HomeMy WebLinkAboutStaff Review STAFF REVIEW COMMENTS NO. 2
Project: POOHS PARK (FP-REPLAT) - 08-00500103
PLANNING
1. Please change the title of the replat to read as follows: "Final Plat of the Pooh's Park
Subdivision Section One Lots 1R & 2R, Block 2 Being a Replat of Pooh's Park Subdivision
Section One Lot 1, Block 2 College Station, Brazos County, Texas".
2. Please relabel "East Holleman Drive" to "Holleman Drive East".
3. Please relabel "Lassie Drive" to "Lassie Lane".
Reviewed by: Matt Robinson Date: 7/15/08
ENGINEERING COMMENTS NO. 3
1. Please indicate the current right-of-way width of Holleman Drive East on the original plat and
replat rather than "variable width" or"100' ROW."
2. The existing boundary line should remain and additional line should be added within the
property boundary denoting the right-of-way dedication.
3. Please add a note to the plat indicating that the existing driveway to Holleman will be
removed when the site redevelops and access for both lots will be taken via the joint access
easement.
4. Please remove "New" from the Joint Access Easement label.
5. FYI ... It would be helpful to have the drawing scale noted more prominently on the plat.
Reviewed by: Erika Bridges Date: 7/21/08
Home of Texas A&M University
STAFF REVIEW COMMENTS NO. 1
Project: POOHS PARK (FP-REPLAT) - 08-00500103
PLANNING
1. Please show a vicinity map, which includes a north arrow and that shows the general
location of the subject property in relationship to College Station and its City Limits. The
vicinity map as shown does not appear to match up with where the subject property is
located.
2. Please change the title of the replat to read as follows: "Final Plat of the Pooh's Park
Subdivision Lots 1R & 2R, Block 2 Being a Replat of Pooh's Park Subdivision Lot 1, Block 2
College Station, Brazos County, Texas"
3. Please provide a label for the curve data.
4. Please remove note #4
Reviewed by: Matt Robinson Date: 6/13/08
ENGINEERING COMMENTS NO. 1
1. Please remove all utilities, structures, and setbacks from the original plat.
2. The public utility easements need to be labeled "P.U.E."
3. Please specify the right-of-way width for this portion of Holleman Dr. E.
4. Please show all easements on the replat.
5. The title block needs a submittal date for the replat.
6. Please delete the text below Survey Note#7.
7. Please indicate the proposed right-of-way dedication for Holleman Dr. E. in accordance with
the City's Thoroughfare Plan.
8. In order to meet driveway spacing requirements, a shared access easement needs to be
provided across the front of Lots 1R and 2R adjacent to Holleman Dr. E.
Reviewed by: Erika Bridges Date: 6/16/08
ELECTRICAL COMMENTS REQUIRING IMMEDIATE ATTENTION
1. Developer provides temporary blanket easement for construction purposes.
2. Developer provides easements for electric infrastructure as installed for electric lines
(including street lights).
3. Additional easements may be required for electric service
GENERAL ELECTRICAL COMMENTS
1. Developer installs conduit per City specs and design.
2. City will provide drawings for conduit installation.
3. Developer provides 30' of rigid or IMC conduit for riser poles. City installs riser.
4. Developer to intercept existing conduit at designated transformers and extend as required.
5. If conduit does not exist at designated transformer, developer to furnish and install conduit
as shown on electrical layout.
6. Developer pours transformer pad(s) per City specs and design.
7. Developer installs pull boxes and secondary pedestals as per City specs and design (pull
boxes and secondary pedestals provided by the City).
NOTE: Any changes made to the plans, that have not been requested by the City of College Station, must be
explained in your next transmittal letter and "bubbled" on your plans. Any additional changes on these plans
that have not been pointed out to the City,will constitute a completely new review. 2 of 3
8. Developer provides digital AutoCAD 2000 or later version of plat and/or site plan. Email to
bread@cstx.gov.
9. Developer provides load data for project.
10. To discuss any of the above electrical comments please contact Brent Read at
979.764.5026.
Reviewed by: Brent Read Date: June 13, 2008
FIRE
1) No Comments
Reviewed by: Jerry Duffey, Deputy Fire Marshal Date: June 10, 2008
SANITATION
1. Sanitation is okay with this project.
Reviewed by: Wally Urrutia Date: June 11, 2008
NOTE: Any changes made to the plans, that have not been requested by the City of College Station, must be
explained in your next transmittal letter and "bubbled" on your plans. Any additional changes on these plans
that have not been pointed out to the City,will constitute a completely new review. 3 of 3