SHEET VICINITY MAP LI �r O� PROJECT 0 LOCATION GASTL OGK ARKW A STATE HIGHWAY 40 - WILLIAM D. FITCH PARKWAY 0� 4� N NOT TO SCALE OWNER/DEVELOPER: CASTLE ROCK HOMEOWNERS ASSOCIATION, INC. P.O. BOX 9748 COLLEGE STATION, TX 77845 SPLAS11 PAD ADDITION Ims L _Igo MEN geqilop CI (ki 0 LEGE STATION, TEXA;z THIS DOCUMENT IS RELEASED FOR THE PURPOSE OF REVIEW ONLY UNDER THE AUTHORITY OF DEVEN L. DOYEN P.E., LICENSE NO. 109835, ON APRIL 1, 2015. IT IS NOT TO BE USED FOR BIDDING OR CONSTRUCTION PURPOSES. SCHEDULE (DF SHEETS SHEET TITLE Ct SITE & EROSION CONTROL PLAN C2 LANDSCAPE &GRADING PLAN i j UAJ 1 LC KUU& YA11(K W A Y 70' ROW - 38' B -B PAVEMENT WIDTH LIMITS OF DISTURBANCE SChultz Engineering, 2730 Longmire, Suite A College Station, Texas 77845 979.764.3900 TBPE NO. 12327 SURVEYED DESIGNED DRAWN APPROVED JOB NO. DATE KERR DLD DLD JPS 15-384 APRIL 2015 THIS DOCUMENT IS RELEASED FOR THE PURPOSE OF REVIEW ONLY UNDER THE AUTHORITY OF DEVEN L. DOYEN P.E., LICENSE NO. 109835. ON APRIL 1. 2015. IT IS NOT TO BE USED FOR BIDDING OR CONSTRUCTION PURPOSES. N 20 10 0 20 SCALE IN FEET 2"0" WIRE MESH (OPTIONAL) FASTENED TO T -POST OR WOODEN STAKE METAL T -POST OR WOODEN STAKE AS REQUIRED TO MAINTAIN. SPACED 6' APART NATURAL 4"X4' MIN. SEDIMENT CONTROL FABRIC FASTENED SECURELY TO T -POST OR WOODEN STAKE WITH OPTIONAL WIRE MESH 8" OF FILTER FABRIC TO EXTEND INTO A TRENCH AND BE ANCHORED WITH COMPACTED BACKFILL DIRE OF FLOW 4. j 1 `-ALLOW 2.5' TO 5' AT TOE OF SLOPE FOR SEDIMENT 20" TO ACCUMULATE. ALIGN l FENCE ALONG SLOPE CONTOURS. SILT FENCE ASSEMBLY DETAIL N.T.S. GENERAL NOTES: 1. ALL CONSTRUCTION SHALL BE IN ACCORDANCE WITH THE LATEST CITY OF BRYAN/COLLEGE STATION STANDARD SPECIFICATIONS AND DETAILS FOR (WATER, SEWER, STREETS, DRAINAGE). ALL CONSTRUCTION SHALL BE COORDINATED WITH THE CITY ENGINEER'S OFFICE. 2. ALL UTILITY LINES (WATER, GAS, SANITARY SEWER, STORM SEWER, ETC.) SHOWN ARE TAKEN FROM BEST AVAILABLE RECORD INFORMATION BASED ON CONSTRUCTION UTILITY MAP DOCUMENTS OBTAINED FROM CITY & INDEPENDENT AGENCIES AND/OR ABOVE GROUND FIELD EVIDENCE. SHOWN POSITIONS MAY NOT REPRESENT AS -BUILT CONDITIONS 3. THE CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING THE EXACT LOCATION OF ALL EXISTING UNDERGROUND UTILITIES. NOTIFICATION OF THE UTILITY COMPANIES 48 HOURS IN ADVANCE OF CONSTRUCTION IS REQUIRED. DIG TESS: (800) 344-8377 ATMOS ENERGY: (979) 774-2506 SUDDEN LINK COMMUNICATIONS: (979) 595-2429 VERIZON: (979) 821-4770 4. THE CONSTRUCTION SHALL COMPLY WITH OSHA STANDARD 29 CFR PART 1926 SUBPART P FOR TRENCH SAFETY REQUIREMENTS. 5. BUILDING SETBACK SHALL BE IN ACCORDANCE WITH THE CITY OF COLLEGE STATION UNIFIED DEVELOPMENT ORDNANCE. 6. PROPOSED SIGNS SHALL BE PERMITTED SEPARATELY IN ACCORDANCE WITH THE UDO. 7. ALL ROOF AND GROUND -MOUNTED MECHANICAL EQUIPMENT SHALL BE SCREENED FROM VIEW OR ISOLATED SO AS NOT TO BE VISIBLE FROM ANY PUBLIC RIGHT-OF-WAY OR RESIDENTIAL DISTRICT WITHIN 150' OF THE SUBJECT PROPERTY, MEASURED FROM A POINT 5 FEET ABOVE GRADE. SUCH SCREENING SHALL BE COORDINATED WITH THE BUILDING ARCHITECTURE AND SCALE TO MAINTAIN A UNIFIED APPEARANCE. 8. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO USE WHATEVER MEANS NECESSARY TO MINIMIZE EROSION AND PREVENT SEDIMENT FROM LEAVING THE PROJECT SITE. THIS INCLUDES THE INSTALLATION OF A CONSTRUCTION EXIT AND SILT FENCE AS NECESSARY. S. THE CONTRACTOR IS REQUIRED TO MAINTAIN THE TPDES GENERAL PERMIT NO. TXR 150000 REQUIREMENTS FOR CONSTRUCTION SITES. 10. PERMANENT VEGETATION WILL BE ESTABLISHED ON THE DISTURBED AREAS AFTER CONSTRUCTION IS COMPLETE BY HYDROMULCHING AND SEEDING ALL DISTURBED AREAS. 11. EXTERIOR BUILDING AND SITE LIGHTING SHALL MEET THE STANDARDS OF SECTION 7.11 OF THE UNIFIED DEVELOPMENT ORDINANCE. THE LIGHT SOURCE SHALL NOT PROJECT BELOW AN OPAQUE HOUSING AND NO FIXTURE SHALL DIRECTLY PROJECT LIGHT HORIZONTALLY. FIXTURES WILL BE MOUNTED IN SUCH A MANNER THAT THE PROJECTED CONE OF LIGHT DOES NOT CROSS ANY PROPERTY UNE. PLEASE NOTE THAT COMPLIANCE WITH THIS SECTION WILL BE VERIFIED AT THE TIME OF BUILDING PERMIT AND CERTIFICATE OF OCCUPANCY. 12. DRAINAGE INFORMATION AND DETAILS WILL BE PROVIDED ON THE DRAINAGE PLAN AND DRAINAGE REPORT. 13. LANDSCAPING AND IRRIGATION DESIGN & ANALYSIS WILL BE PROVIDED ON THE LANDSCAPE & IRRIGATION PLANS. THE IRRIGATION SYSTEM MUST BE APPROVED AND INSTALLED PRIOR TO CERTIFICATE OF OCCUPANT. 14. ALL RADII AND DISTANCES ARE MEASURED TO THE BACK OF CURB UNLESS OTHERWISE NOTED. 15. ALL PAVEMENT SHALL BE PER TYPICAL PAVEMENT SECTION. REFER TO PAVEMENT PLAN FOR PAVEMENT DEPTHS. 16.100% COVERAGE OF GROUNDCOVER, DECORATIVE PAVING, DECORATIVE ROCK (NOT LOOSE), OR A PERENNIAL GRASS IS REQUIRED IN PARKING LOT ISLANDS, SWALES AND DRAINAGE AREAS, THE PARKING LOT SETBACK, RIGHT-OF-WAYS, AND ADJACENT PROPERTY DISTURBED DURING CONSTRUCTION 17. DETENTION AND DRAINAGE FACILITIES SHALL BE CONSTRUCTED FIRST. 18. THE CONTRACTOR SHALL PROMPTLY NOTIFY THE ENGINEER OF ANY DISCREPANCIES IN THESE PLANS, DRAWINGS AND SPECIFICATIONS. 19. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO COMPLY WITH ALL STATE AND FEDERAL REGULATIONS REGARDING CONSTRUCTION ACTIVITIES NEAR ENERGIZED OVERHEAD POWER LINES. 20. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE PROTECTION OF ALL EXISTING UTILITIES OR SERVICE LINES THAT ARE CROSSED OR EXPOSED DURING CONSTRUCTION OPERATIONS, WHERE EXISTING UTILITIES OR SERVICE LINES ARE CUT, BROKEN, OR DAMAGED, THE CONTRACTOR SHALL REPAIR OR REPLACE THE UTILITIES OR SERVICE UNE WITH THE SAME TYPE OF MATERIAL AND CONSTRUCTION OR BETTER. THIS MATERIAL AND WORK SHALL BE AT THE CONTRACTOR'S OWN EXPENSE. 21.A COPY OF THE APPROVED CONSTRUCTION PLANS MUST BE KEPT ON SITE AT ALL TIMES THROUGHOUT THE ENTIRE CONSTRUCTION OF THE PROJECT. CONTRACTOR SHALL MAINTAIN A SET OF REDLINE DRAWINGS, RECORDING AS -BUILT CONDITIONS DURING CONSTRUCTION. 22. R SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO PAY FOR AND OBTAIN ALL REQUIRED PERMITS AND INSPECTION APPROVALS FOR ALL WORK SHOWN. 23. ANY ADJACENT PROPERTY AND RIGHT-OF-WAY DISTURBED DURING CONSTRUCTION WILL BE RETURNED TO THEIR EXISTING CONDITION OR BETTER. 24. THE CONTRACTOR SHALL NOT CREATE A DIRT NUISANCE OR SAFETY HAZARD IN ANY STREET OR DRIVEWAY. 25. ADEQUATE DRAINAGE SHALL BE MAINTAINED AT ALL TIMES DURING CONSTRUCTION AND ANY DRAINAGE DITCH OR STRUCTURE DISTURBED DURING CONSTRUCTION SHALL BE RESTORED TO EXISTING CONDITIONS OR BEII . 26. THE CONTRACTOR AGREES TO REPAIR ANY DAMAGE TO THE PUBLIC RIGHT-OF-WAY IN ACCORDANCE WITH THE STANDARDS OF THE APPLICABLE REGULATORY AGENCY. 27. THE CONTRACTOR SHALL PROTECT ALL MONUMENTS, IRON PINS, AND PROPERTY CORNERS DURING CONSTRUCTION. 28. THE CONTRACTOR MUST PROVIDE CONSTRUCTION STAKING FROM THE INFORMATION PROVIDED ON THE PLANS AND DRAWINGS. 29. THE CONTRACTOR MAY OBTAIN AN ELECTRONIC COPY OF THESE PLANS FOR CONSTRUCTION PURPOSES. THE ELECTRONIC RLE AND INFORMATION GENERATED, BY SCHULTZ ENGINEERING, LLC (SE), FOR THIS PROJECT IS CONSIDERED BY SE TO BE CONFIDENTIAL. WHEN ISSUED. ITS USE IS INTENDED SOLELY FOR THE INDIVIDUAL OR ENTITY TO WHICH IT IS ADDRESSED. PERMISSION IS NOT GRANTED TO THE RECIPIENT FOR DISTRIBUTION OF THESE DOCUMENTS IN ANY FORM OR FASHION. THE RECIPIENT UNDERSTANDS THAT THIS DATA IS AUTHORIZED "AS IS" WITHOUT ANY WARRANTY AS TO IT PERFORMANCE, ACCURACY, FREEDOM FROM ERROR, OR AS TO ANY RESULTS GENERATED THROUGHOUT ITS USE. THE RECIPIENT ALSO UNDERSTANDS AND AGREES THAT SE, UPON RELEASE OF SUCH DATA, IS NO LONGER RESPONSIBLE FOR THEIR USE OR MODIFICATION. THE USER AND RECIPIENT OF THE ELECTRONIC DATA ACCEPTS FULL RESPONSIBILITY AND LIABILITY FOR ANY CONSEQUENCES ARISING OUT OF THEIR USE. EROSION CONTROL NOTES: 1. THE CONTRACTOR IS REQUIRED TO MAINTAIN THE TPDES GENERAL PERMIT NO. TXR 150000 REQUIREMENTS FOR CONSTRUCTION SITES. 2. EROSION CONTROL MEASURES SHOWN IN THESE PLANS SHALL BE CONSIDERED THE VERY MINIMUM REQUIRED. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO IMPLEMENT ALL OTHER EROSION CONTROL MEASURES (DIVERSION BERMS. DRAINAGE STRUCTURES, SWALES, ADDITIONAL FENCING, ETC...) NECESSARY TO KEEP THE EXISTING IMPROVEMENTS AND DEVELOPMENTS FROM DAMAGE OF ANY KIND, DURING ALL PHASES OF DEMOLITION AND CONSTRUCTION. 3. ALL SEDIMENT TRAPPING DEVICES SHALL BE INSTALLED AS SOON AS PRACTICAL AFTER THE AREA HAS BEEN DISTURBED. ALL SEDIMENT TRAPPING DEVICES SHALL BE CLEANED WHEN SEDIMENT LEVEL REACHES 25% CAPACITY. SEDIMENT SHALL BE DISPOSED OF BY SPREADING ON SITE OR HAULING AWAY IF NOT SUITABLE FOR FILL. 4. EROSION CONTROL MEASURES SHALL BE IMPLEMENTED PRIOR TO ANY EXCAVATION OR DEMOLITION WORK. 5. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO USE WHATEVER MEANS NECESSARY TO MINIMIZE EROSION AND PREVENT SEDIMENT FROM LEAVING THE PROJECT SITE. THIS INCLUDES THE INSTALLATION OF A CONSTRUCTION EXIT AND SILT FENCE AS NECESSARY. 6. THE CONTRACTOR IS RESPONSIBLE FOR INSPECTING AND MAINTAINING THE EROSION AND SEDIMENT CONTROL DEVICES. INSPECTIONS SHALL BE DONE EVERY 14 DAYS AND AFTER EVERY RAINFALL EVENT OF 1/2" OR MORE. THE CONTRACTOR SHALL REMOVE ALL MUD DEPOSITED ON THE ADJACENT STREETS AS A RESULT OF THE CONSTRUCTION OF THIS PROJECT. 7. THE CONTRACTOR SHALL REMOVE THE EROSION CONTROL MEASURES ONCE GRASS IS ESTABLISHED. 8. INLET PROTECTION TO BE INSTALLED AT ALL PROPOSED AND EXISTING INLETS ADJACENT TO THE PROJECT SITE. 9. CONSTRUCTION EXIT IS TO BE DRESSED WITH ADDITIONAL ROCK AS NEEDED AND MAINTAINED SO AS TO PREVENT CONSTRUCTION TRAFFIC FROM TRACKING MUD ONTO ADJACENT PUBLIC STREETS. 10. ALL AREAS WHERE EXISTING VEGETATION AND GRASS COVER HAVE BEEN DISTURBED BY CONSTRUCTION SHALL BE ADEQUATELY HYDROMULCHED OR BLOCK SODDED, AND WATERED UNTIL GROWTH IS ESTABLISHED. ALL EROSION CONTROL MEASURES SHALL REMAIN IN PLACE UNTIL ACCEPTABLE VEGETATIVE GROWTH IS ESTABLISHED AFTER CONSTRUCTION IS COMPLETE AND THEN REMOVED BY CONTRACTOR. CASTLE ROCK AMENITY CENTER SPLASH PAD ADDITION CASTLE ROCK SUBDIVISION - PH 2B COMMON AREA (AMMENITY CENTER) - COLLEGE STATION, TX SITE & EROSIO CONTROL PLA SITE SPECIFIC NOTES• 1. THE OWNER OF THE PROPERTY IS CASTLE ROCK HOMEOWNERS ASSOCIATION, INC. THE SUBJECT PROPERTY IS CASTLE ROCK SUBDIVISION, PHASE 28. PROPERTY IS ZONED PDD (PLANNED DEVELOPMENT DISTRICT). 2. THE TOTAL DISTURBED AREA FOR THIS PROJECT IS 0.103 ACRES (4501 SF). 3. THE SUBJECT TRACT DOES NOT LIE WITHIN THE 100 YEAR FLOODPLAIN ACCORDING TO FEMA FLOOD INSURANCE RATE MAPS FOR BRAZOS COUNTY. TEXAS AND INCORPORATED AREAS. COMMUNITY NO. 480083. PANEL NO. 0325E, MAP NO. 48041CO32SE, EFFECTIVE DATE: MAY 16, 2012. 4. CONTOURS SHOWN ARE FROM FIELD SURVEY DATA. S. ALL ELECTRICAL IMPROVEMENTS SHALL BE PER COLLEGE STATION UTILITIES SPECIFICATIONS AND PER THE COLLEGE STATION UTILITIES ELECTRICAL DESIGN FOR THIS PROJECT. ELECTRIC PROJECT COORDINATOR CITY OF COLLEGE STATION UTILITIES 979-764-8314 VICINITY MAP PROJECT LOCATION A ON STATE HIGHWAY 40 - WILLIAM D. FITCH PARKWA NOT TO mmlim D�ko'mi QQ TOTAL AREA = 0.654 ACRES CASTLE ROCK SUBDIVION - PHASE 2B COMMON AREA (AMMENITY CENTER) 9117/118 ROBERT STE eam SURVEY, A-54 STATION, BWOS OOLtM, TEXAS SCALE: 1 "=20' APRIL 2015 OWNER/DEVELOPER: CASTLE ROCK HOMEOWNERS ASSOCIATION, INC. P.i1l. BOX 9748 COLLEGE STATION, TX 77845 SURVEYOR: BRAD KERR, RPLS NO. 4502 KERR SURVEYING, LLC 409 N. TEXAS AVENUE BRYAN, TX 77803 (979) 268-3195 SCHULTZ ENGINEERING, LLC. PO BOX 11995 COLLEGE STATION, TX 77842 (979)764-3900 SCALE VERTICAL N/A HORIZONTAL 11 =20' PLOTTING SCALE: 1:1 FILE NAME: 15-384 SHEET {L Curve Table CURVE # LENGTH RADIUS DELTA TANGENT CHORD CHORD DIRECTION C11 80.84' 480.00' 00738'59" 40.52' 80.75' S6645'04"E C12 28.39' 25.00' 065'04'31" 15.95' 26.89' S82'49'45"W C13 246.32' 465.00' 1 030'21'05' 126.13' 243.45' N79'48'33W VICINITY MAP PROJECT LOCATION A ON STATE HIGHWAY 40 - WILLIAM D. FITCH PARKWA NOT TO mmlim D�ko'mi QQ TOTAL AREA = 0.654 ACRES CASTLE ROCK SUBDIVION - PHASE 2B COMMON AREA (AMMENITY CENTER) 9117/118 ROBERT STE eam SURVEY, A-54 STATION, BWOS OOLtM, TEXAS SCALE: 1 "=20' APRIL 2015 OWNER/DEVELOPER: CASTLE ROCK HOMEOWNERS ASSOCIATION, INC. P.i1l. BOX 9748 COLLEGE STATION, TX 77845 SURVEYOR: BRAD KERR, RPLS NO. 4502 KERR SURVEYING, LLC 409 N. TEXAS AVENUE BRYAN, TX 77803 (979) 268-3195 SCHULTZ ENGINEERING, LLC. PO BOX 11995 COLLEGE STATION, TX 77842 (979)764-3900 SCALE VERTICAL N/A HORIZONTAL 11 =20' PLOTTING SCALE: 1:1 FILE NAME: 15-384 SHEET {L LANDSCAPE PLAN. LANDSCAPE LEGEND "`` EXISTING CANOPY TREE (BURR OAK) 0 PROPOSED CANOPY TREE (LIVE OAK) 0 EXISTING SHRUB (SEA GREEN JUNIPER) 0 PROPOSED SHRUB (SEA GREEN JUNIPER) f% ,,% hL; E Un ineerin 2730 Long mire Suite A College Station, Texas 77845 979.764.3900 TBPE NO. 12327 SURVEYED DESIGNED DRAWN APPROVED JOB NO. DATE KERR I DLD I DLD I JPS 1 15-384 1 APRIL 2015 THIS DOCUMENT IS RELEASED FOR THE PURPOSE OF REVIEW ONLY UNDER THE AUTHORITY OF DEVEN L. DOYEN P.E.. LICENSE NO. 109835. ON APRIL 1, 2015. IT IS NOT TO BE USED FOR BIDDING OR CONSTRUCTION PURPOSES. w i � GRADING PLAN CASTLE ROCK AMENITY CENTER CASTLE ROCK SUBDIVISION - PH 2B COMMON AREA (A.MMENITY CENTER) - COLLEGE STATION, TX LANDSCAPE & (13-i-RADIN-G PLAI�,4 GRADING NOTES: 1. FILL MATERIAL USED TO ACHIEVE GRADE IN AREAS TO RECEIVE PAVEMENT OR WITHIN THE STREET RIGHT—OF—WAY SHALL BE COMPACTED TO AT LEAST 98X OF THE MAXIMUM DRY DENSITY AS DETERMINED BY THE STANDARD PROCTOR TEST, (ASTM D698), AT A MOISTURE CONTENT FROM OPTIMUM MOISTURE CONTENT TO 4% ABOVE THE OPTIMUM MOISTURE CONTENT. AREAS OUTSIDE OF THE STREET RIGHT—OF—WAY OR PAVEMENT AREAS SHALL BE COMPACTED TO 95X OF THE MAXIMUM DRY DENSITY. 2. THE SUBGRADE BENEATH THE CONCRETE SIDEWALKS SHALL BE 6" STABILIZED SUBGRADE OR SELECT FILL. 3. HANDICAP RAMP SLOPES SHALL NOT EXCEED 1V:12H. 4. THE TOPOGRAPHY SHOWN IS FROM FIELD SURVEY DATA. 5. STRUCTURAL BACKFILL FOR UTILITY OR STORM DRAIN TRENCHES IS REQUIRED WHENEVER THE TRENCH IS WITHIN 5' OF PAVEMENT OR SIDEWALK. 6. THE CONTRACTOR SHALL FOLLOW THE GENERAL INTENT OF THE GRADING PLANS. MINOR ADJUSTMENTS TO THE ACTUAL ELEVATIONS SHOWN ON THE GRADING PLAN MAY BE REQUIRED TO MATCH EXISTING GROUND ELEVATIONS AND STRUCTURES. THE PROPOSED CONTOUR LINES SHOWN ARE APPROXIMATE ONLY, THE DESIGN GRADE SPOT ELEVATIONS SHOULD BE USED FOR CONSTRUCTION OF THE SITE WORK. 7. THE CONTRACTOR SHALL SALVAGE ALL TOPSOIL AND REPLACE IT ON ALL DISTURBED AREAS. ALL PARKING LOT ISLANDS AND AREAS ADJACENT TO PARKING AND SIDEWALK AREAS SHALL RECEIVE 6" SANDY LOAM TOPSOIL PRIOR TO PLACEMENT OF GRASS SOD OR HYDROMULCH. 8. POSITIVE DRAINAGE AWAY FROM ALL SIDES OF THE PROPOSED BUILDING PAD SHALL BE PROVIDED. USE OF INTERCEPTOR DRAINAGE SWALES OR DRAINAGE PIPING SYSTEMS TO ROUTE STORMWATER AROUND AND NOT THROUGH THE BUILDING PAD AREA. 9. THE SELECT FILL FOR THE BUILDING FOUNDATION SHALL BE CONSTRUCTED IN ACCORDANCE WITH THE GEOTECHNICAL REPORT. 10. THE UPPER PORTION OF ALL UTILITY EXCAVATIONS SHOULD BE BACKFILLED WITH PROPERLY COMPACTED CLAY SOILS TO MINIMIZE INFILTRATION OF SURFACE WATER. A CLAY "PLUG" SHOULD BE PROVIDED IN THE TRENCH ON THE EXTERIOR OF THE BUILDING TO PREVENT WATER FROM GAINING ACCESS ALONG THE TRENCH TO THE SUBGRADE BENEATH THE STRUCTURE. THE PLUG SHALL EXTEND TWO FEET BEYOND THE PIPE FACE IN ALL DIRECTIONS, AND A MINIMUM OF TWO FEET THICK. 11. REFER TO THE GEOTECHNICAL REPORT FOR DETAILED SPECIFICATIONS ON SUBGRADE, PAVEMENT, FOUNDATIONS, ETC. 12. ALL UNPAVED AREAS SHALL BE ADEQUATELY GRADED TO DRAIN, SO THAT NO PONDING OCCURS. 13. FINISH GRADE ADJACENT TO CURBING OR SIDEWALK SHALL BE %" BELOW THE TOP OF CONCRETE AND 2" BELOW IN LANDSCAPING AREAS. 14. ADEQUATE DRAINAGE SHALL BE MAINTAINED AT ALL TIMES DURING CONSTRUCTION AND ANY DRAINAGE DITCH OR STRUCTURE DISTURBED DURING CONSTRUCTION SHALL BE RESTORED TO EXISTING CONDITIONS OR BETTER. 15. THE APPROVAL OF THESE PLANS IS NOT AN AUTHORIZATION TO GRADE ADJACENT PROPERTIES. WHEN FIELD CONDITIONS WARRANT OFF—SITE GRADING, PERMISSION MUST BE OBTAINED FROM THE AFFECTED PROPERTY OWNER(S). ANY ADJACENT PROPERTY AND RIGHT—OF—WAY DISTURBED DURING CONSTRUCTION WILL BE RETURNED TO THEIR EXISTING CONDITIONS OR BETTER. 16. THE DETENTION FACILITIES MUST BE CONSTRUCTED FIRST. 17. THE CONTRACTOR SHALL REFER TO THE STRUCTURAL ENGINEER'S PLANS FOR SPECIFICATIONS. PROCEDURES, AND REQUIREMENTS FOR THE BUILDING PAD. 18. EXISTING TREES, STUMPS, AND LARGE TREE SYSTEMS, SHALL BE GRUBBED AND REMOVED. VEGETATION SHALL BE REMOVED AND THE TOP 6-24 INCHES OF TOP SOIL AND SUB—GRADE BE STRIPPED FROM THE AREAS TO BE COVERED BY THE PROPOSED IMPROVEMENTS. 19. EXISTING DRAINAGE WAYS THAT ARE TO BE FILLED SHALL HAVE BENCHES EXCAVATED INTO THE SIDE WALLS OF THE CHANNEL PRIOR TO PLACEMENT OF FILL. BENCHES SHOULD BE AT LEAST 6 FEET IN WIDTH WITH ONE BENCH BEING PLACED VERTICALLY FOR EVERY 2 FEET OF CHANNEL DEPTH. 20. MATERIAL EXCAVATED ON SITE, EXCLUDING THE TOP 6-24 INCHES OF TOP SOIL, MAY USED AS A FILL MATERIAL, UNDER PAVEMENT AREAS ONLY, IF THE MATERIAL IS FREE FROM TRASH, LUMPS, CLODS, ORGANIC SUBSTANCE, do OTHER FOREIGN MATTER AND SUBGRADE PREPARATION FILL MATERIAL PLACEMENT UNDER BUILDINGS SHALL BE IN ACCORDANCE WITH THE GEOTECHNICAL REPORT. 21. STABILIZED MATERIAL OR ALL MATERIAL SHALL BE PLACED IN EIGHT INCH MAXIMUM LOOSE LIFTS, WITH EACH UFT WETTED OR DRIED TO A MOISTURE CONTENT RANGE OF OX TO +4X OF THE OPTIMUM MOISTURE CONTENT AND COMPACTED TO A UNIFORM DENSITY OF 98X (FOR STABILIZED) AND 95X (FOR GENERAL FILL) OF THE MAXIMUM DRY DENSITY AS DETERMINED BY ASTM D698. TP — TOP OF PAVEMENT TC — TOP OF CURB TW — TOP OF WALK TB — TOP OF BERM TG — TOP OF GROUND TRW — TOP OF RETAINING WALL LEGEND 280 PROPOSED CONTOUR — — 280 — — EXISTING CONTOUR PROPERTY BOUNDARY ADJACENT PROPERTY BOUNDARY RIGHT OF WAY LOT UNE — —PROPERTY SETBACK — PROPOSED PUBLIC UTILITY EASEMENT — EXISTING PUBLIC UTILITY EASEMENT PROPOSED PUBLIC ACCESS EASEMENT EXISTING PUBLIC ACCESS EASEMENT PROPOSED LANDSCAPING EXISTING LANDSCAPING UM17S OF DISTURBANCE PROPOSED CURB AND GUTTER EXISTING CURB AND GUTTER FLOW ARROWS W-8 PROPOSED WATERLINE, SIZE NOTED W-8 EXISTING WATERLINE, SIZE NOTED S-8 EXISTING SANITARY SEWER UNE, SIZE NOTED UE UE EXISTING UNDERGROUND ELECTRIC UNE E CALE 1''=4'' L 1 =40CALE: 1:1 15-384 SHEET VICINITY MAP PROJECT LOCATION CAS ocK ARIONA STATE HIGHWAY 40 - Wv-LLkM D' CFI pARICWAIf �g0 NOT TO SCALE OWNER/DEVELOPER: CASTLE ROCK HOMEOWNERS ASSOCIATION, INC. P.O. BOX 9748 COLLEGE STATION, TX 77845 me FMIL16 f lkI Afth am A&:, ISO lall"Im An %LVA COMMONAREA (AMENITY CENTER) COLLEGE STATION, TEXAS ngineering, LLC TBPE FIRM REGISTRATION NO. 12327 2730 LONGMIRE, SUITE A COLLEGE STATION, TEXAS 77845 979.764.3900 THE SEAL APPEARING ON THIS DOCUMENT WAS AUTHORIZED BY DEVEN L. DOYEN, A.E., LICENSE NO. 109835 MAY 12, 2015. RELEASED FOR CONSTRUCTION ........:.........it ....D .L� DOYEN.... �� 109835 • FIRM # 12327 SCHULTZ ENGINEERING. LLC SCHEDULE OF SHEET TITLE Cl SITE &EROSION CONTROL PLAN C2 LANDSCAPE &GRADING PLAN I PARK AREA 4.363 ACRES PER PH 1A 8214/234 l -A J Z U: A -U k.. N r f 11c11 VY : i L 70' ROW - 38' B -B PAVEMENT WIDTH LIMITS OF DISTURBANCE THE SEAL APPEARING ON THIS DOCUMENT WAS AUTHORIZED BY S%chultzE n n e e r i n a, DECEN L. DOYEN, P.E., LICENSE N0. 109835 2730 Longmire, Suite A MAY 12, 2015. College Station, Texas 77845 RELEASED FOR CONSTRUCTION 074 79A AOnn TBPE NO.12327 SURVEYED DESIGNED DRAWN APPROVED JOB NO. DATE KERR DLD DLD JPS 15-384 MAY 2015 FIRM # 12327- ' SCHULTZ 2327- SCHULTZ ENGINEERING, LLC 20 10 0 20 SCALE IN FEET ELEVATION r � 2'X4" WIRE MESH (OP FASTENED TO T -P( WOODEN METAL T -POST OR WOODEN - STAKE AS REQUIRED TO MAINTAIN. SPACED W APART NATURAL 4"X4' MIN. SEDIMENT CONTROL FABRIC FASTENED SECURELY TO T -POST OR WOODEN STAKE WITH OPTIONAL WIRE MESH 8' OF FILTER FABRIC TO EXTEND INTO A TRENCH AND BE ANCHORED WITH COMPACTED BACKFILL I '-ALLOW 2.5' TO 5' AT TOE OF LOPE FOR SEDIMENT 20" TO ACCUMULATE. ALIGN FENCE ALONG SLOPE CONTOURS. SILT FENCE ASSEMBLY DETAIL N.T.S. GENERAL NOTES: 1. ALL CONSTRUCTION SHALL BE IN ACCORDANCE WITH THE LATEST OTY OF BRYAN/COLLEGE STATION STANDARD SPECIFICATIONS AND DETAILS FOR (WATER, SEWER. STREETS, DRAINAGE). ALL CONSTRUCTION SHALL BE COORDINATED WITH THE CITY ENGINEER'S OFFICE. 2. ALL UTILITY LINES (WATER, GAS, SANITARY SEWER, STORM SEWER, ETC.) SHOWN ARE TAKEN FROM BEST AVAILABLE RECORD INFORMATION BASED ON CONSTRUCTION UTILITY MAP DOCUMENTS OBTAINED FROM CITY & INDEPENDENT AGENCIES ANO/OR ABOVE GROUND FIELD EVIDENCE. SHOWN POSITIONS MAY NOT REPRESENT AS -BUILT CONDITIONS 3. THE CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING THE EXACT LOCATION OF ALL EXISTING UNDERGROUND UTILITIES. NOTIFICATION OF THE UTILITY COMPANIES 48 HOURS IN ADVANCE OF CONSTRUCTION IS REQUIRED. DiO TESS: (800 344-8377 ATMOS ENERGY: (979 774-2506 SUDDEN LINK COMMUNICATIONS: 979) 595-2429 VERIZON: 979) 821-4770 4. THE CONSTRUCTION SHALL COMPLY WITH OSHA STANDARD 29 CFR PART 1926 SUBPART P FOR TRENCH SAFETY REQUIREMENTS, 5. BUILDING SETBACK SHALL BE IN ACCORDANCE WITH THE CITY OF COLLEGE STATION UNIFIED DEVELOPMENT ORONANCE 6. PROPOSED SIGNS SHALL BE PERMITTED SEPARATELY IN ACCORDANCE WITH THE UDO. 7. ALL ROOF AND GROUND -MOUNTED MECHANICAL EQUIPMENT SHALL BE SCREENED FROM VIEW OR ISOLATED SO AS NOT TO BE VISIBLE FROM ANY PUBLIC RIGHT-OF-WAY OR RESIDENTIAL DISTRICT WITHIN 18V OF THE SUBJECT PROPERTY, MEASURED FROM A POINT 5 FEET ABOVE GRADE. SUCH SCREENING SHALL BE COORDINA10 WITH THE BUILDING ARCHITECTURE AND SCALE TO MAINTAIN A UNIFIED APPEARANCE. 8. IT iS THE RESPONSIBILITY OF THE CONTRACTOR TO USE WHATEVER MEANS NECESSARY TO MINIMIZE EROSION AND PREVENT SEDIMENT FROM LEAVING THE PROJECT SITE. THIS INCLUDES THE iNSTALLATION OF A CONSTRUCTION EXIT AND SILT FENCE AS NECESSARY. 8. THE CONTRACTOR IS REQUIRED TO MAINTAIN THE TPDES GENERAL PERMIT NO. TXR 150000 REQUIREMENTS FOR CONSTRUCTION SITES. 10. PERMANENT VEGETATION WILL BE ESTABLISHED ON THE DISTURBED AREAS AFTER CONSTRUCTION IS COMPLETE BY HYDROMULCHING AND SEEDING ALL DISTURBED AREAS. 11. EXTERIOR 13UILDINO AND SITE UGHTiNG SHALL MEET THE STANDARDS OF SECTION 7.11 OF THE UNIFIED DEVELOPMENT ORDINANCE. THE LIGHT SOURCE SHALL NOT PROJECT BELOW AN OPAQUE HOUSING AND NO FIXTURE SHALL DIRECTLY PROJECT LIGHT HORIZONTALLY. FIXTURES WILL BE MOUNTED IN SUCH A MANNER THAT THE PROJECTED CONE OF LIGHT DOES NOT CROSS ANY PROPERTY UNE, PLEASE NOTE THAT COMPLIANCE WITH THIS SECTION WILL BE VERIFIED AT THE TIME OF BUILDING PERMIT AND CERTIFICATE OF OCCUPANCY. 12. DRAINAGE INFORMATION AND DETAILS WILL BE PROVIDED ON THE DRAINAGE PLAN AND DRAINAGE REPORT. 13. LANDSCAPING AND IRRIGATION DESIGN do ANALYSIS WILL BE PROVIDED ON THE LANDSCAPE & IRRIGATION PLANS. THE IRRIGATION SYSTEM MUST BE APPROVED AND INSTALLED PRIOR TO CERTIFICATE OF OCCUPANT. 14. ALL RADII AND DISTANCES ARE MEASURED TO THE BACK OF CURB UNLESS OTHERWISE NOTED. 15. ALL PAVEMENT SHALL BE PER TYPICAL PAVEMENT SECTION. REFER TO PAVEMENT PLAN FOR PAVEMENT DEPTHS. Ia. 100% COVERAGE OF GROUNDCOVER, DECORATIVE PAVING, DECORATIVE ROCK (NOT LOOSE), OR A PERENNIAL GRASS IS REQUIRED IN PARKING JOT ISLANDS, SWAM AND DRAINAGE AREAS, THE PARKING LOT SETBACK, RIGHT -OF WAYS, AND ADJACENT PROPERTY DISTURBED DURING CONSTRUCTION 17. DETENTION AND DRAINAGE FACILITIES SHALL BE CONSTRUCTED FIRST. 18. THE CONTRACTOR SHALL PROMPTLY NOTIFY THE ENGINEER OF ANY DISCREPANCIES IN THESE PLANS, DRAWINGS AND SPECIFICATIONS. 19. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO COMPLY WITH ALL STATE AND FEDERAL REGULATIONS REGARDING CONSTRUCTION ACTIVITIES NEAR ENERGIZED OVERHEAD POWER LINES. 20. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE PROTECTION OF ALL EXISTING UTILITIES OR SERVICE LINES THAT ARE CROSSED OR EXPOSED DURING CONSTRUCTION OPERATIONS. WHERE EXISTING UTILITIES OR SERVICE LINES ARE CUT, BROKEN, OR DAMAGED. THE CONTRACTOR SHALL REPAIR OR REPLACE THE UTILITIES OR SERVICE LINE WITH THE SAME TYPE OF MATERIAL AND CONSTRUCTION OR BETTER. THIS MATERIAL AND WORK SHALL BE AT THE CONTRACTOR'S OWN EXPEN21. A COPY OF THE APPROVED CONSTRUCTION PLANS MUST BE KEPT ON SITE AT ALL TIMES THROUGHOUT THE EpMRE CONSTRUCTION OF THE PROJECT. CONTRACTOR SHALL MAINTAIN A SET OF REDUNE DRAWINGS, RECORDING AS -BUILT CONDITIONS DURING CONSTRUCTION. 22. R SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO PAY FOR AND OBTAIN ALL REQUIRED PERMITS AND INSPECTION APPROVALS FOR ALL WORK SHOWN. 23. ANY ADJACENT PROPERTY AND RIGHT-OF-WAY DISTURBED DURING CONSTRUCTION WILL BE RETURNED TO THEIR EXISTING CONDITION OR BETTER. 24. THE CONTRACTOR SHALL NOT CREATE A DIRT NUISANCE OR SAFETY HAZARD IN ANY SIREEII OR ORNEWAY. 25. ADEQUATE DRAINAGE SHALL BE MAINTAINED AT ALL 'TIMES DURING CONSTRUCTION AND ANY DRAINAGE DITCH OR STRUCTURE DISTURBED DURING CONSTRUCTION SHALL BE RESTORED TO EXISTING CONDITIONS OR BETTER. 26. THE CONTRACTOR AGREES TO REPAIR ANY DAMAGE TO THE PUBLIC RIGHT-OF-WAY IN ACCORDANCE WITH THE STANDARDS OF THE APPLICABLE REGULATORY AGENCY. 27. THE CONTRACTOR SHALL PROTECT ALL MONUMENTS, IRON PINS, AND PROPERTY CORNERS DURING CONSTRUCTION. 28. THE CONTRACTOR MUST PROVIDE CONSTRUCTION STAKING FROM THE INFORMATION PROVIDED ON THE PLANS AND DRAWINGS. 29. THE CONTRACTOR MAY OBTAIN AN ELECTRONIC COPY OF THESE PLANS FOR CONSTRUCTION' PURPOSES. THE ELECTRONIC FILE AND INFORMATION GENERATED. BY SCHULTZ ENGINEERING, LLC (SF:), FOR THIS PROJECT IS CONSIDERED BY SE TO BE CONFIDENTIAL WHEN ISSUED, IT'S USE iS INTENDED SOLELY FOR THE INDIVIDUAL OR ENTITY 70 WHICH IT IS ADDRESSED. PERMISSION IS NOT GRA&ffED TO THS RECIPIENT FOR DLSMUTTON OF THESE DOCUMENTS IN ANY FORM OR FASHM. THE RECIPIENT UNDERSTANDS THAT THIS DATA IS AUTHORIZED "AS W WITHOUT ANY WARRANTY AS TO IT PERFORMANCE, ACCURACY. FREEDOM FROM ERROR, OR AS TO ANY RESULTS GENERATED THROUGHOUT ITS USE THE RECIPIENT ALSO UNDERSTANDS AND AGREES THAT SE. UPON RELEASE OF SUCH DATA, IS NO LONGER RESPONSIBLE FOR THEIR USE OR MODIFICATION. THE USER AND RECIPIENT OF THE ELECTRONIC DATA ACCEPTS FULL RESPONSIBILITY AND LIABILITY FOR ANY CONSEQUENCES ARISING OUT OF THEIR USE. Mg=N CONTROL NOTES: 1. THE CONTRACTOR IS REQUIRED TO MAINTAIN THE TPOES GENERAL PERMIT NO. TXR 150000 REQUIREMENTS FOR CONSTRUCTION SITES. 2. EROSION CONTROL MEASURES SHOWN IN THESE PLANS SHALL BE CONSIDERED THE VERY MINIMUM REQUIRED. IT SHALL 8E THE RESPONSIBILITY OF THE CONTRACTOR TO IMPLEMENT ALL OTHER EROSION CONTROL MEASURES (DIVERSION BERMS. DRAINAGE STRUCTURES, SWAT M. ADDITIONAL FENCING, ETC-) NECESSARY TO KEEP THE EXISTING IMPROVEIIIENTS AND DEVELOPMENTS FROM DAMAGE OF ANY KiND, DURING ALL PHASES OF DEMOLITION AND CONSTRUCTION. 3. ALL SEDIMENT TRAPPING DEVICES SHALL BE INSTALLED AS SOON AS PRACTICAL AFTER THE AREA HAS BEEN DISTURBED. ALL SEDIMENT TRAPPING DEVICES SHALL BE CLEANED WHEN SEDIMENT LEVEL REACHES 25X CAPACITY. SEDIMENT SHALL BE DISPOSED OF BY SPREADING ON SITE OR HAULING AWAY IF NOT SUITABLE FOR FILL 4. EROSION CONTROL MEASURES SHALL BE IMPLEMENTED PRIOR TO ANY EXCAVATION OR DEMOLITION WORK. 5. R IS THE RESPONSIBILITY OF THE CONTRACTOR TO USE WHATEVER MEANS NECESSARY TO MINIMIZE EROSION AND PREVENT SEDIMENT FROM LEAVING THE PROJECT SITE. THIS INCLUDES THE INSTALATiON OF A CONSTRUCTION EXIT AND SILT FENCE AS NECESSARY. S. THE CONTRACTOR IS RESPONSIBLE FOR INSPECTING AND MAINTAINING THE EROSION AND SEDIMENT CONTROL DEVICES. INSPECTIONS SHALL BE DONE EVERY 14 DAYS AND AFTER EVERY RAINFALL EVENT OF SLC" OR MORE. THE CONTRACTOR SHALL REMOVE ALL MUD DEPOSITED ON THE ADJACENT STREETS AS A RESULT OF THE CONSTRUCTION OF THIS PROJECT. 7. THE CONTRACTOR SHALL REMOVE THE EROSION CONTROL MEASURES ONCE GRASS IS ESTABLISHED. B. INLETPROTECTION TO BE INSTALLED AT ALL PROPOSED AND EXISTING INLETS ADJACENT TO THE PROJECT SITE. 9. CONSTRUCTION DAT IS TO BE DRESSED WITH ADDITIONAL ROCK AS NEEDED AND MAINTAINED SO AS TO PREVENT CONSTRUCTION TRAFFIC FROM TRACKING MUD ONTO ADJACENT PUBLIC STREETS. 10. ALL AREAS WHERE EXISTING VEGETATION AND GRASS COVER HAVE BEEN DISTURBED BY CONSTRUCTION SHALL BE ADEQUATELY HYDROMULCHED OR BLOCK SODDED, AND WATERED UNTIL GROWTH IS ESTABLISHED. ALL EROSION CONTROL MEASURES SHALL REMAIN iN PLACE UNTiL ACCEPTABLE VEGETATIVE GROWTH 15 ESTABLISHED AFTER CONSTRUCTION IS COMPLETE AND THEN REMOVED BY CONTRACTOR. CASTLE ROCK. AMENITY CENTER SPLASH PAD ADDITION CASTLE ROCK SUBDIVISION - PH 2B COMMON AREA (AMMENITY CENTER) - COLLEGE STATION, TX BENCHMARK INFORMATION TBM 1 N: 10189358.1277 E: 3574609.9387 ELEV : 281.87' (BACK OF CURB) SITE SPECIFIC NOTES: i. THE OWNER OF THE PROPERTY IS CASTLE ROCK HOMEOWNERS ASSOCIATION, INC. THE SUBJECT PROPERTY 1S CASTLE ROCK SUBDIVISION, PHASE 28. PROPERTY 1S ZONED PDD (PLANNED DEVELOPMENT DISTRICT). 2. THE TOTAL DISTURBED AREA FOR THIS PROJECT iS 0.103 ACRES (4501 SF). 3. THE SUBJECT TRACT DOES NOT UE WITHIN THE 100 YEAR FLOODPLAIN ACCORDING TO FEMA FLOOD INSURANCE RATE MAPS FOR BRAZOS COUNTY. TOM AND INCORPORATED AREAS. COMMUNITY NO. 480083, PANEL NO. 0325E, MAP NO. 48041CO325E, EFFECTIVE DATE: MAY 16. 2012. 4. CONTOURS SHOWN ARE FROM FIELD SURVEY DATA. S. ALL ELECTRICAL IMPROVEMENTS SHALL BE PER COLLEGE STATION UTILITIES SPECIFICATIONS AND PER THE COLLEGE STATION UTILITIES ELECTRICAL DESIGN FOR THIS PROJECT. ELECTRIC PROJECT COORDINATOR CiTY OF COLLEGE STATION UTILITIES 979-764-8314 6. THE SPLASH PAD SHALL BE A CLOSED PUMP AND FILTER SYSTEM WITH AN ISOLATION VALVE THAT CAN BE OPENED TO DISCHARGE WATER FROM THE CLOSED SYSTEM INTO THE SANITARY SEWER SERVICE UNE. THE ISOLATION VALVE SHALL REMAIN CLOSED TO PREVENT STORM WATER FROM ENTERING THE SANITARY SEWER SYSTEM. THE SPLASH PAD PUMP AND FILTER SYSTEM SHALL BE IN ACCORDANCE WiTH THE 2012 IPC, WHERE INDIRECT WASTE WITH AN AiR GAP IS REQUIRED FOR SWIMMING POOLS, BACKWASH FILTERS SYSTEMS. POOL DECKS, AND SIMILAR APPLICATIONS. LIKE THE SPLASH PAD. SECTION 802.2.1 OF THE 2012 IPC STATES, "THE 'AIR GAP' BETWEEN INDIRECT WASTE PIPE AND THE FLOOD LEVEL RIM OF THE WASTE RECEPTOR SHALL BE NOT LESS THAN TWICE THE EFFECTIVE OPENING OF THE INDIRECT WASTE PIPE'. THE WASTE RECEPTOR (SANITARY SEWER SERVICE INLET) SHALL BE TRAPPED AND PROTECTED FROM RAINFALL R.EVI TIED FOR COMPLIANCE AY 142015 W COL EGE STATION DEVEL PMENT SERVICES. PLAT FI ��ED: SITE & EROSIO CONTROL PLA REVI�WED Folm COmr�LIANC' ,, MAY 14 2015 COLLEGE STATION ENGINEERING VICINITY MAP N//LOCATION STATE iiiGiiWAY 9fl -VI'ILLIAM D. F1TCI4 PARKWAY 4�a NOT TO c AS"'I"LE ROCK AMENITY CENT SPLASH PAD ADDITION TOTAL AREA = 0.654 ACRES CASTLE ROCK SUBDiVION - PHASE 2B COMMON AREA (AMMENITY CENTER) 9117/118 ROMW STEVe* ON SUF&EY, A-54 COU.Ft1E STATi0P1, BWOS COUM . TEXAS SCALE: 1 "=20' MAY 2015 WNER/DEVELOPER: STLE ROCK HOMEOWNERS SOCIATION, INC. 1. BOX 9748 LLEGE STATION, TX 77845 SURVEYOR: BRAD KERR, RPLS NO. 4502 KERR SURVEYING, LLC 409 N. TEXAS AVENUE BRYAN, TX 77803 (979) 268-3195 ENGINEER: SC14ULTZ ENGINEERING, I.I.C. PO BOX 11995 COLLEGE STATION, TX 77842 (979)764-3900 SCALE VERTICAL N/A HORIZOS�ITAL 111=29 PLOTTING SCALE: 1:1 FILE NAME: 15-384 SHEET A If Curve Table CURVE iii LENGTH RADIUS DELTA TANGENT C14ORD CHORD DIRECTION C11 80.84' 480.00' 009'38'59` 40.52' 80.75' S66'45'04'E C12 28.39' 25.00' 06504'31' 15.95' 26.89' S82'49'45'W C13 246.32' 465.00' 03(r21'OS' 126.13' 243.45' N7W48'33"W R.EVI TIED FOR COMPLIANCE AY 142015 W COL EGE STATION DEVEL PMENT SERVICES. PLAT FI ��ED: SITE & EROSIO CONTROL PLA REVI�WED Folm COmr�LIANC' ,, MAY 14 2015 COLLEGE STATION ENGINEERING VICINITY MAP N//LOCATION STATE iiiGiiWAY 9fl -VI'ILLIAM D. F1TCI4 PARKWAY 4�a NOT TO c AS"'I"LE ROCK AMENITY CENT SPLASH PAD ADDITION TOTAL AREA = 0.654 ACRES CASTLE ROCK SUBDiVION - PHASE 2B COMMON AREA (AMMENITY CENTER) 9117/118 ROMW STEVe* ON SUF&EY, A-54 COU.Ft1E STATi0P1, BWOS COUM . TEXAS SCALE: 1 "=20' MAY 2015 WNER/DEVELOPER: STLE ROCK HOMEOWNERS SOCIATION, INC. 1. BOX 9748 LLEGE STATION, TX 77845 SURVEYOR: BRAD KERR, RPLS NO. 4502 KERR SURVEYING, LLC 409 N. TEXAS AVENUE BRYAN, TX 77803 (979) 268-3195 ENGINEER: SC14ULTZ ENGINEERING, I.I.C. PO BOX 11995 COLLEGE STATION, TX 77842 (979)764-3900 SCALE VERTICAL N/A HORIZOS�ITAL 111=29 PLOTTING SCALE: 1:1 FILE NAME: 15-384 SHEET A If J LOT 50 G� LOT 51 1 �r f ,jf,r�r� 1� l 0.162 ACRES PARKLAND 9117/118 t] LOT 52 20 10 0 20 SCALE IN FEET LOT 53 S s \ EXISTING CANOPY TREE TO BE REMOVED cn CASTLE ROCK PARKKNNTAY rn 70' ROW - 38' B-8 PAVEMENT WIDTH w ------------ I SHRUBS PROPOSED W g CANOPY TREE"�```�.� v r 3.5" CALIPER MINIMUM �tw4- PROPOSED \ CANOPY TREE O 3.5" CALIPER MINIMUM y LANDSCAPE PLAN LANDSCAPE LEGEND EXISTING CANOPY TREE (BURR OAK) 0 PROPOSED CANOPY TREE (LIVE OAK) 3.5" CALIPER MIN. O EXISTING SHRUB (SEA GREEN JUNIPER) Q PROPOSED SHRUB (SEA GREEN JUNIPER) REVIEWED FOR COMPLIANCE MAY 14 2015 COLLEGE ST^TION DEVELOPMENT SERVICES. PLAT FILED: THE SEAL APPEARING ON THIS DOCUMENT WAS AUTHORIZED BY Engineering,LLu DEEN L. DOYEN, P.E., ,".".1n;hmumItzU't LICENSE N0. 109835 2730 Langmlre, Suite A MAY 12, 2015. College station, Texas 77845 RELEASED FOR CONSTRUCTION 979.764.3900 TBPE NO. 12327 SURVEYED DESIGNED DRAWN APPROVED JOB NO. DATE KERR DLD DLD JPS 15-384 MAY 2015 IL DOYEN ... r ................... s 109835 4-CE0� FIRM 0 123 SCHULTZ ENGINEERING, LLC GRADING PLAN CASTLE ROCK AMENITY CENTER SPLASH PAD ADDITION CASTLE ROCK SUBDIVISION - PH 2B COMMON AREA (AMMENITY CENTER) - COLLEGE STATION, TX y W LANDSCAPE t GRADI-N-G PLA'� GRADING NOTES! t. FILL MATERIAL USED TO ACHIEVE GRADE IN AREAS TO RECEIVE PAVEMENT OR WITHIN THE STREET RIGHT-OF-WAY SHALL BE COMPACTED TO AT LEAST 98% OF THE MAXIMUM DRY DENSITY AS DETERMINED BY THE STANDARD PROCTOR TEST, (ASTM 0698). AT A MOISTURE CONTENT FROM OPTIMUM MOISTURE CONTENT TO 4X ABOVE THE OPTIMUM MOISTURE CONTENT. AREAS OUTSIDE OF THE STREET RIGHT-OF-WAY OR PAVEMENT AREAS SHALL BE COMPACTED TO 95x OF THE MAXIMUM DRY DENSITY. 2. THE SUBGRADE BENEATH THE CONCRETE SIDEWALKS SHALL BE 6' STABILIZED SUBGRADE OR SELECT FILL. 3. HANDICAP RAMP SLOPES SHALL NOT EXCEED AV -IV. 4. THE TOPOGRAPHY SHOWN IS FROM FIELD SURVEY DATA. 5. STRUCTURAL BACKFILL FOR UTILITY OR STORM DRAIN TRENCHES IS REQUIRED WHENEVER THE TRENCH IS WITHIN 5' OF PAVEMENT OR SIDEWALK. 6. THE CONTRACTOR SHALL FOLLOW THE GENERAL INTENT OF THE GRADING PLANS. MINOR ADJUSTMENTS TO THE ACTUAL ELEVATIONS SHOWN ON THE GRADING PLAN MAY BE REQUIRED TO MATCH EXISTING GROUND ELEVATIONS AND STRUCTURES. THE PROPOSED CONTOUR LINES SHOWN ARE APPROXIMATE ONLY, THE DESIGN GRADE SPOT ELEVATIONS SHOULD BE USED FOR CONSTRUCTION OF THE SITE WORK. 7. THE CONTRACTOR SHALL SALVAGE ALL TOPSOIL AND REPLACE IT ON ALL DISTURBED AREAS. ALL PARKING LOT ISLANDS AND AREAS ADJACENT TO PARKING AND SIDEWALK AREAS SHALL RECEIVE 6' SANDY LOAM TOPSOIL PRIOR TO PLACEMENT OF GRASS SOD OR HYOROMULCH. S. POSITIVE DRAINAGE AWAY FROM ALL SIDES OF THE PROPOSED BUILDING PAD SHALL BE PROVIDED. USE OF INTERCEPTOR DRAINAGE SWALES OR DRAINAGE PIPING SYSTEMS TO ROUTE STORMWATER AROUND AND NOT THROUGH THE BUILDING PAD AREA. S. THE SELECT FILL FOR THE BUILDING FOUNDATION SNAIL BE CONSTRUCTED IN ACCORDANCE WITH THE GEOTECHNICAL. REPORT. 10. THE UPPER PORTION OF ALL UTILITY EXCAVATIONS SHOULD BE BACKFILLED WITH PROPERLY COMPACTED CLAY SOILS TO MINIMIZE INFILTRATION OF SURFACE WATER. A CLAY "PLUG' SHOULD BE PROVIDED IN THE TRENCH ON THE EXTERIOR OF THE BUILDING TO PREVENT WATER FROM GAINING ACCESS ALONG THE 'TRENCH TO THE SUBGRADE BENEATH THE STRUCTURE. THE PLUG SHALL EXTEND TWO FEET BEYOND THE PIPE FACE IN ALL DIRECTIONS, AND A MINIMUM OF TWO FEET THICK. 11. REFER TO THE GEOTECHNICAL REPORT FOR DETAILED SPECIFICATIONS ON SUBGRADE. PAVEMENT, FOUNDATIONS, ETC. 12. ALL UNPAVED AREAS SHALL BE ADEQUATELY GRADED TO DRAIN, SO THAT NO PONDING OCCURS. 13. FINISH GRADE ADJACENT TO CURBING OR SIDEWALK SHAD. BE X" BELOW THE TOP OF CONCRETE AND 2° BELOW IN LANDSCAPING AREAS. 14. ADEQUATE DRAINAGE SHALL BE MAINTAINED AT ALL TIMES DURING CONSTRUCTION AND ANY DRAINAGE DITCH OR STRUCTURE DISTURBED DURING CONSTRUCTION SHALL BE RESTORED TO EXISTING CONDITIONS OR BETTER. 15. THE APPROVAL OF THESE PLANS IS NOT AN AUTHORIZATION TO GRADE ADJACENT PROPERTIES. WHEN FIELD CONDITIONS WARRANT OFF-SITE GRADING, PERMISSION MUST BE OBTAINED FROM THE AFFECTED PROPERTY OWNER($). ANY ADJACENT PROPERTY AND RIGHT-OF-WAY DISTURBED DURING CONSTRUCTION WILL BE RETURNED TO THBR EXISTING CONDITIONS OR BETTER. 16. THE DETENTION FACILITIES MUST BE CONSTRUCTED FIRST, 17. THE CONTRACTOR SHALL REFER TO THE STRUCTURAL ENGNEEWS PLANS FOR SPECIFICATIONS. PROCEDURES, AND REQUIREMENTS FOR THE BUILDING PAD. 18. EXISTING TREES. STUMPS, AND LARGE TREE SYSTEMS, SHALL BE GRUBBED AND REMOVED. VEGETATION SHALL BE REMOVED AND THE TOP 6-24 INCHES OF TOP SOIL AND SUB -GRADE BE STRIPPED FROM THE AREAS TO BE COVERED BY THE PROPOSED IMPROVEMENTS. 19. EXISTING DRAINAGE WAYS THAT ARE TO BE FILLED SHALL HAVE BENCHES EXCAVATED INTO THE SIDE WALLS OF THE CHANNEL PRIOR TO PLACEMENT OF FILL. BENCHES SHOULD BE AT LEAST 6 FEET IN WIDTH WITH ONE BENCH BEENG PLACED VERTICALLY FOR EVERY 2 FEET OF CHANNEL DEPTH. 20. MATERIAL EXCAVATED ON SITE, EXCLUDING THE TOP 6-24 INCHES OF TOP SOIL, MAY USED AS A FILL MATERIAL., UNDER PAVEMENT AREAS ONLY, IF THE MATERIAL IS FREE FROM TRASH, LUMPS, CLODS, ORGANIC SUBSTANCE, & OTHER FOREIGN MATTER AND SUSGRADE PREPARATION FILL MATERIA. PLACEMENT UNDER BUILDINGS SHALL BE IN ACCORDANCE WITH THE GEOTECHNICAL REPORT. 21. STABILIZED MATERIA. OR FILL MATERIAL $HALL BE PLACED IN EIGHT INCH MAXIMUM LOOSE LIFTS, WITH EACH LIFT WETTED OR DRIB TO A MOISTURE CONTENT RANGE OF OX TO +4X OF THE OPTIMUM MOISTURE CONTENT AND COMPACTED TO A UNIFORM DENSITY OF BOX (FOR STABILIZED) AND 95% (FOR GENERAL FILL) OF THE MAXIMUM DRY DENSITY AS DETERMINED BY ASTM D698. TP - TOP OF PAVEMENT TC - TOP OF CURB TW - TOP OF WALK TB - TOP OF BERM TG - TOP OF GROUND TRW - TOP OF RETAINING WALL LEGEND 280 PROPOSED CONTOUR -- — 230 — --- — EXISTING CONTOUR PROPERTY BOUNDARY ADJACENT PROPERTY BOUNDARY RIGHT OF WAY LOT LINE -- —PROPERTY SETBACK --- PROPOSED PUBLIC UTILITY EASEMENT — — — EXISTING PUBUC UTILITY EASEMENT PROPOSED PU6UC ACCESS EASEMENT EXISTING PUBLIC ACCESS EASEMENT PROPOSED LANDSCAPING EXISTING LANDSCAPING ME LIMITS OF DISTURBANCE PROPOSED CURB AND GUTTER EXISTING CURB AND GUTTER -i ---� FLOW ARROWS W-8 PROPOSED WATERLINE, SIZE NOTED W-8 EXISTING WATERLINE, SIZE NOTED S-8 EXISTING SANITARY SEWER UNE, SIZE NOTED UE UE EXISTING UNDERGROUND ELECTRIC UNE REVI�WEn FOR COMPLIANCE MAY 14 2015 COLLEGE STATION, ENGINEERIIV� C SCALE VERTICAL 1 "=4' HORIZONTAL 1°=40' PLOTTING SCALE: 1:1 FILE NAME: 15-384 SHEET c