HomeMy WebLinkAboutREScheckREScheck Compliance Certificate
2003 IECC
REScheck Software Version 3.6 Release2
Data filename: C:\Program Files\Check\REScheck\Giese Rescheck.rck
PROJECT TITLE: Giese Residence
CITY: College Station
STATE: Texas
HDD: 1788
CONSTRUCTION TYPE: Single Family
WINDOW / WALL RATIO: 0.13
DATE: 01/08/08
DATE OF PLANS: 01.08.08
PROJECT DESCRIPTION:
Lot 9R
Block 2
University Preserve Subdivision
1016 Sanctuary Court
DESIGNER/CONTRACTOR:
Mike Keathley
COMPLIANCE: Passes
Maximum UA = 1879
Your Home UA = 1277
32.0% Better Than Code (LTA)
Maximum SHGC = 0.40
Your SHGC = 0.35
Ceiling 1 FF: Flat Ceiling or Scissor Truss
Ceiling 2 SF: Flat Ceiling or Scissor Truss
Wall 1 FF: Wood Frame, 16" o. c.
Window 1 FF FIXED: Metal Frame:Double Pane with Low -E
SHGC: 0.33
Window 2 FF SH: Metal Frame:Double Pane with Low -E
SHGC: 0.34
Door l: Solid
Door 2: Glass
SHGC: 0.40
Permit Number
Checked By/Date
Gross
Glazing
Area or
Cavity
Cont.
or Door
Perimeter R -Vali e
R -Val
g U -Factor
UA
2818
30.0
0.0
99
744
30.0
0.0
26
3910
13.0
0.0
269
3,0
0.520
157
157
0.650
102
24
0.400
10
144
0.400
58
Wall 2 SF: Wood Frame, 16" o.c. 1440
13.0 0.0 110
Window 3 SH copy 1: Metal Frame:Double Pane with Low -E 44
0.650 29
SHGC: 0.34
Door 3: Solid 20
0.400 8
Door 4 copy 1: Glass 33
0.400 13
SHGC: 0.40
Floor 1: Slab-On-Grade:Unheated 380
0.0 396
Insulation depth: 0.0'
Furnace 1: Forced Hot Air, 80 AFUE
Air Conditioner 1: Electric Central Air, 14 SEER
COMPLIANCE STATEMENT: The proposed building design described here is consistent with the building plans,
specifications, and other calculations submitted with the permit application.
The proposed building has been designed to
meet the 2003 IECC requirements in REScheck Version 3.6 Release 2 (formerly
MECcheck) and to comply with the
mandatory requirements listed in the REScheck Inspection Checklist.
Builder/Designer
Date