Loading...
HomeMy WebLinkAboutStaff Comments Cifi g I (*e."44114 CITY OF COLLEGE S'1AI'ION Planning d'Development Services 1101 Texas Avenue, P.O. Box 9960 College Station, Texas 77842 Phone 979.764.3570 / Fax 979.764.3496 MEMORANDUM August 10, 2007 TO: Steve Arden, Edelweiss Gartens Venture, via fax 979.846.0652 " FROM: Bridgette George, Development Coordinator SUBJECT: Edelweiss Gartens PP Ph. 11 and 13 Attached are comments for this project from our Electrical Division. Please address the comments and include those changes on your next submittal. If you have any questions or need additional information, please call me at 764.3570 or Sam Weido at 764.6314. Attachments: Staff review comments cc: Mike McClure, McClure and Browne, via fax 979.693.2554 ✓ Case file #07-00500181 ELECTRICAL COMMENTS REQUIRING IMMEDIATE ATTENTION 1. Developer provides temporary blanket easement for construction purposes. 2. Developer provides easements for electric infrastructure as installed for electric lines (including street lights). 3. The following easements will be required: > 5' PUE Block 24 Lot 11 adjacent to Lot 10 y 15' PUE Block 24 Lots 14 & 15. 7.5' in each lot. 5' PUE Block 24 Lot 16 adjacent to Lot 17 • 15' PUE Block 24 Lots 22 & 23. 7.5' in each lot. • 5' PUE Block 24 Lot 28 adjacent to Lot 27. • 15' PUE Block 23 Lots 14 & 15. 7.5' in each Lot. • 5' PUE Block 23 Lot 17 adjacent to Lot 16. • 15' PUE Block 23 Lots 22 & 23. 7.5' in each lot. • 5' PUE Block 22 Lot 19 adjacent to Lot 18. • 5' PUE Block 22 Lot 24 adjacent to Lot 23. • 5' PUE Block 22 Lot 29 adjacent to Lot 28. GENERAL ELECTRICAL COMMENTS 1. Developer installs conduit per City specs and design. 2. City will provide drawings for conduit installation. 3. Developer provides 30' of rigid or IMC conduit for riser poles. City installs riser. 4. Developer to intercept existing conduit at designated transformers and extend as required. 5. If conduit does not exist at designated transformer, developer to furnish and install conduit as shown on electrical layout. 6. Developer pours transformer pad(s) per City specs and design. 7. Developer installs pull boxes and secondary pedestals as per City specs and design (pull boxes and secondary pedestals provided by the City). 8. Developer provides digital AutoCAD 2000 or later version of plat and/or site plan. Email to: sweido@cstx.gov. 9. Developer provides load data for project. 10. To discuss any of the above electrical comments please contact Sam Weido at 979.764.6314. Reviewed by: Sam Weido Date: 8-9-07