Loading...
HomeMy WebLinkAboutStaff Comments,TJ 1:11►yi[01 711M7i1T July 23, 2007 TO: Alton Ofczarzsk, via email liz@oakchb.com FROM: Lindsay Boyer, AICP, Senior Planner SUBJECT: FLETCHER TRACT (REZ) — Rezoning Staff reviewed the above-mentioned rezoning as requested. The following page is a list of staff review comments detailing items that need to be addressed. Please address all comments and submit the following information by Monday, July 30th, 10:00 a.m., for your project to be placed on the next available Planning & Zoning Commission (P&Z) meeting scheduled for August 16th, 7:00 p.m. in the City Hall Council Chambers, 1101 Texas Avenue: One (1) 24"x36" copy of the revised Rezoning Map; Eighteen (18) 11"x17" copies of the revised Rezoning Map; One (1) copy of the revised Metes and Bounds; One (1) copy of the digital file of the revised rezoning Metes & Bounds on diskette or e-mail to Iboyer@cstx.gov. Please note that if all comments have not been addressed, your project will be not be scheduled for the P&Z agenda. Your project may be placed on a future agenda once all comments have been addressed and the appropriate re -advertising fees paid. Once your item has been scheduled for the P&Z meeting, the agenda and staff report can be accessed at the following web site on Monday the week of the P&Z meeting. http://www.cstx.gov/home/index.asp?page=2481 If you have any questions or need additional information, please call me at 979.764.3570. Attachments: Staff Review Comments PC: Mike Hester, via email mhester@hester-engr.com Case file #07-00500169 NOTE: Any changes made to the plans, that have not been requested by the City of College Station, must be explained in your next transmittal letter and "bubbled" on your plans. Any additional changes on these plans that have not been pointed out to the City, will constitute a completely new review. 1 of 2 STAFF REVIEW COMMENTS NO. 1 Project: FLETCHER TRACT (REZ) — (07-00500169) PLANNING 1. Rezoning boundary does not close. Please review and revise calls as necessary. 2. Identify Existing and Proposed Zoning on the Rezoning Map. 3. A portion of the property along the eastern edge is identified as Floodplain and Streams on the City's Comprehensive Plan. Areas within the floodplain should be removed from the rezoning in accordance with the Comprehensive Plan. Staff will not support rezoning in these areas. 4. Have you been in contact with the neighborhoods in this area as encouraged by staff? 5. Have you given any additional thought to a PDD zone? The process has recently changed to require a concept plan with the rezoning, however there is no additional review by the Design Review Board if the rezoning is approved. Reviewed by: Lindsay Boyer, Project Manager Date: July 20, 2007 ENGINEERING COMMENTS NO. 1 1. Please label the 20 -ft Sanitary Sewer Easement as it projects across the property and makes jog near Emerald Parkway. 2. Please label the 20 -ft PUE (electrical easement) that parallels the existing 20 -ft PUE at the rear of the lot of Phase 7 of Emerald Forest. 3. The PUE at the rear of the Sandstone Addition appear to be 16 -ft not 20 -ft, please verify. 4. Please label the specific floodplain designation at it appears on FEMA FIRM Panel 163C. Reviewed by: Josh Norton Date: July 19, 2007 NOTE: Any changes made to the plans, that have not been requested by the City of College Station, must be explained in your next transmittal letter and "bubbled" on your plans. Any additional changes on these plans that have not been pointed out to the City, will constitute a completely new review. 2 of 2