Loading...
HomeMy WebLinkAboutWater Report Water System Report for Saddle Creek Subdivision, Phases 1-2 College Station, Texas October 2007 Prepared By: Civil Development, Ltd. 2900 Longmire Drive, Suite K College Station, Texas 77845 (979) 764-7743 V* -NA r.. • ' 1l /0%//07 / General Information Location: Saddle Creek Subdivision, Phases 1-2 are located in southern Brazos County, near the intersection of Wade Road and Stousland Road. Phase 1 was completed in the Spring of 2007. No. of Lots: Phase 1 - 35 lots Phase 2 - 14 lots Land Use: Single Family Residential—rural estate lots that are I acre or larger WATER SYSTEM ANALYSIS Design Criteria Prirnaiy Water Supply: Existing 12"line along Stousland Road operated by Wellborn SUD. Domestic Demand: Avg. Pop Density: 2.67 people per lot Average Flow: 100 gpd/cap or 267 gpd per lot=0.18 gpm per lot Peaking Factor: 4 Peak Flow: 0.74 gpm per lot Design Flow: 1.50 gpm per lot Fire Demand: Fire Flow: 1000 gpm at most hydraulically remote hydrant in Ph 2 Pipe: PVC DR-14 C909 Roughness Coeff. 150(Hazen Williams) Hydraulic Software: Haestad Methods WaterCAD v.6.0 Existing System Pressure Tests Flow Hydrant: Fire Hydrant on Stousland Road,south of Wade Road. Flowrate: 1300 gpm Guage Location: 5401 Stousland Road(hose bib on side of house) Static Pressure: 78 psi (180 ft water) Residual Pressure: 75 psi(173 ft water) Applicable Exhibits: Exhibit B—Flow Test Report Water System Analysis Summary As Criteria E Required DesignedLocation Min. Pressure-fire(psi) 20 71.13 SC204 * • Max. Velocity(fps) 12 2.93 P201 Max. Length of 6"pipe(ft) (connected to > 8"on both 1500 NA ends) • Max Length of 6"pipe(ft) 800 NA (not connected on both ends) • Max. Length of 3"pipe(ft) 1 500 257 Note: The lowest water pressure occurred at SCIOI. The nearest fire hydrant to that point is at SC2 FH1. That is the location where a 1000 gpm fire demand was added for modeling purposes. Applicable Exhibits: Exhibit A—Water System Schematic Exhibit C—Water System Analysis—Junction Summary Exhibit D—Water System Analysis—Pipe Summary Conclusion The proposed water system for Saddle Creek Subdivision, Phases 1 and 2 meets or exceeds all of the design criteria for the City of College Station. It will provide adequate water pressure and flow for both domestic and fire demands. Exhibit B Water System Flow Test Report Date: November 16, 2006 Water System Owner: Wellborn Special Utility District Development Project: Saddle Creek Subdivision Flow Test Location: Fire Hydrant @ 5401 Stousland Nozzle size (in.): 2.5 Discharge Coef: (c): 0.9 Pitot Reading (psi): 60 Flowrate formula: Q=29.84cd2p1/2 c=discharge coef. d=orifice size(in) p=pitot pressure(psi) Flowrate (gpm): 1300 computed Pressure Guage Location: Hose Bib on House at 5401 Straub Static (psi): 78 Residual (psi): 75 Report prepared by: signature . Kent Laza r; 65623 printed name ', Others present: Steven Cast Exhibit C Saddle Creek Subdivision, Phases 1-2 Water System Analysis - Junction Summary Fire Flow Conditions Label Elevation Demand Hydraulic Pressure Grade (ft) (gpm) (ft) (psi) SC1 FH1 284 3.0 459.57 75.96 SC1 FH2 276 0.0 457.64 78.59 SC1 FH3 273 6.0 457.42 79.79 SC1 FH4 273 0.0 457.42 79.79 SC2 FH1 277 1,000.0 443.40 71.99 Phase 2 SC102 275 7.5 457.42 78.92 SC103 274 9.0 457.35 79.33 SC104 273 4.5 457.42 79.79 SC105 275 4.5 457.42 78.92 SC106 282 0.0 457.42 75.90 SC201 277 15.0 443.40 71.99 SC202 277 0.0 443.40 71.99 Phase 2 SC203 274 7.5 443.34 7327 SC204 279 0.0 443.40 7113 Lowest Pressure= 71.13 Phase 2 Exhibit D Saddle Creek Subdivision, Phases 1-2 Water System Analysis - Pipe Summary Fire Flow Conditions Label Length Diameter Material Hazen- Discharge ] Velocity (ft) (in) Williams C (gpm) (ft/s) (ft/s) P101 446 12 PVC 150 -1,057.00 3.00 P102 898 12 PVC 150 -1,054.00 2.99 P103 103 12 PVC 150 -1,054.00 2.99 P104 264 3 PVC 150 9.00 0.41 P105 610 12 PVC 150 15.00 0.04 P106 796 12 PVC 150 -9.00 0.03 P107 23 8 PVC 150 0.00 0.00 P108 994 8 PVC 150 0.00 0.00 P109 634 12 PVC 150 -4.50 0.01 P201 960 8 PVC 150 -1,022.50 6.53 P202 22 8 PVC 150 -22.50 0.14 P203 81 8 PVC 150 -7.50 0.05 Phase 2 P204 292 3 PVC 150 7.50 0.34 P205 292 8 PVC 150 0.00 0.00 Highest Velocity= 6.53 Phase 2 f /i ,/,/ ES E1 FH i /// '\p101 / , S FH1 \ // / ,,` // P1-0-2-- Ca.N.J. C1 C1 4'7. SC 13� \ -- P11 -. /, P103 -- SC102 UIII - '105 .11 if SC FH3 P201 /7/ ill{ \ '10:. g a P202 \SC11 ' --- - P205 &jai, ` 21 SC204 .77�' \ - ----- , i3P. 04 �. b02 P109 --- ___ SC105 ._._._ i�I ._ _. _._._ ._.__ l it I P108 111 j1 Y C106 EXHIBIT SADDLE CREEK, PHASE 2 *CMDEVILLOPMEN,Lcc* A 2990 eStatire neves 77845 SCALE: NOT TO SCALE WATER SYSTEM SCHEMATIC uite K College Station,Texas 77645 P.O.Box 11929,College Station,Texas 77642 (979)764-7743 13x:(979)764-7759