Loading...
HomeMy WebLinkAboutWater Report (2) WATER REPORT FOR HIDDEN SPRINGS SUBDIVISION, PHASE I COLLEGE STATION, TEXAS FEBRUARY 2007 MBESI# 1056-0005 SUBMITTED BY: N McCLURE & BROWNE ENGINEERING/SURVEYING, INC. 111111111008 Woodcreek Drive,Suite 103 •College Station,Texas 77845 (979)693-3838•Fax:(979)693-2554•Email: McClureBrowne@Verizon.net C1'1o1 ,� . WATER SYSTEM ANALYSIS for HIDDEN SPRINGS, PHASE 1 General Information Area encompassed by this phase: 76.735 acres Anticipated land use: Single family residential Anticipated number of lots: 30 lots Notes on surrounding development: Hidden Springs is located on FM 2154 approximately 3500' south of the Greens Prairie Trail intersection. Water System Analysis Primary water supply line: Existing 8" line on FM 2154 Software model: PIPE2000 (Kentucky Pipe Network Model) Average daily flow: 267 gpd (0.185 gpm) per residential lot Peaking factor: 4.0 Estimated peak domestic demand: 1.5 gpm per residential lot Estimated fire demand: 1000 gpm Pipe material: PVC (C909) Most Hydraulically Remote Point: Node J-8 (See Exhibit A) This is determined by calculating the lowest pressure under static conditions. Regulated Items Designed Requirement Notes Min. Pressure(psi) 58.09 20 (min) Fire flow conditions (J-8) Max.Velocity(fps) 6.55 12 (max) Fire flow conditions (P-1 &P-7) Conclusion: The proposed water system exceeds the requirements of TCEQ and the City of College Station Applicable Exhibits: Exhibit A Schematic Water System Layout +`��.�..e��r� Exhibit B Fire Flow Information provided by Wellborn SUD .—�P�E. F TF-11iit Exhibit C Static Flow Model Output for Hidden Springs, Phase:-' moi► •••• *�ig Exhibit D Fire Flow Model Output for Hidden Springs, Phase .JEFFERY...ROBERTSON .................. ��9 94745........., Il 116.0.'••• • CENS�0•••-* tONAL .?= HIDDEN SPRINGS,PHASE 1 MBESI#10560005 ~ ' / ` `` / \ \ r~ '' / \ k — '_ -- __ `` /~ / ` .^ � / ` - -��� ��-____ ___ | \ ' ~^ 6g - ----' - - ---- - - ---- - - — _ ___1 _ _ ___ _ _ � ` V - - ` C. c\.Q' r� V----- ' _` )) / � �i �|| � '� � � � -` ,~ ji > ~ — -- � �J _ `^ [/i^ �*� , -�`�-�� -- ^�- - -- -- `` ' (j '� - ` \ IN � 6q \ -- `- � J i� _~ �� � • \ { ~—~ r� o ` \ -_ � ~~ ~� ii w _/ —~ �� � \ ° \ -_ __ ~' ' -� � �� m � -- �� 1 �~� ~ i/ ` EJ | / / | | | / / `` | [ \. _ ' �- | -- -- -- -- � | `` ! '^ / \` *6 -r| / � i / / �� ' . ` / *w -- -� | | � I `~ ,--- . ' ^- ~- ~^ ' / \ / \- -- ' 1 ' ` �� / y L / I11I , 04„,.. 0, ~~ L w • 4 ii Icy / y ,, ••,, | • / / ,//, iy // 1 r ...„.,--...... ..._, \\:..., ....,.... \ q., / ,..-- I i rf-2 co I No -----'a \ (21 1 i • -- \--I__ ,..)'' \ I-- i .,,,, ,!1__,9,.--:_ci i:1_4 ___ __________ 77:32„.#___:.__--.__iii_z_"--...-:--:-7—__. ______:.:_,, .__ ___ __ ._____ -- .- ____ ._....:..._.. "...:_i. / ....„._..._-_ ___ _ __ ---, ` �__' _-__ . / ---- T / / ......._. - :_ -____ - / .' ...............:__7. ..... .r_ _ ___I / � : /,- / ' / / / / . /\ / / / / // / / / / \ / '' / / / / \ / ' / / I / / / / / / \ / / / / / ` / / ( / / / / / / __ . / / / / /' / ~/ c / I / -_ / / ( . \ / / ' \` ' / / / ' / ``` `.� / / / / /' / ' ` / / � � - � (- -- 7 / // '/ / / '� . / / / / / � ` . �� / / . / / r-- - - �� - - _ • ~ Exhibit B FIRE FLOW TEST PERFORMED BY WELLBORN S. UD. FLOW TEST RESULTS NOZZLE SIZE: 2.5" LOCATION: On Wellborn Road approx. 800 feet south of Hidden Springs Subdivision (GPM): 1150 Static PSI: 82 psi Residual PSI: 70 psi Exhibit B FIRE FLOW TEST DATA Hidden Springs Subdivision,Phase 1 Exhibit C (Static Flow Model) + + KYPIPE + + + + + + + + + ` + University of Kentucky Network Modeling Software ` + Copyrighted by KYPIPE LLC y * Version 3 - 11/01/2005 + + Date & Time: Fri Feb 09 11:31:00 2007 INPUT DATA FILENAME F:\1056-J-1\10560005.DT2 TABULATED OUTPUT FILENAME F:\1056-J-1\10560005.0T2 POSTPROCESSOR RESULTS FILENAME F:\1056-J-1\10560005.RS2 ++++++++++++++++++++++++++++++++++++++++++++++++ SUMMARY OF ORIGINAL DATA U N ITS SPECIFIED FLOWRATE = gallons/minute HEAD (HGL) = feet PRESSURE = psig PIPELINE DATA STATUS CODE: XX -CLOSED PIPE CV -CHECK VALVE P IPE NODE NAMES LENGTH DIAMETER ROUGHNESS MINOR N AME #1 #2 (ft) (in) COEFF. LOSS COEFF. P-1 VP-1 3-7 574.59 8.00 130.0000 0.00 P-2 3-3 3-2 536.34 3.00 130.0000 0.00 P-3 3-3 3-6 877.67 6.00 130.0000 0.00 P-4 J-4 3-8 805.72 8.00 130.0000 0.00 P-5 3-6 3-5 351.06 3.00 130.0000 0.00 P-6 3-4 3-6 967.30 8.00 130.0000 0.00 P-7 3-7 3-4 149.02 8.00 130.0000 0.00 P-8 3-8 3-3 880.72 6.00 130.0000 0.00 END NODE DATA NODE NODE EXTERNAL JUNCTION EXTERNAL NAME TITLE DEMAND ELEVATION GRADE (gpm) (ft) (ft) J-2 3.00 277.00 J-3 6.38 284.00 J-4 4.12 276.00 J-5 2.62 276.00 J-6 6.00 282.00 J-7 0.00 277.00 J-8 4.12 288.00 VP-1 ---- 275.00 275.00 MAXIMUM AND MINIMUM PRESSURES = 4 MAXIMUM AND MINIMUM VELOCITIES = 4 MAXIMUM AND MINIMUM HEAD LOSS/1000 = 4 SYSTEM CON F I G U RAT I O N NUMBER OF PIPES (p) = 8 NUMBER OF END NODES (J) = 7 NUMBER OF PRIMARY LOOPS (1) = 1 NUMBER OF SUPPLY NODES (f) = 1 NUMBER OF SUPPLY ZONES (z) = 1 Case: 0 RESULTS OBTAINED AFTER 8 TRIALS: ACCURACY = 0.00000 S IMULATION DESCRIPTION (L A B E L) P IPELINE R E SULTS STATUS CODE: XX -CLOSED PIPE CV -CHECK VALVE P IPE NODE NUMBERS FLOWRATE HEAD MINOR LINE HL+ML/ HL/ N AME #1 #2 LOSS LOSS VELO. 1000 1000 (gpm) (ft) (ft) (ft/s) (ft/ft) (ft/ft) P-1 VP-1 3-7 26.25 0.01 0.00 0.17 0.02 0.02 P-2 3-3 2-2 3.00 0.02 0.00 0.14 0.05 0.05 P-3 3-6 3-3 3.74 0.00 0.00 0.04 0.00 0.00 P-4 3-4 J-8 9.76 0.00 0.00 0.06 0.00 0.00 P-5 3-6 3-5 2.62 0.01 0.00 0.12 0.04 0.04 P-6 3-4 3-6 12.36 0.01 0.00 0.08 0.01 0.01 P-7 3-7 3-4 26.25 0.00 0.00 0.17 0.02 0.02 P-8 3-8 3-3 5.64 0.00 0.00 0.06 0.01 0.01 END NODE RESULTS NODE NODE EXTERNAL HYDRAULIC NODE PRESSURE NODE NAME TITLE DEMAND GRADE ELEVATION HEAD PRESSURE (gpm) (ft) (ft) (ft) (psi) 3-2 3.00 482.60 277.00 205.60 89.09 3-3 6.38 482.63 284.00 198.63 86.07 J-4 4.12 482.63 276.00 206.63 89.54 3-5 2.62 482.62 276.00 206.62 89.53 2-6 6.00 482.63 282.00 200.63 86.94 3-7 0.00 482.64 277.00 205.64 89.11 3-8 4.12 482.63 288.00 194.63 84.34 VP-1 ---- 482.65 275.00 207.65 89.98 SUMMARY OF I N F LOWS AND OUT F LOW S (+) INFLOWS INTO THE SYSTEM FROM SUPPLY NODES (-) OUTFLOWS FROM THE SYSTEM INTO SUPPLY NODES NODE FLOWRATE NODE NAME (gpm) TITLE VP-1 26.25 NET SYSTEM INFLOW = 26.25 NET SYSTEM OUTFLOW = 0.00 NET SYSTEM DEMAND = 26.25 •t'++ HYDRAULIC ANALYSIS COMPLETED 't"` Exhibit D (Fire Flow Model) K Y P I P E 4 a r • University of Kentucky Network Modeling Software r r r a Copyrighted by KYPIPE LLC a ✓ Version 3 - 11/01/2005 a • a Date & Time: Fri Feb 09 11:29:00 2007 INPUT DATA FILENAME F:\1056-J-1\10560005.DT2 TABULATED OUTPUT FILENAME F:\1056-J-1\10560005.OT2 POSTPROCESSOR RESULTS FILENAME F:\1056-J-1\10560005.RS2 *************aa****a.******a*a*a******aa.******* SUMMARY OF ORI G I NAL DATA U NITS SPECIFIED FLOWRATE = gallons/minute HEAD (HGL) = feet PRESSURE = psig P I P ELI N E DATA STATUS CODE: XX -CLOSED PIPE CV -CHECK VALVE P IPE NODE NAMES LENGTH DIAMETER ROUGHNESS MINOR N AME #1 #2 (ft) (in) COEFF. LOSS COEFF. P-1 VP-1 3-7 574.59 8.00 130.0000 0.00 P-2 3-3 3-2 536.34 3.00 130.0000 0.00 P-3 3-3 3-6 877.67 6.00 130.0000 0.00 P-4 3-4 3-8 805.91 8.00 130.0000 0.00 P-5 3-6 J-5 351.06 3.00 130.0000 0.00 P-6 3-4 3-6 967.30 8.00 130.0000 0.00 P-7 J-7 J-4 149.02 8.00 130.0000 0.00 P-8 3-6 3-3 876.97 6.00 130.0000 0.00 P UMP/LOSS ELEMENT DATA THERE IS A DEVICE AT NODE VP-1 DESCRIBED BY THE FOLLOWING DATA: (ID= 1) HEAD FLOWRATE EFFICIENCY (ft) (gpm) (8) 207.69 0.00 75.00 161.54 1150.00 75.00 41.08 2300.00 75.00 E ND NODE DATA NODE NODE EXTERNAL JUNCTION EXTERNAL NAME TITLE DEMAND ELEVATION GRADE (gpm) (ft) (ft) J-2 3.00 277.00 J-3 6.38 284.00 J-4 4.12 276.00 J-5 2.62 276.00 J-6 6.00 282.00 J-7 0.00 277.00 J-8 1004.13 288.00 VP-1 ---- 275.00 275.00 OUTPUT OPTION DATA OUTPUT SELECTION: ALL RESULTS ARE INCLUDED IN THE TABULATED OUTPUT ***WARNING*** NUMBER REQUESTED FOR MAXIMUM AND MINIMUM PRESSURES CANNOT EXCEED ONE HALF THE NUMBER OF JUNCTION NODES WITH ELEVATIONS DEFINED ***WARNING*** NUMBER REQUESTED FOR MAXIMUM AND MINIMUM VELOCITIES CANNOT EXCEED ONE HALF THE NUMBER OF PIPES ***WARNING*** NUMBER REQUESTED FOR MAXIMUM AND MINIMUM HEAD LOSS/1000 CANNOT EXCEED ONE HALF THE NUMBER OF PIPES MAXIMUM AND MINIMUM PRESSURES = 4 MAXIMUM AND MINIMUM VELOCITIES = 4 MAXIMUM AND MINIMUM HEAD LOSS/1000 = 4 S YSTEM CONFIGURATION NUMBER OF PIPES (p) = 8 NUMBER OF END NODES (7) = 7 NUMBER OF PRIMARY LOOPS (1) = 1 NUMBER OF SUPPLY NODES (f) = 1 NUMBER OF SUPPLY ZONES (z) = 1 Case: 0 RESULTS OBTAINED AFTER 6 TRIALS: ACCURACY = 0.00000 S IMULATION DES CRI P T I O N (LAB E L) P IPELINE RESULTS STATUS CODE: XX -CLOSED PIPE CV -CHECK VALVE P IPE NODE NUMBERS FLOWRATE HEAD MINOR LINE HL+ML/ HL/ N AME #1 #2 LOSS LOSS VELD. 1000 1000 (qpm) (ft) (ft) (ft/s) (ft/ft) (ft/ft) P-1 VP-1 3-7 1026.25 11.01 0.00 6.55 19.17 19.17 P-2 3-3 3-2 3.00 0.02 0.00 0.14 0.05 0.05 P-3 3-6 3-3 228.87 4.24 0.00 2.60 4.83 4.83 P-4 2-4 3-8 784.63 9.40 0.00 5.01 11.66 11.66 P-5 3-6 3-5 2.62 0.01 0.00 0.12 0.04 0.04 P-6 3-4 3-6 237.49 1.23 0.00 1.52 1.27 1.27 P-7 3-7 3-4 1026.25 2.86 0.00 6.55 19.17 19.17 P-B 3-3 3-8 219.49 3.92 0.00 2.49 4.47 4.47 PUMP/LOSS ELEMENT R E S ULT S INLET OUTLET PUMP EFFIC- USEFUL INCREMTL TOTAL #PUMPS #PUMPS NPSH NAME FLOWRATE HEAD HEAD HEAD ENCY POWER COST COST PARALLEL SERIES Avail. (qpm) (ft) (ft) (ft) (8) (Hp) (5) ($) (ft) -1 1026.25 0.00 170.31 170.3 ---- --- ---- ** ** 33.2 END NODE RESULTS NODE NODE EXTERNAL HYDRAULIC NODE PRESSURE NODE NAME TITLE DEMAND GRADE ELEVATION HEAD PRESSURE (qpm) (ft) (ft) (ft) (psi) 3-2 3.00 425.95 277.00 148.95 64.54 3-3 6.38 425.97 284.00 141.97 61.52 J-4 4.12 431.44 276.00 155.44 67.36 3-5 2.62 430.20 276.00 154.20 66.82 3-6 6.00 430.21 282.00 148.21 64.22 3-7 0.00 434.30 277.00 157.30 68.16 3-8 1004.13 422.05 288.00 134.05 58.09 VP-1 ---- 445.31 275.00 170.31 73.80 MAXIMUM AND M I N I MUM VALUES PRESSURES JUNCTION MAXIMUM JUNCTION MINIMUM NUMBER PRESSURES NUMBER PRESSURES (psi) (psi) VP-1 73.60 J-8 58.09 J-7 68.16 J-3 61.52 J-4 67.36 J-6 64.22 J-5 66.82 J-2 64.54 ✓ ELOCITIES PIPE MAXIMUM PIPE MINIMUM NUMBER VELOCITY NUMBER VELOCITY (ft/s) (ft/s) P-1 6.55 P-5 0.12 P-7 6.55 P-2 0.14 P-4 5.01 P-6 1.52 P-3 2.60 P-8 2.49 H L + M L / 1 0 0 0 PIPE MAXIMUM PIPE MINIMUM NUMBER HL+ML/1000 NUMBER HL+ML/1000 (ft/ft) (ft/ft) P-1 19.17 P-5 0.04 P-7 19.17 P-2 0.05 P-4 11.66 P-6 1.27 P-3 4.83 P-8 4.47 H L / 1 0 0 0 PIPE MAXIMUM PIPE MINIMUM NUMBER EL/1000 NUMBER HL/1000 (ft/ft) (ft/ft) P-1 19.17 P-5 0.04 P-7 19.17 P-2 0.05 P-4 11.66 P-6 1.27 P-3 4.83 P-8 4.47 SUMMARY OF INFLOWS AND OUT F LOW S (+) INFLOWS INTO THE SYSTEM FROM SUPPLY NODES (-) OUTFLOWS FROM THE SYSTEM INTO SUPPLY NODES NODE FLOWRATE NODE NAME (gpm) TITLE VP-1 1026.25 NET SYSTEM INFLOW = 1026.25 NET SYSTEM OUTFLOW = 0.00 NET SYSTEM DEMAND = 1026.25 aa.a+ HYDRAULIC ANALYSIS COMPLETED