HomeMy WebLinkAboutStaff Review 1/29/2007 2 :21 PM GWF'AX -> 512'/560254 Page 3 of 3
0A,().—
STAFF REVIEW COMMENTS NO. 1 �'
Project: MCDONALDS - LANDSCAPING (SP) —07-00500012 ��` ^
43
PLANNING
vBecause more than 25% of the existing trees were removed, the site must come into
V✓✓ compliance with the landscape ordinance. In addition to replacing the trees lost, the
parking spaces adjacent the University Drive right-of-way must be screened using 5 gallon
rubs. Please show the placement and type of shrub proposed.
Please include a legend on the site plan that states the actual size and type of each
proposed tree (each tree type should have a different symbol). Please also include the
number of points that each tree earns and the total of the points earned for the site.
1.5" -2" = 75 points
2.1" - 3.4"= 150 points
3.5" & above= 300 points
y"
Please also include the following information I calculation on the landscape plan:
"Site area = 38,580 I.f.
38,580/ 1,000 x 30= 1,157.4 landscape points required
105' feet of street frontage (excluding driveway) / 50 x 300 = 846 streetscape points
req.
. 1,157.4 + 846 = 2,003.4 total points required."
lease also include the following information on the landscape plan:
"Approximately 60 caliper inches of mature trees removed from site, _ caliper inches
Tto replace trees removed."
he trees should be located on the subject property. You have shown one tree in the
(.University Drive right-of-way.
1„,8. Based on our streetscape requirements, you are required to place one more tree along
University Drive (can be moved from rear of property).
lease show the "16" Oaks" in the rear as either existing or removed.
Is an automatic irrigation system already installed in the proposed planting areas?
■ Irrigation system must be protected by either a Pressure Vacuum Breaker, a
Reduced Pressure Principle Back Flow Device, or a Double-Check Back Flow
Device, and installed as per City Ordinance 2394.
■ All BackFlow devices must be installed and tested upon installation as per City
Ordinance 2394.
Reviewed by: Jennifer Prochazka Date: January 25, 2007
NOTE: Any changes made to the plans, that have not been requested by the City of College Station, must be
explained in your next transmittal letter and "bubbled" on your plans. Any additional changes on these
plans that have not been pointed out to the City. will constitute a completely new review. 2 of 2
JAN 29,2007 16:16 GWFAX Page 3
STAFF REVIEW COMMENTS NO. 1
Project: MCDONALDS - LANDSCAPING (SP) — 07-00500012
PLANNING
1. Because more than 25% of the existing trees were removed, the site must come into
compliance with the landscape ordinance. In addition to replacing the trees lost, the parking
spaces adjacent the University Drive right-of-way must be screened using 5 gallon shrubs.
Please show the placement and type of shrub proposed.
2. Please include a legend on the site plan that states the actual size and type of each
proposed tree (each tree type should have a different symbol). Please also include the
number of points that each tree earns and the total of the points earned for the site.
1.5" - 2" = 75 points
2.1" - 3.4" = 150 points
3.5" & above = 300 points
3. Please also include the following information / calculation on the landscape plan:
"Site area = 38,580 I.f.
38,580 / 1,000 x 30 = 1,157.4 landscape points required
105' feet of street frontage (excluding driveway) / 50 x 300 = 846 streetscape points req.
1,157.4 + 846 = 2,003.4 total points required."
4. Please also include the following information on the landscape plan:
"Approximately 60 caliper inches of mature trees removed from site, _ caliper inches
to replace trees removed."
5. The trees should be located on the subject property. You have shown one tree in the
University Drive right-of-way.
6. Based on our streetscape requirements, you are required to place one more tree along
University Drive (can be moved from rear of property).
7. Please show the "16" Oaks" in the rear as either existing or removed.
8. Is an automatic irrigation system already installed in the proposed planting areas?
• Irrigation system must be protected by either a Pressure Vacuum Breaker, a
Reduced Pressure Principle Back Flow Device, or a Double-Check Back Flow
Device, and installed as per City Ordinance 2394.
• All BackFlow devices must be installed and tested upon installation as per City
Ordinance 2394.
Reviewed by: Jennifer Prochazka Date: January 25, 2007
NOTE: Any changes made to the plans, that have not been requested by the City of College Station, must be
explained in your next transmittal letter and"bubbled"on your plans.Any additional changes on these plans
that have not been pointed out to the City,will constitute a completely new review. 2 of 2