Loading...
HomeMy WebLinkAboutDrainage Info MITCHELL M MORGAN City of College Station 22 Jan 2015 City Engineer/Development Services P.O.Box 9960 College Station,Texas 77842 Attn: Alan Gibbs,P.E. RE: Drainage Design A&M Consolidated High School Gym Expansion Dear Alan, The following drainage information is being provided for the building expansion(primarily gym expansion)of A&M Consolidated High School at 1801 Harvey Mitchell Parkway South in College Station. Background The site is currently developed as a high school with parking lots, sports facilities,and one single structure which houses the cafeteria, gym,auditorium,and classrooms. Smaller portable buildings have been located onsite and have been recently removed in anticipation of this building expansion project. Drainage from the existing site drains primarily in 3 major directions as seen on Exhibit 1. In the area of this expansion project the drainage discharges primarily in one direction to Detention Pond#2 which then discharges in a channel between Madera and Guadalupe streets. In addition,there is an existing storm sewer in the area of the expansion that picks up flow from roof drains on the building and discharges that flow across Welsh Avenue. Proposed Site Improvements Six portable buildings and a covered walkway will be removed to create room for the proposed renovations. The renovations consist of additional bathrooms, a dance gym, concessions stand/ticket office, lobby,corridor into the gymnasium,and a new entranceway. The attached Exhibit 2 illustrates the current and proposed impervious conditions for the site.Exhibit 3 is a Google Earth image showing these portable buildings that have recently been removed. In addition to the building expansion,there will be utility relocations associated with the project. There is an electrical line that will be relocated around the proposed building. The electrical line will require an associated public utility easement as it is a public electrical line. Flowlines and slopes were checked on the sanitary sewer line. It cannot be relocated from under the building because the line cannot meet minimum service line grades per building code. Therefore,the private sanitary sewer line will be left in place and reconstructed with required materials and embedment to meet building code requirements. Removal of the six portable buildings and covered sidewalk will result in a decrease of 7,555 square feet of impervious cover. The proposed renovations will result in a 7,219 square feet increase in impervious cover. Overall the site will see a decrease in impervious cover of 336 square feet. 3204 EARL RUDDER FREEWAY SOUTH•COLLEGE STATION TX 77845• 979 260 6963 979 260 3564 FIRM#1443 CIVIL ENGINEERING HYDRAULICS HYDROLOGY UTILITIES STREETS SITE PLANS SUBDIVISIONS info@mitchellandmorgan.com •www.mitchellandmorgan.com