HomeMy WebLinkAboutStaff Review STAFF REVIEW COMMENTS NO. 1 Project: CRESCENT POINTE PH 2, BLOCK 1 (FP-REPLAT - 07-00500119 PLANNING 1. The plat title should be a replat of lots 1R, 2R, and 3R of Block 1, Crescent Pointe Subdivision. Based on the boundaries of the subdivision, Common Area D is not included in this replat, therefore it is not a replat of the entire block. 2. Remove Volume and Page number from Ownership and Dedication certificate, and title as per previous note. 3. Remove the attest signature by the City Secretary. Plats are no longer attested by the Council office. 4. What is the volume and page number of the telephone easement? 5. The access easement between 6R and 7R should be lined up with the access easement for Phase One, Lots 1 and 3. 6. The access easement between 7R and 8R location will preclude any driveway access to Phase One, Lot 4. Please revise this easement and/or lot line to allow this lot to have room for driveway access. 7. What is the proposed carrier site? 8. Please label all existing easements with volume and page number. 9. Provide a note with the zoning of these lots as well as a reference to the building setbacks in the Unified Development Ordinance. 10. We are considering building plots for this replat. Do you have a proposal of lots that will have similar uses and share access that might work as a building plot? 11. Please note that any changes made to the plans, that have not been requested by the City of College Station, must be explained in your next transmittal letter and "bubbled" on your plans. Any additional changes on these plans that the City has not been made aware of will constitute a completely new review. 12. The construction documents, reports and final plat are still under review by engineering and may affect the plat. Reviewed by: Lindsay Boyer Date: May 24, 2007 ELECTRICAL COMMENTS REQUIRING IMMEDIATE ATTENTION 1. Developer provides temporary blanket easement for construction purposes. 2. Developer provides easements for electric infrastructure as installed for electric lines (including street lights). GENERAL ELECTRICAL COMMENTS 1. Developer installs conduit per City specs and design. 2. City will provide drawings for conduit installation. 3. Developer provides 30' of rigid or IMC conduit for riser poles. City installs riser. 4. Developer to intercept existing conduit at designated transformers and extend as required. 5. If conduit does not exist at designated transformer, developer to furnish and install conduit as shown on electrical layout. 6. Developer pours transformer pad(s) per City specs and design. 7. Developer installs pull boxes and as per City specs and design (pull boxes provided by the City). 8. Developer provides digital AutoCAD 2000 or later version of plat and/or site plan. Email to: sweido@cstx.gov. NOTE: Any changes made to the plans, that have not been requested by the City of College Station, must be explained in your next transmittal letter and "bubbled" on your plans. Any additional changes on these plans that have not been pointed out to the City,will constitute a completely new review. 2 of 3 9. Developer provides load data for project. 10. To discuss any of the above electrical comments please contact Sam Weido at 979.764.6314. Reviewed by: Sam Weido Date: 5-24-07 SANITATION 1. Sanitation is ok with this project. Reviewed by: Wally Urrutia Date: May 25, 2007 NOTE: Any changes made to the plans, that have not been requested by the City of College Station, must be explained in your next transmittal letter and "bubbled" on your plans. Any additional changes on these plans that have not been pointed out to the City,will constitute a completely new review. 3 of 3