HomeMy WebLinkAboutApplication #.115144
4.- ,
FOR OFFI E USE ONL
IPea CASE
CITY OF COT.I.FGE STATION DATE SUBMITTED: (J' )1 • Vb
Planning o•Development Services
10''� 7.
PRELIMINARY PLAT APPLICATION CLi
The following items must be submitted by an established filing deadline date for P &Z Commission
consideration.
MINIMUM SUBMITTAL REQUIREMENTS:
X $400 Filing Fee
N/A$100 Variance Request to Subdivision Regulations (if applicable)
X Application completed in full.
X Fourteen (14)folded copies of plat. (A revised mylar original must be submitted after staff review.)
X A copy of the attached checklist with all items checked off or a brief explanation as to why they are not.
N/A Rezoning Application if zone change is proposed.
N/A Parkland Dedication requirement approved by the Parks& Recreation Board, please provide proof of
approval(if applicable).
Date of Preapplication Conference: There have been several meetings with staff regarding this plat
NAME OF SUBDIVISION Spring Creek Commons
SPECIFIED LOCATION OF PROPOSED SUBDIVISION located at the northeast corner of the
intersection of W.D. Fitch Parkway and SH6
APPLICANTIPROJECT MANAGER'S INFORMATION (Primary Contact for the Project):
Name Mitchell &Morgan, LLP C/O Veronica J.B. Morgan,P.E., C.F.M.
Street Address 511 University Drive, Suite 204 City College Station
State Texas Zip Code 77840 E-Mail Address v( mitcheIlandmorgan.com
Phone Number (979)260-6963 Fax Number(979) 260-3564
PROPERTY OWNER'S INFORMATION (ALL owners must be identified. Please attach an additional sheet for
multiple owners):
Name Corinth Properties C/O Frank Mihalopoulos
Street Address 4645 N. Central Expressway, Suite 200 City Dallas
State Texas Zip Code 75205 E-Mail Address franks corinthprop.com
Phone Number (214)219-5600 Fax Number(214) 219-5616
*See Additional Sheet.
ARCHITECT OR ENGINEER'S INFORMATION:
Name Mitchell & Morgan, LLP C/O Veronica J.B. Morgan, P.E., C.F.M.
Street Address 511 University Drive, Suite 204 City College Station
State Texas Zip Code 77840 E-Mail Address v(c�mitchellandmorgan.com
Phone Number (979)260-6963 Fax Number (979) 260-3564
Total Acres Of Subdivision 47.717 acres R-O-W Acreage 3.372 acres Total#Of Lots 15
Number Of Lots By Zoning District 15 / c-1
Average Acreage Of Each Residential Lot By Zoning District
N/A / /
Floodplain Acreage .43 acres
Are you proposing to dedicate park land by acreage or fee in lieu of land? N/A
Are you proposing to o develop the park or n dedicate the development fee?(Check one) -N/A
A statement addressing any differences between the Preliminary Plat and approved Master Plan(if applicable)
This prelirninarY plat contains different lot configurations than the previously approved preliminary plat. This
is due to different end users than was contemplated with the prior plat and more definitive site layouts are now
known.
Requested variances to subdivision regulations&reason for same Se: R' r sheep.
Requested oversize
eq participation Oversize participation will be requested on the sheet, Lakeway Drive as welt
as on the 12" waterline contained within Lakeway Drive and shown on the City Water Master Plan. Impact
studies for both are forthcoming which will demonstrate that a smaller street and waterline would be sufficient
dandle the proposed development.
Parkland Dedication due prior to filing the Final Plat •
ACREAGE
N/A #of Acres to be dedicated NIA #of acres in floodplain
N/A #of acres in detention N/A #of acres in greenways
*(Plus the trail connection to Holleman and signage, landscaping improvements on this trail addition)
OR
FEE IN LIEU OF LAND:
N/A # of Single-Family Dwelling Units X$556=$ N/A
WA (date)Approved by Parks& Recreation Board
*Projects that were vested prior to January 1, 2008, per Chapter 245 of the Texas Local Government Code may be assessed a
afferent amount. Please contact City staff for additional information.
The applicant has prepared This application and ries that the facts stated herein and exhibits attached hereto are true and correct
The undersigned approval by the City of College Station of the above identified plat and attests that all respective
.hase_e tr .klea>fffm this applicatica IFMISAPPLICATION IS FtL .8Y 1l4wo OTHER 1HAN THE OAR OF THE
PROPERTY, IS APPLICATION MUST BE ACCOMPANIED BY A POWER OF ATTORNEY STATEMENT FROM THE OWNER_
Corinth Pro r. c.04.-AtDate
Signature and Title c� per P<
f
7
PROPERTY OWNER'S INFORMATION
Name St Joseph Health System C/O John J. Buckley
Street Address 2801 Franciscan Drive City Bryan
State Texas Zip Code 77802 E-Mail Address jbuddevettst iosenh.oro
Phone Number 1979)776-5969 Fax Number
911j(A44?
gr/r/tv
9L
S Joseph Health System Date
Signature and Title
Name SDrinoCreek Holding C/O Chuck Ellison
Street Address P.O. Box 10103 City CoNeoe Station
State Texas Zip Code 77842 E-Mail Address chuciaellisonlaw.com
Phone Number J979)696-9889 Fax Number (979)693-8819
Spring Creek Holding Date
Signature and Title
PROPERTY OWNER'S INFORMATION
Name St Joseph Health System C/O John J. Buckley
Street Address 2801 Franciscan Drive City Bryan
State Texas Zip Code 77802 E-Mail Address jbuddevtl st ioseah.oro
Phone Number j979)776-5969 Fax Number
St.Joseph Health System Date
Signature and Title
Name Sprint Creek Holding C/O Chuck ENison
Street Address P.O. Box 10103 City College Station
State Texas Zip Code 77842 E-Mail Address chuckCctellisonlaw.com
Phone Number (979)696-9889 Fax Number (979) 693-8819
49C- fri4vatir., 'C
Spring Creek Holding Date
Signature and Title
SUBMIT APPLICATION AND THIS
QTY OF COLLEGE STATION LIST CHECKED OFF WITH 13
c-Daietypeala Serrias FOLDED COPIES OF PLAT FOR REVIEW
PRELIMINARY PLAT MINIMUM REQUIREMENTS
(ALL CITY ORDINANCES MUST BE MET)
INCLUDING BUT NOT LIMITED TO THE FOLLOWING:
N/A 1. Mylar original of approved master plan (Mylar must be on file or submitted before the preliminary
plat will be reviewed).
2. Drawn on 24'1x 36' sheet to scale of 100' per inch or larger. Include the words "PRELIMINARY
PLAT - NOT FOR RECORD' in letters 1/2' high. If more than 1 sheet, an index sheet showing
entire subdivision at a scale of 500 feet per inch or larger.
® 3. Vicinity map which includes enough of surrounding area to show general location of subject
property in relationship to College Station and its City Limits. No scale required but include north
arrow.
® 4. Title Block with the following information:
® Name and address of subdivider, recorded owner, planner, engineer and surveyor.
® Proposed name of subdivision. (Subdivision name & street names will be approved
through Brazos County 911.)(Replats need to retain original subdivision name.)
® Date of preparation. (INCLUDE DATE THE PLAT WAS SUBMITTED AND THE DATES
OF ANY REVISIONS ON THE PLAT)
® Engineer's scale in feet.
0 Total area intended to be developed.
• 5. North Arrow.
® 6. Location of current city limit lines and current zoning district boundary.
® 7. Subdivision boundary indicated by heavy lines. Boundary must include all of parent tract.
® 8. Descriptions by metes and bounds of the subdivision which shall close within accepted land survey
standards. (Labeled on boundary lines, not separate metes and bounds
9. Primary control points or descriptions and ties to such control point, to which , later, all dimensions,
angles, bearings, block numbers, and similar data shall be referred. The plat shall be located with
respect to a corner of the survey or tract, or an original corner of the original survey of which it is a
Part.
10. Name of contiguous subdivisions and names of owners of contiguous parcels of unsubdivided
land, and an.inchcation mhether or not cortiguous properties are Matted.
® 11. Location of the 100 Year Floodplain and Floodway, if applicable, according to the most recent
available data.
g 12. Topographic informatt , including contours at two foot (2 ft.) intervals wood
elevation of streams. , ed areas, and flowline
13. Proposed land uses (In compliance with Land Use Plan).
N/A 14. Proposed zoning changes, if any, submit formal rezoning request.
® 15. The location and description with accurate dimensions, bearings or deflection angles and radii,
area, center angle, degree of curvature, tangent distance and length of all curves for all of the
following: (Show existing items that are intersecting or contiguous with the boundary of or forming
a boundary with the subdivision, as well as, those within the subdivision).
Existing Proposed
® Streets. Continuous or end in a cul-de-sac, stubbed out streets must end into a temp.
turn around unless they are shorter than 100 feet.
Eg ® Public and private R.O.W. locations and widths. (All existing and proposed R.O.W.'s
sufficient to meet Thoroughfare Plan.)
N/A ® Street offsets and/or intersection angles meet ordinance.
N/A N/A Alleys.
N/A N/A Reserve tracts.
N/A N/A Well site locations.
® N/A Pipelines. If carrying flammable gas or fuel, also show size of line, design
product transported through the line. g pressure and
® ® Utility Services. (Water& Sanitary Sewer)All existing and proposed utilities of sufficient
size/depth to meet the utility master plan and any future growth areas.
® ® Easements.
® ® Drainage Structures and improvements including underground storm sewer and all
overland systems(flow line of existing watercourses)and showing where these will
discharge. Proposed channel cross sections, if any.
Ej A number or letter to identify each lot or site and each block.
• ® N/A Greenbelt area/park tinkages/parkland dedication(All proposed dedications must be
reviewed by the Parks and Recreation Board prior to P&Z Commission consideration.)
N/A N/A Public areas
N/A NIA faOther public improvements, including but not limited to parks, schools and other public
cilities
16. Proposed phasing. Each phase must be able to stand alone to meet ordinance requirements and
infrastructure costs should be distributed evenly throughout the subdivision.
® 17. Are there impact fees associated with this development? ®Yes ❑ No
El 18. If requestingoversize
participation items, are the necessary impact studies included?
['Yes
EJN/A
#P -411144FOR OFF C USE ON.Y
P&Z CASE NO.: � 1 •
CITY OF COLLEGE STATION
DATE SUBMITTED: , �( -O•
Planning&Development Services
PRELIMINARY PLAT APPLICATION
-
The following items must be submitted by an established filing deadline date for P &Z Commission
consideration.
MINIMUM SUBMITTAL REQUIREMENTS:
id X $400 Filing Fee
N/A$100 Variance Request to Subdivision Regulations (if applicable)
X Application completed in full.
X Fourteen (14) folded copies of plat. (A revised mylar original must be submitted after staff review.)
X A copy of the attached checklist with all items checked off or a brief explanation as to why they are not.
N/A Rezoning Application if zone change is proposed.
N/A Parkland Dedication requirement approved by the Parks & Recreation Board, please provide proof of
approval (if applicable).
Date of Preapplication Conference: There have been several meetings with staff regarding this plat
NAME OF SUBDIVISION Spring Creek Commons
SPECIFIED LOCATION OF PROPOSED SUBDIVISION located at the northeast corner of the
intersection of W.D. Fitch Parkway and SH6
APPLICANT/PROJECT MANAGER'S INFORMATION (Primary Contact for the Project):
Name Mitchell & Morgan, LLP C/O Veronica J.B. Morgan, P.E., C.F.M.
Street Address 511 University Drive, Suite 204 City College Station
State Texas Zip Code 77840 E-Mail Address v[a,mitchellandmorgan.com
Phone Number (979) 260-6963 Fax Number(979) 260-3564
PROPERTY OWNER'S INFORMATION (ALL owners must be identified. Please attach an additional sheet for
multiple owners):
Name Corinth Properties C/O Frank Mihalopoulos
Street Address 4645 N. Central Expressway, Suite 200 City Dallas
State Texas Zip Code 75205 E-Mail Address franks corinthprop.com
Phone Number (214) 219-5600 Fax Number (214) 219-5616
*See Additional Sheet.
ARCHITECT OR ENGINEER'S INFORMATION:
Name Mitchell & Morgan, LLP C/O Veronica J.B. Morgan, P.E., C.F.M.
Street Address 511 University Drive, Suite 204 City College Station
State Texas Zip Code 77840 E-Mail Address v snitchellandmorgan.com
Phone Number (979)260-6963 Fax Number (979) 260-3564
Total Acres Of Subdivision 47.717 acres R-O-W Acreage 3.372 acres Total#Of Lots 15
Number Of Lots By Zoning District 15 / c-1
Average Acreage Of Each Residential Lot By Zoning District:
N/A /
Floodplain Acreage .43 acres
Are you proposing to dedicate park land by acreage or fee in lieu of land? N/A
Are you proposing to o develop the park or❑ dedicate the development fee? (Check one) - N/A
A statement addressing any differences between the Preliminary Plat and approved Master Plan (if applicable)
This preliminary plat contains different lot configurations than the previously approved preliminary plat. This
is due to different end users than was contemplated with the prior plat and more definitive site layouts are now
known.
Requested variances to subdivision regulations & reason for same None
Requested oversize participation Oversize participation will be requested on the sheet, Lakewav Drive as well
as on the 12" waterline contained within Lakewav Drive and shown on the City Water Master Plan. Impact
studies for both are forthcoming which will demonstrate that a smaller street and waterline would be sufficient
to handle the proposed development.
Parkland Dedication due prior to filing the Final Plat:
ACREAGE:
N/A .#of Acres to be dedicated N/A #of acres in floodplain
N/A #of acres in detention N/A #of acres in greenways
*(Plus the trail connection to Holleman and signage, landscaping improvements on this trail addition)
OR
FEE IN LIEU OF LAND:
N/A #of Single-Family Dwelling Units X $556 =$ N/A
N/A (date)Approved by Parks& Recreation Board
*Projects that were vested prior to January 1, 2008, per Chapter 245 of the Texas Local Government Code may be assessed a
different amount. Please contact City staff for additional information.
The applicant has prepared this application and certifies that the facts stated herein and exhibits attached hereto are true and correct.
The undersigned hereby requests approval by the City of College Station of the above identified plat and attests that,ill respective
owners have been identified on this application. IF THIS APPLICATION IS FILED BY ANYONE OTHER THAN THE OWNER OF THE
PROPERTY,T IS APPLICATION MUST BE ACCOMPANIED BY A POWER OF ATTORNEY STATEMENT FROM THE OWNER.
i
Corinth Pro:erties c�.,ti/ski 4. ÷ Date
Signature and Title er..*-104,90,C'c.P.
/ i 1...1 vI'l✓ - C�CZ—
PROPERTY OWNER'S INFORMATION
Name St. Joseph Health System C/O John J. Buckley
Street Address 2801 Franciscan Drive City Bryan
State Texas Zip Code 77802 E-Mail Address jbuckleyest-ioseph.orq
Phone Number (979) 776-5969 Fax Number
4 kW; At,7 9tz rfr/W
S .Joseph Health System Date
Signature and Title
Name Spring Creek Holding C/O Chuck Ellison
Street Address P.O. Box 10103 City College Station
State Texas Zip Code 77842 E-Mail Address chuckaellisonlaw.com
Phone Number (979) 696-9889 Fax Number (979) 693-8819
Spring Creek Holding Date
Signature and Title
PROPERTY OWNER'S INFORMATION
Name St. Joseph Health System CIO John J. Buckley
Street Address 2801 Franciscan Drive City Bryan
State Texas Zip Code 77802 E-Mail Address jbuckleyast joseph.orq
Phone Number (979) 776-5969 Fax Number
St. Joseph Health System Date
Signature and Title
Name Spring Creek Holding C/O Chuck Ellison
Street Address P.O. Box 10103 City College Station
State Texas Zip Code 77842 E-Mail Address chucks ellisonlaw.com
Phone Number (979) 696-9889 Fax Number (979) 693-8819
Spring Creek Holding Date
Signature and Title
SUBMIT APPLICATION AND THIS
LIST CHECKED OFF WITH 13
CITY OF COLLEGE STATION FOLDED COPIES OF PLAT FOR REVIEW
Planning crDevelopment Servicer
PRELIMINARY PLAT MINIMUM REQUIREMENTS
(ALL CITY ORDINANCES MUST BE MET)
INCLUDING BUT NOT LIMITED TO THE FOLLOWING:
N/A 1. Mylar original of approved master plan (Mylar must be on file or submitted before the preliminary
plat will be reviewed).
• 2. Drawn on 24" x 36" sheet to scale of 100' per inch or larger. Include the words "PRELIMINARY
PLAT - NOT FOR RECORD" in letters 1/2" high. If more than 1 sheet, an index sheet showing
entire subdivision at a scale of 500 feet per inch or larger.
® 3. Vicinity map which includes enough of surrounding area to show general location of subject
property in relationship to College Station and its City Limits. No scale required but include north
arrow.
® 4. Title Block with the following information:
® Name and address of subdivider, recorded owner, planner, engineer and surveyor.
® Proposed name of subdivision. (Subdivision name & street names will be approved
through Brazos County 911.) (Replats need to retain original subdivision name.)
® Date of preparation. (INCLUDE DATE THE PLAT WAS SUBMITTED AND THE DATES
OF ANY REVISIONS ON THE PLAT)
® Engineer's scale in feet.
® Total area intended to be developed.
® 5. North Arrow.
® 6. Location of current city limit lines and current zoning district boundary.
® 7. Subdivision boundary indicated by heavy lines. Boundary must include all of parent tract.
® 8. Descriptions by metes and bounds of the subdivision which shall close within accepted land survey
standards. (Labeled on boundary lines, not separate metes and bounds description.)
® 9. Primary control points or descriptions and ties to such control point, to which , later, all dimensions,
angles, bearings, block numbers, and similar data shall be referred. The plat shall be located with
respect to a corner of the survey or tract, or an original corner of the original survey of which it is a
part.
® 10. Name of contiguous subdivisions and names of owners of contiguous parcels of unsubdivided
land, and an indication whether or not contiguous properties are platted.
® 11. Location of the 100 Year Floodplain and Floodway, if applicable, according to the most recent
available data.
Z 12. Topographic information, including contours at two foot (2 ft.) intervals, wooded areas, and flowline
elevation of streams.
® 13. Proposed land uses (In compliance with Land Use Plan).
N/A 14. Proposed zoning changes, if any, submit formal rezoning request.
® 15. The location and description with accurate dimensions, bearings or deflection angles and radii,
area, center angle, degree of curvature, tangent distance and length of all curves for all of the
following: (Show existing items that are intersecting or contiguous with the boundary of or forming
a boundary with the subdivision, as well as, those within the subdivision).
Existing Proposed
® ® Streets. Continuous or end in a cul-de-sac, stubbed out streets must end into a temp.
turn around unless they are shorter than 100 feet.
® ® Public and private R.O.W. locations and widths. (All existing and proposed R.O.W.'s
sufficient to meet Thoroughfare Plan.)
N/A ® Street offsets and/or intersection angles meet ordinance.
N/A N/A Alleys.
N/A N/A Reserve tracts.
N/A N/A Well site locations.
® N/A Pipelines. If carrying flammable gas or fuel, also show size of line, design pressure and
product transported through the line.
® Z Utility Services. (Water & Sanitary Sewer) All existing and proposed utilities of sufficient
size/depth to meet the utility master plan and any future growth areas.
® ® Easements.
® ® Drainage Structures and improvements including underground storm sewer and all
overland systems (flow line of existing watercourses) and showing where these will
discharge. Proposed channel cross sections, if any.
® ® A number or letter to identify each lot or site and each block.
® N/A Greenbelt area/park linkages/parkland dedication (All proposed dedications must be
reviewed by the Parks and Recreation Board prior to P & Z Commission consideration.)
N/A N/A Public areas
N/A N/A Other public improvements, including but not limited to parks, schools and other public
facilities
® 16. Proposed phasing. Each phase must be able to stand alone to meet ordinance requirements and
infrastructure costs should be distributed evenly throughout the subdivision.
® 17. Are there impact fees associated with this development? ® Yes ❑ No
® 18. If requesting oversize participation items, are the necessary impact studies included?
❑Yes
®No
❑N/A