Loading...
HomeMy WebLinkAboutStaff Review Cowl' ( ate, CITY OF COITEGE STATION Home of Texas A&M Universitf' F MEMORANDUM DATE: December 9, 2014 TO: Bart Munro, via USPS; 7553 River Ridge Drive, College Station TX, 77845 FROM: Rachel Lazo, Planning Tech SUBJECT: RIVER PLACE PH 1 LOT 30-R, BLK 1 (MP) Staff reviewed the above-mentioned final plat as requested. The following page is a list of staff review comments detailing items that need to be addressed. One (1) 24"x36" copy of the revised final plat; New certified tax certificates submitted prior to the filing of the final plat; One (1) copy of the digital file of the final plat on diskette or e-mail to pdsdigitalsubmittalAcstx.gov; and The Mylar original of the revised final plat with the owner and County Judge's signatures (will be required after the County's approval). Upon receipt of the required documents, your project will be considered formally filed with the City of College Station. Please note that this application will expire in 90 days from the date of this memo, if the applicant has not provided written response comments and revised documents to the Administrator that seek to address the staff review comments contained herein. Please note that a Mylar original of the revised final plat will be required after Staff approval approval and prior to the filing of the plat. If you have any questions or need additional information, please call me at (979) 764-3570. Attachments: Staff Review Comments PC: Alan Munger, Brazos County, via email at RAMunger(a�brazoscountytx.gov McClure & Browne Engineering/Surveying Inc., via; kevinmmcclurebrowne.com P&DS Project No. 14-00900284 Planning c''Development Services P.O.BOX 9960 • 1101 TEXAS AVENUE •COLLEGE STATION •TEXAS •77842 TEL.979.764.3570 •FAX. 97.9.764.3496 cs tx.gov/d evs a rvi ces STAFF REVIEW COMMENTS NO. 1 Project: RIVER PLACE PH 1 LOT 30-R, BLK 1 (MP) - 14-00900284 PLANNING 1. Please note that you, the applicant, are responsible for scheduling the plat for consideration by the County Commissioner's Court and for getting the County Judge's signature on the Mylar after they approve the plat. 2. Please note that any changes made to the plans which have not been requested by the City of College Station must be explained in your next transmittal letter. Reviewed by: Rachel Lazo Date: December 8, 2014 BRAZOS COUNTY 1. Indicate City of College Station City Limits on Vicinity Map. 2. All development within the 100-year floodplain shall comply with all applicable orders and regulations, including but not limited to Brazos County's "Flood Damage Prevention Order." A floodplain development permit shall be obtained from the County Engineer's Office prior to the construction of any structure(s) within the floodplain. 3. Remove reference to Base Flood Elevation in Note 2. BFE's within a Zone A are subject to revision due to current best available information. 4. Provide Letter of Concurrence from Brazos County 911 that new addressing has been provided. (contact Mitchell Reeves) 5. Provide a completed Brazos County Plat Application to this department. 6. Title Block information may need to be indicative of an Amending Plat rather than a Replat. Reviewed by: Alan Munger Date: December 1, 2014 ENGINEERING COMMENTS NO. 1 1. Please tie property to a city of College Station horizontal control monument. 2. The metes & bound does not close. Reviewed by: Kevin Ferrer Date: December 4, 2014 FIRE 1. No comments at this time Reviewed by: Steve Smith Date: December 9, 2014 NOTE: Any changes made to the plans,that have not been requested by the City of College Station,must be explained in your next transmittal letter and"bubbled"on your plans.Any additional changes on these plans that have not been pointed out to the City,will constitute a completely new review. Page 2 of 2 CITY OF COLLEGE STATION Home of Texas A&M University � .. - MEMORANDUM DATE: November 24, 2014 TO: Bart Munro, via USPS; 7553 River Ridge Drive, College Station TX, 77845 FROM: Rachel Lazo, Planning Technician SUBJECT: RIVER PLACE PH 1 LOT 30-R, BLK 1 (MP) Thank you for the submittal of your Final Plat - Minor or Amending application. Kevin Ferrer, Graduate Engineer I, and I have been assigned to review this project. It is anticipated that the review will be completed and any staff comments returned to you on or before Wednesday, December 10, 2014. If you have questions in the meantime, please feel free to contact us. PC: McClure & Browne Engineering/Surveying Inc., via; kevinm@mcclurebrowne.com P&DS Project No. 14-00900284 Planning 6 Development Services P.O.BOX 9960 • 1101 TEXAS AVENUE •COLLEGE STATION •TEXAS •77842 TTL_ 979 764_iS7t) •FAX 979 7 i49A