Loading...
HomeMy WebLinkAboutStaff Commentstt ! CITY OF COLT IGI STATION Horne of Texas A&M University" MEMORANDUM October 4, 2013 TO: Travis Nance; via; travis.nance@oldhamgoodwin.com FROM: Molly Hitchcock, AICP, Assistant Director SUBJECT: ST. JOSEPH CLINIC (Site Plan, Development Permit, & NRA) Thank you for the submittal of your Site Plan, Development Permit, and Non -Residential Architectural Standards applications. This project will be distributed to staff next week for their review. PC: Hunter Goodwin, OGC Medical I, LLC; via: hunter.goodwin(a.oldhamgoodwin.com Melissa Thomas, Gessner Engineering; via: mthomas _.gessnerenaineering com Robert Payne; via: rpayne@rlpayne.com P&DS Project No. 13-00900202 P&DS Project No. 13-00900203 STAFF REVIEW COMMENTS NO. 1 St. Joseph Clinic — NRA Review 13-00900203 PLANNING 1. In Suburban Commercial, flat roofs are prohibited. All roofs must resemble residential roof types with a maximum of 8:12 and minimum 4:12 roof slope. Please reference UDO 7.10.13.4. 2. Per UDO 7.2.H.2.e., in Suburban Commercial the maximum height of buildings is 24' to the eave and 35' to the peak of the roof at the highest point. When the eave height exceeds 15' it must resemble a two-story facade. When the building is located within 50' of single-family development, the eave height cannot exceed 12' and limited to one-story. 3. Pilasters, wall plane recessions, and decorative stormwater management design features cannot be used to meet the architectural relief requirement in Suburban Commercial. 4. Architectural relief elements in Suburban Commercial differ from those in other non-residential zoning districts. The window canopies are considered a design element. At least 2 different design elements are required every 45 -foot section of all facades, including section less than 45' facing the ROW. Please reference UDO 7.10.B.3 for the list of architectural relief elements. 5. Please provide a sample of the Facebrick material. 6. Please add contact information for the owner/developer and applicant on the title block. Reviewed by: Jenifer Paz Date: October 14, 2013 Y y. CITY Oh COLLFIGI STATION Home of Texas A&M University' MEMORANDUM October 15, 2013 TO: Travis Nance, via e-mail; travis.nance@oldhamgoodwin.com FROM: Jenifer Paz, Staff Planner SUBJECT: ST. JOSEPH CLINIC (NRA) Staff reviewed the above-mentioned Non -Residential Architectural plans as requested. The following page is a list of staff review comments detailing items that need to be addressed. Please address the comments and submit the following information by any Monday at 10:00 a.m. for further staff review: One (1) revised set of elevation drawings Material Sample Please note that this application will expire in applicant has not provided written response Administrator that seek to address the staff re, comments that you are not addressing with t explaining the details. If you have any questions at 979.764.3570. Attachments: Staff review comments 90 days from the date of this memo, if the comments and revised documents to the iew comments contained herein. If there are ie revised elevations, please attach a letter or need additional information, please call me PC: OGC Medical I, LLC, via e-mail; hunter.goodwin@oldham,,goodwin.com Melissa Thomas, Lessner Engineering, via e-mail; mt as@gessnerengineering.com Robert Payne, via e-mail; rpayne@rlpayne.com P&DS Project No. 13-00900203 Planning u° Development Sea -vices PAA ROX 9960 • I101 TFXAS VVFMT1 • C(_)LLF.(ri? STATION • 7T XAS • ?7842 FI_. 979?61 _3: ?0 • FAX 971),-04.3496 cstx.gov/devservices STAFF REVIEW COMMENTS NO. 1 St. Joseph Clinic — NRA Review 13-00900203 PLANNING 1. The UDO defines a entry portico as "covered ambulatory consisting of a series of columns placed at regular intervals supporting a roof, normally attached as a colonnaded; porch to a building." The east and north proposed entry porticos do not meet this definition. Please provide an architectural relief element for these sections. 2. On the north elevation, please revise length of the remaining portion. It appears to be 39'6". 3. Wall plane recessions are not considered an architectural relief in Suburban Commercial. Revise the north and south elevation. A window canopy or eave over 18" may counts as the second architectural relief element. 4. Please provide a detail of the decorative fapade lighting. Reviewed by: Jenifer Paz Date: October 31, 2013 CITY OF COLLI GI; STATION Home of Texas AeaM University' MEMORANDUM November 4, 2013 TO: Travis Nance, via e-mail; travis.nanceCcD-oldhamgoodwin.com FROM: Jenifer Paz, Staff Planner SUBJECT: ST. JOSEPH CLINIC (NRA) Staff reviewed the above-mentioned Non -Residential Architectural plans as requested. The following page is a list of staff review comments detailing items that need to be addressed. Please address the comments and submit the following information by any Monday at 10:00 a.m. for further staff review: One (1) revised set of elevation drawings Please note that this application will expire in 90 days from the date of this memo, if the applicant has not provided written response comments and revised documents to the Administrator that seek to address the staff review comments contained herein. If there are comments that you are not addressing with the revised elevations, please attach a letter explaining the details. If you have any questions or need additional information, please call me at 979.764.3570. Attachments: Staff review comments PC: OGC Medical I, LLC, via e-mail; hunter.goodwin(a oldhamgoodwin.com Melissa Thomas, Gessner Engineering, via e-mail; mt mas essnere ineerin .com Robert Payne, via e-mail; rpa ne ,rlpayne.com P&DS Project No. 13-00900203 1'lmaning & Development Ser -vices P-0, E. OX 9960 • 1 E 01 "I L XAS AVENUE UE • COLLEGES EATION • TEXAS .77842 TEL_. 979.764.3 7t) • L'AX. 979.764.3490