HomeMy WebLinkAboutApplication 2vogoa 9I . S
(1/4," FOR OFFICE � • L
P8Z CASE •
NO.: 11 r 1
•
On OF COLLEGE STATION SUBIMIl`rED: '' ,,
PimuNimg 6 Da dspmsr Strokes
SITE PLAN APPLICATION 41)
MINIMUM SUBMITTAL REQUIREMENTS
✓ Site plan application completed in full.
✓ $200.00 Application Fee. '
r^ ✓ $200.00 Devebpm ent Permit Application Fee.
$600.00 Public Infrastructure Inspection Fee if applicable. (This fee is payable if construction of a public
waterline,seweriine,sidewalk,street or drainage facilities is involved.)
- Fourteen(14)folded copies of site plan
✓ One(1)folded copy of the landscape plan. •
— Non-Residential Architectural Standards Application and associate documents(it applicable)
-- Traffic Impact Analysis(if applicable for non-residential buildings).
✓ A copy of the attached site plan checklist with all items checked off or a brief explanation as to why they
are not checked off.
Parkland Dedication requirement approved by the Parks & Recreation Board, please provide proof of
approval(if applicable).
Date of Preapplication Conference:
NAME OF PROJECT TEAS I?.01Notte.uSG
ADDRESS I to o f t N1 tt.JE es,Tzi blZ•t'E E ST
LEGAL DESCRIPTION LpT#rto (3+ Dom- Or G _ E ct et-ci -- QrtA E
APPLICANT/PROJECT MANAGER'S INFORMATION(Primary Contact for the Project):
Name E-11 - 4,42, se_4 F+ zR •�
Street Address 3 4l SS-Sa.0 CI tee- est SSE l u= city Ql-t,-Dc?r-e-a 4 c,tlziS IL
State t- Zip Code fo o a o r E-Mail Address ole er E g -, .
Phone Number ' `[-) -1 $E Fax Number g r -].se-
ERTY
PROName S T Yfitt&i U9/ &fit delta f
Street Address �3 �!.I 1 / Aid/ City dL
�✓�
Slate rt., Zip Code - ;pp E-Mail Address
Phone Number Fax Number
ARCHITECT OR ENGINEER'S INFORMATION:
Name -rPa4 N 6-12-1 Lac a - &R eE••i S Q G i SARJ W
Street Address 3 4 SAc.i eR E .. LA....)-6. 5.j E ti o City -1-c c 4-0 4+-RS r IL.
Slate I.-- Zlp Code toes E-Mail Address -P3rre-2^1041,-/-r-..re-cu...,•c�r
Phone Number SR.Li-1 -12 Sr- Fax Number c• -18 X -4 S 3(.,
1 o f 6
OTHER CONTACTS(Please specify type of contact,i.e.project manager,potential buyer,local contact,etc.)
Name
Street Address City
State Zip Code E-Mail Address
Phone Number Fax Number
CURRENT ZONING
PRESENT USE OF PROPERTY illAiMititUt
PROPOSED USE OF PROPERTY dittattaittfrit
VARIANCE(S)REQUESTED AND REASON(S)
#OF PARKING SPACES REQUIRED I of #OF PARKING SPACES PROVIDED f 4�'/
1
MULTI-FAMILY RESIDENTIAL PARKLAND DEDICATION
Total Acreage #of Multi-Family Dwelling Units
Floodplain Acreage X$452=$
Housing Units #of acres In floodplain
#of 1 Bedroom Units #of acres in detention
#of 2 Bedroom Units #of acres in greenways
#of 3 Bedroom Units date dedication approved by Parks Board
#of 4 Bedroom Units COMMERCIAL
FOR 2 BEDROOM UNITS ONLY Total'Acreage Lit 4 2
#Bedrooms= 132 sq.ft. Building Square Feet 6 #6
aci
#Bedrooms 132 sq.ft. Floodplain Acreage —4?--
NOTE: Parkland Dedication fee is due prior to the Issuance of a Building Permit.
The applicant has prepared this appficaiion and certifies that the facts stated herein and exhibits attached
hereto are true and correct_
' � ,31a$
Sig a of Owner,Agent or Applicant Date
2ar6
•
SUPPLEMENTAL DEVELOPMENT PERMIT INFORMATION
Application is hereby made for the following development specific site/waterway alterations:
ACKNOWLEDGMENTS:
I, ,design engineer/owner,hereby adcn• -dge or affirm that
The information and conclusions contained in the above plans and supporting docu • nits comply with the current
requirements of the City of College Station,Texas '- Code,Chapter 13 and its - ociated Drainage Policy and Design
Standards.As a condition of approval of this p= it appNcatlon, I agree to con- '„ct the Improvements proposed in this
application according to these documents an. I e requirements of Chapter 1 . the College Station City Code.
Properly Owner(s) Con+ or
CERTIFICATIONS: (for proposed alteration within designated fibs.. hazard areas.)
certify that a nonresidential structure on or proposed to be on this site
as part of this application is designat=• z, • _ -nt damage - = structure or its contents as a result of flooding from the
100 year storm.
Engineer Date
B.1, 'fy t : the fi ed floor elevation of the lowest floor,including any
basement,of any residential structure,prop•--• as part • this -•• ' ,-on is at or above the base flood elevation
established in the latest Federal Insurance • 'nistratio cod azar+ Study and maps,as amended.
Engineer Date
Cl.. ,certify that a alterations or development cowered by this permit shall
not diminish the flood-carrying =city of the waterway adjoini • or crossing this permitted site and that such alterations
or development are consistent requirements of the City of«.lege Station City Code,Chapter 13 concerning
encroachments of floodways • •of floodway fringes.
Engineer Date
D. I, ,do certify that the proposed alterations do not raise he level of the 100
year flood above el, ation established in the latest Federal Insurance Administration Flood Hazard Study.
Engineer Date
Conditions o comments as part of approval:
In : • • rice with Chapter 13 of the Code of Ordinances of the City of College Station,measures shall be
taken to insure that debris from construction, erosion,and sedimentation shall not be deposited in city streets,
or existing drainage facilities.
All development shall be in accordance with the pians and specifications submitted to and approved by the City Engineer
for the above named project.All of the applicable codes and ordinances of the City of College Station shall apply.
3116
C,11
�`SUBMIT APPUCATION AND THIS
LIST C�Fa:aOFF iWITH 14 FOLDED COPIES
J�` OF SiTE PLAN FOR REVISW
CITY OF COLLEGE STATION Lj\ 'ln
Pi.vrnia Developrou Serried
SITE PLAN MENTS
(ALL CITY ORDINiv CES MUST B EMET)
INCLUDING BUT NOT LIMITED TO THE FOLLOWING:
..�tiii Sheet size-24'x 36"(minimum). Clan
El _ A key map(not necessarily to scale).
O Title block to include:
U--" Name, address,location,and legal description
t Name,address,and telephone num bet of applicant
fl- Name,address, and telephone number of deveioper/owner(if differs from applicant)
G"-- Name,address, and telephone number of architect/engineer (if differs from applicant)
0 Date of submittal
Cr'. Total site area not r o p vt.per -_s1411;14 s l-+
t7 North arrow.
• Scale should be largest standard engineering scale possible on sheet.
Ownership and current zoning of parcel and all abutting parcels.
J/,l The total number of multi-family buildings and units to be constructed on the proposed project
site.
AThe density of dwelling units per acre of the proposed project.
t /
The gross square footage of all buildings and structures and the proposed use of each.If
different uses are to be located in a single building, show the location and size of the uses
within the building. Building separation is a minimum of 15 feetwlo additional fire protection.
Locations of the following on or adjacent to the subject site:
Designate between existi no and proposed
,E11/,'a Phasing. Each phase must be able to stand alone to meet ordinance requirements.
Buildings(Existing and Proposed).
O Setbacks according to UDO,Article 5.
Geography
❑ Water courses.
Cl 100 yr.floodplain and flood"ay (if applicable) on or adjacent to the proposed project site,
Please note if there is none on the site with confirming FEMAIFIRM map number.
— 0 Existing topography(2' max or spot elevations)and other pertinent drainage information.
(If plan has too much information,show drainage on separate sheet.)
D Proposed grading(1'max for proposed or spot elevations)and other pertinent drainage
information. (If pian has too much information, show drainage on separate sheet.)
Streets,Pasting,and Sidewalks
Existing streets and sidewalks(R.O.W.).
Existing Driveways,both opposite and adjacent to the site ac cording to UDO, Section 7.3.
❑ Proposed drives.Minimum drive aisle width according to UDO, Section 7.3
..efts ❑ Indicate proposed driveway throat length according to UDO, Section 7.3.
4of5
-❑ Proposed curb cuts.
• For each proposed curb cut(including driveways,streets, alleys,etc.)locate existing curb
cuts on the same and opposite side of the street to determine separation distances between
existing and proposed curb cuts.
_.. ❑ Proposed curb and pavement detail.
• A 6" raised curb is required around aq edges of all parts of all paved areas without
exception. (To include island, planting areas, access ways, dumpster locations, utility pads,
etc.)Na exception will be made for areas designated as"reserved for future parking".
— U Proposed medians.
-- CI Proposed sidewalks(both public and private). /YIC.t v' k
- CI Proposed pedestrianlbike circulation and facilities for non-residential buildings(UDO, Section
7.9)
❑ Off-Street parking areas with parking spaces drawn,tabulated, and dim ensioned.
• Designate number of parking spaces required by ordinance and provided by proposal.
- 0 Handicap parking spaces.
❑ Parking Islands drawn and dimensioned with square footage calculated according to UDO,
Section 7.2 or 7.9 for non-residential buildings.
-- O Parking setback from R.Q.W.to curb of parking lot as required.
Cl Wheelstops may be required when cars overhang onto property not owned by the applicant or
where there may be conflict with pedestrian or bike facilities, handicap accessible routes or
above ground utilities,signs or other conflicts.
. ��a-Security gates, showing swing path and design specs with colors.
Cl Guardraiis.Include design and colors.
Cl Traffic impact Analysis for non-residential development(UDO,Section 7.9)
o Please note if none is required.
— O Will there be access from a TxDOT R.O.W.? Yes 0 No 0
If yes,then TxDOT permit must be submitted with this application.
Easements and Utilities
'D- Easements-clearly designate as existing or proposed and type (utility, access,etc.)
Or.- Utilities(noting size and designate as existing or proposed)within or adjacent to the proposed
site,including building transformer locations, above ground and underground service
connections to buildings, and drainage inlets.
- Cl Water Design Report andfor Fire Flow Report(if applicable)
— t3 Sewer Design Report(if applicable)
O Drainage Report with a Technical Design Summary.
Cl Meter locations, existing and proposed(must be located in public R.O.W.or public utility
easement).
O Provide a water and sanitary sewer legend to include
o Minimum water demands
o Maximum water demands
o Average water demands in gallons per minute,and
o Maximum sewer loadings in gallons per day
O Will there be any utilities in TxDOT R.O.W.? Yes 0 No O
If yes, then TxDOT permit must be submitted with this application.
�kt -- cX 2 c&c�rK 0'02(5
Soft
X �� ies S( 3<fe
1�
weledie -cc- hoe Tcx( � t/-(a,v
Fire Protection
--- ❑ 'Show fire lanes.Fire lanes with a minimum of 20 feet in width with a minimum height clearance
of 14 feet must be established If any portion of the proposed structure is more than 150 feet
from the curb line or pavement edge of a public street or highway.
-- ❑ Show proposed and existing fire hydrants.Fire hydrants must be located on the same side of a
4 1 major street as a project,and shall be in a location approved by the City Engineer.Any structure
in any zoning district other than R-1,R-1A, or R-2 must be within 300 feet of a fire hydrant as
/-� measured along a public street,highway or designated fire lane.
NOTE:Fire hydrants must be operable and accepted by the City, and drives must have an all
weather surface before a building permit can be issued.
-- D
Will building be sprinkled? Yes LI No 0
If the decision to sprinkle is made after the site plan has been approved,then the plan must be
resubmitted.
❑ If Yes, Show fire department connections. F DC's should be within 150 of the fire hydrant. In
no case shall they be any further than 300'apart, and they shall be accessible from the parking
lot without being blocked by parked cars or a structure.
Landscaping
❑ Landscape plans as required in Section 7.5 or 7.9 of the Unified Development Ordinance. The
landscaping plan can be shown on a separate sheet if too much information is on the original
site plan. If requesting protected tree points, then those trees need to be shown appropriately
barricaded on the landscape plan. Attempt to reduce or eliminate plantings in easements.
Include information on the plans such as:
k'\(}) *' trite required point calculationsf
�,� [i1 additional streetscape points required.Streetscape compliance is required on all streets.
�� l calculations for#of street trees required and proposed(proposed street tree points will
� accrue toward total landscaping points.)
it,Q; ,�w GT proposed new plantings with points earned
t3 f proposed locations of new plantings
„r t Q screening of parking lots,50%of all shrubs used for screening shall be evergreen.
(t' Qa r 0 screening of dum psters,concrete retaining walls, off street loading areas,utility
r211 connection points,or other areas potentially visually offensive.
I
I '}'� ❑0,- existing landscaping to remain
F show existing trees to be barricaded and barricade plan_ Protected points will only be
awarded if barricades are up before the first development permit is issued.
CIA44 Buffer as required In Section 7.6 of the Unified Development Ordinance.
O� Show irrigation system plan. (or provide note on how irrigation system requirement will be met
prior to issuance of C.O.) All plans must include irrigation systems for landscaping. Irrigation
meters are separate from the regular water systems for buildings and will be sized by city
according to irrigation demand submitted by applicant and must include backflow prevention
protection.
❑ Is there any landscaping in TxDOT R.Q.W.? Yes Cl No 0
If yes,then TxDOT permit must be submitted at the time of application.
Other
Common open spaces sites
❑ Loading docks
0' Detention ponds
/Er Retaining walls
---. ❑ Sites for solid waste containers with screening.Locations of dumpsters are accessible but not
14,6,ei visible from streets or residential areas.Gates are discouraged and visual screening is required.
(Minimum 12 x 12 pad required.)
❑ Are there impact fees associated with this development? Yes ❑ No D
NOTE: Signs are to be permitted separately.
i1 U i n+s P no.,- clol. plant)-
sorb riMv�t S i,
un(Ler-co.,ttled pk4n-