Loading...
HomeMy WebLinkAboutApplication FOR OFFICE E ONL, (4 Ill I 51 I I 44 P8ZCASE NO.: &h6 DATE SUBMITTED: 'fin CITY OF COLLEGE STATION • A Planning d Development Services I F SITE PLAN APPLICATION Cif" MINIMUM SUBMITTAL REQUIREMENTS X Site plan application completed in full. N/A $200.00 Application Fee. N/A $200.00 Development Permit Application Fee. N/A $600.00 Public Infrastructure Inspection Fee if applicable. (This fee is payable if construction of a public waterline, sewerline, sidewalk, street or drainage facilities is involved.) X Fourteen (14) folded copies of site plan X One (1) folded copy of the landscape plan. X Non-Residential Architectural Standards Application and associated documents (if applicable) N/A Traffic Impact Analysis (if applicable for non-residential buildings). X A copy of the attached site plan checklist with all items checked off or a brief explanation as to why they are not checked off. N/A Parkland Dedication requirement approved by the Parks & Recreation Board, please provide proof of approval (if applicable). Date of Preapplication Conference: NAME OF PROJECT A New Bath House for Thomas Park Pool ADDRESS 1300 James Parkway,College Station,Texas 77842 LEGAL DESCRIPTION College Hills,Acres 16.10,Thomas Park APPLICANT/PROJECT MANAGER'S INFORMATION (Primary Contact for the Project): Name Steven Schloss,The Arkitex Studio, Inc. Street Address 308 N.Bryan Ave City Bryan State TX Zip Code 77803 E-Mail Address sschloss@arkitex.com Phone Number (979)821-2635 Fax Number (979)775-8224 PROPERTY OWNER'S INFORMATION: Name City of College Station,Pete Vanecek Street Address 1101 Texas Ave City College Station State TX Zip Code 77840 E-Mail Address pvanecek@cstx.gov Phone Number (979)764-3412 Fax Number (979)764-3773 ARCHITECT OR ENGINEER'S INFORMATION: / Name Eva Read-Warden,AIA,The Arkitex Studio, Inc. ,' Street Address 308 N.Bryan Ave. City Bryan State TX Zip Code 77803 E-Mail Address eva@arkitex.com Phone Number (979)821-2635 Fax Number (979)775-8224 1 of 6 OTHER CONTACTS (Please specify type of contact, i.e. project manager, potential buyer, local contact, etc.) Name Street Address City State Zip Code E-Mail Address Phone Number Fax Number CURRENT ZONING RO PRESENT USE OF PROPERTY Public park and swimming pool. PROPOSED USE OF PROPERTY Same. VARIANCE(S) REQUESTED AND REASON(S) # OF PARKING SPACES REQUIRED #OF PARKING SPACES PROVIDED MULTI-FAMILY RESIDENTIAL N/A PARKLAND DEDICATION N/A (Fees due prior to the issuance of a Building Permit) Total Acreage #of Multi-Family Dwelling Units Floodplain Acreage X$731* = $ Housing Units # of acres in floodplain # of 1 Bedroom Units # of acres in detention #of 2 Bedroom Units # of acres in greenways # of 3 Bedroom Units date dedication approved by Parks & Recreation Advisory Board #of 4 Bedroom Units COMMERCIAL FOR 2 BEDROOM UNITS ONLY N/A Total Acreage # Bedrooms = 132 sq. ft. Building Square Feet 1332 # Bedrooms < 132 sq. ft. Floodplain Acreage N/A * Projects that were vested prior to January 1, 2008, per Chapter 245 of the Texas Local Government Code may be assessed a different amount. Please contact city staff for additional information. The applicant has prepared this application and certifies that the facts stated herein and exhibits attached hereto are true and correct. July 28,2008 Signature of Owrier;Agent or Applicant Date 2 of 6 SUBMIT APPLICATION AND THIS LIST CHECKED OFF WITH 14 FOLDED COPIES OF SITE PLAN FOR REVIEW (irrif" CITY OF COLLEGE STATION Planning te,'Development Services SITE PLAN REQUIREMENTS LY ORD INCLUDING BUT NOT LIMITED TO THE FOLLOWING: M ✓ Sheet size - 24" x 36" (minimum). ✓ A key map (not necessarily to scale). _.`gym a5 -Po 01 'Q. �a,.k• Title block to include: c-h-�l,�_=- �e-v't Si-- d 150144-1 M ✓ Name, address, location, and legal description M ✓ Name, address, and telephone number of applicant 10 \,/'Name, address, and telephone number of developer/owner (if differs from applicant) ❑ ANS' Name, address, and telephone number of architect/engineer (if differs from applicant) 11Q ✓Date of submittal -.-❑ N/A Total site area 110 ✓' North arrow. ✓ Scale should be largest standard engineering scale possible on sheet. DO Ownership and current zoning of parcel and all abutting parcels. ❑ WA The total number of multi-family buildings and units to be constructed on the proposed project site. ❑06 The density of dwelling units per acre of the proposed project. The gross square footage of all buildings and structures and the proposed use of each. If different uses are to be located in a single building, show the location and size of the uses within the building. Building separation is a minimum of 15 feet w/o additional fire protection. Locations of the following on or adjacent to the subject site: Designate between existing and proposed ❑ t11'A Phasing. Each phase must be able to stand alone to meet ordinance requirements. v% Buildings (Existing and Proposed). DO ✓ Setbacks according to UDO, Article 5. Geography ❑ leg Water courses. )(1 . • 100 yr. floodplain and floodway (if applicable) on or adjacent to the proposed project site, Please note if there is none on the site with confirming FEMA/FIRM map number. Existing topography (2' max or spot elevations) and other pertinent drainage information. (If plan has too much information, show drainage on separate sheet.) Proposed grading (1' max for proposed or spot elevations) and other pertinent drainage information. (If plan has too much information, show drainage on separate sheet.) Streets, Parking, and Sidewalks M " Existing streets and sidewalks (R.O.W.). le ✓ Existing Driveways, both opposite and adjacent to the site according to UDO, Section 7.3. U WA/Proposed drives. Minimum drive aisle width according to UDO, Section 7.3 U NIA/Indicate proposed driveway throat length according to UDO, Section 7.3. 4 of 6 ❑ N/�/ Proposed curb cuts. • For each proposed curb cut (including driveways, streets, alleys, etc.) locate existing curb cuts on the same and opposite side of the street to determine separation distances between existing and proposed curb cuts. ❑ N/A Proposed curb and pavement detail. • A 6" raised curb is required around all edges of all parts of all paved areas without exception. (To include island, planting areas, access ways, dumpster locations, utility pads, etc.) No exception will be made for areas designated as "reserved for future parking". ❑ NVK Proposed medians. Da v" Proposed sidewalks (both public and private). 04, Proposed pedestrian/bike circulation and facilities for non-residential buildings (UDO, Section 7.9) ® /Off-Street parking areas with parking spaces drawn, tabulated, and dimensioned. • Designate number of parking spaces required by ordinance and provided by proposal. ® Handicap parking spaces. Parking Islands drawn and dimensioned with square footage calculated according to UDO, Section 7.2 or 7.9 for non-residential buildings. ✓ Parking setback from R.O.W. to curb of parking lot as required. DO v- Wheelstops may be required when cars overhang onto property not owned by the applicant or where there may be conflict with pedestrian or bike facilities, handicap accessible routes or above ground utilities, signs or other conflicts. DIS ✓'Security gates, showing swing path and design specs with colors. '-'Guardrails. Include design and colors. M 'Traffic Impact Analysis for non-residential development (UDO, Section 7.9) X Please note if none is required. %/' Will there be access from a TxDOT R.O.W.? Yes ❑ No X If yes, then TxDOT permit must be submitted with this application. Easements and Utilities Items not check will be provided with forthcoming Civil drawings. ❑ Easements - clearly designate as existing or proposed and type (utility, access, etc.) Utilities (noting size and designate as existing or proposed) within or adjacent to the proposed site. ❑ Electric service plan including building transformer and pull box locations, above ground and underground service connections to buildings, and all meter locations. ❑ Water Design Report and/or Fire Flow Report (if applicable) ❑ Sewer Design Report (if applicable) ❑ Drainage Report with a Technical Design Summary. ❑ Meter locations, existing and proposed (must be located in public R.O.W. or public utility easement). ❑ Provide a water and sanitary sewer legend to include o Minimum water demands o Maximum water demands o Average water demands in gallons per minute, and o Maximum sewer loadings in gallons per day Xi Will there be any utilities in TxDOT R.O.W.? Yes ❑ No M If yes, then TxDOT permit must be submitted with this application. 5 of 6 Fire Protection D0 Show fire lanes. Fire lanes with a minimum of 20 feet in width with a minimum height clearance of 14 feet must be established if any portion of the proposed structure is more than 150 feet from the curb line or pavement edge of a public street or highway. Show proposed and existing fire hydrants. Fire hydrants must be located on the same side of a major street as a project, and shall be in a location approved by the City Engineer. Any structure in any zoning district other than R-1, R-1A, or R-2 must be within 300 feet of a fire hydrant as measured along a public street7ighway or designated fire lane. NOTE: Fire hydrants must be operable and accepted by the City, and drives must have an all weather surface before a building permit can be issued. Will building be sprinkled? Yes ❑ No X If the decision to sprinkle is made after the site plan has been approved, then the plan must be resubmitted. ❑ If Yes, Show fire department connections. FDC's should be within 150' of the fire hydrant. In no case shall they be any further than 300' apart, and they shall be accessible from the parking lot without being blocked by parked cars or a structure. Landscaping Landscape plans as required in Section 7.5 or 7.9 of the Unified Development Ordinance. The landscaping plan can be shown on a separate sheet if too much information is on the original site plan. If requesting protected tree points, then those trees need to be shown appropriately barricaded on the landscape plan. Attempt to reduce or eliminate plantings in easements. Include information on the plans such as: �Q ✓ required point calculations ▪ ✓ additional streetscape points required. Streetscape compliance is required on all streets. DO calculations for# of street trees required and proposed (proposed street tree points will accrue toward total landscaping points.) • proposed new plantings with points earned • proposed locations of new plantings screening of parking lots, 50% of all shrubs used for screening shall be evergreen. no-m110 screening of dumpsters, concrete retaining walls, off street loading areas, utility connection points, or other areas potentially visually offensive. • . -existing landscaping to remain —» x show existing trees to be barricaded and barricade plan. Protected points will only be awarded if barricades are up before the first development permit is issued. DAN A Buffer as required in Section 7.6 of the Unified Development Ordinance. --� Show irrigation system plan. (or provide note on how irrigation system requirement will be met prior to issuance of C.O.) All plans must include irrigation systems for landscaping. Irrigation meters are separate from the regular water systems for buildings and will be sized by city according to irrigation demand submitted by applicant and must include backflow prevention protection. Is there any landscaping in TxDOT R.O.W.? Yes ❑ No 110 If yes, then TxDOT permit must be submitted at the time of application. Other )Q ./ Common open spaces sites ✓ Loading docks ..�-� Detention ponds X ✓Retaining walls r$0 Sites for solid waste containers with screening. Locations of dumpsters are accessible but not visible from streets or residential areas. Gates are discouraged and visual screening is required. (Minimum 12 x 12 pad required.) Are there impact fees associated with this development? Yes ❑ No )D NOTE: Signs are to be permitted separately. 6 of 6