HomeMy WebLinkAboutapplication FOR OFFICE USE 06NLY
(Lir P&Z CASE NO.: C Cr—1
DATE SUBMITTED: ` l
CITY OF COLLEGE STATION � '"e1�(F
Planning ub'Development Services L "
PRELIMINARY PLAT APPLICATION
The following items must be submitted by an established filing deadline date for P &Z Commission
consideration.
MINIMUM SUBMITTAL REQUIREMENTS:
X Filing Fee of$400.00.
Variance Request to Subdivision Regulations - $100 (if applicable)
X Application completed in full.
X Thirteen (13) folded copies of plat. (A revised mylar original must be submitted after staff review.)
One (1) copy of the approved Master Plan if applicable.
X A copy of the attached checklist with all items checked off or a brief explanation as to why they are not.
Rezoning Application if zone change is proposed.
Parkland Dedication requirement approved by the Parks & Recreation Board, please provide proof of
approval (if applicable).
Date of Preapplication Conference:
NAME OF SUBDIVISION North Forest Estates
SPECIFIED LOCATION OF PROPOSED SUBDIVISION 1100' northeast along North Forest
Parkway from State Highway No. 6 (East By-Pass).
APPLICANT/PROJECT MANAGER'S INFORMATION (Primary Contact for the Project):
Name Justin Whitworth
Street Address P.O. Box 11671 City College Station
State TX Zip Code 77842 E-Mail Address justinwCa century21 bcs.com
Phone Number 979-739-4930 Fax Number 979-764-0421
PROPERTY OWNER'S INFORMATION (ALL owners must be identified. Please attach an additional sheet for
multiple owners):
Name Whitworth North Forest Dev LP
Street Address same as above City
State Zip Code E-Mail Address
Phone Number Fax Number
ARCHITECT OR ENGINEER'S INFORMATION:
Name Kling Engineering & Surveying
Street Address 4101 S. Texas Ave Ste A City Bryan
State TX Zip Code 77802 E-Mail Address stewartagklingeng.com
Phone Number 979-846-6212 Fax Number 979-846-8252
6/13/03 1 of 4
Total Acres Of Subdivision 9.95 R-O-W Acreage 1.26 Total # Of Lots 28
Number Of Lots By Zoning District 28 / R1 / /
Average Acreage Of Each Residential Lot By Zoning District:
Floodplain Acreage none
Parkland dedication by acreage or fee? fee
A statement addressing any differences between the Preliminary Plat and approved Master Plan (if
applicable) not applicable
Requested variances to subdivision regulations & reason for same Sec. 8-K for Lots 11
and 12, Block 2. The reasons for the variance request are as follows (see separate sheet)
Requested oversize participation none
Parkland Dedication due prior to filing the Final Plat:
ACREAGE:
# of Acres to be dedicated # of acres in floodplain
# of acres in detention # of acres in greenways
OR
FEE IN LIEU OF LAND:
# of Single-Family Dwelling Units X $556 =$
(date) Approved by Parks & Recreation Board
The applicant has prepared this application and certifies that the facts stated herein and exhibits
attached hereto are true and correct. The undersigned hereby requests approval by the City of
College Station of the above identified plat and attests that all respective owners have been identified
on this application.
AVIir S /q
-ig =ture and Title Date
c/1 2 of
SUBMIT APPLICATION AND THIS
LIST CHECKED OFF WITH 13
FOLDED COPIES OF PLAT FOR REVIEW
CITY OF COLLEGE STATION
Planning dr Development Services,.
NORTH FOREST ESTATES
PRELIMINARY PLAT MINIMUM REQUIREMENTS
(ALL CITY ORDINANCES MUST BE MET)
INCLUDING BUT NOT LIMITED TO THE FOLLOWING:
Z 1. Drawn on 24" x 36" sheet to scale of 100' per inch or larger. Include the words "PRELIMINARY
PLAT - NOT FOR RECORD" in letters 1/2" high. If more than 1 sheet, an index sheet showing
entire subdivision at a scale of 500 feet per inch or larger.
® 2. Vicinity map which includes enough of surrounding area to show general location of subject
property in relationship to College Station and its City Limits. No scale required but include north
arrow.
® 3. Title Block with the following information:
® Name and address of subdivider, recorded owner, planner, engineer and surveyor.
• Proposed name of subdivision. (Subdivision name & street names will be approved
through Brazos County 911.) (Replats need to retain original subdivision name.)
® Date of preparation. (INCLUDE DATE THE PLAT WAS SUBMITTED AND THE
DATES OF ANY REVISIONS ON THE PLAT)
® Engineer's scale in feet.
® Total area intended to be developed.
® 4. North Arrow.
® 5. Location of current city limit lines and current zoning district boundary.
® 6. Subdivision boundary indicated by heavy lines. Boundary must include all of parent tract.
® 7. Descriptions by metes and bounds of the subdivision which shall close within accepted land
survey standards. (Labeled on boundary lines, not separate metes and bounds description.)
® 8. Primary control points or descriptions and ties to such control point, to which , later, all
dimensions, angles, bearings, block numbers, and similar data shall be referred. The plat shall be
located with respect to a corner of the survey or tract, or an original corner of the original survey
of which it is a part.
Z 9. Name of contiguous subdivisions and names of owners of contiguous parcels of unsubdivided
land, and an indication whether or not contiguous properties are platted.
® 10. Location of the 100 Year Floodplain and Floodway, if applicable, according to the most recent
available data.
® 11. Topographic information, including contours at two foot (2 ft.) intervals, wooded areas, and
flowline elevation of streams.
1..4"A
Z 12. Proposed land uses (In compliance with Land Use Plan).
® 13. Proposed zoning changes, if any, submit formal rezoning request.
® 14. The location and description with accurate dimensions, bearings or deflection angles and radii,
area, center angle, degree of curvature, tangent distance and length of all curves for all of the
following: (Show existing items that are intersecting or contiguous with the boundary of or
forming a boundary with the subdivision, as well as, those within the subdivision).
Existing Proposed
® Z Streets. Continuous or end in a cul-de-sac, stubbed out streets must end into a temp.
turn around unless they are shorter than 100 feet.
® ® Public and private R.O.W. locations and widths. (All existing and proposed R.O.W.'s
sufficient to meet Thoroughfare Plan.)
❑ n/a❑ Street offsets and/or intersection angles meet ordinance.
❑ n/a❑ Alleys.
O n/a❑ Reserve tracts.
O n/a❑ Well site locations.
O n/a❑ Pipelines. If carrying flammable gas or fuel, also show size of line, design pressure and
product transported through the line.
® ® Utility Services. (Water & Sanitary Sewer) All existing and proposed utilities of sufficient
size/depth to meet the utility master plan and any future growth areas.
® ® Easements.
® 0 Drainage Structures and improvements including underground storm sewer and all
overland systems (flow line of existing watercourses) and showing where these will
discharge. Proposed channel cross sections, if any.
❑ ® A number or letter to identify each lot or site and each block.
❑ n/a❑ Greenbelt area/park linkages/parkland dedication (All proposed dedications must be
reviewed by the Parks and Recreation Board prior to P & Z Commission consideration.)
❑ n/a❑ Public areas
O n/a❑ Other public improvements, including but not limited to parks, schools and other public
facilities
On/a 15. Proposed phasing. Each phase must be able to stand alone to meet ordinance requirements and
infrastructure costs should be distributed evenly throughout the subdivision..
® 16. Are there impact fees associated with this development? ❑ Yes ® No
® 17. If requesting oversize participation items, are the necessary impact studies included?
❑Yes
❑No
Z N/A
6/13/03 4 of 4
(kffr FOR OFFICE USE ONLY
P&Z CASE NO.: OLP 'lam(
CITY OF COLLEGE STATION DATE SUBMITTED4"11 'd W
Planning&Development Services
8, 51
PRELIMINARY PLAT APPLICATION g'S
The following items must be submitted by an established filing deadline date for P & Z Commission
consideration.
MINIMUM SUBMITTAL REQUIREMENTS:
X Filing Fee of$400.00.
Iv.Variance Request to Subdivision Regulations - $100 (if applicable)
X Application completed in full.
X Thirteen (13) folded copies of plat. (A revised mylar original must be submitted after staff review.)
NW One (1) copy of the approved Master Plan if applicable.
X A copy of the attached checklist with all items checked off or a brief explanation as to why they are not.
04 Rezoning Application if zone change is proposed.
frJ c Parkland Dedication requirement approved by the Parks & Recreation Board, please provide proof of
approval (if applicable).
Date of Preapplication Conference:
NAME OF SUBDIVISION North Forest Estates
SPECIFIED LOCATION OF PROPOSED SUBDIVISION 1100' northeast along North Forest
Parkway from State Highway No. 6 (East By-Pass).
APPLICANT/PROJECT MANAGER'S INFORMATION (Primary Contact for the Project):
Name Justin Whitworth
Street Address P.O. Box 11671 City College Station
State TX Zip Code 77842 E-Mail Address justinw@century21 bcs.com
Phone Number 979-739-4930 Fax Number 979-764-0421
PROPERTY OWNER'S INFORMATION (ALL owners must be identified. Please attach an additional sheet for
multiple owners):
Name Whitworth North Forest Dev LP
Street Address same as above City
State Zip Code E-Mail Address
Phone Number Fax Number
ARCHITECT OR ENGINEER'S INFORMATION:
Name Kling Engineering & Surveying
Street Address 4101 S. Texas Ave Ste A City Bryan
State TX Zip Code 77802 E-Mail Address stewart(a�klingeng.com
Phone Number 979-846-6212 Fax Number 979-846-8252
6/13/03 1 of 4
04/13/2006 17:31 FAX a002/002
04/13/2006 15:58 c 468252 PAGE 02/02
Total Acres Of Subdivision 9.95 R-O-W Acreage 1.26 Total#Of Lots 26
Number Of Lots By Zoning District 28 /
Average Acreage Of Each Residential Lot By Zoning District:
I I I I
Floodplain Acreage none
Parkland dedication by acreage or fee? fee
A statement addressing any differences between the Preliminary Plat and approved Master Plan(if
applicable) not applicable
Requested variances to subdivision regulations &reason for same none
Requested oversize participation none
Parkland Dedication due prior to filing the Final Plat:
ACREAGE:
#of Acres to be dedicated #of acres in floodplain
#of acres in detention #of acres in greenways
OR
FEE IN LIEU OF LAND:
#of Single-Family Dwelling Units X$556=$_
(date)Approved by Parks&Recreation Board
The applicant has prepared this application and certifies that the facts stated herein and exhibits
attached hereto are true and correct. The undersigned hereby requests approval by the City of
College Station of the above identified plat and attests that a respective owners have been identified
on this application.
gr,v Air LI/I 06/
•ig .ture and Title Date
SUBMIT APPLICATION AND THIS
LIST CHECKED OFF WITH 13
FOLDED COPIES OF PLAT FOR REVIEW
CITY OF COLLEGE STATION
Planning d Development Services,
NORTH FOREST ESTATES
PRELIMINARY PLAT MINIMUM REQUIREMENTS
(ALL CITY ORDINANCES MUST BE MET)
INCLUDING BUT NOT LIMITED TO THE FOLLOWING:
® �1. Drawn on 24" x 36" sheet to scale of 100' per inch or larger. Include the words "PRELIMINARY
PLAT - NOT FOR RECORD" in letters 1/2" high. If more than 1 sheet, an index sheet showing
entire subdivision at a scale of 500 feet per inch or larger.
® IA. Vicinity map which includes enough of surrounding area to show general location of subject
property in relationship to College Station and its City Limits. No scale required but include north
arrow.
• i Title Block with the following information:
® Name and address of subdivider, recorded owner, planner, engineer and surveyor.
® Proposed name of subdivision. (Subdivision name & street names will be approved
through Brazos County 911.) (Replats need to retain original subdivision name.)
Z Date of preparation. (INCLUDE DATE THE PLAT WAS SUBMITTED AND THE
DATES OF ANY REVISIONS ON THE PLAT)
® Engineer's scale in feet.
® Total area intended to be developed.
k/4. North Arrow.
® Location of current city limit lines an') current zoning district boundary
• t7 6. Subdivision boundary indicated by heavy lines. Boundary must include all of parent tract.
® 7). Descriptions by metes and bounds of the subdivision which shall close within accepted land
survey standards. (Labeled on boundary lines, not separate metes and bounds description.)
• ✓8. Primary control points or descriptions and ties to such control point, to which , later, all
dimensions, angles, bearings, block numbers, and similar data shall be referred. The plat shall be
located with respect to a corner of the survey or tract, or an original corner of the original survey
of which it is a part.
® 9. Name of contiguous subdivisions and names of owners of contiguous parcels of unsubdivided
land, and an indication w-heth r or not contiguous properties are platted.
• 10. Location of the 100 Year Floodplain and Floodway, if applicable, according to the most recent
available data.
® . 11. Topographic information, including contours at two foot (2 ft.) intervals, wooded areas, and
flowline elevation of streams.
a(,f4
./12. Proposed land uses (In compliance with Land Use Plan).
-'13. Proposed zoning changes, if any, submit formal rezoning request.
® )4. The location and description with accurate dimensions, bearings or deflection angles and radii,
area, center angle, degree of curvature, tangent distance and length of all curves for all of the
following: (Show existing items that are intersecting or contiguous with the boundary of or
forming a boundary with the subdivision, as well as, those within the subdivision).
Existing Proposed
® Z Streets. Continuous or end in a cul-de-sac, stubbed out streets must end into a temp.
turn around unless they are shorter than 100 feet.
® Public and private R.O.W. locations and widths. (All existing and proposed R.O.W.'s
sufficient to meet Thoroughfare Plan.)
n/a9 Street offsets and/or intersection angles meet ordinance.
8 n/a8 Alleys.
B n/aE Reserve tracts.
• n/a0 Well site locations.
Q n/aR Pipelines. If carrying flammable gas or fuel, also show size of line, design pressure and
product transported through the line.
® Utility Services. (Water & Sanitary Sewer) All existing and proposed utilities of sufficient
size/depth to meet the utility master plan and any future growth areas.
® Easements.
• El- Drainage Structures and improvements including underground storm sewer and all
overland systems (flow line of existing watercourses) and showing where these will
discharge. Proposed channel cross sections, if any.
❑ ® A number or letter to identify each lot or site and each block.
8 n/ae Greenbelt area/park linkages/parkland dedication (All proposed dedications must be
reviewed by the Parks and Recreation Board prior to P & Z Commission consideration.)
8 n/aB Public areas
O n/a0 Other public improvements, including but not limited to parks, schools and other public
facilities
Rn/a 15. Proposed phasing. Each phase must be able to stand alone to meet ordinance requirements and
infrastructure costs should be distributed evenly throughout the subdivision..
16. Are there impact fees associated with this development? ❑ Yes ® No
17. If requesting oversize participation items, are the necessary impact studies included?
❑Yes
❑No
®N/A
4of4