Loading...
HomeMy WebLinkAboutDrawings�c r4 k A f o w -j 7t w V a V1.40� �� o N �a a W J w v,wcn n o CJ) u- oz Z w Q V A S 4J U4 (\(n I o a Z a �1 � J om�000 S r S k w�c rl 6 W_ Q ® a U. c: -0 -e 0 > TI) T u<± o a L rU-1 Chapter 4. Accessible Routes c E 0 (a) Front Approach, Pull Side r- - - - - - - - - - - - q I I I I I I I = I 36 min o Io 915 I I (c) Hinge Approach, Pull Side * If both closer and latch are provided ** 48 min (1220) if both closer and latch provided 12 min* 305 ----------� I I I I I I 22 min '� o I I 560 I I v�I I I I I I ------Mow I (e) Hinge Approach, Push Side ICC/ANSI A117.1-2003 *If both closer and latch are provided I I I I I I I I I= 12 min* I I I >= N 305 I I I I I Amv- I I I I ------ (b) Front Approach, Push Side (d) Hinge Approach, Pull Side *54 min 0 370) if closer is provided E CO v - r -----------i I �I Ire I (f) Latch Approach, Pull Side ------ - - - --I 14 I I I = 24 min E 610 i C -'j o I I ( LthA g) a c pproach, *48 min (1220) Push Side if closer is provided Fig. 404.2.3.1 Maneuvering Clearance at Manual Swinging Doors 18 ICC/ANSI A117.1-2003 Chapter 4. Accessible Routes Table 405.2—Allowable Ramp Dimensions for Construction in Existing Sites, Buildings, and Facilities Slope' Maximum Rise Steeper than 1:10 but not steeper than 1:8 3 inches (75 mm) Steeper than 1:12 but not steeper than 1:10 6 inches (150 mm) 'A slope steeper than 1:8 shall not be permitted. 405.6 Rise. The rise for any ramp run shall be 30 inches (760 mm) maximum. 405.7 Landings. Ramps shall have landings at bot- tom and top of each ramp run. Landings shall com- ply with Section 405.7. 405.7.1 Slope. Landings shall have a slope not steeper than 1:48 and shall comply with Sec- tion 302. 405.7.2 Width. Clear width of landings shall be at least as wide as the widest ramp run leading to the landing. 405.7.3 Length. Landings shall have a clear length of 60 inches (1525 mm) minimum. 405.7.4 Change in Direction. Ramps that change direction at ramp landings shall be sized to provide a turning space complying with Section 304.3. 405.7.5 Doorways. Where doorways are adja- cent to a ramp landing, maneuvering clear- ances required by Sections 404.2.3 and 404.3.2 shall be permitted to overlap the land- ing area. Where doors that are subject to lock- ing are adjacent to a ramp landing, landings shall be sized to provide a turning space com- plying with Section 304.3. 405.8 Handrails. Ramp runs with a rise greater than 6 inches (150 mm) shall have handrails com- plying with Section 505. 405.9 Edge Protection. Edge protection comply- ing with Section 405.9.1 or 405.9.2 shall be pro- vided on each side of ramp runs and at each side of ramp landings. EXCEPTIONS: 1. Ramps not required to have handrails where curb ramp flares complying with Section 406.3 are provided. 2. Sides of ramp landings serving an adjoin- ing ramp run or stairway. 3. Sides of ramp landings having a vertical drop—off of ,� inch (13 mm) maximum within 10 inches (255 mm) horizontally of the mini- mum landing area. 405.9.1 Extended Floor Surface. The floor surface of the ramp run or ramp landing shall extend 12 inches (305 mm) minimum beyond the inside face of a railing complying with Sec- tion 505. 60 min 1525 60 min 1525 landing F ramp run landing ast as wide as ramp run (a) Fig. 405.7 Ramp Landings 60 min 1525 ramp run LO landing F or ramp run E 23 ICC/ANSI A117.1-2003 to/ awns Fig. 505.4 Handrail Height (b) Ramps 505.7 Cross Section. Handrails shall have a cross section complying with Section 505.7.1 or 505.7.2. Chapter 5. General Site and Building Elements 11/2 min 38 Fig. 505.5 Handrail Clearance 505.9 Fittings. Handrails shall not rotate within their fittings. 505.7.1 Circular Cross Section. Handrails 505.10 Handrail Extensions. Handrails shall with a circular cross section shall have an out- extend beyond and in the same direction of stair side diameter of 1'/, inches (32 mm) minimum flights and ramp runs in accordance with Section and 2 inches (51 mm) maximum. 505.10. 505.7.2 Noncircular Cross Sections. Hand- rails with a noncircular cross section shall have a perimeter dimension of 4 inches (100 mm) minimum and 61/, inches (160 mm) maximum, and a cross-section dimension of 21/, inches (57 mm) maximum. 505.8 Surfaces. Handrails, and any wall or other surfaces adjacent to them, shall be free of any sharp or abrasive elements. Edges shall be rounded. 11/4-2 32-51 (a) Circular EXCEPTIONS: 1. Continuous handrails at the inside turn of stairs and ramps. 2. Extensions are not required for handrails in aisles serving seating where the handrails are discontinuous to provide access to seating and to permit crossovers within the aisle. 4 - 61/4 perimeter (b) Fig. 505.7 Handrail Cross Section 100-160 21/4 max 57 (c) Noncircular 43 Chapter 5. General Site and Building Elements 3. In alterations, full extensions of handrails shall not be required where such exten- sions would be hazardous due to plan con- figuration. 505.10.1 Top and Bottom Extension at Ramps. Ramp handrails shall extend horizontally above the landing 12 inches (305 mm) minimum beyond the top and bottom of ramp runs. Extensions shall return to a wall, guard, or floor, or shall be continu- ous to the handrail of an adjacent ramp run. 505.10.2 Top Extension at Stairs. At the top of a stairflight, handrails shall extend horizontally above the landing for 12 inches (305 mm) minimum begin- ning directly above the landing nosing. Extensions 12 min 305 ICC/ANSI A117.1-2003 shall return to a wall, guard, or the landing surface, or shall be continuous to the handrail of an adjacent stair flight. 505.10.3 Bottom Extension at Stairs. At the bot- tom of a stair flight, handrails shall extend at the slope of the stair flight for a horizontal distance equal to one tread depth beyond the bottom tread nosing. Extensions shall return to a wall, guard, or the landing surface, or shall be continuous to the handrail of an adjacent stair flight. 506 Windows Accessible windows shall have operable parts com- plying with Section 309. 12 min 305 Fig. 505.10.1 Top and Bottom Handrail Extensions at Ramps 12 min Fig. 505.10.2 Top Handrail Extensions at Stairs 44 Fig. 505.10.3 Bottom Handrail Extensions at Stairs N b U4 s S c -A S FA N 0 wZ CL V w a 40 � z� � J N a s C v w WU��� LU w w JcnU- z O C, z wtm 0p_aOzauS� � F- > U ED cr crr W ,t N aU-1 Z o o E C O a` ui t, O � C]. � C � ® � a vco W ,t N aU-1 Chapter 4. Accessible Routes r- - - - - - - - - -� I I I � I I I �E N � � I 18 min I 445 I 12 min*I I I I I .E o E N (a) Front Approach, Pull Side r ------------ I q> I I I (c) Hinge Approach, Pull Side * If both closer and latch are provided ** 48 min (1220) if both closer and latch provided 12 min* 305 ----------� * I I 122 min c LOI I I o I I 560 v I I I ( I I (e) Hinge Approach, Push Side ICC/ANSI A117.1-2003 *If both closer and latch are provided r--7------� I I I I I I I I I 12 min*I I I I I .E o E N 305 I I I I I I v I I I -41 (b) Front Approach, 1065 I I Push Side --------------- I I I I = • o E � 42 min —j I I I 1065 I I (d) Hinge Approach, Pull Side *54 min (1370) if closer is provided r -----------i I I I I C: o I 24 min E N I 610 o I I � I I I I I I (f) Latch Approach, Pull Side I _I I q I I I = 24 min I E 610 o (g) Latch Approach, *48 min (1220) Push Side if closer is provided Fig. 404.2.3.1 Maneuvering Clearance at Manual Swinging Doors 18 ICC/ANSI A117.1-2003 Chapter 4. Accessible Routes Table 405.2—Allowable Ramp Dimensions for Construction in Existing Sites, Buildings, and Facilities Slope' Maximum Rise Steeper than 1:10 but not steeper than 1:8 3 inches (75 mm) Steeper than 1:12 but not steeper than 1:10 6 inches (150 mm) 'A slope steeper than 1:8 shall not be permitted. 405.6 Rise. The rise for any ramp run shall be 30 inches (760 mm) maximum. 405.7 Landings. Ramps shall have landings at bot- tom and top of each ramp run. Landings shall com- ply with Section 405.7. 405.7.1 Slope. Landings shall have a slope not steeper than 1:48 and shall comply with Sec- tion 302. 405.7.2 Width. Clear width of landings shall be at least as wide as the widest ramp run leading to the landing. 405.7.3 Length. Landings shall have a clear length of 60 inches (1525 mm) minimum. 405.7.4 Change in Direction. Ramps that change direction at ramp landings shall be sized to provide a turning space complying with Section 304.3. 405.7.5 Doorways. Where doorways are adja- cent to a ramp landing, maneuvering clear- ances required by Sections 404.2.3 and 404.3.2 shall be permitted to overlap the land- ing area. Where doors that are subject to lock- ing are adjacent to a ramp landing, landings shall be sized to provide a turning space com- plying with Section 304.3. 405.8 Handrails. Ramp runs with a rise greater than 6 inches (150 mm) shall have handrails com- plying with Section 505. 405.9 Edge Protection. Edge protection comply- ing with Section 405.9.1 or 405.9.2 shall be pro- vided on each side of ramp runs and at each side of ramp landings. EXCEPTIONS: 1. Ramps not required to have handrails where curb ramp flares complying with Section 406.3 are provided. 2. Sides of ramp landings serving an adjoin- ing ramp run or stairway. 3. Sides of ramp landings having a vertical drop—off of ,� inch (13 mm) maximum within 10 inches (255 mm) horizontally of the mini- mum landing area. 405.9.1 Extended Floor Surface. The floor surface of the ramp run or ramp landing shall extend 12 inches (305 mm) minimum beyond the inside face of a railing complying with Sec- tion 505. 60 min 60 min 1525 1525 F _______T landing F ramp run landing ast as wide as ramp run (a) Fig. 405.7 Ramp Landings ramp run (b) 23 60 min 1525 ramp run landing E � r - ramp run (b) 23 ICC/ANSI A117.1-2003 �dj owlrs Fig. 505.4 Handrail Height (b) Ramps 505.7 Cross Section. Handrails shall have a cross section complying with Section 505.7.1 or 505.7.2. Chapter 5. General Site and Building Elements 11/2 min 38 Fig. 505.5 Handrail Clearance 505.9 Fittings. Handrails shall not rotate within their fittings. 505.7.1 Circular Cross Section. Handrails 505.10 Handrail Extensions. Handrails shall with a circular cross section shall have an out- extend beyond and in the same direction of stair side diameter of 11/4 inches (32 mm) minimum flights and ramp runs in accordance with Section and 2 inches (51 mm) maximum. 505.10. 505.7.2 Noncircular Cross Sections. Hand- rails with a noncircular cross section shall have a perimeter dimension of 4 inches (100 mm) minimum and 61/4 inches (160 mm) maximum, and a cross-section dimension of 21/4 inches (57 mm) maximum. 505.8 Surfaces. Handrails, and any wall or other surfaces adjacent to them, shall be free of any sharp or abrasive elements. Edges shall be rounded. 11/4-2 32-51 (a) Circular EXCEPTIONS: 1. Continuous handrails at the inside turn of stairs and ramps. 2. Extensions are not required for handrails in aisles serving seating where the handrails are discontinuous to provide access to seating and to permit crossovers within the aisle. 4- 100-160 - (b) Fig. 505.7 Handrail Cross Section 100-160 21/4 max 57 (c) Noncircular 43 Chapter 5. General Site and Building Elements 3. In alterations, full extensions of handrails shall not be required where such exten- sions would be hazardous due to plan con- figuration. 505.10.1 Top and Bottom Extension at Ramps. Ramp handrails shall extend horizontally above the landing 12 inches (305 mm) minimum beyond the top and bottom of ramp runs. Extensions shall return to a wall, guard, or floor, or shall be continu- ous to the handrail of an adjacent ramp run. 505.10.2 Top Extension at Stairs. At the top of a stairflight, handrails shall extend horizontally above the landing for 12 inches (305 mm) minimum begin- ning directly above the landing nosing. Extensions 12 min 305 12 min ICC/ANSI All 17.1-2003 shall return to a wall, guard, or the landing surface, or shall be continuous to the handrail of an adjacent stair flight. 505.10.3 Bottom Extension at Stairs. At the bot- tom of a stair flight, handrails shall extend at the slope of the stair flight for a horizontal distance equal to one tread depth beyond the bottom tread nosing. Extensions shall return to a wall, guard, or the landing surface, or shall be continuous to the handrail of an adjacent stair flight. 506 Windows Accessible windows shall have operable parts com- plying with Section 309. 12 min 305 Fig. 505.10.1 Top and Bottom Handrail Extensions at Ramps Fig. 505.10.2 Top Handrail Extensions at Stairs 44 Fig. 505.10.3 Bottom Handrail Extensions at Stairs