HomeMy WebLinkAboutApplication FOR OFFICE USE ONLY
P&Z CASE NO.:
COLLEGE STATION
DATE SUBMITTED:
PRELIMINARY PLAT APPLICATION
The following items must be submitted by an established filing deadline date for P & Z Commission
consideration.
MINIMUM SUBMITTAL REQUIREMENTS:
X Filing Fee of $400.00.
X Variance Request to Subdivision Regulations — $100 (if applicable)
X Application completed in full.
X Thirteen (13) folded copies of plat. (A revised mylar original must be submitted after staff review.)
N/A One (1) copy of the approved Master Plan if applicable.
X A copy of the attached checklist with all items checked off or a brief explanation as to why they are not.
N/A Rezoning Application if zone change is proposed.
N/A Parkland Dedication requirement approved by the Parks & Recreation Board, please provide proof of
approval (if applicable).
Date of Preapplication Conference: Unknown
NAME OF SUBDIVISION: Duck Haven Subdivision— Phases IV, V, & VI
SPECIFIED LOCATION OF PROPOSED SUBDIVISION: West of Drake Drive
APPLICANT/PROJECT MANAGER'S INFORMATION (Primary Contact for the Project):
Name: Travis Martinek
Street Address: 3608 East 29th Street, Suite 100 City: Bryan
State: Texas Zip Code: 77802 E-Mail Address: travis@clarkewyndham.com
Phone Number: (979) 846-4384 Fax Number: (979) 846-1461
PROPERTY OWNER'S INFORMATION (ALL owners must be identified. Please attach an additional sheet for
multiple owners):
Name: Duck Haven, Ltd.
Street Address: 3608 East 29th Street, Suite 100 City: Bryan
State: Texas Zip Code: 77802 E-Mail Address: travis@clarkewyndham.com
Phone Number: (979) 846-4384 Fax Number: (979) 846-1461
ARCHITECT OR ENGINEER'S INFORMATION:
Name: McClure & Browne, Inc.
Street Address: 1008 Woodcreek Drive, Suite 103 City: College Station
State: Texas Zip Code: 77845 E-Mail Address: mikem@mcclurebrowne.com
Phone Number: (979) 693-3838 Fax Number: (979) 693-2554
6/13/03 1 of 4
Total Acres Of Subdivision: 65.7.1 R-O-W Acreage: c.89
Total # Of Lots: 50
Number Of Lots By Zoning District: N/A
Average Acreage Of Each Residential Lot By Zoning District: N/A
Floodplain Acreage: 0.00
Parkland dedication by acreage or fee? N/A
A statement addressing any differences between the Preliminary Plat and approved Master Plan (if applicable)
None
Requested variances to subdivision regulations & reason for same: See attached Variance Request. Also,
refer to attached Landing Planning Objectives and Rationale.
Requested oversize participation: None
Parkland Dedication due prior to filing the Final Plat:
ACREAGE:
# of Acres to be dedicated # of acres in floodplain
#of acres in detention # of acres in greenways
OR
FEE IN LIEU OF LAND:
# of Single-Family Dwelling Units X $556 = $
(date) Approved by Parks & Recreation Board
The applicant has prepared this application and certifies that the facts stated herein and exhibits
attached hereto are true and correct. The undersigned hereby requests approval by the City of
College Station of the above identified plat and attests that all respective owners have been identified
on this application.
//1 07
Travis Martinek Date
Design & Construc ion Manager
6/13/03 2 of
oUBMIT APPLICATION AND THIS
Ivo LIST CHECKED OFF WITH 13
FOLDED COPIES OF PLAT FOR REVIEW
COLLEGE STATION
PRELIMINARY PLAT MINIMUM REQUIREMENTS
(ALL CITY ORDINANCES MUST BE MET)
INCLUDING BUT NOT LIMITED TO THE FOLLOWING:
1. Drawn on 24" x 36" sheet to scale of 100' per inch or larger. Include the words "PRELIMINARY
PLAT - NOT FOR RECORD" in letters 1/2" high. If more than 1 sheet, an index sheet showing
entire subdivision at a scale of 500 feet per inch or larger.
® 2. Vicinity map which includes enough of surrounding area to show general location of subject
property in relationship to College Station and its City Limits. No scale required but include north
arrow.
® 3. Title Block with the following information:
® Name and address of subdivider, recorded owner, planner, engineer and surveyor.
® Proposed name of subdivision. (Subdivision name & street names will be approved
through Brazos County 911.) (Replats need to retain original subdivision name.)
® Date of preparation. (INCLUDE DATE THE PLAT WAS SUBMITTED AND THE DATES
OF ANY REVISIONS ON THE PLAT)
® Engineer's scale in feet.
® Total area intended to be developed.
® 4. North Arrow.
® 5. Location of current city limit lines and current zoning district boundary.
® 6. Subdivision boundary indicated by heavy lines. Boundary must include all of parent tract.
® 7. Descriptions by metes and bounds of the subdivision which shall close within accepted land survey
standards. (Labeled on boundary lines, not separate metes and bounds description.)
® 8. Primary control points or descriptions and ties to such control point, to which , later, all dimensions,
angles, bearings, block numbers, and similar data shall be referred. The plat shall be located with
respect to a corner of the survey or tract, or an original corner of the original survey of which it is a
part.
® 9. Name of contiguous subdivisions and names of owners of contiguous parcels of unsubdivided
land, and an indication whether or not contiguous properties are platted.
® 10. Location of the 100 Year Floodplain and Floodway, if applicable, according to the most recent
available data.
11. Topographic information, including contours at two foot (2 ft.) intervals, wooded areas, and flowline
elevation of streams.
12. Proposed land uses (In compliance with Land Use Plan).
6/13/03 3 of 4
•
13. Proposed zoning changes, if any, submit formal rezoning request.
• 14. The location and description with accurate dimensions, bearings or deflection angles and radii,
area, center angle, degree of curvature, tangent distance and length of all curves for all of the
following: (Show existing items that are intersecting or contiguous with the boundary of or forming
a boundary with the subdivision, as well as, those within the subdivision).
Existing Proposed
® ® Streets. Continuous or end in a cul-de-sac, stubbed out streets must end into a temp.
turn around unless they are shorter than 100 feet.
® ® Public and private R.O.W. locations and widths. (All existing and proposed R.O.W.'s
sufficient to meet Thoroughfare Plan.)
® ® Street offsets and/or intersection angles meet ordinance.
® ® Alleys.
® ® Reserve tracts.
® ® Well site locations.
® ® Pipelines. If carrying flammable gas or fuel, also show size of line, design pressure and
1 product transported through the line.
• ® Utility Services. (Water & Sanitary Sewer) All existing and proposed utilities of sufficient
size/depth to meet the utility master plan and any future growth areas.
® ® Easements.
® ® Drainage Structures and improvements including underground storm sewer and all
overland systems (flow line of existing watercourses) and showing where these will
discharge. Proposed channel cross sections, if any.
® ® A number or letter to identify each lot or site and each block.
® Greenbelt area/park linkages/parkland dedication ( All proposed dedications must be
reviewed by the Parks and Recreation Board prior to P & Z Commission consideration.)
® ® Public areas
® ® Other public improvements, including but not limited to parks, schools and other public
facilities
• 15. Proposed phasing. Each phase must be able to stand alone to meet ordinance requirements and
infrastructure costs should be distributed evenly throughout the subdivision..
• 16. Are there impact fees associated with this development? ❑ Yes ® No
• 17. If requesting oversize participation items, are the necessary impact studies included?
❑Yes
❑No
®N/A
6/13/03 4 of
FOR OFFICE USE ONLY
P&Z CASE NO.: 01 -
COLLEGE STATION
DATE SUBMITTED: c
PRELIMINARY PLAT APPLICATION (-0
The following items must be submitted by an established filing deadline date for P & Z Commission
consideration.
MINIMUM SUBMITTAL REQUIREMENTS:
X Filing Fee of$400.00.
X Variance Request to Subdivision Regulations - $100 (if applicable)
X Application completed in full.
X Thirteen (13) folded copies of plat. (A revised mylar original must be submitted after staff review.)
N/A One (1) copy of the approved Master Plan if applicable.
X A copy of the attached checklist with all items checked off or a brief explanation as to why they are not.
N/A Rezoning Application if zone change is proposed.
N/A Parkland Dedication requirement approved by the Parks & Recreation Board, please provide proof of
approval (if applicable).
Date of Preapplication Conference: Unknown 5,
NAME OF SUBDIVISION: Duck Haven Subdivision- Phases IV, V, VI, VII, & VIII ^\tea
SPECIFIED LOCATION OF PROPOSED SUBDIVISION: West of Drake Drive
APPLICANT/PROJECT MANAGER'S INFORMATION (Primary Contact for the Project):
Name: Travis Martinek
Street Address: 3608 East 29th Street, Suite 100 City: Bryan
State: Texas Zip Code: 77802 E-Mail Address: travis@clarkewyndham.com
Phone Number: (979) 846-4384 Fax Number: (979) 846-1461
PROPERTY OWNER'S INFORMATION (ALL owners must be identified. Please attach an additional sheet for
multiple owners):
Name: Duck Haven, Ltd.
Street Address: 3608 East 29th Street, Suite 100 City: Bryan
State: Texas Zip Code: 77802 E-Mail Address: travis@clarkewyndham.com
Phone Number: (979) 846-4384 Fax Number: (979) 846-1461
ARCHITECT OR ENGINEER'S INFORMATION:
Name: McClure & Browne, Inc.
Street Address: 1008 Woodcreek Drive, Suite 103 City: College Station
State: Texas Zip Code: 77845 E-Mail Address: mikem@mcclurebrowne.com
Phone Number: (979) 693-3838 Fax Number: (979) 693-2554
6/13/03
1 of4
Total Acres Of Subdivision: 89.-.5 R-O-W Acreage: /.88
Total # Of Lots: 63
Number Of Lots By Zoning District: N/A
Average Acreage Of Each Residential Lot By Zoning District: N/A
Floodplain Acreage: 0.00
Parkland dedication by acreage or fee? N/A
A statement addressing any differences between the Preliminary Plat and approved Master Plan (if applicable)
None
Requested variances to subdivision regulations & reason for same: See attached Variance Request. Also,
refer to attached Landing Planning Objectives and Rationale.
Requested oversize participation: None
Parkland Dedication due prior to filing the Final Plat:
ACREAGE:
# of Acres to be dedicated # of acres in floodplain
# of acres in detention # of acres in greenways
OR
FEE IN LIEU OF LAND:
# of Single-Family Dwelling Units X $556 = $
(date) Approved by Parks & Recreation Board
The applicant has prepared this application and certifies that the facts stated herein and exhibits
attached hereto are true and correct. The undersigned hereby requests approval by the City of
College Station of the above identified plat and attests that all respective owners have been identified
on this application.
(1/77.2,-/ 02 /N/07
Travis Martinek Date
Design & Construction Manager
6/13/03
2 of 4
T SUBMIT APPLICATION AND THIS
(S_ LIST CHECKED OFF WITH 13
FOLDED COPIES OF PLAT FOR REVIEW
COLLEGE STATION
PRELIMINARY PLAT MINIMUM REQUIREMENTS
(ALL CITY ORDINANCES MUST BE MET)
INCLUDING BUT NOT LIMITED TO THE FOLLOWING:
® . Drawn on 24" x 36" sheet to scale of 100' per inch or larger. Include the words "PRELIMINARY
PLAT - NOT FOR RECORD" in letters 1/2" high. If more than 1 sheet, an index sheet showing
entire subdivision at a scale of 500 feet per inch or larger.
® 2. Vicinity map which includes enough of surrounding area to show general location of subject
property in relationship to College Station and its City Limits. No scale required but include north
arrow.
® 3. Titl= :lock with the following information:
�.,- ►1 Name and address of subdivider, recorded owner, planner, engineer and surveyor.
i/ Proposed name of subdivision. (Subdivision name & street names will be approved
through Brazos County 911.) (Replats need to retain original subdivision name.)
r/ Date of preparation. (INCLUDE DATE THE PLAT WAS SUBMITTED AND THE DATES
OF ANY REVISIONS ON THE PLAT)
yrgi Engineer's scale in feet.
►'1 Total area intended to be developed.
® . North Arrow.
® Ni A L ation of current city limit lines and current zoning district boundary.
® 6. Su [vision boundary indicated by heavy lines. Boundary must include all of parent tract.
® 7 escriptions by metes and bounds of the subdivision which shall close within accepted land survey
ii,
sta dards. (Labeled on boundary lines, not separate metes and bounds description.)
V1U
'1CY1 �
® 8 Primary control points or descriptions and ties to such control point, to which , later, all dimensions,
angles, bearings, block numbers, and similar data shall be referred. The plat shall be located with
respect to a corner of the survey or tract, or an original corner of the original survey of which it is a
part.
® 9. ame of contiguous subdivisions and names of owners of contiguous parcels of unsubdivided
land, and an indication whether or not contiguous properties are platted.
® 1 ocation of the 100 Year Floodplain and Floodway, if applicable, according to the most recent
available data.
® 1 . opographic information, including contours at two foot (2 ft.) intervals, wooded areas, and flowline
e vation of streams.
® . Proposed land uses (In compliance with Land Use Plan).
6/13/03
3of4
Z jr\3.� Proposed zoning changes, if any, submit formal rezoning request.
® t>41 /"The location and description with accurate dimensions, bearings or deflection angles and radii,
area, center angle, degree of curvature, tangent distance and length of all curves for all of the
following: (Show existing items that are intersecting or contiguous with the boundary of or forming
a boundary with the subdivision, as well as, those within the subdivision).
Existing Proposed
® ® treets. Continuous or end in a cul-de-sac, stubbed out streets must end into a temp.
rn around unless they are shorter than 100 feet.
® ® Public and private R.O.W. locations and widths. (All existing and proposed R.O.W.'s
S sufficient to meet Thoroughfare Plan.)
® ® s /Street offsets and/or intersection angles meet ordinance.
® ® _..----Alleys.
® ® --_ esReserw, tracts.
® a i'ytft/�1 site locations.
® IA --Pipelines. If carrying flammable gas or fuel, also show size of line, design pressure and
pro ct transported through the line.
® ® tility Services. (Water & Sanitary Sewer) All existing and proposed utilities of sufficient
se/depth to meet the utility master plan and any future growth areas.
® ® asements.
® ® ( drainage Structures and improvements including underground storm sewer and all
overland systems (flow line of existing watercourses) and showing where these will
discharge. Proposed channel cross sections, if any.
® ® VA number or letter to identify each lot or site and each block.
® ®._greenbelt area/park linkages/parkland dedication ( All proposed dedications must be
reviewed by the Parks and Recreation Board prior to P & Z Commission consideration.)
® a Public areas
® Z____--Other public improvements, including but not limited to parks, schools and other public
facilities
® Proposed phasing. Each phase must be able to stand alone to meet ordinance requirements and
V infrastructure costs should be distributed evenly throughout the subdivision..
® 1.7- Are there impact fees associated with this development? ❑ Yes ® No
® o/. If requesting oversize participation items, are the necessary impact studies included?
❑Yes
❑No
®N/A
i .u+ \ D
��,) ' i ,ar-0 7
\, (-___, i
, Kc...) r\)4
\c...,c--
\ , i , ..\,/,__ c -0 ,
. , ,,,,
,,,, kr--\\)/x) rN , -A (\)x
\ .„ \\ ,H-A
6/13/03 I� � 4 of 4
,�\ti.
FOR OFFICE USE ONLY
P&Z CASE NO.: 01 - , -C/1
COEEccE S ;UON DATE SUBMITTED: , fl�'SO1
PRELIMINARY PLAT APPLICATION
The following items must be submitted by an established filing deadline date for P & Z Commission
consideration.
MINIMUM SUBMITTAL REQUIREMENTS:
X Filing Fee of$400.00.
X Variance Request to Subdivision Regulations —$100 (if applicable)
X Application completed in full.
X Thirteen (13) folded copies of plat. (A revised mylar original must be submitted after staff review.)
N/A One (1) copy of the approved Master Plan if applicable.
X A copy of the attached checklist with all items checked off or a brief explanation as to why they are not.
N/A Rezoning Application if zone change is proposed.
N/A Parkland Dedication requirement approved by the Parks & Recreation Board, please provide proof of
approval (if applicable).
Date of Preapplication Conference: Unknown
NAME OF SUBDIVISION: Duck Haven Subdivision—Phases IV, V, VI, VII, & VIII
SPECIFIED LOCATION OF PROPOSED SUBDIVISION: West of Drake Drive
APPLICANT/PROJECT MANAGER'S INFORMATION (Primary Contact for the Project):
Name: Travis Martinek
Street Address: 3608 East 29th Street, Suite 100 City: Bryan
State: Texas Zip Code: 77802 E-Mail Address: travis@clarkewyndham.cam
Phone Number: (979) 846-4384 Fax Number: (979) 846-1461
PROPERTY OWNER'S INFORMATION (ALL owners must be identified. Please attach an additional sheet for
multiple owners):
Name: Duck Haven, Ltd.
Street Address: 3608 East 29th Street, Suite 100 City: Bryan
State: Texas Zip Code: 77802 E-Mail Address: travis@clarkewyndham.com
Phone Number: (979) 846-4384 Fax Number: (979) 846-1461
ARCHITECT OR ENGINEER'S INFORMATION:
Name: McClure & Browne, Inc.
Street Address: 1008 Woodcreek Drive, Suite 103 City: College Station
State: Texas Zip Code: 77845 E-Mail Address: mikem@mcciurebrowne_com
Phone Number: (979) 693-3838 Fax Number: (979) 693-2554
6/13/03 1 4 4
Total Acres Of Subdivision: 89.' R-O-W Acreage: 7.88
Total#Of Lots: 63
Number Of Lots By Zoning District: N/A
Average Acreage Of Each Residential Lot By Zoning District: N/A
Floodplain Acreage: 0.00
Parkland dedication by acreage or fee? N/A
A statement addressing any differences between the Preliminary Plat and approved Master Plan (if applicable)
None
Requested variances to subdivision regulations & reason for same: See attached Variance Request. Also,
refer to attached Landing Planning Objectives and Rationale.
Requested oversize participation: None
Parkland Dedication due prior to filing the Final Plat:
ACREAGE:
#of Acres to be dedicated #of acres in floodplain
#of acres in detention #of acres in greenways
OR
FEE IN LIEU OF LAND:
#of Single-Family Dwelling Units X $556 =$
(date)Approved by Parks & Recreation Board
The applicant has prepared this application and certifies that the facts stated herein and exhibits
attached hereto are true and correct. The undersigned hereby requests approval by the City of
College Station of the above identified plat and attests that all respective owners have been identified
on this application.
-V,�...• 4/1 /N./0-7
Travis Martinek Date
Design & Construction Manager
h113(03 2 of 4
FOR OFFICE USE ONLY
\/ P&Z CASE NO.: 01 '��
COLL4CA
DATE SUBMITTED: 'I�'60
PRELIMINARY PLAT APPLICATION
The following items must be submitted by an established filing deadline date for P & Z Commission
consideration.
MINIMUM SUBMITTAL REQUIREMENTS:
X Filing Fee of $400.00.
X Variance Request to Subdivision Regulations —$100 (if applicable)
X Application completed in full.
X Thirteen (13) folded copies of plat. (A revised mylar original must be submitted after staff review.)
N/A One (1) copy of the approved Master Plan if applicable.
X A copy of the attached checklist with all items checked off or a brief explanation as to why they are not.
N/A Rezoning Application if zone change is proposed.
N/A Parkland Dedication requirement approved by the Parks & Recreation Board, please provide proof of
approval (if applicable).
Date of Preapplication Conference: Unknown
NAME OF SUBDIVISION: Duck Haven Subdivision—Phases IV, V, VI, VII, & VIII
SPECIFIED LOCATION OF PROPOSED SUBDIVISION: West of Drake Drive
APPLICANT/PROJECT MANAGER'S INFORMATION (Primary Contact for the Project):
Name: Travis Martinek
Street Address: 3608 East 29th Street, Suite 100 City: Bryan
State: Texas Zip Code: 77802 E-Mail Address: travis@clarkewyndham.com
Phone Number: (979) 846-4384 Fax Number: (979) 846-1461
PROPERTY OWNER'S INFORMATION (ALL owners must be identified. Please attach an additional sheet for
multiple owners):
Name: Duck Haven, Ltd.
Street Address: 3608 East 29th Street, Suite 100 City: Bryan
State: Texas Zip Code: 77802 E-Mail Address: travis@clarkewyndham.com
Phone Number: (979) 846-4384 Fax Number: (979) 846-1461
ARCHITECT OR ENGINEER'S INFORMATION:
Name: McClure & Browne, Inc.
Street Address: 1008 Woodcreek Drive, Suite 103 City: College Station
State: Texas Zip Code: 77845 E-Mail Address: mikem@mcclurebrowne.com
Phone Number: (979) 693-3838 Fax Number: (979) 693-2554
6/13/03 l oro
Total Acres Of Subdivision: 89.40 R-O-W Acreage: 7.88
Total #Of Lots: 63
Number Of Lots By Zoning District: N/A
Average Acreage Of Each Residential Lot By Zoning District: N/A
Floodplain Acreage: 0.00
Parkland dedication by acreage or fee? N/A
A statement addressing any differences between the Preliminary Plat and approved Master Plan (if applicable)
None
Requested variances to subdivision regulations & reason for same: See attached Variance Request. Also,
refer to attached Landing Planning Objectives and Rationale.
Requested oversize participation: None
Parkland Dedication due prior to filing the Final Plat:
ACREAGE:
#of Acres to be dedicated #of acres in floodplain
#of acres in detention #of acres in greenways
OR
FEE IN LIEU OF LAND:
#of Single-Family Dwelling Units X $556 =$
(date) Approved by Parks & Recreation Board
The applicant has prepared this application and certifies that the facts stated herein and exhibits
attached hereto are true and correct. The undersigned hereby requests approval by the City of
College Station of the above identified plat and attests that all respective owners have been identified
on this application.
• AZ/0-7
Travis Martinek Date
Design & Construction Manager
6113103 2of4