HomeMy WebLinkAboutCorrespondence 411144414 CITY OF COLLEGE STATION Planning d Development Services 1101 Texas Avenue,P.O. Box 9960 College Station,Texas 77842 Phone 979.764.3570 / Fax 979.764.3496 MEMORANDUM March 12,2007 • TO: Brett McCully,Bleyl&Associates via fax# 979.260.3849 FROM: Crissy Hard,Staff Planner SUBJECT: MID SOUTH BANK(SP) - Site Plan Staff reviewed the above-mentioned site plan ments on the site plan or engineering documents. Please submit the follow - ktb. royal: Seven (7) complete sets of cons osed development with the revised site and landscaping p . returned to you, please submit additional copies if yo d set) iff Two (2) revised individual site p. One (1) landscaping plan One (1) 11x17 grading and erosic ja 1( -r E SBA professionalUSSD RArchtte ActuSrSal°CCoripoAration) Easement Dedication Sheet and JAMES K. BROUSSARD,AIA Architect If you have any questions or need additional infori ;570. 1023 East St.Mary Blvd. Attachments: Staff review commentsP.O.Box 5351.7. Lafayette,Louisiana 70505-3517 (337)235-5004 Fax(337)235-5089 james.bajbaarchitect.com cc: H.E. Butt Grocery Company,PO Box 839111111.0.1.11.1111.1111 James Broussard,via fax# 337.235.5089 Case file#07-00500020 Home of Texas A&M University Adak, James r;10, I BROUSSARD & ASSOCIATES (A Professional Architectural Corporation) Ms. Crissy Hart City of College Station Planning&Development Services P. 0.Box 9960 College Station,Texas 77842 979-764-3570 RE: MidSouth Bank(SP)—Site Plan Staff Review Comments No. 2 College Station,TX Dear Ms.Hart: The following is our response to your memo dated February 19,2007 and changes have been made to our documents. PLANNING AND LANDSCAPING/STREETSCAPING: 1)Please dimension three queing spaces for the ATM window on the north side of the building and verify that this requirement as well as other standards,such as drive-aisle widths,is also being met. Three queing spaces are shown,all with dimensions at the ATM location.Four queing spaces are shown,all with dimensions at the Teller Drive Thru location.The drive aisles are designed meeting the manufacture's requirements. Re: Sheet C1.02 2) Staffs calculation of the proposed landscaping points indicated that 5,672 points were proposed as opposed to the 5,822 points on the legend. Please verify. Re: Sheet L2 3) Staff was only able to verify that 15 street trees were being provided within 50'of the property line along the two thoroughfares. Please provide an additional two canopy trees along the streets. As a reminder,two non-canopy may be substituted for one canopy tree. Re: Sheet L2 4) Staff noticed that the dumpster is located on an easement. Please be aware of the following and add a note to the site plan that states that if utilities need to be accessed within the easement and the dumpster enclosure needs to be removed,that it will be the owner's responsibility to repair or replace the structure. Additionally,please keep the structure at least 5 feet away from the manhole to provide a workspace. The dumpster has been relocated meet the requested(5)five feet distance from the manhole to structure.The requested note has been added to the site plan. Re: Sheet C1.02 P. 0. BOX 53517 LAFAYETTE, LOUISIANA 70505-3517 PH.: (337) 235-5004 FAX: (337) 235-5089 NON-RESIDENTIAL ARCHITECTURAL COMMENTS: 1) Per Section 7.9 NRA Standards,two architectural elements are required on facades facing a public ROW for every 45'horizontal feet. This standard applies to the facades facing Texas Avenue(east)and Holleman Drive (south). Additionally,two architectural elements are required on all other facades for every 60'horizontal feet (north and west). Please find evaluations of each façade below and revise the building plans as necessary: a. East elevation: Staff counted the wall plane projection as two elements,but it is still lacking two required elements. Canopies over the windows would satisfy this requirement. Canopies have been added to the east elevation. Re: Sheet A3.01 b. South elevation: Staff counted the canopy and wall plane projection as two elements,but it is still lacking two required elements. Canopies have been added to the south elevation. Re: Sheet A3.01 c. West elevation: Staff counted the canopy as one element out of the two required elements. Extending the teller window projection to 4'would satisfy this requirement. A canopy over the reader board has been added to the west elevation. Re: Sheet A3.01 d. North elevation: Staff counted the canopy as one element out of the two required elements. Please provide another architectural feature. Canopies have been added to the north elevation. Re: Sheet A3.01 2) Please provide a sample of the proposed roof material to verify that it is either copper or silver metallic as required by the UDO. Color samples and materials will be submitted. 3) Please be aware that all signs will be permitted separately. We are aware and addressed this issue on the previous comments from your department. ENGINEERING COMMENTS NO. 1 1) A 4-in. sanitary sewer service line requires a 1%slope,please illustrate. Re: Bleyl&Associates response dated February 26,2007 2) Please provide water and sewer demands and specify size of water meters. Re:Bleyl&Associates response dated February 26,2007 and M&E Consulting,Inc. response. 3) Please illustrate proposed location for the domestics and irrigation meter. These meters need to be located within an easement. It appears the proposed meter location is outside of an easement,please dedicate. Re:Bleyl&Associates response dated February 26,2007 and M&E Consulting,Inc.response. 4) Please dedicate an easement for any on-site public utility that are not already located in an easement. Re:Bleyl&Associates response dated February 26,2007. 5) Please illustrate canopy height on site plan. Canopy has been noted on the site plan. Re: Sheet C1.02 6) Please label the existing water service/fire line to be removed. Re: Bleyl&Associates response dated February 26,2007 and M&E Consulting,Inc.response. 7) Fire Flow: The fire flow report is needed to verify the number of hydrants required per tables B105.1 and C105.1 of the fire code,using the proposed square footage and building material type,please submit. Re:Bleyl&Associates response dated February 26,2007. 8) Drainage Report: It appears from the grading plan that the existing and proposed contours are very similar,I assume the overall drainage pattern for the proposed site will remain the same as the existing site,please verify. Re:Bleyl&Associates response dated February 26,2007. 9) Please submit development permit and fees. Re:Bleyl&Associates response dated February 26,2007. Please call our office should you need any additional information. Sincerely, Ronald Ayo—Assoc. AIA ronald.a@jbaarchictect.com James Broussard&Associates (A Professional Architectural Corporation) 337-235-5004 RJA/rja Enclosures CC: MidSouth Bank F.D.Freeman Associates,Inc. Bleyl&Associates M&E Consulting,Inc. ,. • , I I I M 4' E CONSULTING, INC. MI A PROFESSIONAL ENGINEERING CORPORATION m= 1304 BERTRAND DRIVE • SUITE A6 MI LAFAYETTE.LOUISIANA 70506 MN „ i3:3•fl 234-7474 • FAX(337)234-7774 --- .... ......--- www.meconsulting.corn February 26, 2007 James Broussard James Broussard & Associates P.O. Box 53517 Lafayette, LA 70505-3517 Re: Midsouth Bank -College Station,TX M&E 06197.00 Dear James: The following are Mechanical/Electrical responses to the 19Feb07 comments from the City of College Station. Engineering Comments 1 Item No. 1: A. A 4" sanitary sewer service line requires a I%slope-please illustrate. Response: A slope of 1/8" per foot is specified. Reference Specification 15350. 2. Item No. 2: A. Please provide water and sewer demands and specify size of water meters. Response: These are indicated on Drawings M1.01. 3, Item No. 3: A. Please illustrate proposed location for the domestic and irrigation meter. These meters need to be located within an easement. It appears the proposed meter location is outside of an casement. Please dedicate, Response: These items arc addressed on Drawings M1.01,and in Addendum No. 1. 4. Item No. 6: A. Please label the existing water service/fire line to be removed. Response: This is shown on Drawing M1.01 and Note No.2. _I SCOTTY J. BAUDOIN, RE. JAY BREAUX. RE RICHARD M. LEH LANc L The following are Mechanical/Electrical responses to the 19Feb07 comments from the City of College Station. 1. Item No. 1: A. Provide emergency exterior"Exit Discharge" lighting requirement for all exits to comply with Section 1006.3#5 of the 2003 IBC. Response: Emergency lighting will be specified, in the next addendum,at exterior exits as required. 2. Item No. 8: A. Submit Lighting and Mechanical Compliance data to comply with the 2003 IECC, Response: This was submitted. A copy is attached. -End of Items- If you need additional information please contact our office. Sincerely, 410 / Richard M. LeBlanc Electrical Project Manager M&E Consulting,Inc. !I'4605197`,0t197 02,..pd (*#"11114 CITY OF COLLEGE STATION Planning es Development Services 1101 Texas Avenue,P.O. Box 9960 College Station,Texas 77842 Phone 979.764.3570 / Fax 979.764.3496 MEMORANDUM February 19, 2007 TO: Brett McCully, PE via fax # 260.3849 FROM: Crissy Hartl, Staff Planner SUBJECT: MID SOUTH BANK (SP) - Site Plan Staff reviewed the above-mentioned site plan as requested. The following page is a list of staff review comments detailing items that need to be addressed. The next submittal will be the third and final review by staff for this round of reviews. If all items have not been addressed on the next submittal, another $200 processing fee will need to be submitted for the subsequent set of three (3) reviews. Please address the comments and submit the following information for further staff review: One (1) revised site and landscaping plan. If there are comments that you are not addressing with the revised site plan, please attach a letter explaining the details. If you have any questions or need additional information, please call me at 764-3570. Attachments: Staff review comments cc: H.E. Butt Grocery Company, PO Box 839999, San Antonio, TX 78283 James Broussard, AIA via fax # 337.235.5089 Case file #07-00500020 = B Bleyl & Associates 1722 Broadmoor 1. & Suite 210 Project Engineering & Management Bryan, TX 77802 liL A : 11111111111114M111. I-r} CnW7 , ,,� ka. 1)3 February 26, 2007 ' k Ms. Crissy Hartl, Staff Planner l ^ ,, ��` Planning and Development Sevices 1101 Texas Avenue, P.O. Box 9960 College Station, Texas 778420`Y- 'S RE: Mid-South Bank Site Plan Comment �� Case #07-005000205 Dear Ms. Hartl, Following are your planning comments from the February 12 review of the referenced project. Our resolution is shown next to each comment in italics. PLANNING AND LANDSCAPING /STREETSCAPING 1. Please dimension three queuing spaces for ATM window on the north side of the building and verify that this requirement as well as other standards, such as drive-aisle width, is also being met. Queuing spaces are now shown. 2. Staff's calculation of the proposed landscaping points indicated that 5,672 points were proposed as opposed to the 5,822 points on the legend. Please verify. This will addressed by Landscape Architect. 3. Staff was only able to verify that 15 street trees were being provided within 50' of the property line along the two thoroughfares. Please provide an additional two canopy trees along the streets. As a reminder, two non-canopy trees may be substituted for one canopy tree. This will addressed by Landscape Architect. 4. Staff noticed the dumpster is located on an easement. Please be aware of the following and add a note to the site plan that states that if utilities need to be accessed within the easement and the dumpster enclosure needs to be removed, that it will be the owner's responsibility to repair or replace the structure. Additionally, please keep the structure at least 5 feet away from the manhole to provide a workspace. A note describing the owner's responsibility has been added and the structure has been moved. ENGINEERING COMMENTS NO. 1 ie . A 4-in sanitary sewer service line requires a 1% slope, please illustrate. The proposed slope of the pipe is now shown. Plea - • - .: -nd sewer demands and specify size of water meters. The •emand ha a add-• an• -eter size called out for the domestic meter. The Bryan Austin Conroe (979)-268-1125 (512)-328-7878 (936)-441-7833 (979)-260-3849 (512)-328-7884 Fax (936)-760-3833 Fax irrigation meter will be located in the same place as the original water meter. Meter size will be determined by licensed irrigator. 701. Please illustrate proposed location for the domestic and irrigation meter. These meters need to be located within an easement. It appears the proposed me er 2 locati•• • ide of an easement, please dedicate. A proposed •edication i , shown. 4. ' - -ge dedicate an easement for any on-site public utility that are not already located in an easement. A proposed easement dedication is now shown. Please illustrate canopy height. A note calling out the minimum elevation is now shown. Please label existing water service / fire line to be removed. A note has been 0 added. Fire Flow: The fire flow report is needed to verify the number of hydrants required per tables B105.1 and C105.1 of the fire code, using the proposed square footage and building material type, please submit. Drainage Report: It appears from the grading plan that the existing and roposed contours are very similar. I assume the overall drainage pattern for the proposed site will remain the same as the existing site, please verify. Please submit development permit and fees. These have been submitted. Please do not hesitate to contact me with any questions, or if you require additional information. Sinc- ely, //9Y1f/ -ttA. M ully, P.E. Senior En ineer _ B Bleyl & Associates 1722 Broadmoor ilk& Suite 210 A Project Engineering & Management Bryan, TX 77802 /tel February 26, 2007 Josh Norton Planning& Development Services `-'' City of College Station P.O. Box 9960 College Station, TX 77840 Re: Mid South Bank Supporting Drainage and Fire Flow Information Josh, This letter should serve to address comments 7 and 8 of your February 19th comments regarding this project. Fire Demand The proposed building will be approximately 3242 square feet. Based upon the worst building construction category (Type V-B), IFC Table B105.1 states that only 1500 gpm would be required. For this flow rate, IFC Table C105.1 allows the use of a single fire hydrant. Since we are retaining the existing fire hydrant onsite, we believe the fire demand issue has been resolved. Developed Drainage As your comment notes, the existing drainage patterns are being followed to remain compliant with the latest HEB site drainage analysis. The proposed site also will provide slightly less impervious area than the existing structures, reducing flow somewhat. As always, please feel free to contact me shoul,. rou have any further questions, or comments. i `"`" ,. At?, Oen i &_..��,yy:'t9 Yom° ,¢y r' �' Sincerely, `' ' B -tt/if ul , P.E. K. �r f Sr. En neer/Branch Manager0,1',:,.2 !:,-'”,m rs c ';:,-, .-L„.,,-,.. Bryan Austin Conroe (979)-268-1125 (512)-328-7878 (936)-441-7833 (979)-260-3849 (512)-328-7884 Fax (936)-760-3833 Fax • Appendix C FIRE HYDRANT LOCATIONS AND DISTRIBUTION SECTION C101 SECTION C104 GENERAL CONSIDERATION OF EXISTING FIRE HYDRANTS C101.1 Scope.Fire hydrants shall be provided in accordance C104.1 Existing fire hydrants.Existing fire hydrants on pub- with this appendix for the protection of buildings,or portions of lic streets are allowed to be considered as available. Existing buildings,hereafter constructed. fire hydrants on adjacent properties shall not be considered available unless fire apparatus access roads extend between SECTION C102 properties and easements are established to prevent obstruction LOCATION of such roads. C102.1 Fire hydrant locations. Fire hydrants shall be pro- vided along required fire apparatus access roads and adjacent public streets. SECTION C105 • DISTRIBUTION OF FIRE HYDRANTS SECTION C103 C105.1 Hydrant spacing.The average spacing between fire NUMBER OF FIRE HYDRANTS hydrants shall not exceed that listed in Table C105.1. C103.1 Fire hydrants available.The minimum number of fire Exception: The fire chief is authorized to accept a defi- hydrants available to a building shall not be less than that listed ciency of up to 10 percent where existing fire hydrants pro- in Table C105.1. The number of fire hydrants available to a vide all or a portion of the required fire hydrant service. complex or subdivision shall not be less than that determined by spacing requirements listed in Table C105.1 when applied to Regardless of the average spacing,fire hydrants shall be 10- ( fire apparatus access roads and perimeter public streets from cated such that all points on streets and access roads adjacent to which fire operations could be conducted. a building are within the distances listed in Table C105.1. TABLE C105.1 NUMBER AND DISTRIBUTION OF FIRE HYDRANTS AVERAGE SPACING MAXIMUM DISTANCE FROM ARE-FLOW REQUIREMENT MINIMUM NUMBER BETWEEN HYDRANTS'b'` ANY POINT ON STREET OR ROAD (gpm) OF HYDRANTS (feet) FRONTAGE TO A HYDRANTa —�� 1,750 or less 1 500 250 •2,000-2,250 2 450 225 2,500 3 450 225 3,000 3 400 225 3,500-4,000 4 350 210 4,500-5,000 5 300 180 5,500 6 300 180 6,000 . 6 250 150 6,500-7,000 7 250 150 7,500 or more 8 or moree 200 120 For SI: 1 foot=304.8 mm,1 gallon per minute=3.785 Um. a. Reduce by 100 feet for dead-end streets or roads. b. Where streets are provided with median dividers which can be crossed by fire fighters pulling hose lines,or where arterial streets are provided with four or more traffic lanes and have a traffic count of more than 30,000 vehicles per day,hydrant spacing shall average 500 feet on each side of the street and be arranged on an al- ternating basis up to a fire-flow requirement of 7,000 gallons per minute and 400 feet for higher fire-flow requirements. c. Where new water mains are extended along streets where hydrants are not needed for protection of structures or similar fire problems,fire hydrants shall be pro- vided at spacing not to exceed 1,000 feet to provide for transportation hazards. d. Reduce by 50 feet for dead-end streets or roads. • e. One hydrant for each 1,000 gallons per minute or fraction thereof. 2000 INTERNATIONAL FIRE CODE® • 359 APPENDIX B . .RE-FLOW REQUIREMENTS FOR Btu, TABLE B105.1 MINIMUM REQUIRED FIRE FLOW AND FLOW DURATION FOR BUILDINGS FIRE AREA(square feet) FIRE FLOW FLOW Type IA and IB' Type IIA and IIIA' Type IV and V-Aa Type JIB and IIIB' Type V-B' (gallons per minute)" DURATION(hours) 0-22,700 0-12,700 0-8,200 0-5,900 _ 0-3,600 1,500 mewn•.-- 22,701-30,200 22,701-30,200 12,701-17,000 8,201-10,900 - 5,901-7,900 3,601-4,800 1,750 30,201-38,700 17,001-21,800 10,901-12,900 7,901-9,800 4,801-6,200 2,000 38,701-48,300 21,801-24,200 12,901-17,400 9,801-12,600 6,201-7,700 _ 2,250 2 48,301-59,000 24,201-33,200 17,401-21,300 _ 12,601-15,400 7,701-9,400 2,500 59,001-70,900 33,201-39,700 21,301-25,500 15,401-18,400 9,401-11,300 2,750 70,901-83,700 39,701-47,100 25,501-30,100 18,401-21,800 11,301-13,400 3,000 83,701-97,700 47,101-54,900 30,101-35,200 21,801-25,900 -13,401-15,600 3,250 97,701-112,700 54,901-63,400 35,201-40,600 25,901-29,300 15,601-18,000 3,500 3 112,701-128,700 63,401-72,400 40,601-46,400 29,301-33,500 18,001-20,600 3,750 128,701-145,900 72,401-82,100 46,401-52,500 33,501-37,900 ;20,601-23,300 4,000 145,901-164,200 . 82101-92,400 52501-59,100 37,901-42,700 23,301-26,300 4,250 164,201-183,400 92,401-103,100 59,101-66,000 42,701-47,700 26,301-29;300 4,500 183,401-203,700 • 103,101-114,600 66,001-73,300 47,701-53,000 29,301-32,600 4,750 203,701.225,200 114,601-126,700 73,301-81,100 53,001-58,600 ,32601-36,000 5,000 225,201-247,700 126,701-139,400 81,101-89,200 58,601-65,400 36,001-39,600 5,250 247,701-271,200 139,401-152,600 89,201-97,700 65,401-70,600 39,601-43,400 5,500 271,201-295,900 152,601-166,500 97,701-106,500 70,601-77,000 43,401-47,400 _ 5,750 295,901-Greater 166,501-Greater 106,501-115,800 77,001-83,700 47,401-51,500 6,000 4 115,801-125,500 83,701-90,600 51,501-55,700 6,250 125,501-135,500 90,601-97,900 55,701-60,200 6,500 - 135,501-145,800 97,901-106,800 60,201-64,800 6,750 - , - 145,801-156,700 106,801-113,200 64,801-69,600 7,000 - -• 156,701-167,900 113,201-121,300 69,601-74,600 7,250 _ 167,901-179,400 121,301-129,600 74,601-79,800 7,500 179,401-191,400 129,601-138,300 79,801-85,100 7,750 • - 191,401-Greater 138,301-Greater 85,101-Greater 8,000 For SI: 1 square foot=0.0929 m2, I gallon per minute=3.785 L/m, I pound per square inch=6.895 kPa. a. Types of construction are based on the International Building Code. b. Measured at 20 psi. • 358 - - ?Mn INTF RN ATI/lKIAr.r.r...... ENGINEERING COMMENTS NO. 1 to A 4-in sanitary sewer service line requires a 1% slope,please illustrate. ' i ase provide water and sewer demands and specify size of water meters. 3. 'ease 1 . trate proposed location for the domestics and irrigation meter. These meters need to b: located within an easement. It appears the proposed meter location is outside of an ease nt,please dedicate. ( 4. Pose dedicate an easement for any on-site public utility that are not already located in an ----- easement. . illustrate canopy height on site plan. fi Please label the existing water service / fire line to be removed.calee ie Fire Flow: The fire flow report is needed to verify the number of hydrants required per tables B105.1 and C105.1 of the fire code, using the proposed square footage and building material type,please submit. bel rainage Report: It appears from the grading plan that the existing and proposed contours are very similar, I assume the overall drainage pattern for the proposed site will remain the s the existing site,please verify. .9. P e submit development permit and fees. Reviewed by: Josh Norton Date: February 19, 2007 �� AI. (4:L. ,,,,, /,,....-6(A.14E (*//"14 CITY Or COLLEGE STATION Planning d Development Services 1101 Texas Avenue, P.O. Box 9960 College Station, Texas 77842 Phone 979.764.3570/ Fax 979.764.3496 MEMORANDUM February 5, 2007 TO: Brett McCully, PE FROM: Crissy Hartl, Staff Planner SUBJECT: MID SOUTH BANK (SP)- Site Plan Staff reviewed the above-mentioned site plan as requested. The following page is a list of staff review comments detailing items that need to be addressed. Please address the comments and submit the following information for further staff review: One (1) revised site and landscaping plan. Easement Dedication Sheet and required documents. Please note that the Easement Dedication Sheet and necessary documents are required prior to the issuance of a building permit. If there are comments that you are not addressing with the revised site plan, please attach a letter explaining the details. If you have any questions or need additional information, please call me at 979.764.3570. Attachments: Staff review comments pc: H.E. Butt Grocery Company, PO Box 839999, San Antonio, TX 78283 James Broussard, AIA via fax# 337.235.5089 Case file #07-00500020 Home of Texas A&M University TRANSMISSION VERIFICATION REPORT TIME : 02/05/2007 17:04 NAME : FAX TEL SER.# : 0@0L53596800 DATE,TIME 02/05 17:00 FAX NO./NAME 913372355089-10897# DURATION 00:03:35 PAGE(S) 09 RESULT OK MODE STANDARD ECM (*dr" CITY or COLLEGE STATION ,sir Plow*&Development Service 1101 Texas Avenue, P.O. Box 9960 College Station, Texas 77842 Phone 979.764.35701 Fax 979.764.3496 MEMORANDUM February 5, 2007 TO: Brett McCully, PE FROM: Crissy Hartl, Staff Planner SUBJECT: MID SOUTH BANK(SP)- Site Plan Staff reviewed the above-mentioned site plan as requested. The following page is a list of staff review comments detailing items that need to be addressed. Please address the comments and submit the following information for further staff review: One (1) revised site and landscaping plan. Easement Dedication Sheet and required documents. Please note that the Easement Dedication Sheet and necessary documents are required prior to the issuance of a building permit. If there are comments that you are not addressing with the revised site plan, please attach a letter explaining the details. if you have any questions or need additional information, please call me at 979.764.3570. Attachments: Staff review comments al-I o q:4c1 C*Or"I cd CITY OF COLLEGE STATION :�::, a" PJg»ei,.a�'DecSlnpnanc Serraer _ .. 1101 Texas Avenue, P.O. Box 9960 College Station, Texas 77842 Phone 979.764.3570 I Fax 979764.3496 MEMORANDUM February 5, 2007 TO: Brett McCully, PE FROM: Crissy Harti, Staff Planner SUBJECT: M1D SOUTH BANK (SP)- Site Plan Staff reviewed the above-mentioned site plan as requested_ The following page is a list of staff review comments detailing items that need to be addressed. Please address the comments and submit thehefollowing information for further staff review: V One (1) revised site and landscaping plan_ N 2M Easement Dedication Sheet and required documents. U. D SE's TG" � - Please note that the Easement Dedication Sheet and necessary documents are required prior to the issuance of a buildingph letter explain ng the details_If you have any git. If there re comments tat you are not durestio essin9 or need with the revised site plan please attttac additional information, please call me at 979.764.3570. Attachments: Staff review comments pc: H.E. Butt Grocery Company, PO Box 839999, San Antonio,TX 78283 James Broussard, AIA via fax#337.235.5089 Case file#07-00500020 Home of Texas A&M University . Bii, Bleyl & Associates 1722 Broadmoor Suite 210 A Project Engineering & Management Bryan, TX 77802 4 February 12, 2007 Ms. Crissy Hartl, Staff Planner Planning and Development Sevices 1101 Texas Avenue, P.O. Box 9960 College Station, Texas 77842 RE: Mid-South Bank Site Plan Comments Case #07-00500020 Dear Ms. Hartl, Following are your planning comments from the February 5 review of the referenced project. Our resolution is shown next to each comment in italics. 1. Please provide a key map of the project to identify area location. A project location map now appears on the Site Plan. 2. Provide the legal description, date of submittal, and site area it title block. The requested information has been added to the site plan. 3. Please relocate fencing and screening details, with the exception of dumpster screening, to another sheet and enlarge the site plan to a scale of 1" = 10'. Site Plan has been enlarged, and details have been moved. 4. Identify the ownership and current zoning of parcel and all abutting parcels. Ownership and zoning is now shown. 5. Provide the gross square footage of all buildings and structures and proposed use of each. Square footage of each structure and use is now shown. 6. Dimension and label all setbacks on the site plan. Dimensions have been added. 7. Please provide building elevations, color samples, and a materials list according to section 7.9 of the UDO. Approval of the elevations is required before a building permit will be issued. Separate review of the elevations will count as one round of review out of three allowed. This will be submitted separately by Architect. 8. Please identify and dimension all existing sidewalks. Existing sidewalks have been labeled and dimensioned. 9. Please add the curb and pavement detail to the site plan. Curb and pavement details appear on the Grading Plan. 10. Please provide your parking calculations on the site plan, and include what is required by ordinance and what was provided. Requested information now appears on Site Plan. 11. Per UDO Section 7.2.J. Drive-Through Facility Queuing Requirements, a minimum three queuing spaces are required from the window for an ATM and four queuing spaces are required from the teller of a bank teller lane. These Bryan Austin (979)-268-1125 Conroe (979)-260-384911 (512)-328-7878 (936)-441-7833 (512)-328-7884 Fax (936)-760-3833 Fax spaces have an area of 10' x 18.5'. Please dimension these spaces. Please dimension these spaces and verify that this requirement as well as other standards, such as drive-aisle widths, is also being met. Queuing spaces are now delineated and dimensioned on the Site Plan. 12. Per UDO Section 7.2.D. End Islands, a 180 sq. ft. island is required at the ends of every parking row. Please dimension the islands on the plan and verify that this requirement is being met. Islands are now dimensioned and square footages are shown. 13. What is your intent for sanitation service? Please see UDO Section 7.7 Solid Waste for our minimum design standards. Wally Urrutia of the Solid Waste Department was contacted. One 90 gallon trash container can be used. The enclosure is adequate for this size container. 14. Please remove all sigh details or add a note to the site plan that reads "All signs to be permitted separately". Note has been added. 15. Provide a general note that all roof and ground-mounted mechanical equipment shall be screened from view or isolated so s not to be visible from any public right-of-way or residential district within 150' of the subject lot, measured from a point five feet above grade. Such screening shall be coordinated with the building architecture and scale to maintain a unified appearance. Note has been added. Please do not hesitate to contact me with any questions, or if you require additional information. Sinc ely, Brett A. McCuII , P.E. Senior Engineer B Bleyl & Associates g� y ate s 1722 Broadmoor (X Suite 210 iiiik. A Project Engineering & Management Bryan, TX 77802 oK February 12, 2007 Mr. Josh Norton, E.I.T. Development Services City of College Station P.O. Box 9960 College Station, Texas 77842 RE: LETTER ACKNOWLEDGING CITY STANDARDS MID-SOUTH BANK, COLLEGE STATION, TEXAS Dear Mr. Norton: The purpose of this letter is to acknowledge that the construction plans for the water, sanitary sewer, streets and drainage for the referenced project, to the best of my knowledge, do not deviate from the B/CS Design Guideline Manual. I also acknowledge, to the best of my knowledge that the details provided in the construction plans are in accordance with the Bryan/College Station Standard Details. Since the detention requirements for Lot 6 and a portion of Lot 5 were satisfied as part of the overall development plan submitted for Anderson Ridge Phase IV by the H. E. Butt Grocery Company, we do not believe a drainage report is required. We are also asking that the fire flow report be waived. There is an existing fire hydrant on the southwest corner of the Mid-South site that satisfies the City's Fire Code with respect to its distance from the building, so no new infrastructure is required. Given the proximity of the elevated storage tank, we are confident that sufficient pressure exists at this existing hydrant. Please contact me if you have any questions or require any other information for your review. Sincerely, /47, , / 0,„,,,,, ,c?...d,„.., .711 et. 'eri., , evitee * '''fb*'1:ti, Brett A. c' ly, P.E. ce wisesi,� 03 P a i 1 aR 1, Senior n•meer � �' leiteeea“seeI U) :Q ,s•s G 1 1 kt°47 l Sjoris.4 -1a/ Bryan Austin (979)-268-1125 Conroe (979)-260-384911 (512)-328-7878 (936)-441-7833 (512)-328-7884 Fax (936)-760-3833 Fax -,, A r. f ; ,._ , . , I II' N i /C.:1'., Ell , ,, . , c...: ,,,,f ,,,,, r, (_:. -r-\-,-r-,, II A' \ V ; 4 A_,,,,,, . .%) ...,, A.:-I ,i., \ 7> A, ' , .. MB A l'HUFES6IONAI,EN(; N'I'',FRI NG CORPOIZATION MN '304 PIATT; ND )1'1'..`'-' • ''.1:1``'F'Af; MI LAKWETTE.LOUISIANA 70:'..f. . . ME i.X.-37 2:34,7474 • FAX II..7:i7)44-7774 www.msxtrw-iuting.t.14n: February 8, 2007 James Broussard James Broussard & Associates P.O. Box 53517 Lafayette, LA 70505-3517 Re: Midsouth Bank-College Station,TX M&E 06197.00 Dear James: We have received a copy of the City of College Station, Planning Department comments.and offer the following responses to items relative to Mechanical and Electrical: Mechanical Comments: Miscellaneous 1. Miscellaneous Item No. 1: A. Irrigation system must be protceted by either a pressure vacuum breaker,a reduced pressure principle backflow device or a double check back flow device and installed as per City Ordinance 2394. Response: Backflow preventer is shown on Drawings Sheet Ml.01 but has not been included in the specifications this will be added by addendum and noted to comply. 2. Miscellaneous hem No.2: A. All backflow devices must be installed and tested upon installation as per City Ordinance 2394. Response: This item w ill be added by addendum and will be noted to comply. Engineering Comments No. 1 3. Engineering Comments No. 1, Item No 3: A. Please illustrate proposed sanitary sewer serv:ee the sie, slope, material type. Response: Size of sanitary sewer line will be 4" as noted on Drawings Sheet M1.01 and will be connected to existing 6" sewer service from existing building to he removed. Slope of sewer line shall be as per Section 15350. Material shall be as per Section 15100. ...i SCOTTY •J BAUDOIN, P.E. .;AY" Mux, PE. RIUHAN” NI :.RP,LANC L.. 4. Eihtineering Comments No, 1. Item No 4: A. Please illustrate proposed water serv:ce line and material type. Response: Water service line vill be as per Drawing Sheet M1.01.A backflow prevention device wiil be added by addendum. Material type shall be as specified in Section 15100. 5. Engineering Comments No. 1, Item No 5: A. Please illustrate proposed location for the domestics and irrigation meter. These meters need to be located within an easement. The irrigation system will require hackflow preventer, Response: Water meters shall be located in easement which will be clarified in the addendum. Electrical Comments: Electrical Comments item No. 1: A. Developer provales temporary blanket easement for construction purposes. Response:(OwnerlDeveloper Civil) 2. Electrical Comments Item No, 2: A. Developer provides easement for electric infrastructure as installed ear electric lines (including street lights). Response: (Owner,DeveloperiCivil) General Electrical Comments: . General Electrical Comments Item No. : Developer installs eonduit per City specs and design. Response: Covered by specification, 16010-1: -Electrical installations-. 2. General Electrical Comments Item No, 2: A. Ciry will provide drawings for conduit installation, Response: Covered by specification, 16010-1: -Electrical Installations-and electrical riser on Drawings E3.0l. General Electrical Comments Item No. 3: A. Developer to intercept existing,conduit at designated transformers and extend as requtred, Response: Shown on Electrical Site Plan 111.01, 4, Gni Electrical Comments hem No,4: A. If concEiit does not exist at designated t.ransformer developer to iiii•nish and install conduit as shown on electricaay011I. Response: Shown on Electrical Site Plan E1.0:,and electrical riser on Drawing E3.0 I. 5, General Electrical Comments Item N . 5: A. Developer pours transformer:pad(s)per City specs and design. Response: Shown on electrical riser on Sheet E.3.01, 6. General Electrical Comments Item No, 6: A. Developer installs pull boxes as per City specs and design pull boxes provided by the City. Response: Shown or:electrical riser on Sheet E3.0 I . General Electrical Comments Item No, 7: A. Developer provides digital AutoCAD 2000 or later version of plan and/or site plan. E-mail to sweidixiestx.20v. ResponsutoCad drawings were e-mailed from Nati Consulting to Stmi Weido on P/5/07. 8. General Electrical Comments Item No, 8: A. Developer provides load data for project. Response: Load Summary was sent to Sam Weida and also appears on Drawings E3.01 9. General Electrical Comments Item No. 9: A. To discuss any of the above electrical comments, please contact SainWeido at 979-784-8'314. Response: Acknowledged. If you need additional information please contact our office, Sincerely, Richar . LeBlanc Electrical Project Mamager M&F,Consultinsz. Inc. •