Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Water Report
WATER REPORT FOR Indian Lakes Subdivision Phase XIX & XXI C C I Brazos County, Texas JANUARY 2015 MBESI# 1062-0046 pp McCLURE & BROWNE ENGINEERING/SURVEYING, INC. O� 1008 Woodcreek Dr.,Suite 103 College Station,Tx.77845•(979)693-3838 Engineer Reg.No.F-458 Survey Reg.No. 101033-00 I • I IWATER SYSTEM ANALYSIS for IINDIAN LAKES PHASE XIX & XXI IGeneral Information Anticipated land use: Residential I Anticipated number of lots: 28 lots Notes on surrounding development: This development is located near the existing Phase 16 of Indian Lakes in South Brazos County. Water System Analysis 1 lb Primary water supply line: Existing 12" line on Indian Lakes Drive & 8" line on Mesa Verde Drive Software model: PIPE2000 (Kentucky Pipe Network Model) I Average daily flow: 1.5 gpd per lot Estimated fire demand: 1,000 gpm (at Junction J-31) Pipe material: PVC (C909) IRegulated Items Designed Requirement Notes Min. Pressure( si 28.20 20 mm Fire flow conditions (J-30) Max.Velocity s 11.52 12 max Fire flow conditions (P-29) Conclusion: The proposed water system exceeds the requirements of TCEQ Iand the City of College Station I Applicable Exhibits: Exhibit A Schematic Water System Layout 1��q`ox Exhibit B Static Flow Analysis �r �a`, I Exhibit C Fire Flow Analysis r^''tc '•"'; ..... r a 1**Alp PZ,Zw‘%'., 1/ t �r,. i. Res- .:•:`,,, Itri -o: 9 = 4 'I ii,-. ..'..i.E.:N 7';A ,;,s`....7': " Sy „I>.. 1 / Oa�.,.-f- I I I Indian Lakes,Phase XIX&XXI 111 MBESI#10620046 I I I I I Exhibit B Static Flow Results l 1 1 1 t 1 1 1 Indian Lakes,Phase XIX&XXI 11 MBESI#10620046 II II Exhibit B II Static Flow Results * * * * * * * * * * K Y P I P E 5 * * * * * * * * * * II * * * Pipe Network Modeling Software * * Copyrighted by KYPIPE LLC * * Version 5 - February 2010 * II * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * IIDate & Time: Wed Jan 21 15:49:44 2015 Master File : f:\1062 - clarke & wyndham inc\0046 - Indian lakes phase xix\docs\static.KYP\static.P2K I/ ************************************************ S U MMA R Y OF ORIGINAL DATA I UNITS SPECIFIED FLOWRATE = gallons/minute HEAD (HGL) = feet PRESSURE = psig I PIPELINE DATA ' STATUS CODE: XX -CLOSED PIPE CV -CHECK VALVE P IPE NODE NAMES LENGTH DIAMETER ROUGHNESS MINOR N AME #1 #2 (ft) (in) COEFF. LOSS COEFF. II P-1 VP-2 J-7 7830.00 2199.52 8.00 138.9145 0.00 P-2 J 1 J 7 12.00 138.9145 0.00 P-3 J-2 J-3 3660.00 12.00 138.9145 0.00 P-4 J-3 J-18 1196.76 12.00 140.0000 0.00 II P-5 J-4 J-2 1590.00 8.00 140.0000 0.00 P-6 J-5 J 4 5614.00 6.00 138.9145 0.00 P-7 J-6 J-5 220.00 6.00 138.9145 0.00 P-8 J-3 J-6 3088.00 6.00 138.9145 0.00 P-9 J-7 J-2 4360.48 12.00 138.9145 0.00 P-10 J-7 J 8 3387.00 8.00 138.9145 0.00 P 11 J 8 J 9 621.00 8.00 138.9145 0.00 P-12 J-8 J-10 356.00 6.00 138.9145 0.00 P-13 J-9 J-11 322.00 6.00 138.9145 0.00 P-14 J-3 J-12 635.00 8.00 140.0000 0.00 P 15 J-12 J-13 656.00 8.00 140.0000 0.00 P-16 J-12 J-19 66.16 8.00 140.0000 0.00 P-17 J-13 J-17 565.00 6.00 140.0000 0.00 I P-18 J-13 J-14 807.00 8.00 140.0000 0.00 P-19 J-14 J-15 182.00 4.00 123.9145 0.00 P-20 J-14 J-16 302.00 4.00 123.9145 0.00 P-21 VP-1 J-18 156.66 12.00 140.0000 0.00 P-22 J-18 J-20 120.00 6.00 140.0000 0.00 I I/ P-23 J-20 J-21 400.00 4.00 140.0000 0.00 P 24 J 9 J 22 224.75 8.00 138.9145 0.00 P-25 J-22 J-23 325.00 4.00 138.9145 0.00 P-26 J-22 J-24 676.00 8.00 138.9145 0.00 4.11 P-27 J-24 J-26 244.00 8.00 138.9145 0.00 6 1 IIP-28 J-26 J-28 562.00 8.00 138.9145 0.00 P-29 J-26 J-31 124.12 6.00 138.9145 0.00 P-30 J-28 J-25 342.00 8.00 138.9145 0.00 I/ P-31 J-28 J-29 114.45 6.00 138.9145 0.00 P-32 J-29 J-27 119.78 6.00 138.9145 0.00 P-33 J 31 J 30 102.63 6.00 138.9145 0.00 PUMP/LOSS ELEMENT DATA THERE IS A DEVICE AT NODE VP-1 DESCRIBED BY THE FOLLOWING DATA: (ID= 1) IIHEAD FLOWRATE EFFICIENCY (ft) (gpm) (%) 219.23 0.00 75.00 I 180.00 77.61 1500.00 75.00 3000.00 75.00 THERE IS A DEVICE AT NODE VP-2 DESCRIBED BY THE FOLLOWING DATA: (ID= 2) I/ HEAD FLOWRATE EFFICIENCY (ft) (gpm) (%) 219.23 0.00 75.00 II 180.00 1500.00 75.00 77.61 3000.00 75.00 NODEI/ DATA I NODE NODE EXTERNAL JUNCTION EXTERNAL NAME TITLE DEMAND ELEVATION GRADE (gpm) (ft) (ft) J-1 0.00 287.00 I J-2 0.00 278.00 J 3 0.00 263.00 J-4 0.00 266.00 J-5 15.00 247.00 I/ J-6 0.00 246.00 J-7 0.00 285.00 J-8 0.00 294.00 J-9 0.00 292.00 J-10 6.00 296.00 I J-11 6.00 294.00 J-12 4.50 253.00 J-13 7.50 250.00 J-14 4.50 242.00 J-15 6.00 240.00 J-16 4.50 252.00 J 17 4.50 240.00 J-18 0.00 241.00 J-19 0.00 251.00 I J-20 3.00 247.00 J-21 6.00 240.00 J-22 0.00 295.00 J-23 6.00 291.00 II J-24 0.00 283.00 J-25 0.00 278.00 J 26 0.00 286.00 J-27 6.00 291.00 I J-28 0.00 281.00 J-29 9.00 295.00 J-30 6.00 293.00 J-31 9.00 296.00 VP-1 ---- 239.00 239.00 VP-2 285.00 285.00 II 111 1/ II OUTPUTli OPTION DATA OUTPUT SELECTION: ALL RESULTS ARE INCLUDED IN THE TABULATED OUTPUT MAXIMUM AND MINIMUM PRESSURES = 5 II MAXIMUM AND MINIMUM VELOCITIES 5 MAXIMUM AND MINIMUM HEAD LOSS/1000 = SYSTEMII CONFIGURATION NUMBER OF PIPES (p) = 33 NUMBER OF END NODES (j) = 31 I NUMBER OF PRIMARY LOOPS (1) = 1 NUMBER OF SUPPLY NODES (f) = 2 NUMBER OF SUPPLY ZONES (z) = 1 1 Case: 0 111 RESULTS OBTAINED AFTER 20 TRIALS: ACCURACY = 0.00006 SIMULATION DESCRIPTION (LABEL) i I PIPELINE RESULTS STATUS CODE: XX -CLOSED PIPE CV -CHECK VALVE PIPE NODE NUMBERS FLOWRATE HEAD MINOR LINE HL+ML/ HL/ IN A M E #1 #2 LOSS LOSS VELO. 1000 1000 (gpm) (ft) (ft) (ft/s) (ft/ft) (ft/ft) P-1 VP-2 J-1 103.50 1.90 0.00 0.66 0.24 0.24 P-2 J-1 J-7 103.50 0.07 0.00 0.29 0.03 0.03 9-3 J-2 J-3 47.51 0.03 0.00 0.13 0.01 0.01 P-4 J 3 J-18 9.00 0.00 0.00 0.03 0.00 0.00 P-5 J-4 J-2 -7.99 0.00 0.00 0.05 0.00 0.00 P-6 J-5 J-4 -7.99 0.05 0.00 0.09 0.01 0.01 I P-7 J-6 J-5 7.01 0.00 0.00 0.08 0.01 0.01 P 8 J-3 J 6 7.01 0.02 0.00 0.08 0.01 0.01 P-9 J-7 J-2 55.50 0.05 0.00 0.16 0.01 0.01 P-10 J-7 J-8 48.00 0.20 0.00 0.31 0.06 0.06 I P-11 J-8 J-9 42.00 0.03 0.00 0.27 0.05 0.05 P-12 J-8 J-10 6.00 0.00 0.00 0.07 0.01 0.01 P 13 J 9 J 11 6.00 0.00 0.00 0.07 0.01 0.01 P-14 J-3 J-12 31.50 0.02 0.00 0.20 0.03 0.03 I P-15 J-12 J-13 27.00 0.01 0.00 0.17 0.02 0.02 P-16 J-12 J-19 0.00 0.00 0.00 0.00 0.00 0.00 P 17 J 13 J 17 4.50 0.00 0.00 0.05 0.00 0.00 P-18 J-13 J-14 15.00 0.01 0.00 0.10 0.01 0.01 P-19 J-14 J-15 6.00 0.01 0.00 0.15 0.04 0.04 1 P-20 J-14 J-16 4.50 0.01 0.00 0.11 0.03 0.03 P-21 VP-1 J-18 0.00 0.00 0.00 0.00 0.00 0.00 P-22 J 18 J 20 9.00 0.00 0.00 0.10 0.01 0.01 P-23 J-20 J-21 6.00 0.01 0.00 0.15 0.04 0.04 I P-24 J-9 J-22 36.00 0.01 0.00 0.23 0.03 0.03 P-25 J-22 J-23 6.00 0.01 0.00 0.15 0.04 0.04 P 26 J 22 J 24 30.00 0.02 0.00 0.19 0.02 0.02 P-27 J-24 J-26 30.00 0.01 0.00 0.19 0.02 0.02 P-28 J-26 J-28 15.00 0.00 0.00 0.10 0.01 0.01 IIP-29 J-26 J-31 15.00 0.00 0.00 0.17 0.03 0.03 II C filt ill P-30 J-28 J-25 0.00 0.00 0.00 0.00 0.00 0.00 P-31 J-28 J-29 15.00 0.00 0.00 0.17 0.03 0.03 P-32 J-29 J-27 6.00 0.00 0.00 0.07 0.01 0.01 r P-33 J-31 J-30 6.00 0.00 0.00 0.07 0.01 0.01 PUMP/LOSSill ELEMENT RESULTS 1: INLET OUTLET PUMP EFFIC- USEFUL INCREMTL TOTAL #PUMPS #PUMPS NPSH [: NAME FLOWRATE HEAD HEAD HEAD ENCY POWER COST COST PARALLEL SERIES Avail. (gpm) (ft) (ft) (ft) (%) (Hp) ($) ($) r, (ft) 4* Device "VP-1" is closed VP-1 0.00 0.00 262.91 0.0 75.00 0. 0.0 0.0 ** ** r 33.2 io VP-2 103.50 0.00 218.95 219.0 75.00 0. 0.0 0.0 ** ** 33.2 NODE:: RESULTS NODE NODE EXTERNAL HYDRAULIC NODE PRESSURE NODE r NAME TITLE DEMAND GRADE ELEVATION HEAD PRESSURE Ili (gpm) (ft) (ft) (ft) (psi) J-1 0.00 502.06 287.00 215.06 93.19 OIs J-2 0.00 501.94 278.00 223.94 97.04 J-3 0.00 501.91 263.00 238.91 103.53 SIN J-4 0.00 501.93 266.00 235.93 102.24 J-5 15.00 501.89 247.00 254.89 110.45 J-6 0.00 501.89 246.00 255.89 110.88 41.4 J-7 0.00 501.98 285.00 216.98 94.03 ill J-8 0.00 501.79 294.00 207.79 90.04 J-9 0.00 501.76 292.00 209.76 90.90 J-10 6.00 501.78 296.00 205.78 89.17 0" J-11 6.00 501.76 294.00 207.76 90.03 J-12 4.50 501.89 253.00 248.89 107.85 ill J-13 7.50 501.88 250.00 251.88 109.15 J-14 4.50 501.87 242.00 259.87 112.61 J-15 6.00 501.87 240.00 261.87 113.47 II J-16 4.50 501.87 252.00 249.87 108.27 J-17 4.50 501.88 240.00 261.88 113.48 J-18 0.00 501.91 241.00 260.91 113.06 J-19 0.00 501.89 251.00 250.89 108.72 J-20 3.00 501.91 247.00 254.91 110.46 J-21 6.00 501.89 240.00 261.89 113.49 J 22 0.00 501.75 295.00 206.75 89.59 J-23 6.00 501.74 291.00 210.74 91.32 I/ J-24 J-25 0.00 501.73 283.00 218.73 94.78 0.00 501.72 278.00 223.72 96.95 J-26 0.00 501.73 286.00 215.73 93.48 3-27 6.00 501.72 291.00 210.72 91.31 J-28 0.00 501.72 281.00 220.72 95.65 II J-29 9.00 501.72 295.00 206.72 89.58 J-30 6.00 501.72 293.00 208.72 90.45 J 31 9.00 501.72 296.00 205.72 89.15 VP-1 ---- 501.91 239.00 262.91 113.93 IIVP-2 ---- 503.95 285.00 218.95 94.88 MAXIMUM AND MINIMUM VALUES / li Ii PRESSURESI: I: 1 JUNCTION NUMBER MAXIMUM JUNCTION NUMBER MINIMUM PRESSURES PRESSURES (psi) (psi) I VP-1 113.93 J-31 89.15 J-21 113.49 J-10 89.17 J-17 113.48 J-29 89.58 J-15 113.47 J-22 89.59 J-18 113.06 J-11 90.03 I VELOCITIES PIPE MAXIMUM PIPE MINIMUM I NUMBER VELOCITY (ft/s) NUMBER VELOCITY (ft/s) P-1 0.66 P-4 0.03 P-10 0.31 P-5 0.05 1 P-2 P-11 0.29 P-17 0.05 0.27 P 12 0.07 P-24 0.23 P-13 0.07 I H L + M L / 1 0 0 0 PIPE MAXIMUM PIPE MINIMUM NUMBER HL+ML/1000 NUMBER HL+ML/1000 (ft/ft) (ft/ft) IP-1 0.24 P-4 0.00 P-10 0.06 P-5 0.00 P-11 0.05 P-17 0.00 I P-19 0.04 P-33 0.01 P-25 0.04 P-12 0.01 H L / 1 0 0 0 I PIPE MAXIMUM PIPE MINIMUM NUMBER HL/1000 NUMBER HL/1000 (ft/ft) (ft/ft) I P-1 0.24 P-4 0.00 P-10 0.06 P-5 0.00 P-11 0.05 P-17 0.00 P-19 0.04 P-33 0.01 IIP-25 0.04 P-12 0.01 SUMMARY OF INFLOWS AND OUTFLOWS I/ (+) INFLOWS INTO THE SYSTEM FROM SUPPLY NODES (-) OUTFLOWS FROM THE SYSTEM INTO SUPPLY NODES I/ NODE FLOWRATE NODE NAME (gpm) TITLE VP-2 103.50 I/ NET SYSTEM INFLOW 103.50 NET SYSTEM OUTFLOW = 0.00 NET SYSTEM DEMAND 103.50 I I ***** HYDRAULIC ANALYSIS COMPLETED ***** I I! I I I I I I I I Exhibit C iFire Flow Results I I I I I I I I I Indian Lakes,Phase XIX&XXI IMBESI#10620046 r L A' iim Exhibit C 0114 Fire Flow Results imi * * * * * * * * * * K Y P I P E 5 * * * * * * * * * * * * fria * Pipe Network Modeling Software * ill * * * Copyrighted by KYPIPE LLC * * Version 5 - February 2010 * PP * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * lir !ft Date & Time: Wed Jan 21 16:07:01 2015 iiir Master File : f:\1062 - clarke & wyndham inc\0046 - Indian lakes phase xix\docs\fire.KYP\fire.P2K rim ************************************************ bot SUMMARY OF ORIGINAL DATA ************************************************ UNITSII SPECIFIED I/ FLOWRATE = gallons/minute HEAD (HGL) = feet PRESSURE = psig PIPELINE DATA STATUS CODE: XX -CLOSED PIPE CV -CHECK VALVE PIPEI I/ NODE NAMES LENGTH DIAMETER ROUGHNESS MINOR NAME #1 #2 (ft) (in) COEFF. LOSS COEFF. '" P-1 VP-2 J-1 7830.00 8.00 138.9145 0.00 1liP-2 J-1 J-7 2199.52 12.00 138.9145 0.00 P-3 J-2 J-3 3660.00 12.00 138.9145 0.00 P-4 J-3 J-18 1196.76 12.00 140.0000 0.00 P-5 J-4 J-2 1590.00 8.00 140.0000 0.00 1 1! P-6 J-5 J-4 5614.00 6.00 138.9145 0.00 P-7 J-6 J-5 220.00 6.00 138.9145 0.00 P-8 J-3 J-6 3088.00 6.00 138.9145 0.00 P-9 J-7 J-2 4360.48 12.00 138.9145 0.00 II P-10 J-7 J-8 3387.00 8.00 138.9145 0.00 P-11 J-8 J-9 621.00 8.00 138.9145 0.00 P 12 J 8 J 10 356.00 6.00 138.9145 0.00 P-13 J-9 J-11 322.00 6.00 138.9145 0.00 1/ P-14 J-3 J-12 635.00 8.00 140.0000 0.00 P-15 J-12 J-13 656.00 8.00 140.0000 0.00 P 16 J 12 J 19 66.16 8.00 140.0000 0.00 P-17 J-13 J-17 565.00 6.00 140.0000 0.00 P-18 J-13 J-14 807.00 8.00 140.0000 0.00 1 II P-19 J-14 J-15 182.00 4.00 123.9145 0.00 P-20 J-14 J-16 302.00 4.00 123.9145 0.00 P-21 VP-1 J-18 156.66 12.00 140.0000 0.00 P-22 J-18 J-20 120.00 6.00 140.0000 0.00 I/ P-23 J-20 J-21 400.00 4.00 140.0000 0.00 P-24 J-9 J-22 224.75 8.00 138.9145 0.00 P-25 J-22 J-23 325.00 4.00 138.9145 0.00 P-26 J-22 J-24 676.00 8.00 138.9145 0.00 P-27 J-24 J-26 244.00 8.00 138.9145 0.00 IIP-28 J-26 J-28 562.00 8.00 138.9145 0.00 I 11 I IP-29 J-26 J-31 124.12 6.00 138.9145 0.00 9-30 J-28 J-25 342.00 8.00 138.9145 0.00 P-31 J-28 J-29 114.96 6.00 138.9145 0.00 P-32 J-29 J-27 119.29 6.00 138.9145 0.00 P-33 J-31 J-30 102.63 6.00 138.9145 0.00 1 I PUMP/LOSS ELEMENT DATA THERE IS A DEVICE AT NODE VP-1 DESCRIBED BY THE FOLLOWING DATA: (ID= 1) HEAD FLOWRATE EFFICIENCY (ft) (gpm) (%) 219.23 0.00 75.00 180.00 1500.00 75.00 I77.61 3000.00 75.00 THERE IS A DEVICE AT NODE VP-2 DESCRIBED BY THE FOLLOWING DATA: (ID= 2) I HEAD FLOWRATE (gpm) EFFICIENCY (ft) (a) 219.23 0.00 75.00 180.00 1500.00 75.00 II 77.61 3000.00 75.00 NODEII DATA NODE NODE EXTERNAL JUNCTION EXTERNAL I NAME TITLE DEMAND (gpm) ELEVATION GRADE (ft) (ft) J-1 0.00 287.00 J-2 0.00 278.00 II J-3 0.00 263.00 J-4 0.00 266.00 J-5 15.00 247.00 J-6 0.00 246.00 I/ J-7 0.00 285.00 J-8 0.00 294.00 J-9 0.00 292.00 J-10 6.00 296.00 J-11 6.00 294.00 J-12 4.50 253.00 J-13 7.50 250.00 J-14 4.50 242.00 J-15 6.00 240.00 II J-16 J-17 4.50 252.00 4.50 240.00 J-18 0.00 241.00 J-19 0.00 251.00 J-20 3.00 247.00 li J-21 6.00 240.00 J-22 0.00 295.00 J-23 6.00 291.00 J-24 0.00 283.00 I J-25 0.00 278.00 J-26 0.00 286.00 J-27 6.00 291.00 J-28 0.00 281.00 I J-29 9.00 295.00 J 30 6.00 293.00 J-31 1009.00 296.00 VP-1 ---- 239.00 239.00 VP-2 ---- 285.00 285.00 I I ir O UTPUT OPTION DATA II OUTPUT SELECTION: ALL RESULTS ARE INCLUDED IN THE TABULATED OUTPUT MAXIMUM AND MINIMUM PRESSURES = 5 MAXIMUM AND MINIMUM VELOCITIES = 5 IIMAXIMUM AND MINIMUM HEAD LOSS/1000 = 5 S YSTEM CONFIGURATION IINUMBER OF PIPES (p) = 33 NUMBER OF END NODES (j) = 31 NUMBER OF PRIMARY LOOPS (1) = 1 ii NUMBER OF SUPPLY NODES (f) = 2 NUMBER OF SUPPLY ZONES (z) = 1 IICase: 0 RESULTS OBTAINED AFTER 6 TRIALS: ACCURACY = 0.00001 S IMULATIONII DESCRIPTION (LABEL) II P IPELINE RESULTS IISTATUS CODE: XX -CLOSED PIPE CV -CHECK VALVE P IPE NODE NUMBERS FLOWRATE HEAD MINOR LINE HL+ML/ HL/ N AME #1 #2 LOSS LOSS VELO. 1000 1000 II (gpm) (ft) (ft) (ft/s) (ft/ft) (ft/ft) P-1 VP-2 J-1 588.90 47.45 0.00 3.76 6.06 6.06 2-2 J-1 J-7 588.90 1.85 0.00 1.67 0.84 0.84 II 2-3 J-2 J-3 -423.61 1.67 0.00 1.20 0.46 0.46 P-4 J-3 J-18 -505.60 0.75 0.00 1.43 0.63 0.63 P-5 J-4 J-2 35.49 0.05 0.00 0.23 0.03 0.03 P-6 J-5 J-4 35.49 0.76 0.00 0.40 0.14 0.14 P-7 J-6 J-5 50.49 0.06 0.00 0.57 0.26 0.26 II P-8 J-3 J-6 50.49 0.80 0.00 0.57 0.26 0.26 2-9 J-7 J-2 -459.10 2.31 0.00 1.30 0.53 0.53 P-10 J-7 J-8 1048.00 59.69 0.00 6.69 17.62 17.62 P-11 J-8 J-9 1042.00 10.83 0.00 6.65 17.44 17.44 II P-12 J-8 J-10 6.00 0.00 0.00 0.07 0.01 0.01 P-13 J-9 J-11 6.00 0.00 0.00 0.07 0.01 0.01 P-14 J-3 J-12 31.50 0.02 0.00 0.20 0.03 0.03 P-15 J-12 J-13 27.00 0.01 0.00 0.17 0.02 0.02 2-16 J-12 J-19 0.00 0.00 0.00 0.00 0.00 0.00 II 2-17 J-13 J-17 4.50 0.00 0.00 0.05 0.00 0.00 2-18 J-13 J-14 15.00 0.01 0.00 0.10 0.01 0.01 2-19 J-14 J-15 6.00 0.01 0.00 0.15 0.04 0.04 P-20 J-14 J-16 4.50 0.01 0.00 0.11 0.03 0.03 1 P-21 VP-1 J-18 514.60 0.10 0.00 1.46 0.65 0.65 P-22 J-18 J-20 9.00 0.00 0.00 0.10 0.01 0.01 P-23 J-20 J-21 6.00 0.01 0.00 0.15 0.04 0.04 P-24 J-9 J-22 1036.00 3.88 0.00 6.61 17.25 17.25 II P-25 J-22 J-23 6.00 0.01 0.00 0.15 0.04 0.04 2-26 J-22 J-24 1030.00 11.54 0.00 6.57 17.07 17.07 P-27 J-24 J-26 1030.00 4.16 0.00 6.57 17.07 17.07 P-28 J-26 J-28 15.00 0.00 0.00 0.10 0.01 0.01 P-29 J-26 J-31 1015.00 8.37 0.00 11.52 67.42 67.42 IIP-30 J-28 J-25 0.00 0.00 0.00 0.00 0.00 0.00 II IP-31 J-28 J-29 15.00 0.00 0.00 0.17 0.03 0.03 P-32 J-29 J-27 6.00 0.00 0.00 0.07 0.01 0.01 P-33 J-31 J-30 6.00 0.00 0.00 0.07 0.01 0.01 PUMP/LOSSi li ELEMENT RESULTS I I! INLET OUTLET PUMP EFFIC- USEFUL INCREMTL TOTAL #PUMPS #PUMPS NPSH I NAME FLOWRATE HEAD HEAD HEAD ENCY POWER COST COST PARALLEL SERIES Avail. (gpm) (ft) (ft) (ft) (%) (Hp) ($) ($) (ft) IIVP-1 514.60 0.00 213.82 213.8 75.00 0. 0.0 0.0 ** ** 33.2 VP-2 588.90 0.00 212.29 212.3 75.00 0. 0.0 0.0 ** ** II 33.2 I NODE RESULTS NODE NODE EXTERNAL HYDRAULIC NODE PRESSURE NODE NAME TITLE DEMAND GRADE ELEVATION HEAD PRESSURE (gpm) (ft) (ft) (ft) (psi) I/ J-1 0.00 449.84 287.00 162.84 70.56 J-2 0.00 450.30 278.00 172.30 74.66 J-3 0.00 451.97 263.00 188.97 81.89 I J-4 0.00 450.35 266.00 184.35 79.89 J-5 15.00 451.11 247.00 204.11 88.45 J-6 0.00 451.17 246.00 205.17 88.91 J-7 0.00 447.99 285.00 162.99 70.63 J-8 0.00 388.30 294.00 94.30 40.86 II J-9 0.00 377.47 292.00 85.47 37.04 J-10 6.00 388.30 296.00 92.30 40.00 J-11 6.00 377.47 294.00 83.47 36.17 J-12 4.50 451.96 253.00 198.96 86.21 I J-13 7.50 451.94 250.00 201.94 87.51 J-14 4.50 451.94 242.00 209.94 90.97 J-15 6.00 451.93 240.00 211.93 91.84 J-16 4.50 451.93 252.00 199.93 86.64 J-17 4.50 451.94 240.00 211.94 91.84 II J-18 0.00 452.72 241.00 211.72 91.75 J-19 0.00 451.96 251.00 200.96 87.08 J-20 3.00 452.72 247.00 205.72 89.14 J-21 6.00 452.70 240.00 212.70 92.17 11 J-22 0.00 373.60 295.00 78.60 34.06 J-23 6.00 373.58 291.00 82.58 35.79 J-24 0.00 362.06 283.00 79.06 34.26 J-25 0.00 357.89 278.00 79.89 34.62 J-26 0.00 357.90 286.00 71.90 31.15 I/ J-27 6.00 357.89 291.00 66.89 28.98 J-28 0.00 357.89 281.00 76.89 33.32 J-29 9.00 357.89 295.00 62.89 27.25 J-30 6.00 349.53 293.00 56.53 24.50 I J-31 1009.00 349.53 296.00 53.53 23.20 VP-1 452.82 239.00 213.82 92.66 VP-2 497.29 285.00 212.29 91.99 IIMAXIMUM AND MINIMUM VALUES PRESSURESII gym„ Pm 40 10 40 JUNCTION MAXIMUM JUNCTION MINIMUM NUMBER PRESSURES NUMBER PRESSURES rim (psi) (psi) VP-1 92.66 J-31 23.20 J-21 92.17 J-30 24.50 4/114 VP-2 91.99 J-29 27.25 J-17 91.84 J-27 28.98 J-15 91.84 J-26 31.15 VELOCITIES Pft PIPE MAXIMUM PIPE MINIMUM kw NUMBER VELOCITY NUMBER VELOCITY (ft/s) (ft/s) P. P-29 11.52 P-17 0.05 fM P-10 6.69 P-12 0.07 P-11 6.65 P-13 0.07 P-24 6.61 P-32 0.07 !!ft P-26 6.57 P-33 0.07 kr H L + M L / 1 0 0 0 Pm PIPE MAXIMUM PIPE MINIMUM NUMBER HL+ML/1000 NUMBER HL+ML/1000 (ft/ft) (ft/ft) P-29 67.42 P-17 0.00 I/ P-10 17.62 P-33 0.01 P-11 17.44 P-12 0.01 P-24 17.25 P-13 0.01 P-26 17.07 P-32 0.01 IIH L / 1 0 0 0 PIPE MAXIMUM PIPE MINIMUM NUMBER HL/1000 NUMBER HL/1000 I/ (ft/ft) (ft/ft) P-29 67.42 P-17 0.00 P-10 17.62 P-33 0.01 II P-il 17.44 P-12 0.01 P-24 17.25 P-13 0.01 P-26 17.07 P-32 0.01 IISUMMARY OF INFLOWS AND OUTFLOWS (+) INFLOWS INTO THE SYSTEM FROM SUPPLY NODES II (-) OUTFLOWS FROM THE SYSTEM INTO SUPPLY NODES NODE FLOWRATE NODE NAME (gpm) TITLE VP-1 514.60 VP-2 588.90 NET SYSTEM INFLOW = 1103.50 II NET SYSTEM OUTFLOW = 0.00 NET SYSTEM DEMAND = 1103.50 ***** HYDRAULIC ANALYSIS COMPLETED ***** OP Mir 1 11 II i