HomeMy WebLinkAboutStaff Review STAFF REVIEW COMMENTS NO. 1 Project: EWING IRRIGATION (PP) - 08-00500219 PLANNING 1. Please remove the rectangle portion of land at the front of Lot 2. 2. The park at the northern corner of the property needs to be labeled. 3. Provide ownership information on abutting properties. 4. The title block needs to say "Preliminary Plat— Not for Record" 5. Please provide a general note stating the ownership and maintenance responsibility for the private access easement. 6. FYI, utility easements may be fenced if unlocked gates are provided as per Section 8.1.2.6 of the Subdivision Regulations. 7. Please clarify the acreage as ROW is being dedicated. 8. Remove existing structures on adjacent properties from the plat. 9. As a general FYI, chain link fences are considered visually offensive and will need to be screened from view at the site plan stage. Reviewed by: Matt Robinson Date: 11/24/08 ENGINEERING COMMENTS NO. 1 1. Our records indicate an existing 4-in Southwestern Gas Pipeline across the property seemingly parallel to Graham Rd. Please verify. 2. Please provide ownership information, sizing, design pressure, and transport product of all existing pipelines on the property. 3. Please clarify the 0.0303 Acre right-of-way dedication. Since Graham Rd. is classified as a major collector and is currently 70-ft wide, a 5-ft dedication across the property is required unless otherwise negotiated. 4. Please provide volume and page number on all existing easements. 5. Our records indicate that the 10-ft PUE shown adjacent to the property is actually a 10-ft Pipeline easement. Please verify. 6. Please show the iron rods associated with the lot corners and show that a lot corner is tied to City's horizontal control monument. 7. Please include the subdivision name, lot ownership information, and recordation information on all adjacent lots. 8. Our records indicate that the correct recordation information for the Brown Addition is Volume 2370, Page 61. Please verify. 9. Our records indicate that the correct recordation information for the Deuel Addition is Volume 4730, Page 244. Please verify. 10. We have no record of waterlines crossing Graham Rd. in the given locations. Are these existing or proposed waterlines? 11. Please label and show the limits of the current right-of-way width on Graham Rd. in front of the property. 12. Please clearly indicate the limits of Line "L1." 13. General Note #7 should specify that the property is located within the "Graham" Sewer Impact Fee Area. Reviewed by: Erika Bridges Date: 11/24/08 GENERAL ELECTRICAL COMMENTS 1. See final plat. Reviewed by: Sam Weido Date: 11-19-08