Loading...
HomeMy WebLinkAboutStaff Report STAFF REPORT Project Manager: Lindsay Boyer, Staff Planner Report Date: January 4, 2007 Email: lboyer@cstx.gov Meeting Date: January 4, 2007 Project Number: 06-00500261 Item: Presentation, possible action, and discussion on a Variance Request to Section 8-J, Blocks of the Subdivision Regulations and a presentation, possible action, and discussion on a Preliminary Plat for Tower Point Subdivision consisting of 23 lots on 128.28 acres located at 951 William D. Fitch Parkway in the general vicinity of the northwest corner of the intersection of William D. Fitch Parkway and State Highway 6. Applicant: Chuck Ellison, agent for the owner. Staff Recommendations: If the variance is approved, staff recommends approval of the preliminary plat with the condition that the attached Staff Review Comments are addressed. Item Summary: The proposed plat is in preparation of commercial development on the site. This area is under a Master Plan approved in 1997, vesting the project under 1997 Subdivision Regulations under the Texas Local Government Code. The plat proposes the development of the property in 9 phases. Section 8-J of the Subdivision Regulations require that blocks shall be no longer than 800 feet in non-residential areas. The applicant is requesting a variance to this section. The applicant is requesting a variance to block length requirement in 4 places: 1. The block length along the east side Lots 11 and 2, Block 3 — 2645.4 feet 2. The block length along the west side of Lot 11, Block 3 — 1208.9 feet 3. The block length along the southern sides of Lots 7-9, Block 3 — 1086.4 feet 4. The block length along the northern side of Lots 2 and 3, Block 5 — 810.4 feet In considering a variance, the Planning and Zoning Commission should make the following findings: 1. That there are special circumstances or conditions affecting the land involved such that strict application of the provisions of this chapter will deprive the applicant of the reasonable use of his land; 2. That the variance is necessary for the preservation and enjoyment of a substantial property right of the applicant; 3. That the granting of the variance will not be detrimental to the public health, safety, or welfare, or injurious to other property in the area, or to the City in administering this chapter; and 4. That the granting of the variance will not have the effect of preventing the orderly subdivision of other land in the area in accordance with the provisions of this chapter. Comprehensive Plan Considerations: The Comprehensive Land Use Plan identifies this area as Retail Regional, and the property has frontage on State Highway 6 and William D. Fitch Parkway, both designated highways on the Thoroughfare Plan. The property also includes the extension of Arrington Road, a major collector, through the property which is currently a project in the Capital Improvement Budget. Additionally, two lots have frontage on Decatur Drive, another major collector. The properties will have access from all four roads. The access easements identified on the plat will be the only driveways granted on TxDOT right-of-way. This plat is in compliance with the approved Master Plan and the 1997 Subdivision Regulations. Item Background: The subject property was annexed in 1983 and subsequently zoned A-O, Agricultural Open. The majority of the property was rezoned in 2001 to C-1, General Commercial. The Spring Creek property located along Decatur Drive was rezoned to C-1, General Commercial and A-P, Administrative Professional in 2005. The OV, Corridor Overlay was also applied to a majority of the property in 2006. Budgetary & Financial Summary: N/A Related Advisory Board Recommendations: N/A Commission Action Options: The Commission has final authority over the preliminary plat. The options regarding the preliminary plat are: ■ Approval ■ Denial INFRASTRUCTURE AND FACILITIES Water required for plat: There are existing water mains along State Highway 6 and State Highway 40. A public water main is required to be extended to all lots. Water Service: Domestic water service and fire protection to be extended to all structures as needed. Sewer required for plat: There are existing sanitary sewer trunk lines through the property. A public sewer main is required to be extended to all lots as shown on Plat. Sewer Service: To be provided to all building plots as required from public line. Street(s) required for plat: Arrington Road and Decatur Road are Major Collectors on the City's Thoroughfare Plan and are required for platting. The City has a Capital Improvement Project to construct Arrington and Decatur Roads. Streets/Access: To comply with the driveway spacing requirements, shared access easements are proposed for dedication from Arrington Road, Decatur Road, State Highway 6, and State Highway 40. Internal access easements are also proposed for circulation and access to additional lots. Off-site Easements required for plat: None at this time. Drainage: There is an existing regional detention facility. Flood Plain: FEMA designated floodplain for Spring Creek is located on this property. Finished Floor elevations have been determined for the lots impacted by the floodplain. Oversize request: None at this time. Impact Fees: The majority of the property is located in the Spring Creek Sewer Impact Fee Area (97-01). Currently, the Impact Fee for this area is $349.55 per Living Unit Equivalent. Impact Fees are due at time of Building Permit. Parkland Dedication Fees: None. Supporting Materials: 1. Small Area Map (SAM) and Aerial Map 2. Application 3. Copy of Preliminary Plat (provided in packet) 4. Variance Request Letter 5. Staff Review Comments