%, The ASP Extruded Aluminum Canopy System
A R C H I T E C T U R A L. has been engineered to maximize efficiency
s H A D E of production, thus providing an excellent value
P R o D U C T s while still allowing a wide range of attractive
design options. We combine structural
channels, tubes and angles to fabricate virtually
any fascia design. Canopies feature integrated
gutters with your choice of downspouts or scuppers.
Canopies can be cantilevered from building walls or
-- , '''''' , 01
x
I. 1
, . _____,_
,, , .
.._ . . . ,.
N ,,,, IR) 1 I ' F
ar
j _
` 'i ..�
r
.g
2
N- `, Also available
N A , with translucent
'.0:::,,,r:!�i1'7 y `V . vinyl fabric featuring
10-yr warranty!
A ,J11 .„ 46010 t»..
•
IIIIM
'It `14111111i
,, ,;,,,,." '-i,„1',1::E 1 f a 5.
Zl •79 V' 1 - ,.,may.
afeli •....,
supported by adjustable hanger rods.
Hanger rod mounting plates come in a i
variety of standard precision machined
designs, or can be engineered to your
own custom specification. Finish
/ , 14.
choices include TGIC Polyester
powder coating, anodizing and
fluoropolymer coatings with
warranties up to 20 yrs. 0. •#°.**°°°°':,.....,..00.1°I/e**..#°:„ ...,,11/
00,000.°<:.00 .../., ..:,,,•.°°0000•0,.- .
Decorative Aurum
�'
Wall Plate
1:011r70 A
DOPals w/
Adjustable Jaw Stile Ends
Extruded Amp Gutter
J25 thick
Prefabricated Components Help
Exuded Alarm Shorten Your Construction Schedule
12e •CainopyBotdy:Complete Welded Assembly,Including
Fascia and Integrated Perimeter Gutter with Scuppers or
Structural Chard Downspouts
i Fascia •Pre-cut Aluminum Decking Panels
• Support Rods: With Jaw Style Adjustable End and Pins
1,11111111= -
for Connection to Wall Plates and Canopy Body
• Wall Plates:Pre-Drilled for Wall Fasteners and Clews Pins
3
7 r
k
, ate►
;
-.'Sf
�
sii
III 111111i
III 11; I U I
i
ASP Extruded Aluminum Canopies
are substantial and built to last. They
are made of 6063-T6 aluminum
rods are available in both
I (hanger
- .
steel and aluminum). They are
i-al" �' decked with our .078 inch thick
,, t ill In.
t interlocking pans which appear flush
_ _ when viewed from beneath.
Fascia material choices include
Aluminum Association
Strtuctural channel up to 12" tall.
T Jrri
i j 0
b.n ,il.
[ , v Y 'b t ♦t
\ik\
\`' why y , . .j
--K _ i3.201 s
` . .. 2 I ,
cz
ra y
4*
MIIIIIIIII + ► 1
t / , A
'/ ��'tfff
,1 , ' /*/
/ •. ,,..
I�� �
i
s
J
____..--- "---7,; 1 *Ifii
. ,++ +
• THE LOOK OF I . ,,:,
STRUCTURAL STEEL, . ` .
WITHOUT THE RUST
• HIGH LEVEL OF FINISH �� o n
UNACHIEVABLE WITH n
■
LI rte■ 1 El \
FIELD APPLIED PAINT 1 I =1
• PREFABRICATED IN .
MAJOR COMPONENTS i .`
FOR QUICK INSTALLATION .__ ! 4T
1 k
ter.
0011
i • :POSH NAIL&SPA
f
ov
pi's
Py - , " '
� 5
•
Multiple Fascia Options:
Shown are just a small sample of the fascia design Choose Channel In or Out ...
possibilities. Please feel free to contact us if you'd
like assistance in designing a fascia style not shown. • 6-inch face • 8-inch face • 10-inch
face • 12-inch face • Custom sizes
Fascia Channel Facing Out
. ,„.„ ---- it-- N
N
/ \ / \\
1 I I
Fascia Channel Facing Out // //
with Bottom Trim s. 7
... or a Custom Fascia Style
• Combine our structural channel with various
Fascia Channel Facing Out angles and tube shapes to create your own unique
with Top Trim fascia profile in almost any configuration
i
/
/
// \\ / o \\
1
Smooth Fascia Surface 1I
Channel Facing In �/ I /
N
N
Fascia Channel Facing In ,
with Top Trim n \,
ilIllgIIIIIIIr
11 1
'
Fascia Channel Facing In -_-. -
with Top and Bottom Trim /' �\ / �\
i \1 �1 \ti
WON
I 1 1 1
i
6
Extruded Aluminum Decking STANDARD POWDER COAT COLORS
�'�engineeredto span up too,`1b'` many custom powder colors are also available as well as
Decking Section \
RAL 9001 CREAMY BEIGE RAL 7042 CADET GREY
RAL 1001 SANDSTONE 49-99999 METALLIC SILVER
-:,..,-I; Mil =
RAL 8004 TERRA COTTA RAL 7022 SLATE GREY
1
, 1 = I=
. RAL 6013 OLIVE GREEN RAL 9005 MIDNIGHT
i
• •
d A
11111. ME
Y RAL 6009 FOREST GREEN RAL 8019 DARK BROWN
• •
Square Bracket = =
II
'.
RAL 5001 PACIFIC BLUE RAL 8014 CHOCOLATE BROWN
6
''"' COLORS SHOWN ARE REPRESENTATIONS. REQUEST
• • ACTUAL POWDER COAT SAMPLES FOR PRECISE COLOR.
• PLEASE CONTACT ARCHITECTURAL SHADE
, '` • •
• PRODUCTS FOR ADDITIONAL FINISH OPTIONS
INCLUDING FLUOROPOLYMERS & ANODIZING
Circular Bracket
Rf
.§11111140 •
r
!L. + joTBrTt
:`'
1 1
: ,
•
I .-, rP*01°
/ . •
Diamond in Square
Shown are are standard hanger rod support brackets
machined from 1/2"thick aluminum. Don't see the exact look ,,,,e".
you had in mind? Contact ASP for a custom designed solution. 1
7
10530 PROTECTIVE COVERS 10 7316 CANOPIES
1.0 GENERAL -w.. ..
1.01 DESCRIPTION OF WORK
A Work in this section indudes fabrication and installation of ASP Extruded Aluminum Canopies as manufactured
by Architectural Shade Products,Kennesaw,GA 11
B. Related Items and Considerations
1. Plan for proper attachment to wall construction induding fastener type,size and locations.Coordinate nom" I y
for blocking or additional interior wall structure as required to support canopy loads.
2. Provide for water drainage through scuppers or downspouts per project drawings.
1.02 STANDARDS
A Products meeting these specifications and established standard of quality as required by Architectural Shade -- _
Products,Kennesaw,GA. 1 _ '
8. All work and materials shall conform to the following standards:
1. ASTM
2 American Welding Society
3. National Fire Protection Agency
4. National Association of Architectural Metal Manufacturers
C. Performance requirements
1. Canopy must conform to local building codes. r (.
D. Determine d specific load requirements have been established for canopies and if stamped calculations are
required for location in which canopy is installed.
E. Installer Qualifications:Must have at least 3 years experience in installation of canopies of type and installation
method similar to work in this section.
1.03 SUBMITTALS
A Shop Drawings
1. Drawings showing all frame dimensions
2 Canopy locations - 4
3. Connection Details
4. Product Information
C. Frame Finish
1. Manufacturer's color chart of specifiedcolor(s) •
1.04 WARRANTY(following warranty is based on standard powder coat finish) " a
A Canopy
1. Manufacturer shall warrant all manufacturer supplied components against defects in labor and �;•:t -�%'-'
materials for a period of one year commendng on the date of substantial completion.
B Installation
2. Installer shall warrant entire scope of installation induding connection of canopies to building,caulking �i I
or flashing of canopies and installation of decking panels,against defects in all labor and materials for aPt', E' ti
period of one year commendng on the date of substantial completion.
2.0 PRODUCTS •
._._
2.01 MANUFACTURERS
A Acceptable Manufacturer:Architectural Shade Products,2575-C Cobb International Blvd.,Kennesaw,GA
30152,toll free(877)723-2272,local(770)590-1230,fax:(770)590-8078,email rfi@archilecturalshade.com :z t
2.02 MATERIALS
A Decking shall be interlocking,self supporting(up to connection to gutters),6"wide pans,flat on underside with
1-3/4'tall nbs;shall be 6063-T6 extruded aluminum:shall be leak free;shall attach to gutters as to direct water
into gutter from each end.
B. Fascia to be 6063-T6 extruded aluminum structural channel and trims to match profiles indicated in project
drawings.
B. Gutters to be 6063-T6 extruded aluminum minimum 4"x 3-1/2"with minimum sidewall thickness of 1/8".Gutters
to form self-contained"loop"spanning back,sides and fronts of canopies. ARCHITECTURAL S HAD E
C. Hanger rods to be galvanized steel tube sized as required by applicable building codes or project documents,
PRODUCTS manufactures and installs
whichever is greater.Hanger rods to have adjustable jaw style galvanized steel ends.
D. Fasteners shall be noncorrosive,nonstaining bolts,shims and accessory items. awnings,canopies,and sun control devices
2.03 FRAME FINISH:Powder Coat Finish(following finish specification is based on standard powder coat finish)
A General that offer protection from the elements as
1. Canopies to be powder coated to comply with NAAMM's"Metal Finishes Manual for Architectural and well as visual enhancement for your building.
Metal Products".
B. Pre-Assembly
1. Before powder coating,canopyfasda/gutter assemblies shall be fully assembled,with welded joints. ARCHITECTURAL S HAD E
C. Coating performance
1. When tested in compliance with ASTM D 3363,coating shall withstand a min.gauge hardness of 2H. PRODUCTS works with a variety of
2. When tested in compliance with ASTM D 2794,pass up to 80 lbs.
3. Coated frame shall have a minimum salt spray resistance of 2000 hours,using ASTM B117,without loss materials,including aluminum and steel,
of paint adhesion. canvas and vinyl fabrics,standing seam
2.04 FABRICATION
A Aluminum Components and polycarbonate roofing.
1. To be joined by welding in compliance with ASW standards.All members to be cut so as to form tight
mints with no gaps.
2 Use clean,straight,smooth material that complies with approved plans and shop drawings. We also offer a variety of metal finishes,
B. Hanger Hardware including powder coating and anodizing.
1. Wall plates to be precision machined with bevelled edges and radiused Bevis plate as per
approved drawings and manufacturers product literature.
2 Hanger rods to be prefabricated assemblies straight and true,welded in compliance with ASW Contact us today and let us help you with the
standards.
C. Decking right ARCHITECTURAL SHADE
1. Decking panels to be prefinished,cut to length and width and marked for assembly.
3.0 EXECUTION PRODUCTS for your project.
3.01 INSPECTION
A Installer shall confirm dimensions pnor to fabrication. Since
Confirm surrounding area is ready for canopy installation. Since 19881
3.02 INSTALLATION
A Install canopies in positions indicated in manufacturer's shop drawings.
B. Installation shall he structurally sound,level,plumb and leak free.
C. Installer to protect finish during handling,erection and complete nstallalion.
07/2009
ARCHITECTURAL SHADE PRODUCTS
2575-C Cobb International Blvd. Kennesaw, GA 30152-tf 877.723.2272 '-p 770.590.1230
f770.590.8078-www.architecturalshade.com email: rfi@architecturalshade.com
DESCRIPTION ® S I .iEETWORKS "
The Streetworks Wal-Pak Series of wall luminaires provides traditional
architectural style with high performance energy efficient illumination. Catalog# Type
Rugged die-cast aluminum construction,stainless steel hardware along
with a sealed and gasketed optical compartment make the Wal-Pak
virtually impenetrable to contaminants.IP65 Rated.UL and cUL wet Project
location listed.TheWal-Pak wall luminaire is ideal for pathway
illumination,building entrances,vehicle ramps,schools,tunnels, Comments Date
stairways and loading docks.
Prepared by
SPECIFICATION FEATURES
Housing 277V with an operating are thermally optimized with 2400
Rugged one-piece die-cast temperature of-30°to 60°C. Wal- or 4000 lumen package modules.
aluminum housing and hinged, Pak LED systems maintain greater HID models are offered in -
removable die-cast aluminum door. than 70%of the initial light output horizontal medium or mogul-based
One-piece silicone gasket seals the after 50,000 hours of operation. UL metal halide or high pressure
optical chamber. UL 1598 wet listed HID high power factor sodium Iamps.T6 ceramic metal
location listed and IP65 ingress ballasts are Class H insulation rated halide and 4-pin compact
protection rated.Not (metal halide: 150,175,200,250, fluorescent lamp models offer high
recommended for car wash 320,350,400W[-30°C/-20°F],(high efficiency energy-saving
;;
applications. pressure sodium:50,70,100,150, illumination.
250,400W[-40°C/-40°F]. High
Electrical efficiency HID ballasts are available Door Assembly
Ballasts,LED driver and related in 120V,208V,240V,277V,347V and Single point,captive stainless steel *';%
electrical components are hard 480V.Compact fluorescent high hardware secures the removable
mounted to the die-cast housing power factor ballasts are Class P hinged door allowing for ease of
for optimal heat sinking and insulation rated for 120-277V and installation and maintenance.Door
operating efficiency. Wiring is have a starting temperature of- assembly is hinged at the bottom '''' . .a•, , ..
extended through a silicone gasket 18°C/0°F for easy removal,installation and
at the back of the housing.Three re-lamping, •
1/2"threaded conduit entry points Optical
allowforthru-branch wiring.LED Highly reflective anodized Finish
thermal management system aluminum reflectors provide high Housing and door are protected i'
incorporates both conduction and efficiency illumination.Optical with 5-stageTGIC dark bronze '
natural convection to transfer heat assemblies include impact resistant polyester powder coat paint. -11,.
rapidly away from LED source. borosilicate refractive glass, PremiumTGIC power coat finishes
Integral LED electronic driver Solite' flat diamond patterned withstand extreme climate changes
incorporates internal fusing glass and full cutoff IESNA while providing optimal color and WKP WAL-PAK
designed to withstand a 3kV surge compliant configurations. Patent gloss retention. Optional premium
test and is Class 2 rated for 120- pending,solid state LED luminaires colors are available. 2400-4000 Lumen LED
39-400W
High Pressure Sodium
Pulse Start Metal Halide
Metal Halide
Ceramic Metal Halide
DARK SKY FCO 32-140W
COMPLIANT Full °tt Compact Fluorescent
immimmmmmmmm
WALL MOUNT LUMINAIRE
DIMENSIONS TECHNICAL DATA
UL and cUL Wet Location Listed
BOROSILICATE FULL CUTOFF FL LENS IP65 Rated
40°C Maximum AmbientTemperature
,-,./7/:',,�, -. i��\' .%'�\: External Supply Wiring 90°C Minimum
1....,,-;
� \ moi EISA Cr),ARRA,Title 70 Compliant
10" 10
1254mm] [254mm] 1254mm10 ENERGY DATA] Reactor Ballast Input Watts
50W HPS NPF(58 Watts)
70W HPS NPF(82 Watts)
-'-" -- 100W HPS NPF(118 Watts)
16-5/8"1422mm] I 16-5/8"[422mm1 150W HPS NPF 175 Watts
---- -lEi-5/8"1422mmj I ( )
High Reactance Ballast Input Watts
50W MP HPF(69 Watts)
CIIII A:" �� �� 70W MP HPF(94 Watts)
100W MP HPF(129 Watts)
150W MP HPF(185 Watts)
CWA Ballast Input Watts
200W HPS HPF(250 Watts)
200W MP HPF(227 Watts)O
4",. _7-- --- — - �.4- 250WMPHPF(283Watts)it
L Small 11-3/8"1290mml_ L Small 151381 mml _I L Small 11-3/8"[290mm]_ 320W MP HPF(365 Watts)O
Large 12-6/8"1323mm] Large 16-2/8"1414mm] Large 12-6/8"[323mm] 350W MP HPF(400 Watts)O
400W HPS HPF(465 Watts)
400W MP HPF(452 Watts)O
/ SHIPPING DATA
COOPER Lighting Approximate Net Weight:
32-42 lbs.(15-19 kgs.) ADW100024
www.cooperlighting.com 2012-05-23 13:21:15
0 i WKP WAL-PAK
ORDERING INFORMATION
Sample Number:WKP10PC2GL
Product Family Lamp Lamp Type Ballast Type Voltage Door/Lens Type a Color Options
WKP=Wal-Pak Wattage M=Metal Halide C=CWI 2=120V GL=Borosilicate AP=Gray 1=Single Fuse(120,277 or 347V)'
LED' P=Pulse Start H=ReacJHPF 0=208V Glass Door BK=Black 2=Double Fuse,(208,240,48eV)7
2A=2 Package 28W Metal Halide N=Hi Reac./NPF 4=240V FL=Flat Solite BZ=Bronze 5=Non NEMA Photocontrol'
4A=4 Package 40W S=High Pressure P=Hi Reac./HPF 7=277V Glass Door WH=White B=Two Position Terminal Block
Metal Halide 2,3 Sodium R=Reac./NPS 8=480V (150-175W max) SGL=Solite Glass Lens-
17=175W LED=Solid State W=CWA W=Multi-tap FC=Full Cutoff for HID and CF Models'
25=250W Light E=Electronics wired 120V Door CGL=Clear Glass Lens 9
40=400W Emmiting N=Multi-tap PL=Polycarb L=Lamp Included
Pulse Start Metal Halide Diodes wired 277V Refractor
39=39W CM=Ceramic V=Multi-tap Door
50=50W Metal wired 240V 1175W max)
70=70W Halide U=Universal
10=100W CF=Compact (120-277V)
20=200W Fluorescent
15=150W
25=250W
32=320W
35=350W
40=400W
High Pressure Sodium
50=50W
70=70W
10=100W
15=150W
20=200W
25=250W
40=400W
Ceramic Metal Halide
39=39W
70=70W
100=100W
150=150W
Compact Fluorescent 4
32=32W
42=42W
57=57W
70=70W
64=12-32W)
84=12-42W)
114=12-57W)
140=(2-70W)
NOTES:1 LED Packages are 67 CRI/5000K
2 MH products available for non-US markets only.
3 MU and MP 175W and below are medium base all others are mogul base.250 end 350W MP are not Title 20 Compliant.400W MP must be ordered with Lamp option to be Title 20 Compliant.
4 Electronic Ballast Standard with CF.
5 Available with 70-150W Pulse Start or CM Lamps.
6 Small housing offered for 175W and below,CF and LED Models.Large Housing for 200-400W.FL Door not available with CF or 200-400W Models.
Polycarbonate lens available in models up to 175W max including LED.Polycarbonate lens not available with full cutoff door or FL models.Solite stipple glass is standard for FL lens.Clear glass
is standard for full cutoff door types except for LED.LED full cutoff door is standard with solite glass.
7 Specify voltage.1-120,277 or 347V,2-208 or 240V
8 SGL optional on HID and CF models only.
9 Clear Glass not available with LED.
LAMP TYPE WATTAGE
Pulse Start Metal Halide 50,70,100,150,200,250,320,350,400W
Metal Halide 175,250,400W
High Pressure Sodium 50,70,100,150,250,400W
T6 Ceramic Metal Halide 39,70,100,150W
Compact Fluorescent 0132,(11 42,(11 57,(11 70,(2132(2)42,(2)57,(2)70
LED 24=28W,4A=40W
COOPER00111
Lighting NOTE:Specifications and dimensions subject to change without notice.
Visit our web site at www.cooperlighting.com ADW100024