Loading...
HomeMy WebLinkAboutStaff Comments 1101 Texas Avenue, P.O. Box 9960 College Station,Texas 77842 Phone 979.764.3570 / Fax 979.764.3496 MEMORANDUM September 20, 2007 TO: Mark Homeyer, owner,via fax 778.8020 FROM: Jason Schubert, Staff Planner SUBJECT: PEACH CROSSING PH 2 (FP) - Final Plat Staff reviewed the above-mentioned final plat as requested. The following page is a list of staff review comments detailing items that need to be addressed. If all comments have been addressed and the following information submitted by Monday, September 24, 2007, 10:00 a.m., your project will be placed on the next available Planning and Zoning Commission meeting scheduled for Thursday, October 4, 2007, 7:00 p.m. in the City Hall Council Chambers, 1101 Texas Avenue. One (1) 24"x36" copy of the revised final plat; Nineteen (19) 11"x17" copies of the revised final plat; One (1) copy of the digital file of the final plat via e-mail to sgriffin@cstx.gov; and The Mylar original of the revised final plat with the owner and County Judge's signatures (will be required after the County's approval). Upon receipt of the required documents for the Planning & Zoning meeting, your project will be considered formally filed with the City of College Station. Please note that if all comments have not been addressed, your project will not be scheduled for the Planning & Zoning Commission meeting. Your project may be placed on a future agenda once all the revisions have been made and the appropriate fees paid. Once your item has been scheduled for the P&Z meeting, the agenda and staff report can be accessed at the following web site on Monday the week of the P&Z meeting. http://www.cstx.gov/home/index.asp?page=2481 If you have any questions or need additional information, please call me at 979.764.3570. Attachments: Staff Review Comments cc: Steven Homeyer, Homeyer Engineering, Inc.,via fax 972.906.9987 Gary Arnold, Brazos County Planning&Traffic,via fax 775.0453 Case file #07-00500219 STAFF REVIEW COMMENTS NO. 1 Project: PEACH CROSSING PH 2 (FP) - 07-00500219 PLANNING 1. The acreage and dimensions of Lot 13 do not match the preliminary plat. Please revise. 2. In coordination with Phase 1,provide a Block number for the lots of the subdivision. 3. Remove Certificate for"Approval of the City Council." That approval is no longer required. 4. Provide certificate for County approval,which is: CERTIFICATE OF COUNTY JUDGE This subdivision was duly approved by the Commissioners Court of Brazos County, Texas, as the Final Plat of such subdivision of the day of , 20_. County Judge, Brazos County Reviewed by: Jason Schubert Date: September 19, 2007 BRAZOS COUNTY 1. No comments have been received as of the date of this transmittal. Reviewed by: Gary Arnold Date: BTU 1. BTU has no problem with underground utilities. However, I'm not sure a final plat is where the statement under General Notes "ALL PROPOSED POWER UTILITY LINES ... " belongs. I'd like to see that note struck from the plat. That is something that we work with the developer on based on their wishes. Reviewed by: Randy Trimble Date: September 13, 2007 ENGINEERING COMMENTS NO. 1 1. Please revise line types used for property line and private access easement. As submitted, it looks like the northern boundary of Lot 11 is the same as Lot 10 and does not include the 70' strip of access easement. 2. Remove 25'building line. 3. Development Permit not required in the ETJ, money will be refunded. Reviewed by: Carol Cotter Date: September 19, 2007 GENERAL ELECTRICAL COMMENTS 1. This plat is in the College Station ETJ, but is out of the College Station Utility electric service area. Customer will have to get with their electric supplier for this area to determine electric service specifications and requirements. Reviewed by: Timothy Crabb, CSU Electric, (979) 764-3439. Date: September 11, 2007 FIRE 1. No comments Reviewed by: Steve Smith Date: September 17, 2007 SANITATION 1. Sanitation is ok with this project. Reviewed by: Wally Urrutia Date: September 11, 2007 (*ffill41 CITY OF COT.I,FGE STATION Planning d Development Services 1101 Texas Avenue, P.O. Box 9960 College Station, Texas 77842 Phone 979.764.3570 / Fax 979.764.3496 MEMORANDUM September 26, 2007 TO: Mark Homeyer, owner, via fax 778.8020 FROM: Jason Schubert, Staff Planner SUBJECT: PEACH CROSSING PH 2 (FP) - Final Plat Staff reviewed the above-mentioned revised final plat as requested. The following page is a list of staff review comments detailing items that need to be addressed. These comments are being provided to the Planning & Zoning Commission as Staff Review Comments (conditions) that will need to be addressed for the plat to be filed for record. One (1) 24"x36" copy of the revised final plat; One (1) Mylar original of the revised final plat; and One (1) copy of the digital file of the final plat via e-mail to sgriffin@cstx.gov. The agenda and staff report can be accessed at the following web site on Monday the week of the P&Z meeting. http://www.cstx.gov/home/index.asp?page=2481 If you have any questions or need additional information, please call me at 979.764.3570. Attachments: Staff review comments cc: Steven Homeyer, Homeyer Engineering, Inc., via fax 972.906.9987 Gary Arnold, Brazos County Planning & Traffic, via fax 775.0453 Case file #07-00500219 Home of Texas A&M University STAFF REVIEW COMMENTS NO. 2 Project: PEACH CROSSING PH 2 (FP) - 07-00500219 PLANNING 1. Revise the title block to state "Lots 10-13, Block 1" after the subdivision name. 2. Remove the "25' B.L." label on the east side of the cul-de-sac. 3. Remove the underlining through the Certificate of the County Clerk. 4. Revise the dimensions on the north side of Lots 12 and 13 to reflect the respective distance. 5. Provide a copy of the existing access easement through the Dansby property to the north. 6. Provide the distances to tie-in to GPS monuments as given in initial submission. 7. Provide the General Notes as in the initial submission, except for the power utility lines note. Reviewed by: Jason Schubert Date: September 26, 2007 NOTE: Any changes made to the plans,that have not been requested by the City of College Station,must be explained in your next transmittal letter and"bubbled"on your plans.Any additional changes on these plans that have not been pointed out to the City,will constitute a completely new review. 2 of 2 STAFF REVIEW COMMENTS NO. 2 Project: PEACH CROSSING PH 2 (FP) - 07-00500219 PLANNING 1. Revise the title block to state "Lots 10-13, Block 1" after the subdivision name. 2. Remove the "25' B.L." label on the east side of the cul-de-sac. 3. Remove the underlining through the Certificate of the County Clerk. 4. Revise the dimensions on the north side of Lots 12 and 13 to reflect the respective distance. 5. Provide a copy of the existing access easement through the Dansby property to the north. 6. Provide the distances to tie-in to GPS monuments as given in initial submission. 7. Provide the General Notes as in the initial submission, except for the power utility lines note. Reviewed by: Jason Schubert Date: September 26, 2007