HomeMy WebLinkAboutApplication FOR OFFIC 0 Y�
--N)SI ' 1382 CASE NO.: � I
—trffS" S DATE SUBMITTED:
CITY OF COLLEGE STATION g . " 7
Planning&Development Services ,
FINAL PLAT APPLICATION
(Check one) ❑ Minor 1E1 Amending ® Final
El Vacating ❑ Replat
($300.00) ($300.00) ($400.00) ($400.00) ($600.00)*
*Includes public hearing fee
Is this plat in the ETJ? ❑ Yes ( j No
The following items must be submitted by an established filing deadline date for P8Z Commission
consideration.
MINIMUM SUBMITTAL REQUIREMENTS:
X $300 - $600 Filing Fee (see above) NOTE: Multiple Sheets - $55.00 per additional sheet
N/A $100 Variance Request to Subdivision Regulations (if applicable)
X $200 Development Permit Application Fee (if applicable).
X $600.00 Infrastructure Inspection Fee (applicable if any public infrastructure is being constructed)
X Application completed in full.
N/A Copy of original deed restrictions/covenants for replats (if applicable). ,
X Fourteen (14) folded copies of plat. (A signed mylar original must be submitted after staff review.)
X Paid tax certificates from City of College Station, Brazos County and College Station I.S.D.
X A copy of the attached checklist with all items checked off or a brief explanation as to why they are not.
X Two (2) copies of public infrastructure plans associated with this plat (if applicable).
N/A Parkland Dedication requirement approved by the Parks & Recreation Board, please provide proof of
approval (if applicable).
Date of Preapplication Conference: June 21, 2006
NAME OF SUBDIVISION SONOMA SUBDIVISION
SPECIFIED LOCATION OF PROPOSED SUBDIVISION (Lot& Block) 2755 Barron Road
APPLICANT/PROJECT MANAGER'S INFORMATION (Primary Contact for the Project):
Name BCS Development Company; Contact Name: Mr. Randy French
Street Address 4090 SH 6 South City College Station
State Texas Zip Code 77845 E-Mail Address rfrenchastylecraft-builders.com
Phone Number (979) 690-1222 Fax Number (979) 690-0348
PROPERTY OWNER'S INFORMATION (ALL owners must be identified. Please attach an additional sheet for multiple
owners):
Name Same as above
ARCHITECT OR ENGINEER'S INFORMATION:
Name McClure & Browne Engineering/Surveying, Inc.
Street Address 1008 Woodcreek Drive City College Station
State Texas Zip Code 77845 E-Mail Address DaleB@_McClureBrowne.com
Phone Number (979) 693-3838 Fax Number(979) 693-2554
Do any deed restrictions or covenants exist for this property? Yes No X
Is there a temporary blanket easement on this property? If so, please provide the Volume and Page#
Acreage–Total Property 8.53 acres Total#of Lots 29 R-O-W Acreage 2.30 acres
Existing Use: Agriculture Proposed Use: Residential
Number of Lots By Zoning District 29 / R-1
Average Acreage Of Each Residential Lot By Zoning District: 0.163 / R-1
Floodplain Acreage -0-
A statement addressing any differences between the Final Plat and approved Master Plan and/or Preliminary Plat (if
applicable):
N/A
Requested Variances To Subdivision Regulations&Reason For Same: N/A
Requested Oversize Participation: N/A
Total Linear Footage of Parkland Dedication due prior to filing the Final Plat:
Proposed Public:
ACREAGE:
1040 Streets # of acres to be dedicated + $ development fee
680 Sidewalks # of acres in floodplain
2790 Sanitary Sewer Lines # of acres in detention
1106 Water Lines # of acres in greenways
-0- Channels OR
870 Storm Sewers FEE IN LIEU OF LAND:
-0- Bike Lanes / Paths # of Single-Family Dwelling Units X$556 =$
(date) Approved by Parks & Recreation Board
NOTE: DIGITAL COPY OF PLAT MUST BE SUBMITTED PRIOR TO FILING.
The applicant has prepared this application and certifies that the facts stated herein and exhibits attached hereto are true,
corr t, and •. plete. N.a undersigned hereby requests approval by the City of College Station of the above-identified
final plat a/, t i is request does not amend any covenants or restrictions associated with this plat.
4
/ ;=..* azo7
Si• V ure and Titl— Date
SUPPLEMENTAL DEVELOPMENT PERMIT INFORMATION
Application is hereby made for the following development specific site/waterway alterations:
ACKNOWLEDGMENTS:
I , design engineer/owner, hereby acknowledge or affirm that:
The information and conclusions contained in the above plans and supporting documents comply with the current
requirements of the City of College Station, Texas City Code, Chapter 13 and its associated Drainage Policy and Design
Standards. As a condition of approval of this permit application, I agree to construct the improvements proposed in this
application according to these documents and the requirements of Chapter 13 of the College Station City Code.
Property Owner(s) Contractor
CERTIFICATIONS: (for proposed alterations within designated flood hazard areas.)
A. I, certify that any nonresidential structure on or proposed to be on this site
as part of this application is designated to prevent damage to the structure or its contents as a result of flooding from the
100 year storm.
Engineer Date
B. I, certify that the finished floor elevation of the lowest floor, including any
basement, of any residential structure, proposed as part of this application is at or above the base flood elevation
established in the latest Federal Insurance Administration Flood Hazard Study and maps, as amended.
Engineer Date .:-"".ss OF TF<��1'+t,
C. I, errgr �� , certify that the alterations or development cover# A this it it'5t� 1't/
not diminish the flood-carrying capacity of the waterway adjoining or crossing this permitted site a ins : � � 4
or development are consistent with requirements of the City of College Station City Code, �h r .•..
encroachments of floodways and of floodway fringes. �i�9� :41./
!07 A'.....</ce• .... N .
Eng��eer Date �>
D. I, , do certify that the proposed alterations do not raise the level of the 100
year flood above elevation established in the latest Federal Insurance Administration Flood Hazard Study.
Engineer Date
Conditions or comments as part of approval:
In accordance with Chapter 13 of the Code of Ordinances of the City of College Station, measures shall be taken to
insure that debris from construction, erosion, and sedimentation shall not be deposited in city streets, or existing drainage
facilities. All development shall be in accordance with the plans and specifications submitted to and approved by the City
Engineer for the above named project. All of the applicable codes and ordinances of the City of College Station shall
apply.
(irffiN411114'
SUBMIT APPLICATION AND THIS
CITY OF COLLEGE STATION LIST CHECKED OFF WITH 13
Planning d Dnxlnpment Siwi«r FOLDED COPIES OF PLAT FOR REVIEW
FINAL PLAT MINIMUM REQUIREMENTS
(ALL CITY ORDINANCES MUST BE MET)
INCLUDING BUT NOT LIMITED TO THE FOLLOWING:
(Requirements based on field survey and marked by monuments and markers.)
is 1. Mylar original of approved preliminary plat (Mylar must be on file or submitted before the final plat
will be reviewed).
�7C 2. Paid tax certificates.
2 3. Drawn on 24"x 36" sheet to scale of 100' per inch or larger.
'® 4. Vicinity map which includes enough of surrounding area to show general location of subject
property in relationship to College Station and its City Limits. No scale required but include north
arrow.
5. Title Block with the following information:
(j. Name and address of subdivider, recorded owner, planner, engineer and surveyor.
2 Proposed name of subdivision. (Subdivision name & street names will be approved
through Brazos County 911.) (Replats need to retain original subdivision name.)
Date of preparation.
® Engineer's scale in feet.
VI Total area intended to be developed.
IA 6. North Arrow.
g 7. Subdivision boundary indicated by heavy lines.
❑iAlpi 8. If more than 1 sheet, an index sheet showing entire subdivision at a scale of 500 feet per inch or
larger.
❑ 9. All applicable certifications based on the type of final plat.
3 Ownership and Dedication
Ri Surveyor and/or Engineer
Ej City Engineer(and City Planner, if a minor plat)
Planning and Zoning Commission (delete if minor plat)
Er Brazos County Clerk
1119f ABrazos County Commissioners Court Approval (ETJ Plats only)
❑N l\ 10. If submitting a replat where there are existing improvements, submit a survey of the subject
property showing the improvements to ensure that no encroachments will be created.
❑O 11. If using private septic systems, add a general note on the plat that no private sewage facility may
be installed on any lot in this subdivision without the issuance of a license by the Brazos County
Health Unit under the provisions of the private facility regulations adopted by the Commissioner's
Court of Brazos County, pursuant to the provisions of Section 21.004 of the Texas Water Code.
I 12. Location of the 100-Year Floodplain and floodway, if applicable, according to the most recent
available data.
2 13. Lot corner markers and survey monuments (by symbol) and clearly tied to basic survey data.
rg 14. Matches the approved preliminary plat and/or master development plan.
El 15. The location and description with accurate dimensions, bearings or deflection angles and radii,
area, center angle, degree of curvature, tangent distance and length of all curves for all of the
following: (Show existing items that are intersecting or contiguous with the boundary of or
forming a boundary with the subdivision, as well as, those within the subdivision).
Existing Proposed
Streets. Continuous or end in a cul-de-sac, stubbed out streets must end into a temp
turn around unless they are shorter than 100 feet.
• JR1' Public and private R.O.W. locations and widths. (All existing and proposed R.O.W.'s
sufficient to meet Thoroughfare Plan.)
• El Street offsets and/or intersection angles meet ordinance.
❑ p ❑ Alleys.
• gi Easements.
ig .® A number or letter to identify each lot or site and each block.
❑ g] Greenbelt area/park linkages/parkland dedication ( All proposed dedications must be
reviewed by the Parks and Recreation Board prior to P &Z Commission consideration.)
EJ 16. Construction documents for all public infrastructure drawn on 24" x 36" sheets and properly
sealed by a Licensed Texas Professional Engineer that include the following:
X] Street, alley and sidewalk plans, profiles and sections. One sheet must show the
overall street, alley and/or sidewalk layout of the subdivision. (may be combined with
other utilities).
'W Sewer Design Report.
Sanitary sewer plan and profile showing depth and grades. One sheet must show the
overall sewer layout of the subdivision. (Utilities of sufficient size/depth to meet the
utility master plan and any future growth areas.)
Er Water Design Report and/or Fire Flow Report.
Water line plan showing fire hydrants, valves, etc. with plan and profile lines showing
depth and grades. One sheet must show the overall water layout of the subdivision.
(Utilities of sufficient size/depth to meet the utility master plan and any future growth
areas.)
'g1 Storm drainage system plan with contours, street profile, inlets, storm sewer and
drainage channels, with profiles and sections. Drainage and runoff areas, and runoff
based on 5, 10, 25, 50 and 100 year rain intensity. Detailed drainage structure design,
channel lining design & detention if used. One sheet must show the overall drainage
layout of the subdivision.
Detailed cost estimates for all public infrastructure listed above sealed by Texas P.E.
gl Drainage Report with a Technical Design Summary.
X Erosion Control Plan (must be included in construction plans).
0 17. All off-site easements necessary for infrastructure construction must be shown on the final plat
with a volume and page listed to indicate where the separate instrument easements were filed.
Separate instrument easements must be filed prior or concurrently with Final Plat. \
El 18. Are there impact fees associated with this development? K1 Yes ❑ No 504er 617-0)
Impact fees for R-1, R-2, & R-3 zoned final plats, must be paid prior to filing.
19. Will any construction occur in TexDOT rights-of-way? Yes ❑ No
If yes, TexDOT permit must be submitted along with the construction documents.
NOTE: 1. We will be requesting the corrected Final Plat to be submitted in digital form if available prior to
filing the plat at the Courthouse.
2. If the construction area is greater than 5 acres, EPA Notice of Intent (NOI) must be submitted
prior to issuance of a development permit.