Loading...
HomeMy WebLinkAboutCorrespondence (*ffi I I I I I I I CITY OF COLLEGE STATION Planning d Development Services 1101 Texas Avenue, P.O. Box 9960 College Station, Texas 77842 Phone 979.764.3570/ Fax 979.764.3496 MEMORANDUM July 3, 2006 TO: Barry P. Ivins, Applicant-via fax #979.680.9898✓ FROM: Crissy Hartl, Staff Planner SUBJECT: CORNER BAR (SP)- Site Plan Staff reviewed the above-mentioned site plan as requested. The following page is a list of staff review comments detailing items that need to be addressed. Please address the comments and submit the following information for further staff review: One (1) revised site plan. Easement Dedication Sheet and required documents. Please note that the Easement Dedication Sheet and necessary documents are required prior to the issuance of a building permit. If there are comments that you are not addressing with the revised site plan, please attach a letter explaining the details. If you have any questions or need additional information, please call me at 979.764.3570. Attachments: Staff review comments cc: Shelton Family Partnership, Owner-via fax #214.526.2366 Attn: Fred Shelton Holster&Associates, Architect-via fax #979.693.8370 Case file #06-00500139 Home of Texas A&M University rAX1 X11\ SCHEDULE OF MATERIALS AND COLORS 08/14/06 FOR CORNER BAR-401 UNIVERSITY DRIVE, COLLEGE STATION, TX NORTH GATE DISTRICT NG-1 PREPARED BY: Holster&Associates, Inc. 7607 Eastmark Drive Suite#200 College Station, TX 77845 t: 979.693.3179 f: 979.693.8370 Item Color Roof Railing Rock Gardens SW 6195 ( UDO Color) Roof Cap Snowfall SW 6000 ( UDO Color) Horizontal Trim Snowfall SW 6000 ( UDO Color) Window Sill & Headers Snowfall SW 6000 ( UDO Color) Window Frames Anodized Aluminum Brick Samples submitted Complimentary Brick Selection Stucco Light Tan Awning Rock Gardens SW 6195 ( UDO Color) AREA OF MATERIALS NEW EXISTING TOTAL % OF TOTAL NORTH FACADE 1053.49 1022.30 2075.79 GLASS 69.60 109.80 179.40 8.64% STUCCO 698.50 852.06 1550.56 74.70% BRICK 190.92 0.00 190.92 9.20% OTHER 94.47 60.44 154.91 7.46% SOUTH FACADE 1354.47 2125.17 3479.64 GLASS 0 851.37 851.37 24.47% STUCCO 123.98 0.00 123.98 3.56% BRICK 491.02 1012.87 1503.89 43.22% OTHER 739.47 260.93 1000.40 28.75% EAST FACADE 614.34 1395.01 2009.35 GLASS 33.73 0.00 33.73 1.68% STUCCO 484.47 1300.53 1785.00 88.83% BRICK 96.14 0.00 96.14 4.78% OTHER 0.00 94.48 94.48 4.70% WEST FACADE 351.90 1402.00 1753.90 GLASS 115.00 523.00 638.00 36.38% STUCCO 77.00 0.00 77.00 4.39% BRICK 230.70 768.50 999.20 56.97% OTHER 42.00 123.00 165.00 9.41% Jun. 5. 2006 3:45PU1 Holster & Associates No. 1980 P. 2 6/5/2006 Holster & Associates, Inc. Architecture,Planning and Interior Design DESIGN NOTES PROJECT: Renovation &Additions to the"Corner Bar" located in Northgate LOCATION: Located within the Sparks Building at 401 University Drive, College Station, TX 77840 Boyett, Block 2, Lots 1, 2, 3 and part of 4 REVIEW: Pre-application Review DATE: June 5, 2006 NOTES: 1. The client is a tenant of the building being renovated. To all knowledge of the design firm, the client has informed the owner of all plans to modify the building. 2. The tenant currently occupies a 2115 sq ft space of the first floor only. 3. The tenant has made arrangements with the owner to occupy and renovate a portion of space on the second floor and also possibly the roof area. 4. To access the second floor space, the proposed modifications include removing the existing exterior fire stair, enclosing the area and reconstructing a new interior stair to provide access to the newly renovated second floor and also to the rooftop area. 5. The proposed stair well enclosure will completely fill the alley way between the Sparks building and the adjacent building to the north on College Main. The proposed enclosure will be a fire rated construction to provide means of egress. 6. The tenant would like to convert the roof top of the building to usable space for the"Corner Bar" by providing a full service bar on the roof. 7. The newly renovated 2nf floor will provide the tenant with approximately an additional 2015 sq ft of space. 8. The proposed rooftop conversion will possibly provide the new tenant with an additional 3000 sq ft of space. 9. This building is located within the Northgate District and should have an NG-1 Classification. See attached sheets=total of 3 Holster Associates, Inc 3308 Longmire Drive, College Station,TX 77845 Te1:979.693.3179 Fax:979.693.8370 Page 1 of 1