Loading...
HomeMy WebLinkAboutStaff Review STAFF REVIEW COMMENTS NO. 3 Project: BIRD POND ESTATES (PP) - 06-00500265 ADDRESSING 1. Change Green Jay Drive to Green Jay Court 2. Change Yellow Tanager Drive to Yellow Tanager Court Reviewed by: Mandi Alford Date: January 3, 2007 MAPPING 1. Does not close 2. Enlarge calls so as to be clearly legible 3. Check to make sure calls do not overlap other text or graphics so as to be clearly legible 4. Consolidate duplicate bearings and sum related distances Reviewed by: Sven Griffin Date: January 3, 2007 ENGINEERING COMMENTS NO. 2 1. Please clearly label the PUEs. The yellow line does not show up on our copy. It may be appropriate to dimension and label the PUEs throughout. 2. Please provide the 20-ft PUE, shared between Lot 1, Phase 4, Block 5, and it surrounding lots. 3. Please correct the temporary turn around easement, as the 40-ft should be labeled as a radius dimension. 4. Please dimension the actual intended drainage easement area between Lot 13 and 14 of Phase 1, Block 2. 5. Please dimension and label the easement needed to loop the water main back to Rock Prairie as a proposed easement. If a PUE exists please provide volume and page. Reviewed by: Josh Norton Date: January 5, 2007 STAFF REVIEW COMMENTS NO. 2 Project: BIRD POND ESTATES (PP)- 06-00500265 PLANNING/ENGINEERING ell 1. Please clearly depict the boundaries of the parent tract. X2. As previously noted in review comments #1, the metes and bounds do not close. Please � resubmit a metes and bounds description that closes. . Please note on the plat where the proposed cul-de-sacs abut adjoining properties for future street extension "for future street extension" at each location. This includes Phase 4, Block 5, Lot 1. /. Please note on the plat the all Public Utility Easements (PUE's) that were requested for the rear of all lots that do not but up to a right-of-way or that back up to other lots, as well as the 16-foot PUE along the streets that was requested from BTU. / Please clearly define existing rights-of-way for Bird Pond and for Frost Drive to clarify width of water line coverage alignment. "? ,--6: As previously requested on review comments#1, please provide street names on the plat(See Patrick Corley's comments below). 2 ,---7. As previously requested, please provide the appropriate documentation for the abandonment of the Oil/Gas Well. /8' Please label the size of all of the proposed "FW" mains. 7. Please note the right-of-way dedication along Bird Pond on the plat. Reviewed by: Jennifer Reeves/Alan Gibbs Date: December 19, 2006 BRAZOS COUNTY 911 Patrick C. Corley<pcorley@bc911.org> 12/19/2006 2:57 PM Here is the breakdown on the proposed names for Bird Pond Estates... ACCEPTABLE: Canvasback Cir Wood Duck Way Redhead Run Yellow Tanager Cir Green Jay Cir Purple Finch Dr Tree Swallow Dr Catbird Cir Western Sparrow Cir UNACCEPTABLE: Pintail Way Mallard Run Teal Way Blue Heron Way Song Sparrow Cir -Patrick NOTE: Any changes made to the plans,that have not been requested by the City of College Station,must be explained in your next transmittal letter and `bubbled"on your plans.Any additional changes on these plans that have not been pointed out to the City,will constitute a completely new review. 2 of 2 STAFF REVIEW COMMENTS NO. 1 Project: BIRD POND ESTATES (PP) - 06-00500265 PLANNING 1. The metes and bounds description does not close. 2. The Preliminary Plat needs to reflect the entire parent tract (configuration the property was in when it came into the City of College Station's E.T.J., which was 1977) 3. A mylar of the approved Master Plan is required to be turned in prior to the Preliminary Plat going forward. 4. Please provide street names (Street names will be approved through Brazos County 911). 5. The most northern entrance to the subdivision is exceeding the 1500 foot block length requirement. A variance request will need to be submitted or the block length will need to be adjusted to meet Section 12-K.2 Block Length in the Subdivision Regulations. 6. Section 12-1.3 Relation to Adjoining Street Systems in the Subdivision Regulations. This will require two stub outs to the adjoining property to the south, one to the east and two to the north. (Rick- Please call for clarification) 7. The southern entrance to the subdivision will need to line up with Britt Rice driveway or meet opposite adjacent spacing in Section 7.3.g of the Unified Development Ordinance. 8. Lot 1 of Block 2, Phase 1 needs to be labeled as Common Area and Drainage Basin and not identified as a lot. 9. Please identify rear lot lines for lots 5 and 9 of Phase 1, Block Two in reference to the Floodplains and Streams area. It is unclear where these property lines are in comparison to the zoning boundary. 10. Block Five, Phase Four will need to be identified with a lot number. 11. Please provide a 20-foot public utility easement along the rear of all lots that do not back up to a right-of-way. In areas where lots back up to other lots within this subdivision a 10-foot PUE may be dedicated from each lot. Additional PUE should also be provided for the "FW" main where needed. 12. Please remove building setbacks from the plat, as setbacks are subject to change through U.D.O. amendments from time to time. 13. Please provide the appropriate documentation for the abandonment of the Oil/Gas Well. Please show the location of the Oil/Gas Wells on the Preliminary Plat. 14. The first stub out to the right in Phase 1 exceeds 100-feet. A temporary turn around will be required or shorten the length to 100-feet. Reviewed by: Jennifer Reeves Date: December 11, 2006 ENGINEERING COMMENTS NO. 1 1. Please illustrate easements that the proposed "FW" water main will be located in. This should include the easements used to make the off site water main connections for looping. 2. The "FW" main should be extended down all ROWs. 3. Please label the size of the proposed "FW" main. 4. Where will the detention ponds for this subdivision be located? 5. FYI — Point discharge from a detention basin may require an off site agreement from adjacent property owners. Reviewed by: Josh Norton Date: December 11, 2006 ELECTRICAL COMMENTS REQUIRING IMMEDIATE ATTENTION 1. No Comments,Outside our electric service territory. 2. To discuss any of the above electrical comments,please contact Tony Michalsky at 979.764.3438 . Reviewed by: Tony Michalsky Date: December 11,2006 BTU 1. 16' PUE along the street 2. 20' PUE centered along the interior lot lines. 3. 20' PUE along the back of all lots that are along the outer perimeter of the subdivision. Reviewed by: Randy Trimble Date: December 11, 2006