Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Drawings
CLASSIC RECREATION SYSTEMS, INC. NOT FOR CONSTRUCTION 10' 0" A FASCIA BEAM 24 GA. HR-36 STEEL ROOF A A CURVED RAFTER BEAM 24 GA. "J" CHANNEL co CAST IN PLACE CONCRETE COLUMN BY OTHERS (SEE DETAIL) o b A I /1--- I i 10"X10" • COLUMN 1' 9" i 5'2" I 1' 11" i 1' 2.' < >I< >I< >14 > HORIZONTAL BEAM > I PERIMETER BEAM A EXTENSION CD BEAM PLAN VIEW 10'X10' COLORADO MODEL W/ CONCRETE COLUMN NTS CLASSIC RECREATION SYSTEMS, INC. NOT FOR CONSTRUCTION 10. 0" EXTENSION 24 GA. HR-36 CURVED BEAM STEEL ROOF 111111 A _RAFTER ;0 BEAM u � FASCIA BEAM CAST IN PLACE CONCRETE COLUMN BY OTHERS 0 FINISH GRADE r END ELEVATION 10'X10' COLORADO MODEL W/ CONCRETE COLUMN NTS 24" 4'-10" < > < CLASSIC #3 TIES @ 12"O.C. "TYP" RECREATION ,ter--Lr--r-ei o� ,.4.-T--e.-Y-IP--r- N (NI r 1 1 1 ■1 SYSTEMS, INC. /L___;4._ j L.. 0L-6 kt__j SECTION B (16)#6 V BARS SECTION A (24)#6 V BARS PLAN VIEW W/#3 HOOPS PLAN VIEW W/#3 HOOPS NTS @ 12"0.C. NTS @ 12"O.C. 1'-5" 2'-0" 1'-5„ 2" Aj_,�_ ■ l— (3)#3 HOOPS IN TOP 5" :r 1. 1 1-1 1 @ A-BOLTS LOCATION I *-T-1 t'1 ��- V 1 '1-t SECTION B A i-t: t- �-1 i td_ 1 1 CAST IN PLACE CONC. d !-t-1- COLUMN 2500 PSI ' I 1 ' „1 Li_ 1 1 1 1 (16) #6 VERTICAL BARS j 1 -1-1-1- (REBAR 40,000 PSI)- SEE 1 1 1 •1 ti A. STRUCTURAL CALC'S FOR n7 1_;_T_;J_1 LAYOUT PLACEMENT 0 00 • 1J 1 1 -601 r t J `i 11 1 1 1 1 1 1' # 3 TIES 12" 0.C. TL-J-�1--L-LJ-iT (REBAR: 40,000 PSI) II. 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 (24)#6 VERTICAL REBAR iI"I-- -,--1-7-T-ri SEE STRUCTURAL CALC'S 1 1 1 1 1 <1 1 1 FOR LAYOUT PLACEMENT 11111114 %s r1-1--1-_1-_L-_1- 4 A r1 1 1 1 1 1 0 1 , 1 .1 1 ' � 1 1 ,tz GRADE LINE = IIIII _IIIIIII 4141 C1 1 ' 1111111 1111111= -1-1-1-4-1-IIS N _ � • SECTION A 'I 7 IIIII— ii, • 1 , •> 111111 ..<______-2500 II PSI CONC. FTG. 43 - — 1 I Ss (5) #4 BARS 18" 0.C. PARALLEL -r �iIIIII • '* iL'""'�'n'' '''rmir 1 TO THE 6'-0" DIMENSION IIIIIII -J = 111311 = =IIIIIII - c� < > 95% COMPACTED SUBGRADE SOIL 6'- 0" < > FRONT VIEW 10'x10' COLORADO MODEL FOOTING & COLUMN DETAIL NTS CLASSIC RECREATION SYSTEMS, INC. 1'-8" (3)#3 HOOPS IN TOP 5" @ A-BOLTS LOCATION I— �• SECTION B _ 1 —j �•I I. 1 _CAST IN PLACE CONC. t-14 'litCOLUMN 2500 PSI 4 �1 1 1 1► I 1 —I ; (16) #6 VERTICAL BARS (REBAR 40,000 PSI) - SEE I 1 I* STRUCTURAL CALC'S FOR 1 1 1 LAYOUT PLACEMENT 1_ 1__L 0 00 1 1 Eo in 1 1 1 I 1 1 #3 TIES 12"O.C. T--1--rte (REBAR: 40,000 PSI) 1 • i' 1 1 1 t--1--r 1 1 1 (24) #6 VERTICAL REBAR 1 1 fE S ikSTRUCTURAL CALC'S i_J_-4 LAYOUT PLACEMENT I I 1 . I I 1 I I 1 o I-'1--1• GRADE LINE 1 1 ,A.-7:-) / 1 1 � 1 IIIIIM.IIIIII ?).Gi' ;. 11111II_ 1111111= a' I. 1 - SECTION A isi • •I itJiIii== A 1 `;' ' 1 ' ,-2500 PSI CONC. FTG. 1 4 (13)#6 BARS 6" O.C. PARALLEL i • A----t�'L....6 ---41�fli TO THE 6'-6" DIMENSION 1011111111111 I�I3'I = 1111111 U I( 95% COMPACTED M SUBGRADE SOIL 6' -6" 10'x10' COLORADO MODEL SIDE VIEW FOOTING & COLUMN DETAIL NTS