TO: City of College Station - Development Services DATE: October 16, 2006
PROJECT NO.:
PROJECT NAME: Gateway Phase 4
Final Plat
ATTENTION: Bridgette George REFERENCE:
WE TRANSMIT: THE FOLLOWING: FOR:
❑ Under Separate Cover ❑ Prints ❑ Your Review&Approval
✓ Enclosed 0 Copies ✓ Your Review & Comment
0 Originals ✓Your Review& Distribution
VIA: ✓ Plat ❑ Your Review, Revision & Return
❑ Mail 0 Field Notes 0 Your Signature & Return
✓ Messenger 0 Plans 0 Your File and/or Use
O Federal Express 0 Report 0 For Filing at the Courthouse
O Lone Star Overnight ❑ Estimate
❑ UPS ❑ Cut Sheets 0 As Requested By:
❑ Special Courier ❑ Computer Printout ❑ Please Acknowledge Receipt of
O Picked Up By Your Office ❑ File Enclosures
0 Contract ❑ Please Return Enclosures To
❑ Other- Invoice ❑ Copies Of This Letter Of Transmittal
Sent To:
NO. DESCRIPTION
14 Final Plat
1 Application + Check List
1 $1055.00 check ($400.00 Plat Application Fee, If Enclosures Are Not As Noted
$600.00 Infrastructure Insp. Fee* Please Notify Us At Once.
*Please Note: Infrastructure to the lot
is currently under Construction
This Fee is for the Site Infrastructure
which will be submitted as part of the
Signed: Fred Pai' - .E.
site plans.
$55.00 County Filing Fee
1 Tax Certificate / �!
1
rw • 'J
KLING ENGINEERING & SURVEYING
Consulting Engineers• Land Surveyors
4101 Texas Avenue, Suite A P.O. Box 4234
Bryan, Texas 77802 Tel. 979/846-6212 Bryan, Texas 77805
Fax 979/846-8252
TO: City of College Station- Development Services DATE: November 20, 2006
PROJECT NO.:
PROJECT NAME: Gateway Phase 4
Site Plans + Public Infrastructure Plans
ATTENTION: Bridgette George REFERENCE:
WE TRANSMIT: THE FOLLOWING: FOR:
❑ Under Separate Cover 0 Prints 0 Your Review&Approval
✓ Enclosed 0 Copies ✓Your Review& Comment
❑ Originals ✓Your Review& Distribution
VIA: 0 Plat 0 Your Review, Revision & Return
❑ Mail ❑ Field Notes 0 Your Signature & Return
✓ Messenger ✓Plans 0 Your File and/or Use
O Federal Express ✓ Report 0 For Filing at the Courthouse
❑ Lone Star Overnight ✓ Estimate
❑ UPS 0 Cut Sheets 0 As Requested By:
O Special Courier 0 Computer Printout 0 Please Acknowledge Receipt of
❑ Picked Up By Your Office 0 File Enclosures
❑ Contract 0 Please Return Enclosures To
❑ Other-Invoice 0 Copies Of This Letter Of Transmittal
Sent To:
NO. DESCRIPTION
1 Site Plan Application
1 $200.00 Site Plan Application Fee
1 $200.00 Development Permit Application Fee, If Enclosures Are Not As Noted
($600.00 Infrastructure Fee Previously Submitted) Please Notify Us At Once.
12 Copies of Site Plans including Public Infrastructure
1 Landscape & Irrigation Plan
2 Engineer's Estimate for Public Infrastructure
2 Waterline Design Report
2 Sanitary Sewer Design Report Signed: FredZnin ' E.
Grrifi
CITY OF COLLEGE STATION
January 19,2007
David Scarmardo,President
Brazos Gateway Place Development,Ltd.
1289 North Harvey Mitchell Parkway
College Station,Texas 77803
Re: Gateway Phases 2 and 4 Subdivision–Fire Access
Mr. Scarmardo,
This letter follows our meeting regarding the subject fire access road requirement where
we are proposing an alternative to help facilitate the continued progress of your
development and cover the related health and safety concerns.
Currently,there are approximately 124un-sprinkled,multi-family dwelling units in -{Deleted:o
Gateway Villas located in Gateway Phase 2 Subdivision with only a single point for
emergency vehicular traffic. Exceeding 100 un-sprinkled,multi-family dwelling units
requires a second,remote fire access road. The units were constructed pursuant to
•permits issued by the City. c\foW Srk pP 4)(4 oh� 1-16
With specific regard to the secondary fire access road,a Development Permit can be
issued to allow full Site Plan construction to begin as well as Building Permit to be issued
on Phase 4,provided that you:
GoL,4wS1111 1
1. Construct a 26 ft wide fire access road with adequate turning radii for ladder fire ----Deleted:Provide complete engineered
truck. The pavement section should consist of a minimum of Semi–Permanent construction plans acceptable to the City
for the construction of
All-Weather Surface consisting of six inches(6")of limestone base Jt is common_ Deleted:with one-course seal coat as
to create these temporary fire roads using rock only. If the semi-permanent specified in the Texas Department of
surface is used,the six-inch(6")curb is not required,and these areas must be Transportation Standard Specifications
for Construction of Highways,Streets
gated or protected from public usage and signed for emergency access only. and Bridges,1993 Edition,Item 316.
aS �f
2. Provide an engineer'srcertification that the fire access road and underlying berm is
structurally adequate to maintain a 75,000 lb fire truck. It is suggested to have a
geotechnical analysis of the soils and the existing or required compaction effort', ,�.t�
necessary to achieve this. ` � 4 FiK '�-,.�'�I Lr` kheose
kat 4-0 �e wv '�G Pp� �� !F 1 g4-s .e "' Liv vp) 0 I L,'10 �1'
,Unnecessary if we build it s. a co . ' 'on to�receiving certificates of occupancy. --- Deleted:Provide and Engineer's f
Estimate for all associated construction !r
costs of the fire access road.
a^_Unnecessary r rsuant to comment above.
Formatted
J Deleted:<#>Provide an Unconditional
This wil equire us topr:sare a siteplan that will be c', ged as soon as we w irk on Letter of Credit acceptable to the City for
the newest s,ase recent approved as a comp plan amendm- • This is an 9-- sense and
the amount provided on the Engineer's
0 Estimate: ¶
an approval p .-•• at adds nothing to the health and safety oft e ci izenst ¶
� '„ <#>in accordance with the standard
Note that full Building Permits�always require the associated waterlines/hydrants be Letter of Credit form(attached),¶
`/ 9 constructed,accepted and active and that there is adequate drive surface for fire trucks. ', ',0, <#>from a local bank,¶
Slab only permits may be considered by the Building Official prior to full Building ', with an expiration date,not beyond July
, ,,' 1,2007
Permit to also aid in project scheduling. r Formatted:Bullets and Numbering
„'
When the additional phase of Gateway Villas (adjacent to the detention pond) is \\l Formatted
constructed,this Semi-Permanent All-Weather Surface fire access drive must be removed Deleted:Provide the associated Site
Plan modifications acceptable to the City
or reworked to meet the Permanent All-Weather Pavement standards including curbing , to the existing Gateway Villas Site Plan
and either asphalt or concrete. , (i.e.number of parking spaces,required
i end islands,relocated dumpsters,revised
landscaping,etc.)
• ally, due to the a socia -d health and safety oncern .ssociated wit fire acc- s, theDeleted;¶
C ificates of Occ saucy fo the future buil.' gs in Gate ay Phase 4 'ill not be i ed
unt the subject fir access roa,' construction.s complete an. , ceptab - to the City. -- Deleted:If the fire access is not
• constructed within the timeframe allotted
Pleas let us kno how you wou e t. = oceed. on the associated Letter of Credit and the
City has to draw on the surety,any
Best Regards, related Certificates of Occupancy will be
held until the City is able to complete
construction of the fire access.¶
XXXXX
XXXXX
Attachments
Cc: xxxxx
jlaxiL r,1 . 4
-,aZ& sS oe wtw ✓ �� u-n n DP )55062
-- 51,W DefI /QJ
-
51,kgo .tet, (SS vpv
\/ No Comics-rcg LS Arzfrivo
14 -
— c hs — NIA- r3Utbonito P64/�
tib,- et# V1,U6 6a4:4
5LW v3S
CITY OF COLLEGE STATION
January 19, 2007
David Scarmardo, President
Brazos Gateway Place Developm nt, Ltd. �-
1289 North Harvey Mitchell Park ay
College Station, Texas 77803
Re: Gateway Phases 2 and 4 S bdivisio Fire Access
Mr. Scarmardo,
This letter follows our meeting regarding the subject fire access road requirement where
we are proposing an alternative to help facilitate the continued progress of your
development and cover the related health and safety concerns.
Currently, there are approximately 120 un-sprinkled, multi-family dwelling units in
Gateway Villas located in Gateway Phase 2 Subdivision with only a single point for
emergency vehicular traffic. Exceeding 100 un-sprinkled, multi-family dwelling units
requires a second, remote fire access road.
With specific regard to the secondary fire access road, a Development Permit can be
issued to allow full Site Plan construction to begin as well as Building Permit to be
issued,provided that you:
. Provide complete engineered construction plans acceptable to the City for the
con - tion of a 26 ft wide fire access road with adequate turning radii for ladder
fire truck. •.vement section should consist of a minimum of Semi—
Permanent All-Weat - - face consisting of six inches (6") of limestone base
with one-course seal coat as spe • -• in the Texas Department of Transportation
Standard Specifications for Construction • - '.hways, Streets and Bridges, 1993
Edition, Item 316. If the semi-permanent surface is • -• the six-inch(6") curb is
not required, and these areas must be gated or protected from •. • 'c usage and
signed for emergency access only.
604,4 Iou*
2. Provide an engineer's(certification that the fire access road and underlying berm is
structurally adequate to maintain a 75,000 lb fire truck. It is suggested to have a
geotechnical analysis of the soils and the existing or requireyk compaction effort
necessary to achieve this. cl\rt NuM'Swkll o a,tL ' .
. ' ovide and Engineer's _ ' a e for all associated construction .- . •f the fire
acces .
4. ' •vide an Unconditional Letter of Credit acceptable to the City for the amount
provi•e• : • he Engineer's Estimate:
a. in accordance wit .ndard Letter of Credit form (attached),
b. from a local bank,
c. with an expiration date, not beyond July 1, 201 .
5. ' ovide the associated Site Plan modifications ace- • - : - - ' to the
exists . - - - .a Villas Site Plan ' - - . .er of parking spaces, requ -• end
islands, relocated dumpsters, revised landscaping, etc.)
q,k, 4 wgAA �S
\AA\ Ft
Note that full Building Permitsftuver require the'associated waterlines/hydrants be
constructed, accepted and active and that there is adequate drive surface for fire trucks.
Slab only permits may be considered by the Building Official prior to full Building
Permit to also aid in project scheduling. .
When the additional phase of Gateway Villas (adjacent to the detention pond) is
constructed, this Semi-Permanent All-Weather Surface fire access drive must be removed
or reworked to meet the Permanent All-Weather Pavement standards including curbing
and either asphalt or concrete.
inally, due to t - asso '• ed health and safet once sociated with fire acce _, e
C. ificates of ccupancy fo he future bui .ings in Gatewa 'hase 4 will no se issued
unti •e s . ect fire access roa. .• • •• . on is complete and a :- . ab - • . If
.•e fire access is not construct-e ithin the ti -frame allotted on the a ciated Letter
Cr- 't and the City has to t aw on the surety, an elated Certifica of Occupancy will
be hel. ntil the City i . .le to complete construction . •- fir ccess.
Please let us know how you would like to proceed.
Best Regards,
xxxxx
Xxxxx
Attachments
Cc: xxxxx
From: Alan Gibbs
To: Childers, Terry; Hurt, Eric
Date: 1/19/2007 5:23:38 PM
Subject: Gateway Fire Access
Terry/Eric,
Attached is my draft letter and our LOC form. I was not certain how to have them sign or confirm they
agree to all terms?
Alan Gibbs, P.E.
City of College Station
Sr. Asst. City Engineer, Public Works
Additional Site Plan Revisions
1 . Majority of units are going to be constructed as 3 bedroom units. For each
building with 5 & 6 units, 2 of them will be 4 bedroom units. Totals as follows:
24 - 4 Bedroom Units; 54 - 3 Bedroom Units - Utility Demands & Parking
Analysis were adjusted accordingly.
The owner/developer has been working with Fire Services to obtain an acceptable
secondary fire access to Gateway Phase 2. I have faxed the agreements between Phase 1
& Phase 2 property owners/managers regarding the secondary fire access to Phase 2 to
Alan (12/01/06).
Parkland Dedication Fee prior to building permit - Acknowledged
Easement Dedication Sheet(s) & required documents were previously submitted with the
Final Plat.
Upon this final review of the site plan, I would like to be issued a development permit for
earthwork & utility construction by December 11, 2006.
Thanks.
CITY OF COLLEGE STATION ...
max...,
Plasms 6 Der elopment Services
1101 Texas Avenue,P.O.Box 9960
College Station,Texas 77842
Phone 979.764.3570 / Fax 979.764.3496
MEMORANDUM
November 27,2006
TO: David Scarmardo,Brazos Gateway Place Development,Ltd.via fax# 979.822.1763
FROM: Crissy Hartl,Staff Planner
SUBJECT: GATEWAY PH 4 (SP)- Site Plan
Staff reviewed the above-mentioned site plan as requested. The following page is a list of staff review
comments detailing items that need to be addressed. Please address the comments and submit the following
information for further staff review:
One (1) revised site and landscaping plan.
$Parkland Dedication fees prior to issuance of a building permit.
Easement Dedication Sheet and required documents (as required).
Please note that the Easement Dedication Sheet and necessary documents are required prior to the issuance
of a building permit. If there are comments that you are not addressing with the revised site plan, please
attach a letter explaining the details. If you have any questions or need additional information,please call me
at 979.764.3570.
Attachments: Staff review comments
cc: Kling Engineering&Surveying via fax# 979.846.8252
Case file#06-00500254
Home of Texas A&M University
TRANSMISSION VERIFICATION REPORT
TIME : 11/27/2006 17:09
NAME .
FAX .
TEL .
SER. # : 000L5J596800
DATE,TIME 11/27 17: 08
FAX NO./NAME 98221763
DURATION 00: 00: 23
PAGE(S) 02
RESULT OK
MODE STANDARD
ECM
1P11;11500r111111
4 1# ! f0!1111Ipp�ip.�k, CITY OF COLLEGE STATION Aoggai�t{1414.
PZ 1��?� i
1rr& li1$!{$18 g1a '®;Bt:hrFxt nni sg d'Development Services aan' nz le»1aam;inv+C>zsmkAl•
tang&gym' _ ,.r. mM,rostrii'Ia'"
1101 Texas Avenue,P.O. Box 9960
College Station,Texas 77842
Phone 979.764.3570 / Fax 979.764.3496
MEMORANDUM
•
November 27,2006
TO: David Scarmardo,Brazos Gateway Place Development,Ltd.via fax #979.822.1763
FROM: Crissy Hard, Staff Planner
SUBJECT: GATEWAY PH 4 (SP)- Site Plan
Staff reviewed the above-mentioned site plan as requested. The following page is a list of staff review
comments detailing items that need to be addressed. Please address the comments and submit the following
information for further staff review:
One (1)revised site and landscaping plan.
$ Parkland Dedication fees prior to issuance of a building permit.
Easement Dedication Sheet and required documents (as required).
Please note that the Easement Dedication Sheet and necessary documents are required prior to the issuance
of a building permit. If there are comments that you are not addressing with the revised site plan, please
attach a letter explaining the details. If you have any questions or need additional information, please call me
at 979.764.3570.
TRANSMISSION VERIFICATION REPORT
TIME : 11/27/2066 17: 10
NAME .
FAX .
TEL .
SER. # : 868L5J596868
DATE,TIME 11/27 17: 69
FAX NO./NAME 98468252
DURATION 88:88: 22
PAGE(S) 02
RESULT OK
MODE STANDARD
ECM
i#ItslbPE�311;I„ D' 11; CITY OF CoLI,EGr STATION
�;.� rats!
i�S'�IFiI
erns n ,r� ,p,.>� Planning d'Devele prneret Services ,a ,.,.;
, ,{�:dti�s.•n�t0.
1101 Texas Avenue,P.O. Box 9960
College Station,Texas 77842
Phone 979.764.3570 / Fax 979.764.3496
MEMORANDUM
November 27,2006
TO: David Scarmardo,Brazos Gateway Place Development,Ltd.via fax#979.822.1763
FROM: Crissy Hard,Staff Planner
SUBJECT: GATEWAY PH 4 (SP)- Site Plan
_ .. --
Staff reviewed the above-mentioned site plan as requested. The following page is a list of staff review
comments detailing items that need to be addressed. Please address the comments and submit the following
information for further staff review.
One (1)revised site and landscaping plan.
$Parkland Dedication fees prior to issuance of a building permit.
Easement Dedication Sheet and required documents (as required).
Please note that the Easement Dedication Sheet and necessary documents are required prior to the issuance
of a building permit. If there are comments that you are not addressing with the revised site plan, please
attach a letter explaining the details. If you have any questions or need additional information, please call me
at 979.764.3570.
zq
(11:*1,1144
CITY OF COLLEGE STATION
February 1, 2007
David Scarmardo, President
Brazos Gateway Place Development, Ltd.
1289 North Harvey Mitchell Parkway
College Station, Texas 77803
Re: Gateway Phases 2 and 4 Subdivision—Fire Access
Mr. Scarmardo,
This letter follows our meeting regarding the subject fire access road requirement where
we are proposing an alternative to help facilitate the continued progress of your
development and cover the related health and safety concerns.
Currently, there are 124 un-sprinkled, multi-family dwelling units in Gateway Villas
located in Gateway Phase 2 Subdivision with only a single point of pedestrian and
emergency vehicular traffic. Exceeding 100 un-sprinkled, multi-family dwelling units
requires a second remote fire access road.
Based on our discussions, the City will now issue Development Permits for full Site Plan
on Phase 4 and to construct the secondary fire access to Phase 2. Additionally, the City
will issue slab only permits for Phase 4. The secondary fire access will also serve a
future phase of Villas north of the detention pond referred to as Phase 5.
Full Building Permits for Phase 4 may be issued, provided that you:
1. Construct a 26 ft wide fire access road with adequate turning radii for ladder fire
truck. In general, this pavement should be constructed to a semi-permanent
standard. The Fire Marshall must acknowledge the construction is adequate, and
he will allow a temporary limestone rock surface understanding that the road will
have asphalt placed with Phase 5. If the semi-permanent surface is used, the six-
inch curb is not required, and these areas must be gated or protected from public
usage and signed for emergency access only.
2. Provide an engineer's as-built certification that the fire access road and
underlying berm is structurally adequate to maintain a 75,000 lb fire truck. It is
suggested to have a geotechnical analysis of the soils and the existing or required
compaction effort necessary to achieve this.
3. Acknowledge that future Site Plan modifications to Phase 2 will be necessary to
the existing Gateway Villas (Phase 2) Site Plan (i.e. number of parking spaces,
required end islands, relocated dumpsters, revised landscaping, etc.). The
modified Site Plan for Phase 2 will be required with the Phase 5 Site Plan and the
associated Phase 2 site improvements will be required for Phase 5 Certificate of
Occupancy. Additionally, when Phase 5 is constructed, this Semi-Permanent All-
Weather Surface fire access drive must be removed or reworked to meet the
Permanent All-Weather Pavement standards including curbing and either asphalt
or concrete.
Note that full Building Permits always require the associated waterlines/hydrants be
constructed, accepted and active and that there is adequate drive surface for fire trucks.
Slab only permits may be considered by the Building Official prior to full Building
Permit to also aid in project scheduling.
Please let us know how you would like to proceed.
Best Regards, •
Alan Gibbs, P.E.
Sr. Asst. City Engineer
Cc: Chuck Ellison
Terry Childers
Eric Hurt
Lance Simms
Chris Haver