HomeMy WebLinkAboutStaff Comments CITY OF COLLEGE STATION
Planning d Development Services
1101 Texas Avenue, P.O. Box 9960
College Station, Texas 77842
Phone 979.764.3570 / Fax 979.764.3496
MEMORANDUM
August 27, 2007
TO: Jim Easterly, via fax: 979-776-4747
FROM: Jennifer Prochazka, AICP, Senior Planner
SUBJECT: SUMMIT CROSSING MASTER PLAN
Staff reviewed the above-mentioned Master Plan as requested. This item has been scheduled
for the next available Planning and Zoning Commission meeting scheduled for September 6,
2007 at 7:00 p.m. in the City Hall Council Chambers, 1101 Texas Avenue.
The agenda and staff report can be accessed at the following web site on Monday the week of
the P&Z meeting.
http://www.cstx.gov/home/index.asp?page=2481.
If you have any questions or need additional information, please call me at 979.764.3570.
Attachments: Staff review comments
cc: The Summit Crossing, LLC, via email parvizvessaliyahoo.com
Joe Schultz, P.E., via fax: 979-764-7759
Case file #07-00500160
STAFF REVIEW COMMENTS NO. 3
Project: SUMMIT CROSSING (MDP) - 07-00500160
PLANNING
1. FYI - The master plan is reviewed as a conceptual layout only. At preliminary plat, final plat,
and site plan, the requirements of the Subdivision Regulations, B/CS Design Guidelines and
the Site Design Standards, including but not limited to stopping site distance,
driveway/street spacing, and maximum block length, will need to be addressed.
Reviewed by: Jennifer Prochazka & Josh Norton Date: August 27, 2007
s .sem_ CITY OF COLLEGE STATION
Planning d Development Services
1101 Texas Avenue,P.O. Box 9960
College Station,Texas 77842
Phone 979.764.3570 / Fax 979.764.3496
MEMORANDUM
July 27,2007
TO: Jim Easterly,via fax: 979-776-4747
FROM: Jennifer Prochazka,AICP,Senior Planner
SUBJECT: SUMMIT CROSSING MASTER PLAN
Staff reviewed the above-mentioned Master Plan as requested. The following page is a list of staff review
comments detailing items that need to be addressed. Please address all comments and re-submit the items
listed below. Once all comments are met, your project will be scheduled for a Planning & Zoning
Commission meeting.
One(1) 24"x 36"copy of the revised Master Plan;and
Sixteen (16) 11"x 17" copies of the revised Master Plan.
Upon receipt of the required documents for the Planning& Zoning meeting,your project will be considered
formally filed with the City of College Station. Please note that if all comments have not been addressed,your
project will be pulled from the scheduled Planning & Zoning Commission agenda. Your project may be
placed on a future agenda once all the revisions have been made and the appropriate fees paid. Once your
item has been scheduled for the P&Z meeting, the agenda and staff report can be accessed at the following
web site on Monday the week of the P&Z meeting.
http://www.cstx.gov/home/index.asp?page=2481.
If you have any questions or need additional information,please call me at 979.764.3570.
Attachments: Staff review comments
cc: The Summit Crossing,LLC,via email parvizvessali(a,yahoo.com
Joe Schultz,P.E.,via fax: 979-764-7759
Case file#07-00500160
•
STAFF REVIEW COMMENTS NO.2
Project: SUMMIT CROSSING (MDP) -07-00500160
PLANNING
1. Please show all street rights-of-way- as a land use. Do not include the size or dimensions of the streets.
(Repeat Comment) All street rights-of-way are required to be shown on the entire Master Plan.
2. The proposed collector roadway must align with Pamela Lane.
3. Please remove the existing water line on Harvey Road.
4. Please include the 12"water line on FM 158,as shown on the City's master plan (Repeat Comment).
Reviewed by:Jennifer Prochazka&Josh Norton Date:July 27,2007
0
(4*.iffill1111141
CITY OF COLLEGE ST.YrION
Planning dr Development Services
1101 Texas Avenue,P.O. Box 9960
College Station,Texas 77842
Phone 979.764.3570 /Fax 979.764.3496
MEMORANDUM
July 10,2007
TO: Jim Easterly,via fax: 979-776-4747
FROM: Jennifer Prochazka,AICP,Senior Planner
SUBJECT: SUMMIT CROSSING MASTER PLAN
Staff reviewed the above-mentioned Master Plan as requested. The following page is a list of staff review
comments detailing items that need to be addressed. If all comments have been addressed and the following
information submitted by Monday, July 16, 2007 at 10:00 a.m., your project will be placed on the next
available Planning and Zoning Commission meeting scheduled for August 2, 2007 at 7:00 p.m. in the City
Hall Council Chambers, 1101 Texas Avenue.
One (1) 24"x 36" copy of the revised Master Plan;and
Sixteen (16) 11"x 17"copies of the revised Master Plan.
Upon receipt of the required documents for the Planning& Zoning meeting, your project will be considered
formally filed with the City of College Station. Please note that if all comments have not been addressed,your
project will be pulled from the scheduled Planning & Zoning Commission agenda. Your project may be
placed on a future agenda once all the revisions have been made and the appropriate fees paid. Once your
item has been scheduled for the P&Z meeting, the agenda and staff report can be accessed at the following
web site on Monday the week of the P&Z meeting.
http://www.cstx.gov/home/index.asp?page=2481.
If you have any questions or need additional information,please call me at 979.764.3570.
Attachments: Staff review comments
cc: The Summit Crossing,LLC,via email parvizvessali(a,yahoo.com
Joe Schultz,P.E.,via fax: 979-764-7759
Case file#07-00500160
r)
STAFF REVIEW COMMENTS NO. 1
Project: SUMMIT CROSSING (MDP) - 07-00500160
PLANNING
1. Please include utilities shown on the City's master utility plans — this includes a 12" water
line on FM 158 and a 12" waterline along each of the proposed thoroughfares.
2. Please show Harvey Road and F.M. 158 designations on the Thoroughfare Plan.
3. The proposed collector roadway must align with either Pamela Lane or Marcy Lane.
4. The Master Plan must be drawn at a scale of 100' per inch or larger. If this requires
additional sheets, an index sheet must be included at 500' per inch scale or larger.
5. Is there any floodplain or floodway on the property?
6. Please show all street rights-of-way (as a land use). Do not include the size or dimensions
of the streets.
7. Please remove the rights-of-way widths from the proposed thoroughfares.
8. Please remove utility easements.
9. Please tie to College Station monument or known platted point.
10. The metes & bounds description provided does not close.
Reviewed by: Jennifer Prochazka & Josh Norton Date: July 9, 2007
SANITATION
1. Sanitation is ok with this project.
Reviewed by: Wally Urrutia Date: July 3, 2007
ELECTRICAL COMMENTS REQUIRING IMMEDIATE ATTENTION
1. Developer provides temporary blanket easement for construction purposes.
2. Developer provides easements for electric infrastructure as installed for electric lines
(including street lights).
GENERAL ELECTRICAL COMMENTS
1. Developer installs conduit per City specs and design.
2. City will provide drawings for conduit installation.
3. Developer provides 30' of rigid or IMC conduit for riser poles. City installs riser.
4. Developer to intercept existing conduit at designated transformers and extend as required.
5. If conduit does not exist at designated transformer, developer to furnish and install conduit
as shown on electrical layout.
6. Developer pours transformer pad(s) per City specs and design.
7. Developer installs pull boxes and secondary pedestals as per City specs and design (pull
boxes and secondary pedestals provided by the City).
8. Developer provides digital AutoCAD 2000 or later version of plat and/or site plan. Email to:
sweido@cstx.gov.
9. Developer provides load data for project.
10. To discuss any of the above electrical comments please contact Sam Weido at
979.764.6314.
Reviewed by: Sam Weido Date: 7-6-07
RESPONSE TO
STAFF REVIEW COMMENTS NO. 1
Project: SUMMIT CROSSING (MDP) - 07-00500160
PLANNING
1. Please include utilities shown on the City's master utility plans — this includes a 12" water line on
FM 158 and a 12"waterline along each of the proposed thoroughfares.
The 12"waterlines have been added.
2. Please show Harvey Road and F.M. 158 designations on the Thoroughfare Plan.
These designations have been added.
3. The proposed collector roadway must align with either Pamela Lane or Marcy Lane.
The roadway has been aligned with Marcy Lane
4. The Master Plan must be drawn at a scale of 100' per inch or larger. If this requires additional
sheets, an index sheet must be included at 500' per inch scale or larger.
The Master Plan has an index cover sheet and additional sheets at 1"=100'
5. Is there any floodplain or floodway on the property?
As stated in the note on the Master Plan, there is no FEMA designated floodplain or floodway.
6. Please show all street rights-of-way (as a land use). Do not include the size or dimensions of the
streets.
Street right-of-ways have been shown for some of the residential area. Layout of streets in the
remaining areas have not been determined at this time.
7. Please remove the rights-of-way widths from the proposed thoroughfares.
Rights-of-ways widths have been removed.
8. Please remove utility easements.
The utility easements have been removed.
9. Please tie to College Station monument or known platted point.
The boundary has been tied to a known platted point.
10. The metes &bounds description provided does not close.
The boundary has been adjusted so it closets.. q t+