Loading...
HomeMy WebLinkAboutApplication ‘ff go FOR OFFICE USE ONLY i P&Z CASE NO.: ( 1 J 9" --COY DATE SUBMITTED: CITY OF COLLEGE STATION Planning ear Development Services SITE PLAN APPLICATION 46p. MINIMUM SUBMITTAL REQUIREMENTS X Site plan application completed in full. X $200.00 Application Fee. X $200.00 Development Permit Application Fee. N/A $600.00 Public Infrastructure Inspection Fee if applicable. (This fee is payable if construction of a public waterline, sewerline, sidewalk, street or drainage facilities is involved.) X _Fourteen (14) folded copies of site plan X One (1) folded copy of the landscape plan. N/A One (1) copy of building elevation for all buildings. N/A A list of building materials for all facades and screening for non-residential buildings. N/A Color samples for all non-residential buildings. N/A Traffic Impact Analysis (if applicable for non-residential buildings). X A copy of the attached site plan checklist with all items checked off or a brief explanation as to why they are not checked off. N/A Parkland Dedication requirement approved by the Parks & Recreation Board, please provide proof of approval (if applicable). Date of Preapplication Conference: NAME OF PROJECT TARGET PARKING RENOVATIONS ADDRESS 2100 Texas Avenue South LEGAL DESCRIPTION Lot 4, Block 1 Kapchinski Hill Subdivision APPLICANT/PROJECT MANAGER'S INFORMATION (Primary Contact for the Project): Name Veronica Morgan Street Address 511 University Drive City College Station State Texas zip Code 7784o E-Mail Address v(c�mitchellandmorgan.com Phone Number (979) 260-6963 Fax Number (979) 260-3564 PROPERTY OWNER'S INFORMATION: Name Target c/o Katie Rivard Street Address 1000 Nicollet Mall, TPN-12G City Minneapolis State MN Zip Code 55403 E-Mail Address Katie.Rivard(a�Target.com Phone Number (612) 761-2422 Fax Number (612) 761-3727 ARCHITECT OR ENGINEER'S INFORMATION: Name Veronica Morgan Street Address 511 University Drive City College Station State Texas Zip Code 77845 E-Mail Address v( mitchellandmorgan.com Phone Number (979) 260-6963 Fax Number (979) 260-3564 1 of6 OTHER CONTACTS (Please specify type of contact, i.e. project manager, potential buyer, local contact, etc.) Name Street Address City State Zip Code E-Mail Address Phone Number Fax Number CURRENT ZONING C-1 PRESENT USE OF PROPERTY retail PROPOSED USE OF PROPERTY retail VARIANCE(S) REQUESTED AND REASON(S) no end island, no interior islands along Texas in an effort to maximize parking # OF PARKING SPACES REQUIRED N/A # OF PARKING SPACES PROVIDED N/A We are reconfiguring the parking lot as a result of the TXDOT widening project MULTI-FAMILY RESIDENTIAL PARKLAND DEDICATION Total Acreage N/A # of Multi-Family Dwelling Units Floodplain Acreage N/A N/A X $452 = $ N/A Housing Units N/A N/A # of acres in floodplain N/A # of 1 Bedroom Units N/A # of acres in detention N/A # of 2 Bedroom Units N/A # of acres in greenways N/A # of 3 Bedroom Units N/A date dedication approved by Parks Board N/A # of 4 Bedroom Units COMMERCIAL FOR 2 BEDROOM UNITS ONLY Total Acreage N/A N/A # Bedrooms = 132 sq. ft. Building Square Feet N/A N/A # Bedrooms < 132 sq. ft. Floodplain Acreage 0 NOTE: Parkland Dedication fee is due prior to the issuance of a Building Permit. The applicant has prepared this application and certifies that the facts stated herein and exhibits attached heret re true and correct. r r I Signature of Ow :1 , Ag s t r Applicant Date I 2 of 6 lick __I-Tait,C4- 1 ,,,C+ '' ilturt\-11LC) -) SUPPLEMENTAL DEVELOPMENT PERMIT INFORMATION Application is hereby made for the following development specific site/waterway alterations: ACKNOWLEDGMENTS: I, V V� � V`J , design engineer/owner, hereby acknowledge or affirm that: The information and concl ions contained in the above plans and supporting documents comply with the current requfinents of the City of College Station, Texas City Code, Chapter 13 and its associated Drainage Policy and Design Star�gdbrds. As a condition of approval of thi ``��fatwtion, I agree to construct the improvements proposed in this app":tion accor•ing o these document,he'r rtuifbpts of Chapter 13 of the College Station City Code. Ir---- Property Ownerfa) i VERONICA J.B.MORGAN Contractor l-o'•, 77689 ;•'� CERTIFICATIONS: (for proposed alter�4io .v9lt in oivt eg flood hazard areas.) A.I, lOUtLl1 J� y ���f ''i�tisk- liat any nonresidential structure on or proposed to be on this site N. as pir of this application is designated to prevent damage to the structure or its contents as a result of flooding from the 100 ar storm. 1N 41 c\--.) -41(z40-/- Engineer Date B. I, A certify that the finished floor elevation of the lowest floor, including any basement, of any residential structure, proposed as part of this application is at or above the base flood elevation established in the latest Federal Insurance Administration Flood Hazard Study and maps, as amended. Engineer i Date C. I, MIJ , certify that the alterations or development covered by this permit shall not diminish the flood-carrying capacity of the waterway adjoining or crossing this permitted site and that such alterations or development are consistent with requirements of the City of College Station City Code, Chapter 13 concerning encroachments of floodways and of floodway fringes. Engineer Date D. I, Iv IA Q, , do certify that the proposed alterations do not raise the level of the 100 year flood above elevation established in the latest Federal Insurance Administration Flood Hazard Study. Engineer Date Conditions or comments as part of approval: In accordance with Chapter 13 of the Code of Ordinances of the City of College Station, measures shall be taken to insure that debris from construction, erosion, and sedimentation shall not be deposited in city streets, or existing drainage facilities. All development shall be in accordance with the plans and specifications submitted to and approved by the City Engineer for the above named project. All of the applicable codes and ordinances of the City of College Station shall apply. 3 of 6 SUBMIT APPLICATION AND THIS t LIST CHECKED OFF WITH 14 FOLDED COPIES (1111*11(11511111111111 j t- OF SITE PLAN FOR REVIEW CITY OF COLLEGE STATION Planning&Development Services SITE PLAN MINIMUM REQUIREMENTS (ALL CITY ORDINANCES MUST BE MET) INCLUDING BUT NOT LIMITED TO THE FOLLOWING: Sheet size - 24" x 36" (minimum). A key map (not necessarily to scale). ® Title block to include: 4o Name, address, location, and legal description Name, address, and telephone number of applicant /e` Name, address, and telephone number of developer/owner (if differs from applicant) Name, address, and telephone number of architect/engineer (if differs from applicant) J ® Date of submittal l Total site area North arrow. /.lid Scale should be largest standard engineering scale possible on sheet. $ I'ffi Ownership and current zoning of parcel and all abutting parcels. + 1`9 The total number of multi-family buildings and units to be constructed on the proposed project site. # 16 The density of dwelling units per acre of the proposed project. -N The gross square footage of all buildings and structures and the proposed use of each. If different uses are to be located in a single building, show the location and size of the uses within the building. Building separation is a minimum of 15 feet w/o additional fire protection. Locations of the following on or adjacent to the subject site: Designate between existing and proposed NW Phasing. Each phase must be able to stand alone to meet ordinance requirements. Buildings (Existing and Proposed). titit Setbacks according to UDO, Article 5. ' coi Building elevations, color samples, and materials list for non-residential buildings. Indicate placement of materials on facades according to UDO, Section 7.9. o Include the following dimensions: • Total vertical square footage minus openings (for each façade separately) • Total vertical square footage of each building material (for each façade separately) • Total vertical square footage of each color (for each façade separately) Geography q '+ Water courses. 100 yr. floodplain and floodway (if applicable) on or adjacent to the proposed project site, Please note if there is none on the site with confirming FEMA/FIRM map number. qit Existing topography (2' max or spot elevations) and other pertinent drainage information. (If plan has too much information, show drainage on separate sheet.) Proposed grading (1' max for proposed or spot elevations) and other pertinent drainage information. (If plan has too much information, show drainage on separate sheet.) 4 of 6 Streets, Parking, and Sidewalks la' Existing streets and sidewal R.O. ). 1C9` Existing Driveways, both oppo I e a adjacent to the site according to UDO, Section 7.3. + t4ch Proposed drives. Minimum drive aisle width according to UDO, Section 7.3 * Indicate proposed driveway throat length according to UDO, Section 7.3. tP Proposed curb cuts. • For each proposed curb cut (including driveways, streets, alleys, etc.) locate existing curb cuts on the same and opposite side of the street to determine separation distances between existing and proposed curb cuts. / L '' Proposed curb and pavement detail. • A 6" raised curb is required around all edges of all parts of all paved areas without exception. (To include island, planting areas, access ways, dumpster locations, utility pads, etc.) No exception will be made for areas designated as "reserved for future parking". k ' IIS Proposed medians. ilia Proposed sidewalks (both public and private). +..}. Nil Proposed pedestrian/bike circulation and facilities for non-residential buildings (UDO, Section 7.9) ''j D' Off-Street parking areas with parking spaces drawn, tabulated, and dimensioned. • Designate number of parking spaces required by ordinance and provided by proposal. y 0/14 Handicap parking spaces. +jlid) Parking Islands drawn and dimensioned with square footage calculated according to UDO, Section 7.2 or 7.9 for non-residential buildings. at' Parking setback from R.O.W. to curb of parking lot as required. NFA Wheelstops may be required when cars overhang onto property not owned by the applicant or where there may be conflict with pedestrian or bike facilities, handicap accessible routes or above ground utilities, signs or other conflicts. Nta Security gates, showing swing path and design specs with colors. Opt Guardrails. Include design and colors. og Traffic Impact Analysis for non-residential development (UDO, Section 7.9) o Please note if none is required. I " Will there be access from a TxDOT R.O.W.? Yes ❑ No L y If yes, then TxDOT permit must be submitted with this application. Easements and Utilities L Easements - clearly designate as existing or proposed and type (utility, access, etc.) OR Utilities (noting size and designate as existing or proposed) within or adjacent to the proposed site, including building transformer locations, above ground and underground service connections to buildings, and drainage inlets. IJOs Water Design Report and/or Fire Flow Report (if applicable) NI} Sewer Design Report (if applicable) kg Drainage Report with a Technical Design Summary. jv Meter locations, existing and proposed (must be located in public R.O.W. or public utility easement). Nri Provide a water and sanitary sewer legend to include o Minimum water demands o Maximum water demands o Average water demands in gallons per minute, and o Maximum sewer loadings in gallons per day i3'' Will there be any utilities in TxDOT R.O.W.? Yes ❑ No ❑- If yes, then TxDOT permit must be submitted with this application. 5 of 6 Fire Protect4n Show fire lanes. Fire lanes with a minimum of 20 feet in width with a minimum height clearance of 14 feet must be established if any portion of the proposed structure is more than 150 feet from the curb line or pavement edge of a public street or highway. kqP Show proposed and existing fire hydrants. Fire hydrants must be located on the same side of a major street as a project, and shall be in a location approved by the City Engineer. Any structure in any zoning district other than R-1, R-1A, or R-2 must be within 300 feet of a fire hydrant as measured along a public street, highway or designated fire lane. NOTE: Fire hydrants must be operable and accepted by the City, and drives must have an all weather surface before a building permit can be issued. Will building be sprinkled? Yes ❑ No ❑ If the decision to sprinkle is made after the site plan has been approved, then the plan must be resubmitted. ❑ If Yes, Show fire department connections. FDC's should be within 150' of the fire hydrant. In no case shall they be any further than 300' apart, and they shall be accessible from the parking lot without being blocked by parked cars or a structure. Landscaping Er Landscape plans as required in Section 7.5 or 7.9 of the Unified Development Ordinance. The landscaping plan can be shown on a separate sheet if too much information is on the original site plan. If requesting protected tree points, then those trees need to be shown appropriately barricaded on the landscape plan. Attempt to reduce or eliminate plantings in easements. Include information on the plans such as: Ur required point calculations Ur additional streetscape points required. Streetscape compliance is required on all streets. Ca' calculations for# of street trees required and proposed (proposed street tree points will accrue toward total landscaping points.) a' proposed new plantings with points earned L' proposed locations of new plantings screening of parking lots, 50% of all shrubs used for screening shall be evergreen. rf+ screening of dumpsters, concrete retaining walls, off street loading areas, utility connection points, or other areas potentially visually offensive. existing landscaping to remain show existing trees to be barricaded and barricade plan. Protected points will only be awarded if barricades are up before the first development permit is issued. 9:11A Buffer as required in Section 7.6 of the Unified Development Ordinance. --777" Show irrigation system plan. (or provide note on how irrigation system requirement will be met C'A • prior to issuance of C.O.) All plans must include irrigation systems for landscaping. Irrigation (,tom • meters are separate from the regular water systems for buildings and will be sized by city • 4.1 according to irrigation demand submitted by applicant and must include backflow prevention protection. at- Is there any landscaping in TxDOT R.O.W.? Yes ❑ No Cid'' If yes, then TxDOT permit must be submitted at the time of application. Other Common open spaces sites 44L), Loading docks 143k Detention ponds Retaining walls 9A Sites for solid waste containers with screening. Locations of dumpsters are accessible but not I visible from streets or residential areas. Gates are discouraged and visual screening is required. (Minimum 12 x 12 pad required.) El Are there impact fees associated with this development? Yes ❑ No E NOTE: Signs are to be permitted separately. 6 of 6