Loading...
HomeMy WebLinkAboutCorrespondence rOP* CITY OF COLLEGE STATION Planning t4'Development Services 1101 Texas Avenue, PO Box 9960 College Station, Texas 77842 Phone 979.764.3570 / Fax 979.764.3496 April 9, 2007 RE: Variance Case 07-00500050 —410 Holleman Dear Ms. Ruiz: The Zoning Board of Adjustments voted (5-0) to grant the variance for the height requirement for the above-referenced case. This vote was taken at the Board's regular meeting on April 3, 2007 For further information, please contact me at 979.764.3784. •• erel 1 __ -••rah Grace Staff Assistant Secretary to the Board PC: File Sent via e-mail March 19,2007 Jason Schubert,Staff Planner City of College Station 1101 Texas Avenue South College Station,Texas 77842 Re: Height variance request at 410 Holleman Drive in the Wolf Pen Creek district. Dear Jason: The purpose of this letter is to respond to your staff review comments dated March 12, 2007. I offer the following information per your request to further clarify our application for a height variance: (1) The elevation at the rear property line. RESPONSE: The elevation at the rear property line adjacent to the single family homes ranges from 278' to 284'. (2) The ground elevation of the proposed parking garage at the point nearest the rear property line. RESPONSE: We're working on a finished floor range of 272' —273'. (3) The true height of the proposed parking garage. RESPONSE: The height of the parking garage is 56 feet. The garage is 5 stories in height (6 levels) and will provide direct access to residents living on floors 1 thru 4. The apartments will all contain 10' ceilings therefore the corresponding height of each garage level is as follows: Level 6: 3' 0" Level 5: 9' 0" Level 4: 9' 0" Level3: 11' 8" Level 2: 11' 8" Level 1: 11' 8" (4) A conceptual site plan showing the location of the parking garage and other structures. RESPONSE: A conceptual site plan is attached. In summary, we are requesting a garage height of 44' to 51' above the elevation of the rear property line resulting in a 4' to 11' height variance or a 8' to 22' setback variance. This letter should clarify all outstanding issues and keep us on schedule for the Zoning Board of Adjustment meeting on April 3, 2007. Please do not hesitate to call me at(979) 846-9259 if you have any questions. Sincerely, Otacifiz Natalie Ruiz,AICP Principal Attachments: Concept Plan (*ff111111111 ,9ja•9 Hxu d1sh CITY OF COLLEGE STATION Planning d Development services " ., .. id0b9ppgN' 1101 Texas Avenue,P.O. Box 9960 College Station,Texas 77842 Phone 979.764.3570 / Fax 979.764.3496 MEMORANDUM March 12,2007 TO: Natalie Ruiz,IPS Group—Planning Solutions,via Natalie(auiipsgroup.us FROM: Jason Schubert,Staff Planner SUBJECT: 410 HOLLEMAN DRIVE (VAR) Staff reviewed the above-mentioned application as requested. Please submit the following information by Monday,March 19th, 10:00 am for further staff review: 1) The elevation at the rear property line. 2) The ground elevation of the proposed parking garage at the point nearest the rear property line. 3) The true height of the proposed parking garage. 4) A conceptual site plan showing location of parking garage and other structures. If the additional information is provided, the item will be scheduled for the April 3rd Zoning Board of Adjustment (ZBA) meeting. If you have any questions or need additional information,please call me at 979.764.3570. cc: Bill Mather,Grid Commercial Real Estate,owner,via billmagridre.com Mark Lindley,Assest Plus Corporation,via mlindleyassetpluscorp.com Case file#07-00500050 Home of Texas A&M University