Water System Report for Castlegate II Subdivision, Section 206 College Station, Texas December, 2014 Prepared By: Schultz Engineering, LLC TBPE Firm Registration No. 12327 2730 Longmire, Suite A College Station, Texas 77845 979.764.3900aF * 4Pit*T41"* P= L •i1# ********04.1.1040.104 1146044,40,4:44 4.44141:, -/ F-12327 SCHULTZ ENGINEERING, LLC. 124.acii 113Q General Information Location: The Castlegate II Subdivision, Section 206 is a 24.693-acre residential subdivision being developed immediately southeast of the existing Castlegate II Subdivision, Section 205 in College Station. The Final Plat shows a total of 52 lots in this section. General Note: An analysis was conducted on the entire Castlegate II water system to ensure its ability to serve all lots under fully developed conditions. This analysis was conducted with water line sizes of 8" or less to demonstrate that larger size lines are not necessary even though they may be required by the City for future development in the area. Refer to the report by Phillips Engineering titled " Water System Report For Castlegate II, Section 200 College Station, Texas",revised April 2011. Two analyses were conducted for Section 206 to demonstrate that it can function as a stand-alone system using water line sizes of 8" or less and the oversized 12" water line design required by the City for future development in the area. Primary Water Supply: Castlegate water service is provided by an existing 8" line on Victoria Avenue and an 8" line that lies in an easement in Section 7 of Castlegate. Section 200 was connected to each of these lines, and both lines will be used to provide looping in all future phases of the development. Section 206 connects to an existing 8" waterline that was constructed with Castlegate II Section 205. Land Use: Single family residential Design Criteria/Analysis Primary Water Supply: Existing 8"water line along Etonbury Avenue. Existing System Pressure Tests: Flow Hydrant-See Exhibit B Flowrate: 1,530 gpm Static Pressure: 90 psi Residual Pressure: 88 psi Exhibits: Exhibit Al —Water Layout—Minimum Required Line Sizes Exhibit A2—Water Layout—Oversized Lines Exhibit B—College Station Utilities Flow Test Report Exhibit C—Analysis Summary w/Minimum Required Line Sizes Exhibit D—Analysis Summary w/Oversized Lines Fire Flow: 1,000 gpm for Single Family Residential Domestic Use 1.5 gpm per lot for Single Family Residential Section 206— 52 Lots=78 gpm Existing Development(Section 205)—32 lots=48 gpm Future Development(Section 207)— 42 Lots= 63 gpm Total Domestic Demand= 189 gpm The proposed 12", 8", 6"&4"water lines are in accordance with the BCS Water Design Guidelines. This report provides the results of the water system analysis under the fire flow and domestic demand requirements,(1189 gpm)which produced the lowest pressure in the system. Water System Summary of Section 206 Summary of Calculations w/Minimum Required Line Sizes Pressure Min. 83.6 psi Domestic Demand Velocity Max. 1.22 fps Pressure Min. 80.3 psi Fire Flow Demand FH 3 Velocity Max. 11.62 fps Pressure Min. 74.7 psi Fire Flow Demand FH 4 Velocity Max. 11.69 fps Pressure Min. 76.2 psi Fire Flow Demand FH 5 Velocity Max. ( 11.62 fps Pressure Min. 72.6 psi Fire Flow Demand FH 6 Velocity Max. 7.60 fps w/Oversized Lines Pressure Min. 83.6 psi Domestic Demand Velocity Max. 1.22 fps Pressure Min. 80.3 psi Fire Flow Demand FH 3 Velocity Max. 11.62 fps Pressure Min. 74.7 psi Fire Flow Demand FH 4 Velocity Max. 11.69 fps Pressure Min. ` 76.2 psi Fire Flow Demand FH 5 Velocity Max. 11.62 fps Pressure Min. I 72.6 psi Fire Flow Demand FH 6 Velocity Max. ' 7.60 fps As shown above the system exceeds the minimum required pressures of 35 psi for domestic flow and 20 psi for fire flow in both analyses. The maximum velocity of 11.69 fps is less than the required maximum of 12 fps. Conclusion The proposed 12", 8", 6" and 4" water lines meet or exceed all of the design criteria for the City of College Station. They will provide adequate water pressure, flowrate and velocity for both domestic and fire flow demands. This could also be achieved using an 8"pipe in place of the oversized 12"pipe. EXHIBIT Al WATER LAYOUT- MINIMUM REQUIRED LINE SIZES EXHIBIT A2 WATER LAYOUT- OVERSIZED LINES EXHIBIT B COLLEGE STATION UTILITIES FLOW TEST REPORT EXHIBIT B College Station Utilities Reliable, Affordable,le, Communi ned Date test completed Tuesday October 9, 2012 Time completed 2:00 P.M. Test completed by VR LC Witness FA FLOW HYDRANT Location 4228 Camber Nozzle size 2.5 Hydrant number V-037 Pitot reading in PSI 82 Flow in G.P.M. 1530 STATIC HYDRANT Location 4214 Camber Hydrant number V-038 Static PSI 90 Residual PSI 88 Comments Requested EXHIBIT C PIPE & JUNCTION ANALYSIS- MINIMUM REQUIRED LINE SIZES Exhibit C WaterCAD Analysis Summary w/Minimum Required Line Sizes Pipe Analysis-Domestic Demand Hazen- Pipe Number Length(ft) Size(in) Material Flow(gpm) Velocity(ft/s) Williams C P-1 241 8 PVC 150 191 1.22 P-2 59 8 PVC 150 24 0.15 P-3 585 8 PVC 150 12 0.08 P-4 347 8 PVC 150 167 1.06 P-5 131 8 PVC 150 143 0.91 P-6 21 6 PVC 150 24 0.27 P-7 504 4 PVC 150 12 0.31 P-RES 12 8 PVC 150 191 1.22 P-9 129 8 PVC 150 143 0.91 P-10 308 8 PVC 150 119 0.76 P-11 307 8 PVC 150 59 0.37 P-12 559 8 PVC 150 35 0.22 P-13 8 8 PVC 150 35 0.22 P-14 69 8 PVC 150 2 0.01 P-15 659 8 PVC 150 2 0.01 P-16 20 6 PVC 150 24 0.27 P-17 504 4 PVC 150 12 0.31 P-18 111 8 PVC 150 -30 0.19 P-19 226 6 PVC 150 30 0.34 P-20 423 4 PVC 150 15 0.38 P-21 20 6 PVC 150 24 0.27 P-22 491 4 PVC 150 12 0.31 P-23 104 8 PVC 150 33 0.21 WaterCAD Analysis Summary w/Minimum Required Line Sizes Junction Analysis-Domestic Demand Junction Junction Elevation Demand Pressure(psi) (gpm) 1-1 316.39 0 89.8 J-2 318.41 0 88.8 FH-1 321.57 12 87.5 J-4 330.54 12 83.6 J-5 316.7 0 89.5 1-6 314.58 0 90.4 FH-2 316.82 12 89.5 J-8 321.85 12 87.3 J-9 314.65 0 90.4 J-10 313.28 0 90.9 1-11 313.85 0 90.7 FH-6 318.8 0 88.5 J-13 318.65 0 88.6 J-14 318 0 88.9 J-15 302 2 95.8 FH-3 314.57 12 90.4 J-17 315.08 12 90.1 1-18 315 30 90.2 11-1-4 311.76 15 91.6 1-20 313.52 15 90.8 FH-5 313.73 12 90.7 _ J-22 312.21 12 91.3 1-23 318.78 33 88.5 • Exhibit C WaterCAD Analysis Summary w/Minimum Required Line Sizes Pipe Analysis-Fire Flow Demand(FH-3) Pipe Length(ft) Size(in) Material Hazen- Flow(gpm) Velocity(ft/s) Number Williams C P-1 241 8 PVC 150 1,190 7.6 P-2 59 8 PVC 150 24 0.15 P-3 585 8 PVC 150 12 0.08 P-4 347 8 PVC 150 1,166 7.45 P-5 131 8 PVC 150 1,142 7.29 P-6 21 6 PVC 150 24 0.27 P-7 504 4 PVC 150 12 0.31 P-RES 12 8 PVC 150 1,190 7.6 P-9 129 8 PVC 150 1,142 7.29 P-10 308 8 PVC 150 119 0.76 P-11 307 8 PVC 150 59 0.37 P-12 559 8 PVC 150 35 0.22 P-13 8 8 PVC 150 35 0.22 P-14 69 8 PVC 150 2 0.01 P-15 659 8 PVC 150 2 0.01 P-16 20 6 PVC 150 1,024 11.62 P-17 504 4 PVC 150 12 0.31 P-18 111 8 PVC 150 -30 0.19 P-19 226 6 PVC 150 30 0.34 P-20 423 4 PVC 150 15 0.38 P-21 20 6 PVC 150 24 0.27 P-22 491 4 PVC 150 12 0.31 P-23 104 8 PVC 150 33 0.21 WaterCAD Analysis Summary w/Minimum Required Line Sizes Junction Analysis-Fire Flow Demand(FH-3) Junction Junction Elevation Demand Pressure (gpm) (psi) J-1 316.39 0 88.5 J-2 318.41 0 85.6 FH-1 321.57 12 84.2 J-4 330.54 12 80.3 J-5 316.7 0 83.5 J-6 314.58 0 83.4 FH-2 316.82 12 83.5 J-8 321.85 12 81.3 J-9 314.65 0 82.4 1-10 313.28 0 83 J-11 313.85 0 82.7 FH-6 318.8 0 80.6 J-13 318.65 0 80.6 1-14 318 0 80.9 1-15 302 2 87.8 FH-3 314.57 1,012 81.9 1-17 315.08 12 81.7 J-18 315 30 82.2 FH-4 311.76 15 83.6 1-20 313.52 15 82.8 FH-5 313.73 12 82.8 J-22 312.21 12 83.4 J-23 318.78 33 80.6 Exhibit C WaterCAD Analysis Summary w/Minimum Required Line Sizes Pipe Analysis-Fire Flow Demand(FH-4) Pipe Length(ft) Size(in) Material Hazen Flow(gpm) Velocity(ft/s) Number Williams C P-1 241 8 PVC 150 1,190 7.6 P-2 59 8 PVC 150 24 0.15 P-3 585 8 PVC 150 12 0.08 P-4 347 8 PVC 150 1,166 7.45 P-5 131 8 PVC 150 1,142 7.29 P-6 21 6 PVC 150 24 0.27 P-7 504 4 PVC 150 12 0.31 P-RES 12 8 PVC 150 1,190 7.6 P-9 129 8 PVC 150 1,142 7.29 P-10 308 8 PVC 150 1,118 7.14 P-11 307 8 PVC 150 59 0.37 P-12 559 8 PVC 150 35 0.22 P-13 8 8 PVC 150 35 0.22 P-14 69 8 PVC 150 2 0.01 P-15 659 8 PVC 150 2 0.01 P-16 20 6 PVC 150 24 0.27 P-17 504 4 PVC 150 12 0.31 P-18 111 8 PVC 150 -30 0.19 P-19 226 6 PVC 150 1,030 11.69 P-20 423 4 PVC 150 15 0.38 P-21 20 6 PVC 150 24 0.27 P-22 491 4 PVC 150 12 0.31 P-23 104 8 PVC 150 _ 33 0.21 WaterCAD Analysis Summary w/Minimum Required Line Sizes Junction Analysis-Fire Flow Demand(FH-4) Junction Junction Elevation Demand Pressure (gpm) (psi) 1-1 316.39 0 88.5 J-2 318.41 0 85.6 FH-1 321.57 12 84.2 J-4 330.54 12 80.3 J-5 316.7 0 83.5 J-6 314.58 0 83.4 FH-2 316.82 12 83.5 J-8 321.85 12 81.3 J-9 314.65 0 82.4 J-10 313.28 0 80.7 J-11 313.85 0 80.4 FH-6 318.8 0 78.3 J-13 318.65 0 78.4 1-14 318 0 78.6 J-15 302 2 85.6 FH-3 314.57 12 82.4 J-17 315.08 12 82.2 J-18 315 30 80 FH-4 311.76 1,015 75.5 J-20 313.52 15 74.7 FH-5 313.73 12 80.5 J-22 312.21 12 81.1 J-23 318.78 33 78.3 Exhibit C WaterCAD Analysis Summary w/Minimum Required Line Sizes Pipe Analysis-Fire Flow Demand(FH-5) Pipe Hazen Length (ft) Size(in) Material Flow(gpm) Velocity(ft/s) Number Williams C P-1 241 8 PVC 150 1,191 7.6 P-2 59 8 PVC 150 24 0.15 P-3 585 8 PVC 150 12 0.08 P-4 347 8 PVC 150 1,167 7.45 P-5 131 8 PVC 150 1,143 7.29 P-6 21 6 PVC 150 24 0.27 P-7 504 4 PVC 150 12 0.31 P-RES 12 8 PVC 150 1,191 7.6 P-9 129 8 PVC 150 1,143 7.29 P-10 308 8 PVC 150 1,118 7.14 P-11 307 8 PVC 150 1,058 6.76 P-12 559 8 PVC 150 35 0.22 P-13 8 8 PVC 150 35 0.22 P-14 69 8 PVC 150 2 0.01 P-15 659 8 PVC 150 2 0.01 P-16 20 6 PVC 150 24 0.27 P-17 504 4 PVC 150 12 0.31 P-18 111 8 PVC 150 -30 0.19 P-19 226 6 PVC 150 30 0.34 P-20 423 4 PVC 150 15 0.38 P-21 20 6 PVC 150 1,024 11.62 P-22 491 4 PVC 150 12 0.31 P-23 104 8 PVC 150 33 0.21 WaterCAD Analysis Summary w/Minimum Required Line Sizes Junction Analysis-Fire Flow Demand(FH-5) Junction Junction Elevation Demand Pressure (gpm) (Psi) J-1 316.39 0 88.5 J-2 318.41 0 85.6 FH-1 321.57 12 84.2 J-4 330.54 12 80.3 J-5 316.7 0 83.5 J-6 314.58 0 83.4 FH-2 316.82 12 83.5 J-8 321.85 12 81.3 J-9 314.65 0 82.4 J-10 313.28 0 80.7 J-11 313.85 0 78.4 FH-6 318.8 0 76.2 J-13 318.65 0 76.3 J-14 318 0 76.6 1-15 302 2 83.5 FH-3 314.57 12 82.4 J-17 315.08 12 82.2 J-18 315 30 80 FH-4 311.76 15 81.4 J-20 313.52 15 80.6 FH-5 313.73 1,012 77.9 J-22 312.21 12 78.6 J-23 318.78 33 76.2 Exhibit C WaterCAD Analysis Summary w/Minimum Required Line Sizes Pipe Analysis-Fire Flow Demand(FH-6) Pipe Hazen Length(ft) Size(in) Material Flow(gpm) Velocity(ft/s) Number Williams C P-1 241 8 PVC 150 1,191 7.6 P-2 59 8 PVC 150 24 0.15 P-3 585 8 PVC 150 12 0.08 P-4 347 8 PVC 150 1,167 7.45 P-5 131 8 PVC 150 1,143 7.29 P-6 21 6 PVC 150 24 0.27 P-7 504 4 PVC 150 12 0.31 _ P-RES 12 8 PVC 150 1,191 7.6 P-9 129 8 PVC 150 1,143 7.29 P-10 308 8 PVC 150 1,119 7.14 P-11 307 8 PVC 150 1,059 6.76 P-12 559 8 PVC 150 1,035 6.6 P-13 8 8 PVC 150 35 0.22 P-14 69 8 PVC 150 2 0.01 P-15 659 8 PVC 150 2 0.01 P-16 20 6 PVC 150 24 0.27 P-17 504 4 PVC 150 12 0.31 P-18 111 8 PVC 150 -30 0.19 P-19 226 6 PVC 150 30 0.34 P-20 423 4 PVC 150 15 0.38 P-21 20 6 PVC 150 24 0.27 P-22 491 4 PVC 150 12 0.31 P-23 104 8 PVC 150 33 0.21 WaterCAD Analysis Summary w/Minimum Required Line Sizes Junction Analysis-Fire Flow Demand(FH-6) Junction Junction Elevation Demand Pressure (gpm) (psi) J-1 316.39 0 88.5 J-2 318.41 0 85.6 FH-1 321.57 12 84.2 J-4 330.54 12 80.3 J-5 316.7 0 83.5 J-6 314.58 0 83.4 FH-2 316.82 12 83.5 J-8 321.85 12 81.3 J-9 314.65 0 82.4 J-10 313.28 0 80.7 J-11 313.85 0 78.4 FH-6 318.8 1,000 72.6 1-13 318.65 0 72.7 1-14 318 0 73 J-15 302 2 79.9 FH-3 314.57 12 82.4 J-17 315.08 12 82.2 1-18 315 30 80 FH-4 311.76 15 81.4 J-20 313.52 15 80.6 FH-5 313.73 12 78.4 J-22 312.21 12 79.1 J-23 318.78 33 72.6 EXHIBIT D PIPE & JUNCTION ANALYSIS - OVERSIZED LINES s Exhibit D WaterCAD Analysis Summary w/Oversized Lines Pipe Analysis-Domestic Demand Hazen- Pipe Number Length(ft) Size(in) Material Williams C Flow(gpm) Velocity(ft/s) P-1 241 8 PVC 150 191 1.22 P-2 59 8 PVC 150 24 0.15 P-3 585 8 PVC 150 12 0.08 P-4 347 8 PVC 150 167 1.06 P-5 131 8 PVC 150 143 0.91 P-6 21 6 PVC 150 24 0.27 P-7 504 4 PVC 150 12 0.31 P-RES 12 8 PVC 150 191 1.22 P-9 129 8 PVC 150 143 0.91 P-10 308 8 PVC 150 119 0.76 P-11 307 8 PVC 150 59 0.37 P-12 559 8 PVC 150 35 0.22 P-13 8 8 PVC 150 35 0.22 P-14 69 12 PVC 150 2 0 P-15 659 12 PVC 150 2 0 P-16 20 6 PVC 150 24 0.27 P-17 504 4 PVC 150 12 0.31 P-18 111 8 PVC 150 -30 0.19 P-19 226 6 PVC 150 30 0.34 P-20 423 4 PVC 150 15 0.38 P-21 20 6 PVC 150 24 0.27 P-22 491 4 PVC 150 12 0.31 P-23 104 12 PVC 150 33 0.09 WaterCAD Analysis Summary w/Oversized Lines Junction Analysis-Domestic Demand Junction Junction Elevation Demand Pressure(psi) (gpm) J-1 316.39 0 89.8 J-2 318.41 0 88.8 FH-1 321.57 12 87.5 J-4 330.54 12 83.6 J-5 316.7 0 89.5 J-6 314.58 0 90.4 FH-2 316.82 12 89.5 J-8 321.85 12 87.3 J-9 314.65 0 90.4 J-10 313.28 0 90.9 J-11 313.85 0 90.7 FH-6 318.8 0 88.5 J-13 318.65 0 88.6 J-14 318 0 88.9 J-15 302 2 95.8 FH-3 314.57 12 90.4 J-17 315.08 12 90.1 J-18 315 30 90.2 FH-4 311.76 15 91.6 J-20 313.52 15 90.8 FH-5 313.73 12 90.7 1-22 312.21 12 91.3 J-23 318.78 33 88.5 Exhibit D WaterCAD Analysis Summary w/Oversized Lines Pipe Analysis-Fire Flow Demand(FH-3) Pipe Hazen- Number Length(ft) Size(in) Material Williams C Flow(gpm) Velocity(ft/s) P-1 241 8 PVC 150 1,190 7.6 P-2 59 8 PVC 150 24 0.15 P-3 585 8 PVC 150 12 0.08 P-4 347 8 PVC 150 1,166 7.45 P-5 131 8 PVC 150 1,142 7.29 P-6 21 6 PVC 150 24 0.27 _ P-7 504 4 PVC 150 12 0.31 P-RES 12 8 PVC 150 1,190 7.6 P-9 129 8 PVC 150 1,142 7.29 P-10 308 8 PVC 150 119 0.76 P-11 307 8 PVC 150 59 0.37 P-12 559 8 PVC 150 35 0.22 P-13 8 8 PVC 150 35 0.22 P-14 69 12 PVC 150 2 0 P-15 659 12 PVC 150 2 0 P-16 20 6 PVC 150 1,024 11.62 P-17 504 4 PVC 150 12 0.31 P-18 111 8 PVC 150 -30 0.19 P-19 226 6 PVC 150 30 0.34 P-20 423 4 PVC 150 15 0.38 P-21 20 6 PVC 150 24 0.27 P-22 491 4 PVC 150 12 0.31 P-23 104 12 PVC 150 33 0.09 WaterCAD Analysis Summary w/Oversized Lines Junction Analysis-Fire Flow Demand(FH-3) Junction Junction Elevation Demand Pressure (gpm) (psi) J-1 316.39 0 88.5 J-2 318.41 0 85.6 FH-1 321.57 12 84.2 J-4 330.54 12 80.3 J-5 316.7 0 83.5 J-6 314.58 0 83.4 FH-2 316.82 12 83.5 J-8 321.85 12 81.3 J-9 314.65 0 82.4 J-10 313.28 0 83 J-11 313.85 0 82.7 FH-6 318.8 0 80.6 J-13 318.65 0 80.6 J-14 318 0 80.9 J-15 302 2 87.8 FH-3 314.57 1,012 81.9 J-17 315.08 12 81.7 1-18 315 30 82.2 FH-4 311.76 15 83.6 J-20 313.52 15 82.8 FH-5 313.73 12 82.8 J-22 312.21 12 83.4 1-23 318.78 33 80.6 0 Exhibit D WaterCAD Analysis Summary w/Oversized Lines Pipe Analysis-Fire Flow Demand(FH-4) Pipe Length(ft) Size(in) Material Hazen- Flow(gpm) Velocity(ft/s) Number Williams C P-1 241 8 PVC 150 1,190 7.6 P-2 59 8 PVC 150 24 0.15 P-3 585 8 PVC 150 12 0.08 P-4 347 8 PVC 150 1,166 7.45 P-5 131 8 PVC 150 1,142 7.29 P-6 21 6 PVC 150 24 0.27 P-7 504 4 PVC 150 12 0.31 P-RES 12 8 PVC 150 1,190 7.6 P-9 129 8 PVC 150 1,142 7.29 P-10 308 8 PVC 150 1,118 7.14 P-11 307 8 PVC 150 59 0.37 P-12 559 8 PVC 150 35 0.22 P-13 8 8 PVC 150 35 0.22 P-14 69 12 PVC 150 2 0 P-15 659 12 PVC 150 2 0 P-16 20 6 PVC 150 24 0.27 P-17 504 4 PVC 150 12 0.31 P-18 111 8 PVC 150 -30 0.19 P-19 226 6 PVC 150 1,030 11.69 P-20 423 4 PVC 150 15 0.38 P-21 20 6 PVC 150 24 0.27 P-22 491 4 PVC 150 12 0.31 P-23 104 12 PVC 150 33 0.09 WaterCAD Analysis Summary w/Oversized Lines Junction Analysis-Fire Flow Demand(FH-4) Junction Junction Elevation Demand Pressure (gpm) (psi) J-1 316.39 0 88.5 J-2 318.41 0 85.6 _ FH-1 321.57 12 84.2 1-4 330.54 12 80.3 J-5 316.7 0 83.5 J-6 314.58 0 83.4 FH-2 316.82 12 83.5 1-8 321.85 12 81.3 J-9 314.65 0 82.4 J-10 313.28 0 80.7 J-11 313.85 0 80.4 FH-6 318.8 0 78.3 J-13 318.65 0 78.4 J-14 318 0 78.6 J-15 302 2 85.6 FH-3 314.57 12 82.4 J-17 315.08 12 82.2 J-18 315 30 80 FH-4 311.76 1,015 75.5 1-20 313.52 15 74.7 FH-5 313.73 12 80.5 J-22 312.21 12 81.1 1-23 318.78 33 78.3 Exhibit D WaterCAD Analysis Summary w/Minimum Required Line Sizes Pipe Analysis-Fire Flow Demand(FH-5) Pipe Hazen- Number Length (ft) Size(in) Material Williams C Flow(gpm) Velocity(ft/s) P-1 241 8 PVC 150 1,191 7.6 P-2 59 8 PVC 150 24 0.15 P-3 585 8 PVC 150 12 0.08 P-4 347 8 PVC 150 1,167 7.45 P-5 131 8 PVC 150 1,143 7.29 P-6 21 6 PVC 150 24 0.27 _ P-7 504 4 PVC 150 12 0.31 P-RES 12 8 PVC 150 1,191 7.6 P-9 129 8 PVC 150 1,143 7.29 P-10 308 8 PVC 150 1,118 7.14 P-11 307 8 PVC 150 1,058 6.76 P-12 559 8 PVC 150 35 0.22 P-13 8 8 PVC 150 35 0.22 P-14 69 12 PVC 150 2 0 P-15 659 12 PVC 150 2 0 P-16 20 6 PVC 150 24 0.27 P-17 504 4 PVC 150 12 0.31 P-18 111 8 PVC 150 -30 0.19 P-19 226 6 PVC 150 30 0.34 P-20 423 4 PVC 150 15 0.38 P-21 20 6 PVC 150 1,024 11.62 P-22 491 4 PVC 150 12 0.31 P-23 104 12 PVC 150 33 0.09 WaterCAD Analysis Summary w/Minimum Required Line Sizes Junction Analysis-Fire Flow Demand(FH-5) Junction Demand Pressure Junction Elevation (psi) (gpm) J-1 316.39 0 88.5 J-2 318.41 0 85.6 FH-1 321.57 12 84.2 J-4 330.54 12 80.3 J-5 316.7 0 83.5 J-6 314.58 0 83.4 FH-2 316.82 12 83.5 J-8 321.85 12 81.3 J-9 314.65 0 82.4 J-10 313.28 0 80.7 J-11 313.85 0 78.4 FH-6 318.8 0 76.2 1-13 318.65 0 76.3 1-14 318 0 76.6 J-15 302 2 83.5 FH-3 314.57 12 82.4 1-17 315.08 12 82.2 1-18 315 30 80 FH-4 311.76 15 81.4 1-20 313.52 15 80.6 FH-5 313.73 1,012 77.9 1-22 312.21 12 78.6 J-23 318.78 33 76.2 Exhibit D WaterCAD Analysis Summary w/Minimum Required Line Sizes Pipe Analysis-Fire Flow Demand(FH-6) Pipe Hazen- Length (ft) Size(in) Material Williams C Flow(gpm) Velocity(ft/s) Number P-1 241 8 PVC 150 1,191 7.6 P-2 59 8 PVC 150 24 0.15 P-3 585 8 PVC 150 12 0.08 P-4 347 8 PVC 150 1,167 7.45 P-5 131 8 PVC 150 1,143 7.29 P-6 21 6 PVC 150 24 0.27 P-7 504 4 PVC 150 12 0.31 P-RES 12 8 PVC 150 1,191 7.6 P-9 129 8 PVC 150 1,143 7.29 P-10 308 8 PVC 150 1,119 7.14 P-11 307 8 PVC 150 1,059 6.76 P-12 559 8 PVC 150 1,035 6.6 P-13 8 8 PVC 150 35 0.22 P-14 69 12 PVC 150 2 0 P-15 659 12 PVC 150 2 0 P-16 20 6 PVC 150 24 0.27 P-17 504 4 PVC 150 12 0.31 P-18 111 8 PVC 150 -30 0.19 P-19 226 6 PVC 150 30 0.34 P-20 423 4 PVC 150 15 0.38 P-21 20 6 PVC 150 24 0.27 P-22 491 4 PVC 150 12 0.31 P-23 104 12 PVC 150 33 0.09 WaterCAD Analysis Summary w/Minimum Required Line Sizes Junction Analysis-Fire Flow Demand(FH-6) Junction Demand Pressure Junction Elevation (psi) (gpm) J-1 316.39 0 88.5 J-2 318.41 0 85.6 FH-1 321.57 12 84.2 J-4 330.54 12 80.3 J-5 316.7 0 83.5 J-6 314.58 0 83.4 FH-2 316.82 12 83.5 J-8 321.85 12 81.3 J-9 314.65 0 82.4 J-10 313.28 0 80.7 1-11 313.85 0 78.4 FH-6 318.8 1,000 72.6 J-13 318.65 0 72.7 J-14 318 0 73 J-15 302 2 79.9 FH-3 314.57 12 82.4 J-17 315.08 12 82.2 J-18 315 30 80 FH-4 311.76 15 81.4 J-20 313.52 15 80.6 FH-5 313.73 12 78.4 J-22 312.21 12 79.1 J-23 318.78 33 72.6 SCHULTZ ENGINEERING, LLC. 2730 Longmire Drive, Suite A College Station,Texas 77845 Firm No. 12327 Castlegate II Subdivision-Section 206 En.ineer's Estimate of Construction Estimated Unit Unit Price Total Description S uantit Item LS 1 $25,000.00 $ 25,000.00 1 Mobilization,Overhead and Construction Staking LS 1 $12,000.00 $ 12,000.00 2 Topsoil Removal and Replacement,complete in place LS 1 $ 8,000.00 $ 8,000.00 3 Pavement Striping and Markings,complete in place LS 3 $ 150.00 $ 450.00 4 Install End of Street Sips,complete in place 1 $ 5,000.00 $ 5,000.00 Erosion&Sediment Control-SWPPP Implementation&Maintenance,Silt Fence, LS 5 Construction Exit,Rock Filter Dam,etc.,complete in place SY 34,000 $ 0.50 $ 17,000.00 6 Hydroseed and Hydromulch,complete in place General Items Subtotal $ 67,450.00 Street Construction Items Concrete Pavement LS 1 $45,000.00 $ 45,000.00 7 Excavation&Grading,complete in place $ 2.20 $ 9,00460 8 Mixing&incorporation of lime,6" SY 4,093 . deep,complete in place SY ,085 $ 2.802 $ 19,838.000046 9 Mixing&incorporation of lime,8"deep,complete in place 183 $ $ 31,110.00 10 Hydrated Lime,complete in place(27 lb/sy fot 6"deep&361b/sy for 8"deep) Ton $ 170.0030.00 $ 311 S 11 6"Reinforced Concrete Pavement w/Curb,complete in place SY 6,3116,008 $ 40.006 $ 227,196.00240,320.00 12 7"Reinforced Concrete Pavement w/Curb,complete in place SF 22 620 $ 3.60 $ 81,432.00 13 Concrete Sidewalk&Ramps-4"thick,complete in place Street Construction Concrete Pavement Items Subtotal $ 653,900.60 14 dA I Pagelof4 la3• 4- 1 i. r, Castlegate II Subdivision-Section 206 Engineer's Estimate of Construction Estimated Item Description Unit Quantity Unit Price "Total Storm Sewer Construction Items 14 36"RCP Pipe,complete in place-Structural Backfill,complete in place LF 1,195 $ 80.00 $ 95,600.00 15 36"HDPE Pipe,complete in place-Structural Backfill,complete in place LF 250 $ 70.00 $ 17,500.00 16 36"HDPE Pipe,complete in place-Non-Structural Backfill,complete in place LF 313 $ 60.00 $ 18,780.00 I7 30"RCP Pipe,complete in place-Structural Backfill,complete in place LF 200 $ 70.00 $ 14,000.00 18 30"HDPE Pipe,complete in place-Structural Backfill,complete in place LF 212 $ 60.00 $ 12,720.00 19 30"HDPE Pipe,complete in place-Non-Structural Backfill,complete in place LF 1,118 $ 55.00 $ 61,512.00 20 24"RCP Pipe,complete in place-Structural Backfill,complete in place LF 250 $ 55.00 $ 13,750.00 21 24"HDPE Pipe,complete in place-Structural Backfill,complete in place LF 270 $ 40.00 $ 10,800.00 22 18"RCP Pipe,complete in place-Structural Backfill,complete in place LS 80 $ 45.00 $ 3,600.00 23 Curb Inlet- 10'wide,complete in place EA 13 $ 3,500.00 $ 45,500.00 24 Curb Inlet-5'wide,complete in place EA 7 $ 2,500.00 $ 17,500.00 25 Curb Inlet- 10'x8'wide,complete in place EA 1 $ 3,750.00 $ 3,750.00 26 Curb Inlet-5'x8'wide,complete in place EA 1 $ 2,750.00 $ 2,750.00 27 8'x4'Junction Box,complete in place EA 3 $ 3,000.00 $ 9,000.00 27 4'x4'Junction Box,complete in place EA 1 $ 2,500.00 $ 2,500.00 28 5'x3'Junction Box,complete in place EA t $ 2,750.00 $ 2,750.00 29 18"-6H:IV Concrete SET,complete in place EA 2 $ 1,500.00 $ 3,000.00 30 30"-6H:IV Concrete SET,complete in place EA 2 $ 2,500.00 $ 5,000.00 31 36"-611:I V Concrete SET,complete in place EA 3 $ 2,500.00 $ 7,500.00 32 TV Testing and Inspection,complete in place LF 3,888 $ 2.00 $ 7,776.80 Storm Sewer Construction Items Subtotal $ 355,288.80 Detention Pond B Construction Items 33 Pond Excavating and Grading,complete in place LS 1 $ 6,000.00 $6,000 34 15"-611:1 V Concrete SET,complete in place LS 2 $ 1,500.00 $3,000 35 15"HDPE Pipe,complete in place(Non-Structural) LF 80 $ 40.00 $3,200 36 4'Wide Concrete Flume,complete in place SF 3,710 $ 4.00 $14,840 37 Rock Riprop TNS 20 $ 50.00 $1,000 Detention Pond B Construction Items Subtotal $28,040 Page 2 of 4 Castlegate H Subdivision-Section 206 Engineer's Estimate of Construction Estimated Item Description Unit Unit Price Total Quantity Water Construction Items 38 12"C900 Water Pipe w/tracer wire-Non-Structural Backfill,complete in place LF 654 $ 35.00 $ 22,890.00 39 12"C900 Water Pipe w/tracer wire-Structural Backfill,complete in place LF 180 $ 40.00 $ 7,200.00 40 12"x 12"M.J.Tee,complete in place EA 1 $ 800.00 $ 800.00 41 12"M.J.Gate Valve,complete in place EA 2 $ 1,850,00 $ 3,700.00 42 12"x 8"M.J.Reducer,complete in place EA 1 $ 550.00 $ 550.00 43 12"x 45°M.J.Bend,complete in place EA 2 $ 650.00 $ 1,300.00 44 4"Blowoff Assembly,complete in place EA 2 $ 2,200.00 $ 4,400.00 45 Fire Hydrant Assembly(w/valve,vert.extension),complete in place EA 4 $ 3,500.00 $ 14,000.00 46 8"C900 Water Pipe w/tracer wire-Structural Backfill,complete in place LF 307 $ 28.00 $ 8,596.00 47 8"C900 Water Pipe w/tracer wire-Non-Structural Backfill,complete in place LF 1117 $ 23.00 $ 25,691.00 48 6"C900 Water Pipe w/tracer wire-Non-Structural Backfill,complete in place LF 265 $ 22.00 $ 5,830.00 49 4"C900 Water Pipe w/tracer wire-Structural Backfill,complete in place LF 300 $ 20.00 $ 6,000.00 50 4"C900 Water Pipe w/tracer wire-Non-Structural Backfill,complete in place LF 1117 $ 16.00 $ 17,872.00 51 8"x 8"M.J.Cross,complete in place EA 1 $ 600.00 $ 600.00 52 8"x 6"M.J.Tee,complete in place EA 3 $ 500.00 $ 1,500.00 53 6"x 6"M.J.Tee,complete in place EA 3 $ 450.00 $ 1,350.00 54 8"x 6"M.J.Reducer,complete in place EA 1 $ 350.00 $ 350.00 55 6"x 4"M.J.Reducer,complete in place EA 3 $ 300.00 $ 900.00 56 8"M.J.Gate Valve,complete in place EA 4 $ 1,250.00 $ 5,000.00 57 6"M.J.Gate Valve,complete in place EA 3 $ 1,000.00 $ 3,000.00 58 8"x 45°M.J.Bend,complete in place EA 12 $ 350.00 $ 4,200.00 59 4"x 45°M.J.Bend,complete in place EA 16 $ 200.00 $ 3,200.00 60 1"Water Service,< 15 ft(avg length=2 11)(4"Line) EA 2 $ 650.00 $ 1,300.00 61 1"Water Service,> 15 ft(avg length=48 ft)(4"Line) EA 8 $ 850.00 $ 6,800.00 62 1.5"Water Service,< 15 ft(avg length=2 ft)(4"Line) EA 11 $ 800.00 $ 8,800.00 63 1.5"Water Service,< 15 ft(avg length=2 ft)(6"Line) EA 1 $ 900.00 $ 900.00 64 1.5"Water Service,> 15 ft(avg length=48 ft)(4"Line) EA 8 $ 1,100.00 $ 8,800.00 65 1.5"Water Service,> 15 ft(avg length=48 ft)(6"Line) EA 1 $ 1,200.00 $ 1,200.00 66 2"Blowoff Assembly,complete in place EA 4 $ 1,000.00 $ 4,000.00 67 Connect to Existing 8"Water Line EA 1 $ 1,000.00 $ 1,000.00 68 Waterline Testing LS 1 $ 1,000.00 $ 1,000.00 Water Construction Items Subtotal $ 172,729.00 Page 3 of 4 Castlegate H Subdivision-Section 206 Engineer's Estimate of Construction Item Description Unit Estimated Unit Price Total Quantity Sanitary Sewer Construction Items 69 8"PVC Sewer Line-D3034-Structural Backfill,complete in place LF 827 $ 26.00 $ 21,502.00 70 8"PVC Sewer Line-D3034-Non-Structural Backfill,complete in place LF 1,309 $ 22.00 $ 28,798.00 71 8"PVC Sewer Line-ASTM D-2241-Structural Backfill,complete in place LF 60 $ 28.00 $ 1,680.00 72 6"PVC Sewer Line-D3034-Structural Backfill,complete in place LF 61 $ 20.00 $ 1,220.00 73 6"PVC Sewer Line-D3034-Non-Structural Backfill,complete in place LF 522 $ 16.00 $ 8,352.00 74 6"PVC Sewer Line-ASTM D-2241 -Structural Backfill,complete in place LF 20 $ 22.00 $ 440.00 75 4"Sewer Service-Single(avg.length=4ft),complete in place EA 7 $ 400.00 $ 2,800.00 76 4"Sewer Service-Double(avg length=4 ft),complete in place EA 7 $ 500.00 $ 3,500.00 77 4"Sewer Service-Single(avg length=48 ft),complete in place EA 9 $ 850.00 $ 7,650.00 78 4"Sewer Service-Double(avg length=48 ft),complete in place EA 11 $ 950.00 $ 10,450.00 79 Concrete Manhole-4'Dia.-complete in place EA 12 $ 2,950.00 $ 35,400.00 80 TV Testing and Inspection,complete in place LF 2,799 $ 2.50 $ 6,997.50 Sanitary Sewer Construction Items Subtotal $ 128,789.50 Lift-Station Access Road Items 81 Excavation&Grading,complete in place LS 1 $ 2,500.00 $ 2,500.00 82 Mixing&incorporation of lime,6"deep,complete in place SY 675 $ 2.50 $ 1,687.50 83 Hydrated Lime,complete in place(27 Ib/sy foot 6"deep&36 Ib/sy for 8"deep) Ton 9 $ 180.00 $ 1,620.00 84 Crushed Limestone Base Material-6"thick,complete in place SY 509 $ 12.00 $ 6,108.00 85 HMAC-Type D Pavement 2"thick-includes prime coat,complete in place SY 509 $ 13.00 $ 6,617.00 86 18"-6H:1V Concrete SET,complete in place LS 2 $ 1,500.00 $3,000 87 18"HDPE Pipe,complete in place(Non-Structural) LF 48 $ 35.00 $1,680 Lift-Station Access Road Items Subtotal $23,213 General Items Subtotal $ 67,450.00 Street Construction Concrete Pavement Items Subtotal $ 653,900.60 f4i,� ,...... Storm Sewer Construction Items Subtotal $ 355,288.80 ill( Detention Pond B Construction Items Subtotal $28,040 „ ti. Construction Items Subtotal $ 172,729.00 JOSEPH P. SCHULTZ. Sanitary Sewer Construction Items Subtotal $ 128,789.50 65889 h Lift-Station Access Road Items Subtotal $23,213 , a , TOTAL CONSTRUCTION $ 1,429,410.40 / / F-12327 rt.-Z -11' SN-ULTZ ENGINEERING, 1.1-G. Page 4 of 4 SCHULTZ ENGINEERING, LLC. 2730 Longmire Drive, Suite A College Station, Texas 77845 Firm No. 12327 Castlegate II Subdivision-Section 206 Engineer's Estimate of Construction Item Description Unit Estimated Unit Price Total Quantity General Items I Mobilization,Overhead and Construction Staking LS 1 $25,000.00 $ 25,000.00 2 Topsoil Removal and Replacement,complete in place LS 1 $12,000.00 $ 12,000.00 3 Pavement Striping and Markings,complete in place LS 1 $ 8,000.00 $ 8,000.00 4 Install End of Street Signs,complete in place LS 3 $ 150.00 $ 450.00 Erosion&Sediment Control-SWPPP Implementation&Maintenance,Silt Fence, 5 LS I $ 5,000.00 $ 5,000.00 Construction Exit,Rock Filter Dam,etc.,complete in place 6 Hydroseed and Hydromulch,complete in place SY 34,000 $ 0.50 $ 17,000.00 General Items Subtotal $ 67,450.00 Street Construction Items Concrete Pavement 7 Excavation&Grading,complete in place LS 1 $45,000.00 $ 45,000.00 8 Mixing&incorporation of lime,6"deep,complete in place SY 4,093 $ 2.20 $ 9,004.60 9 Mixing&incorporation of lime,8"deep,complete in place SY 7,085 $ 2.80 $ 19,838.00 10 Hydrated Lime,complete in place(27 Ib/sy fot 6"deep&36 Ib/sy for 8"deep) Ton 183 $ 170.00 $ 31,110.00 11 6"Reinforced Concrete Pavement w/Curb,complete in place SY 6,311 $ 36.00 $ 227,196.00 12 7"Reinforced Concrete Pavement w/Curb,complete in place SY 6,008 $ 40.00 $ 240,320.00 13 Concrete Sidewalk&Ramps-4"thick,complete in place SF 22,620 $ 3.60 $ 81,432.00 Street Construction Concrete Pavement Items Subtotal $ 653,900.60 Page 1 of 4 Castlegate II Subdivision-Section 206 Engineer's Estimate of Construction Item Description Unit Estimated Unit Price Total Quantity Storm Sewer Construction Items 14 36"RCP Pipe,complete in place-Structural Backfill,complete in place LF 1,195 $ 80.00 $ 95,600.00 15 36"HDPE Pipe,complete in place-Structural Backfill,complete in place LF 250 $ 70.00 $ 17,500.00 16 36"HDPE Pipe,complete in place-Non-Structural Backfill,complete in place LF 313 $ 60.00 $ 18,780.00 17 30"RCP Pipe,complete in place-Structural Backfill,complete in place LF 200 $ 70.00 $ 14,000.00 18 30"HDPE Pipe,complete in place-Structural Backfill,complete in place LF 212 $ 60.00 $ 12,720.00 19 30"HDPE Pipe,complete in place-Non-Structural Backfill,complete in place LF 1,118 $ 55.00 $ 61,512.00 20 24"RCP Pipe,complete in place-Structural Backfill,complete in place LF 250 S 55.00 $ 13,750.00 21 24"HDPE Pipe,complete in place-Structural Backfill,complete in place LF 270 $ 40.00 $ 10,800.00 22 18"RCP Pipe,complete in place-Structural Backfill,complete in place LS 80 $ 45.00 $ 3,600.00 23 Curb Inlet- 10'wide,complete in place EA 13 $ 3,500.00 $ 45,500.00 24 Curb Inlet-5'wide,complete in place EA 7 $ 2,500.00 $ 17,500.00 25 Curb Inlet- 10'x8'wide,complete in place EA 1 $ 3,750.00 $ 3,750.00 26 Curb Inlet-5'x8'wide,complete in place EA 1 $ 2,750.00 $ 2,750.00 27 8'x4'Junction Box,complete in place EA 3 $ 3,000.00 $ 9,000.00 27 4'x4'Junction Box,complete in place EA 1 $ 2,500.00 $ 2,500.00 28 5'x3'Junction Box,complete in place EA 1 $ 2,750.00 $ 2,750.00 29 18"-6H:1 V Concrete SET,complete in place EA 2 $ 1,500.00 $ 3,000.00 30 30"-6H:1 V Concrete SET,complete in place EA 2 $ 2,500.00 $ 5,000.00 31 36"-61-1:IV Concrete SET,complete in place EA 3 $ 2,500.00 $ 7,500.00 32 TV Testing and Inspection,complete in place LF 3,888 $ 2.00 $ 7,776.80 Storm Sewer Construction Items Subtotal $ 355,288.80 Detention Pond B Construction Items 33 Pond Excavating and Grading,complete in place LS 1 $ 6,000.00 $6,000 34 15"-6H:1V Concrete SET,complete in place LS 2 $ 1,500.00 $3,000 35 15"HDPE Pipe,complete in place(Non-Structural) LF 80 $ 40.00 $3,200 36 4'Wide Concrete Flume,complete in place SF 3,710 $ 4.00 $14,840 37 Rock Riprop TNS 20 $ 50.00 $1,000 Detention Pond B Construction Items Subtotal $28,040 Page 2 of 4 Castlegate II Subdivision-Section 206 Engineer's Estimate of Construction Item Description Unit Estimated Unit Price Total Quantity Water Construction Items 38 12"C900 Water Pipe w/tracer wire-Non-Structural Backfill,complete in place LF 654 $ 35.00 $ 22,890.00 39 12"C900 Water Pipe w/tracer wire-Structural Backfill,complete in place LF 180 $ 40.00 $ 7,200.00 40 12"x 12"M.J.Tee,complete in place EA 1 $ 800.00 $ 800.00 41 12"M.J.Gate Valve,complete in place EA 2 $ 1,850.00 $ 3,700.00 42 12"x 8"M.J.Reducer,complete in place EA 1 $ 550.00 $ 550.00 43 12"x 45°M.J.Bend,complete in place EA 2 $ 650.00 $ 1,300.00 44 4"Blowoff Assembly,complete in place EA 2 S 2,200.00 $ 4,400.00 45 Fire Hydrant Assembly(w/valve,vert.extension),complete in place EA 4 $ 3,500.00 $ 14,000.00 46 8"C900 Water Pipe w/tracer wire-Structural Backfill,complete in place LF 307 $ 28.00 $ 8,596.00 47 8"C900 Water Pipe w/tracer wire-Non-Structural Backfill,complete in place LF 1117 $ 23.00 $ 25,691.00 48 6"C900 Water Pipe w/tracer wire-Non-Structural Backfill,complete in place LF 265 $ 22.00 $ 5,830.00 49 4"C900 Water Pipe w/tracer wire-Structural Backfill,complete in place LF 300 $ 20.00 $ 6,000.00 50 4"C900 Water Pipe w/tracer wire-Non-Structural Backfill,complete in place LF 1117 $ 16.00 $ 17,872.00 51 8"x 8"M.J.Cross,complete in place EA 1 $ 600.00 $ 600.00 52 8"x 6"M.J.Tee,complete in place EA 3 $ 500.00 $ 1,500.00 53 6"x 6"M.J.Tee,complete in place EA 3 $ 450.00 $ 1,350.00 54 8"x 6"M.J.Reducer,complete in place EA 1 $ 350.00 $ 350.00 55 6"x 4"M.J.Reducer,complete in place EA 3 $ 300.00 $ 900.00 56 8"M.J.Gate Valve,complete in place EA 4 $ 1,250.00 $ 5,000.00 57 6"M.J.Gate Valve,complete in place EA 3 $ 1,000.00 $ 3,000.00 58 8"x 45°M.J.Bend,complete in place EA 12 $ 350.00 $ 4,200.00 59 4"x 45°M.J.Bend,complete in place EA 16 $ 200.00 $ 3,200.00 60 1"Water Service,< 15 ft(avg length=2 ft)(4"Line) EA 2 $ 650.00 $ 1,300.00 61 1"Water Service,> 15 ft(avg length=48 ft)(4"Line) EA 8 $ 850.00 $ 6,800.00 62 1.5"Water Service,< 15 ft(avg length=2 ft)(4"Line) EA 11 $ 800.00 $ 8,800.00 63 1.5"Water Service,< 15 ft(avg length=2 ft)(6"Line) EA 1 $ 900.00 $ 900.00 64 1.5"Water Service,> 15 ft(avg length=48 ft)(4"Line) EA 8 $ 1,100.00 $ 8,800.00 65 1.5"Water Service,> 15 ft(avg length=48 ft)(6"Line) EA 1 $ 1,200.00 $ 1,200.00 66 2"Blowoff Assembly,complete in place EA 4 $ 1,000.00 $ 4,000.00 67 Connect to Existing 8"Water Line EA 1 $ 1,000.00 $ 1,000.00 68 Waterline Testing LS 1 $ 1,000.00 $ 1,000.00 Water Construction Items Subtotal $ 172,729.00 Page 3 of 4 Castlegate II Subdivision-Section 206 Engineer's Estimate of Construction Item Description Unit Estimated Unit Price Total Quantity Sanitary Sewer Construction Items 69 8"PVC Sewer Line-D3034-Structural Backfill,complete in place LF 827 $ 26.00 $ 21,502.00 70 8"PVC Sewer Line-D3034-Non-Structural Backfill,complete in place LF 1,309 $ 22.00 $ 28,798.00 71 8"PVC Sewer Line-ASTM D-2241 -Structural Backfill,complete in place LF 60 $ 28.00 $ 1,680.00 72 6"PVC Sewer Line-D3034-Structural Backfill,complete in place LF 61 $ 20.00 $ 1,220.00 73 6"PVC Sewer Line-D3034-Non-Structural Backfill,complete in place LF 522 $ 16.00 $ 8,352.00 74 6"PVC Sewer Line-ASTM D-2241-Structural Backfill,complete in place LF 20 $ 22.00 $ 440.00 75 4"Sewer Service-Single(avg.length=4ft),complete in place EA 7 $ 400.00 $ 2,800.00 76 4"Sewer Service-Double(avg length=4 ft),complete in place EA 7 $ 500.00 $ 3,500.00 77 4"Sewer Service-Single(avg length=48 ft),complete in place EA 9 $ 850.00 $ 7,650.00 78 4"Sewer Service-Double(avg length=48 ft),complete in place EA 11 $ 950.00 $ 10,450.00 79 Concrete Manhole-4'Dia.-complete in place EA 12 $ 2,950.00 $ 35,400.00 80 TV Testing and Inspection,complete in place LF 2,799 $ 2.50 $ 6,997.50 Sanitary Sewer Construction Items Subtotal $ 128,789.50 Lift-Station Access Road Items 81 Excavation&Grading,complete in place LS 1 $ 2,500.00 $ 2,500.00 82 Mixing&incorporation of lime,6"deep,complete in place SY 675 $ 2.50 $ 1,687.50 83 Hydrated Lime,complete in place(2716/sy foot 6"deep&36 Ib/sy for 8"deep) Ton 9 $ 180.00 $ 1,620.00 84 Crushed Limestone Base Material-6"thick,complete in place SY 509 $ 12.00 $ 6,108.00 85 HMAC-Type D Pavement 2"thick-includes prime coat,complete in place SY 509 $ 13.00 $ 6,617.00 86 18"-6H:IV Concrete SET,complete in place LS 2 $ 1,500.00 $3,000 87 18"HDPE Pipe,complete in place(Non-Structural) LF 48 $ 35.00 $1,680 Lift-Station Access Road Items Subtotal $23,213 General Items Subtotal $ 67,450.00 Street Construction Concrete Pavement Items Subtotal $ 653,900.60 0 v.; ..««. Storm Sewer Construction Items Subtotal $ 355,288.80 Detention Pond B Construction Items Subtotal $28,040 * *. l� Water Construction Items Subtotal $ 172,729.00 JOSEPH P. SCHULTZ. Sanitary Sewer Construction Items Subtotal $ 128,789.50 k65889 ` Lift-Station Access Road Items Subtotal $23,213 " , e,�►, TOTAL CONSTRUCTION $ 1,429,410.40 / / F-12327 /2-"Z 'II' SC`ULTZ ENGINEERING. LLC. Page 4 of 4