HomeMy WebLinkAboutDrawings Doux Chene Apartments A&M Shuttle Bus Stop #1
2101 Harvey Mitchell Pkwy S Located on Southwood Drive
College Station, TX 77840 Scale: 3/8" = 1' 0"
Proposed Improvement- Side View
60"
52 .71
416 16 1 �8' l "
9. "
80 "
120"
I
T
Southwood Doux Chene
Valley Dr. l Apartments
Parking Lot
12"
ROW Encroachment
Doux Chene Apartments A&M Shuttle Bus Stop #1
2101 Harvey Mitchell Pkwy S Located on Southwood Drive
College Station, TX 77840 Scale: 3/8" = 1' 0"
Location of 8" water main in relation to
proposed improvement- Side View
— 60 " —
/ \
— 120 "
Southwood Doux Chene
Valley Dr. — Apartments
Parking Lot
20 "
(L)r...._
52 "
84 " -
Doux Chene Apartments A&M Shuttle Bus Stop #1
2101 Harvey Mitchell Pkwy S Located on Southwood Drive
College Station, TX 77840 Scale: 3/8" = 1' 0"
Proposed Improvement- Top View
ROW Encroachment
712,E
Bus Stop Sign
(Existing)
• 168"
108 " 60"
32 "
Q ► 120" y c
127"
v a:
60
0
vI
0
1
Doux Chene Apartments A&M Shuttle Bus Stop #1
2101 Harvey Mitchell Pkwy S Located on Southwood Drive
College Station, TX 77840 Scale: 1/4" = 1' 0"
Location of 8" water main in relation to
proposed improvement- Top View
-• 84" ►
f-60"—o—
n
Ca 12'
Q
o Ua
.c o
0
Q
52"
Field Verified 4/17/2007.
Location marked at 84" from back
of Doux Chene parking lot curb.
13'-0"
,4„ 1.-1?)
Doux Chene Apartments A IM Shuttle Bus Stop #1
2101 Harvey Mitchell Pkwy S Located on Southwood Drive
College Station, TX 77840 Scale: 3/8" = 1' 0"
Location of 8" water main in relation to proposed improvement.
72 in
3❑ in _
96 in
Southwood r L I DouxApartments Chene
Valley Dr.
J —
Parking Lot
8."-
718 „
0
84 "
Field Verified 4/17/2007.
Location marked at 84" from back of
Doux Chene parking lot curb.
Doux Chene Apartments A&M Shuttle Bus Stop #1
2101 Harvey Mitchell Pkwy S Located on Southwood Drive
College Station, TX 77840 Scale: 1/4" = 1' 0"
Location of 8" water main in relation to proposed improvement.
Field Verified 4/17/2007.
Location marked at 84" from back of
Doux Chene parking lot curb.
84"
- L18 "
8"
Q � o
u
s o
Q
0
❑
A
13'-0"
94 in
®'
Doux Chene Apartments A&M Shuttle Bus Stop #1
2101 Harvey Mitchell Pkwy S Located on Southwood Drive
College Station, TX 77840 Scale: 3/8" = 1' 0"
Requested design modification:
Columns closest to main relocated
behind ROW, cantilevered support
for roof structure. 72 in
The angled brace at the top of the
post is for aesthetic purposes.
24H "
41,
80 "
120 in �.
Southwood J _ I — L Doux Chene
Valley Dr. Apartments
Parking Lot
8 " _
32 "7
84 "
Doux Chene Apartments A&M Shuttle Bus Stop #1
2101 Harvey Mitchell Pkwy S Located on Southwood Drive
College Station, TX 77840 Scale: 3/8" = 1' 0"
Requested design modification:
Columns closest to main relocated
behind ROW, cantilevered support
for roof structure. 72 in
The angled brace at the top of the
post is for aesthetic purposes.
/--24
X21 " 11 "
80 "
120 in um-
gimir]
Southwood j _ ' - Doux Chene
Apartments
Valley Dr. Parking Lot
8 "
(::: „.,,.__
32 "--7
84 "
itI ani Pr'
Doux Chene Apartments A&M Shuttle Bus Stop #1
2101 Harvey Mitchell Pkwy S Located on Southwood Drive
College Station, TX 77840 Scale: 3/8" = 1' 0"
Proposed design modification:
Column nearest main provides
primary support for canopy.
72 "
Second post provides
counter-balance to offset
load of canopy.
40 "
Clearance from main is 48".
Column is set 16" behind ROW.
80 "
Doux Chene
Southwood Apartments
Valley Dr. 120 "
Parking Lot
8 "
48 " _
0
84 "
l'fl �..
Doux Chene Apartments A&M Shuttle Bus Stop #1
2101 Harvey Mitchell Pkwy S Located on Southwood Drive
College Station, TX 77840 Scale: 3/8" = 1' 0"
Proposed design modification:
Column nearest main provides
primary support for canopy.
72 "
Second post provides
counter-balance to offset
load of canopy.
Clearance from main is 48".
Column is set 16" behind ROW.
1
80 "
Doux Chene
Southwood J - Apartments
Valley Dr. 120 Parking Lot
8. "
48
"
O
84 "