Loading...
HomeMy WebLinkAboutApplication (11Alei1414 FOR OFFIC USE 0 Y P&Z CASE NO: CITY OF COLLEGE STATION DATE SUBMITTED: iVip Planning cr Development Services PRELIMINARY PLAT APPLICATION The following items must be submitted by an established filing deadline date for P &Z Commission consideration. MINIMUM SUBMITTAL REQUIREMENTS: $400 Filing Fee $100 Variance Request to Subdivision Regulations (if applicable) V Application completed in full. v Fourteen (14) folded copies of plat. (A revised mylar original must be submitted after staff review.) A copy of the attached checklist with all items checked off or a brief explanation as to why they are not. Rezoning Application if zone change is proposed. Parkland Dedication requirement approved by the Parks & Recreation Board, please provide proof of approval (if applicable). Date of Preapplication Conference: February 13, 2008 NAME OF SUBDIVISION: NAVARRO WEST CENTER SPECIFIED LOCATION OF PROPOSED SUBDIVISION: Intersection of Northeast Right-Of-Way of F.M. 2154 and the Northwest Right-of-Way of Navarro Drive. `� p�, t'► o, 1St{ APPLICANT/PROJECT MANAGER'S INFORMATION (Primary Contact for the Project): Name: Hovis Surveying Company Street Address: 5000 Cabbage St City: Spring State: Texas Zip Code: 77379 E-Mail Address: hovis@hovissurveying.com Phone Number: 281-793-7951 Fax Number: 281-376-1726 PROPERTY OWNER'S INFORMATION (ALL owners must be identified. Please attach an additional sheet for multiple owners): Name: WELLBORN CS PLAZA, LTD. Street Address: 7507 Highmeadow City: Houston State: Texas Zip Code: 77063 E-Mail Address Phone Number: 713-783-5052 Fax Number ARCHITECT OR ENGINEER'S INFORMATION: Name: Michael A. Kravetz Street Address: 1111 North Loop West, Suite 800 City: Houston State: Texas Zip Code: 77008 E-Mail Address: Michael.Kravetz@hva.cc Phone Number: 713-869-1103 Fax Number: 713-869-5573 Total Acres Of Subdivision: 2.0849 R-O-W Acreage: 0 Total# Of Lots: 0 Number Of Lots By Zoning District 2_ / C2_ Average Acreage Of Each Residential Lot By Zoning District: Floodplain Acreage: 0 Parkland dedication by acreage or fee? 0 A statement addressing any differences between the Preliminary Plat and approved Master Plan (if applicable) NA Requested variances to subdivision regulations & reason for same NA Requested oversize participation NA Parkland Dedication due prior to filing the Final Plat: ACREAGE: #of Acres to be dedicated #of acres in floodplain #of acres in detention #of acres in greenways OR FEE IN LIEU OF LAND: #of Single-Family Dwelling Units X $556 =$ (date)Approved by Parks & Recreation Board The applicant has prepared this application and certifies that the facts stated herein and exhibits attached hereto are true and correct. The undersigned hereby requests approval by the City of College Station of the above identified plat and attests that all respective owners have been identified on this application. ....7/7/,2-if?..6- Signature and Title Date (irffi" SUBMIT APPLICATION AND THIS CITY OF COLLEGE STATION LIST CHECKED OFF WITH 13 Planningd.Development&rvtces FOLDED COPIES OF PLAT FOR REVIEW PRELIMINARY PLAT MINIMUM REQUIREMENTS (ALL CITY ORDINANCES MUST BE MET) INCLUDING BUT NOT LIMITED TO THE FOLLOWING: 0 14 1. Mylar original of approved master plan (Mylar must be on file or submitted before the preliminary plat will be reviewed). 0 2. Drawn on 24" x 36" sheet to scale of 100' per inch or larger. Include the words "PRELIMINARY PLAT - NOT FOR RECORD" in letters 1/2" high. If more than 1 sheet, an index sheet showing entire subdivision at a scale of 500 feet per inch or larger. 73. Vicinity map which includes enough of surrounding area to show general location of subject property in rel tionship College Station and its City Limits. No scale required but include north arrow.SW 7 © ! Title Block with the following information: Name and address of subdivider, recorded owner, planner, engineer and surveyor. 1 Proposed name of subdivision. (Subdivision name & street names will be approved through Brazos County 911.) (Replats need to retain original subdivision name.) [ ' Date of preparation. (INCLUDE DATE THE PLAT WAS SUBMITTED AND THE r/ DATES OF ANY REVISIONS ON THE PLAT) ver Engineer's scale in feet. Or Total area intended to be developed. [ LX North Arrow. © Location of current city limit lines and current zoning district boundary. D Subdivision boundary indicated by heavy lines. Boundary must include al of parent tract. 13 'B. Descriptions by metes and bounds of the subdivision which shall close within accepted land survey standards. (Labeled on boundary lines, not separate metes and bounds description.) LIE' i Primary control points or descriptions and ties to such control point, to which , later, all dimensions, angles, bearings, block numbers, and similar data shall be referred. The plat shall be located with respect to a corner of the survey or tract, or an original corner of the original survey of which it is a part. a ae Name of contiguous subdivisions and names of owners of contiguous parcels of unsubdivided land, and an indication whether or not contiguous properties are platted. ato . Location of the 100 Year Floodplain and Floodway,dway, if applicable, according to the most recent available data. El 12. Topographic information, including contours at two foot (2 ft.) intervals, wooded areas, and flowline elevation of streams. ❑ 0.33Proposed land uses (In compliance with Land Use Plan). ❑ I./ri1r4�Proposed zoning changes, if any, submit formal rezoning request. [2f 15. The location and description with accurate dimensions, bearings or deflection angles and radii, area, center angle, degree of curvature, tangent distance and length of all curves for all of the following: (Show existing items that are intersecting or contiguous with the boundary of or forming a boundary with the subdivision, as well as, those within the subdivision). Existing Proposed ❑ ❑ Streets. Continuous or end in a cul-de-sac, stubbed out streets must end into a temp. turn around unless they are shorter than 100 feet. IA ❑ Public and private R.O.W. locations and widths. (All existing and proposed R.O.W.'s sufficient to meet Thoroughfare Plan.) ❑ El Street offsets and/or intersection angles meet ordinance. • ❑ Alleys. ❑ Reserve tracts. • ❑ Well site locations. El ❑ Pipelines. If carrying flammable gas or fuel, also show size of line, design pressure and product transported through the line. ❑ Utility Services. (Water& Sanitary Sewer) All existing and proposed utilities of sufficient size/depth to meet the utility master plan and any future growth areas. 12 ❑ Easements. ❑ ❑ Drainage Structures and improvements including underground storm sewer and all overland systems (flow line of existing watercourses) and showing where these will discharge. Proposed channel cross sections, if any. [2 ❑ A number or letter to identify each lot or site and each block. El El Greenbelt area/park linkages/parkland dedication (All proposed dedications must be reviewed by the Parks and Recreation Board prior to P & Z Commission consideration.) ❑ ❑ Public areas ❑ ❑ Other public improvements, including but not limited to parks, schools and other public facilities ❑ M16. Proposed phasing. Each phase must be able to stand alone to meet ordinance requirements and infrastructure costs should be distributed evenly throughout the subdivision. ❑ 17. Are there impact fees associated with this development? ❑ Yes [I'No ❑N'18. If requesting oversize participation items, are the necessary impact studies included? ❑Yes ❑No ❑N/A